At least 397 records · Page 22

SCALE Code Validation for Prismatic High-Temperature Gas-Cooled Reactors

Using experimental data published in the International Handbook of Evaluated Reactor Physics Benchmark Experiments for the fresh cold core of the High Temperature Engineering Test Reactor, a comprehensive validation study has been carried out to assess the performance of the SCALE code system for analysis of high-temperature gas-cooled reactor configurations. This paper describes part of the results of that effort. The studies performed included criticality evaluations for the full core and for the annular cores realized during the fuel loading, as well as calculations and comparisons for excess reactivity, shutdown margin, control rod worths, temperature coefficient of reactivity, and reaction rate distributions. Comparisons of the SCALE results with both experimental values and MCNP-calculated values are presented. The comparisons show that the SCALE calculated results, obtained with both multigroup and continuous energy cross sections, are in reasonable agreement with the experimental data and the MCNP predictions.

code validation↗

Comparison of a Few Statistical Methods for Validation

Many institutions are using a sophisticated statistical methodology to validate criticality safety computer codes in compliance with the ANSI/ANS-8.1 and -8.24 standards (Ref. 1 and 2). Here a few similar statistical methods are compared, namely, the USLSTATS method developed by the Oak Ridge National Laboratory (ORNL), the Washington Safety Management Solutions (WSMS) method, and the GE USLSA method. These methods use the "trending analysis" technique, namely, the derivation of bias for an application is correlated to biases for benchmark experiments. The methods use regression techniques to identify trends. But they differ in choice and calculation of specific “regression parameters”.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ConnectX-2 InfiniBand Management Queues: First Investigation of the New Support for Network Offloaded Collective Operations

This paper introduces the newly developed Infini-Band (IB) Management Queue capability, used by the Host Channel Adapter (HCA) to manage network task data flow dependancies, and progress the communications associated with such flows. These tasks include sends, receives, and the newly supported wait task, and are scheduled by the HCA based on a data dependency description provided by the user. This functionality is supported by the ConnectX-2 HCA, and provides the means for delegating collective communication management and progress to the HCA, also known as collective communication offload. This provides a means for overlapping collective communications managed by the HCA and computation on the Central Processing Unit (CPU), thus making it possible to reduce the impact of system noise on parallel applications using collective operations. This paper further describes how this new capability can be used to implement scalable Message Passing Interface (MPI) collective operations, describing the high level details of how this new capability is used to implement the MPI Barrier collective operation, focusing on the latency sensitive performance aspects of this new capability. This paper concludes with small scale benchmark experiments comparing implementations of the barrier collective operation, using the new network offload capabilities, with established point-to-point based implementations of these same algorithms, which manage the data flow using the central processing unit. These early results demonstrate the promise this new capability provides to improve the scalability of high performance applications using collective communications. The latency of the HCA based implementation of the barrier is similar to that of the best performing point-to-point based implementation managed by the central processing unit, starting to outperform these as the number of processes involved in the collective operation increases.

Graham, Richard L↗

Advancing Inverse Sensitivity/Uncertainty Methods for Nuclear Fuel Cycle Applications

The inverse sensitivity/uncertainty quantification (IS/UQ) method has recently been implemented in the Inverse Sensitivity/UnceRtainty Estimiator (INSURE) module of the AMPX system [1]. The IS/UQ method aims to quantify and prioritize the cross section measurements along with uncertainties needed to yield a given nuclear application(s) target response uncertainty, and doing this at a minimum cost. Since in some cases the extant uncertainties of the differential cross section data are already near the limits of the present-day state-of-the-art measurements, requiring significantly smaller uncertainties may be unrealistic. Therefore we have incorporated integral benchmark experiments (IBEs) data into the IS/UQ method using the generalized linear least-squares method, and have implemented it in the INSURE module. We show how the IS/UQ method could be applied to systematic and statistical uncertainties in a self-consistent way. We show how the IS/UQ method could be used to optimize uncertainties of IBEs and differential cross section data simultaneously.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Initial Investigations of the Criticality Safety Validation Basis for HA-LEU Transportation

Many proposed advanced nuclear energy systems require so called high-assay low enriched uranium (HALEU), which has a 235U enrichment >5 wt% and <20 wt%, where the current fleet of light water reactors (LWRs) utilize enrichments of 5 wt% or less. With few benchmark experiments in HA-LEU enrichment range, the interplay of the cross sections for multiple nuclei become important, especially for LEU experiments where 1H, 16O, 235U, 238U and others are applied simultaneously in the calculation of the integral keff response. With continuing evidence that nuclear data are tuned to reproduce expected keff values for selected criticality experiments, which likely do not include those with 20 wt% 235U, particular attention must be given to validation.This paper describes the impact of recent nuclear data changes on HA-LEU and provides a preliminary sensitivity/uncertainty-based assessment of the applicability of available of criticality experiments for the validation of licensing calculations for the transportation of small quantities of 20 wt% UF6.

Rearden, Bradley↗

General Handling Calculations for the Modified Hospital Can

Containers are evaluated using a Monte-Carlo N-Particle transport code (MCNP). The code calculated keff is compared to critical experiment benchmarks to determine a bias. Additional margin of safety is added to the bias to establish an upper subcritical limit (USL). Modeled cases are considered subcritical if the neutron multiplication factor plus two sigma remains below the USL. Net weight limits allow for any amount of fissile/moderator mixture to exist so long as it meets the weight requirement, therefore all mixture types must be evaluated. Cases that exceed the USL must either be controlled against or have justification why that configuration cannot reasonably exist. Current and legacy loadings and container dimensions must be taken into consideration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sensitivity Coefficients Calculated for the Prompt Neutron Decay Constant At or Near Delayed Critical

The derivation of a non-invasive prompt neutron decay constant sensitivity coefficient is provided in this work. The computation of the sensitivity coefficient derived in this work does not require modification of Monte Carlo source code and is based on capabilities available in Monte Carlo N-Particle R© Code Version 6.2. The prompt neutron decay constant sensitivity coefficients are calculated for 44-group and 252-group energy structures for specific nuclide-reaction pairs in the Jezebel benchmark experiment. The nuclide-reaction pairs investigated in this work include Pu- 239(n,f), Pu-240(n,f), and Pu-241(n,f). Physical explanations of the sensitivity profiles exhibited by the 252-group energy structure are investigated for the prompt neutron multiplication factor, mean neutron lifetime, and prompt neutron decay constant. The prompt neutron decay constant sensitivity coefficients calculated for the 44-group and 252-group energy structure of Pu-239(n,f) are compared. Lastly, the 44-group energy structure sensitivity coefficients calculated are used for nuclear-data induced uncertainty quantification of the neutron multiplication factor. This work shows that a reduction in the nuclear data-induced uncertainty of the neutron multiplication factor is possible for all nuclide-reaction pairs investigated when prompt neutron decay constant sensitivity coefficients are utilized. This is important for new critical experiment design optimization studies of measurement configurations. This work provides a basis for more detailed sensitivity analysis and uncertainty quantification of nuclide, reaction, and energy-specific cross section data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reactivity Coefficient Measurements and Sensitivity Studies [Abstract]

Nuclear data validation is often performed today using criticality measurements. The gold standard for criticality measurements is the International Criticality Safety Benchmark Experiment Project (ICSBEP). The validation specifically focuses on the effective multiplication factor (k eff ). K eff is a relatively easy parameter to infer and has reduced uncertainty due to being at or above critical. However, while k eff is a well-documented parameter with detailed sensitivity and uncertainty analysis, it cannot be used as a standalone metric to determine inaccuracies in nuclear data (e.g., cross section data, PFNS, nu), which is based on theory, physics, and differential measurements. The Experiments Underpinned by Computational Learning for Improvements in nuclear Data (EUCLID) project aims to identify compensating errors in specific nuclear data by optimally designing experiments that are sensitive to a suite of measurement parameters beyond k eff . By identifying how each parameter's nuclear data sensitivity differs from others, experiments can be designed to constrain questionable nuclear data. One sensitivity that is of particular interest to this project includes reactivity coefficient sensitivities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Estimating β eff from static, late-time Feynman neutron noise measurements

The effective delayed neutron fraction, β eff , is a kinematic parameter describing the contribution of delayed neutrons to the effective multiplication factor, $\kappa$ eff , and is of great interest to the nuclear criticality safety community and beyond. In fact, $\kappa$ eff presently must be inferred (as opposed to directly measured) since variables like β eff must be obtained from simulation, reference tables, or a dynamic or pulsed measurement where the assembly of fissile material is perturbed and not in steady state. Several recent works have proposed neutron noise techniques to estimate β eff from static measurements (such as benchmark experiments). This work experimentally investigates an approach based on looking at late-time (up to thousands of seconds) correlated neutrons in Feynman histograms. This work utilizes measurements of weapons grade plutonium and highly enriched uranium to construct late-time Feynman histograms and investigate a proposed methodology of estimating β eff from a fit of the distribution. Data is shown from both He-3 detectors and an organic scintillator array. This work is preliminary in nature, demonstrating some experimental feasibility and proposing improvements for future investigations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Advancing the Theory of Nuclear Data Evaluations [Abstract]

We present recent advances in the R-matrix formalism as well as the Bayesian evaluation framework for improved nuclear data evaluations. The advances in the R matrix formalism include: 1) direct processes, 2) doorway, as well as multistep, processes, and 3) various forms of the Reich-Moore approximation for eliminated capture channels. Furthermore, to address unreasonably small posterior uncertainties often encountered in nuclear data evaluations of large data sets using the conventional form of the Bayes’ theorem, we introduce imperfections (of the data or the model) as a formal evaluation tool for taming the evaluated uncertainties in harmony with Bayes’ theorem. These theoretical advances were motivated by the nuclear data evaluations of differential resolved resonance cross section data using the code SAMMY, as well as the integral benchmark experiments using the SCALE code system, being performed at Oak Ridge National Laboratory for the Nuclear Criticality Safety Program. Some pedagogical applications of the new formalism, as well as a snapshot of the SAMMY modernization efforts, will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of a Density Law via Python for Aqueous Plutonium Nitrate

A predictive density tool has been developed in Python to reduce bias and uncertainty in nuclear criticality safety calculations for plutonium nitrate systems. The Pitzer Method and an empirical method were implemented into the tool, allowing for plutonium nitrate density calculations. Additionally, the Python tool can generate atom densities for a MCNP6.2 material card using the density from the selected method and directly the densities into a prepared MCNP6 input text file. The material card and density are calculated based on customizable user inputs of plutonium content, nitric acid content, temperature, plutonium isotope weight percentages and impurity concentrations. The Python tool has been validated and verified against the International Handbook of Evaluated Criticality Safety Benchmark Experiments to predict densities within a root mean square error of 1.0% for the Pitzer method and 1.8% for the empirical method. These errors in density were shown to lead to a ±0.5% error in MCNP6.2 calculated k effective for the Pitzer method and a ±1.7% error for the Empirical method. Simultaneous work is also being done at the University of New Mexico and Los Alamos National Laboratory to create a similar tool for plutonium chloride solutions, which aims to provide the accreditation of the chlorine absorption. These capabilities will not only provide more accurate models but also lead the way towards a better understanding of solution systems and potential relaxation in the conservatism of the current aqueous plutonium processing limits.

97 MATHEMATICS AND COMPUTING↗

Nuclear Data Testing Of Pu{sup 239} CIELO Evaluation With NDaST

Within the Collaborative International Evaluated Library Organisation (CIELO) project a coordinated effort is being made amongst the different nuclear data evaluation projects, ENDF, JEFF, JENDL etc. to improve the cross sections of six of the most important isotopes, Pu{sup 239}, U{sup 235}, U{sup 238}, Fe{sup 56}, O{sup 16} and H{sup 1}. Recently developed, the Nuclear Data and Sensitivity Tool (NDaST) is an online tool (http://www.oecd-nea.org/ndast/) that allows nuclear data evaluators to get rapid feedback about the consequences of changes to nuclear data on integral experiment benchmarks that exist within the International Criticality Safety Benchmark Evaluation Project (ICSBEP) and International Reactor Physics Evaluation (IRPhE) Project handbooks. NDaST links the thousands of nuclear data sensitivity profiles in the Database for ICSBEP (DICE) and the IRPhE Database and Analysis Tool (IDAT), with the nuclear data viewing tool JANIS. NDaST can be used to provide timely feedback to CIELO participants. Normally an evaluator changes the ENDF/B files based on differential data, and subsequently hands the new evaluation to testers who give feedback on the performance of the new evaluation in terms of accurately predicting the integral benchmark results. This process is often slow. With accurate sensitivity coefficients it is feasible to predict the results of changes to differential data without performing the direct substitution, by simply multiplying the change in cross section with the sensitivity. Furthermore, when multiple aspects of the file are changed simultaneously, the impact of each individual change can be muddled in the substitution testing. NDaST when used in conjunction with direct perturbation testing can help provide feedback as to which cross section changes are driving changes in the benchmarks. In this paper we focus on Pu{sup 239}, and comparing the NDaST predictions of CIELO files to direct substitution. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Quantification of calculation accuracy for code systems in burn-up credit applications by recalculations of experimental data - 14480

For application in criticality safety, numerical code systems require profound validation against experimental data. In terms of burn-up credit, this refers to the inventory determination as well as the subsequent criticality calculation. Within this framework, a dedicated, conservative estimation of uncertainties, bias and bias uncertainties for the resulting calculated multiplication factor k{sub eff} is indispensable. However, measures to reduce excess conservatism may become desirable, depending on the application case. For this reason GRS implemented a methodology to validate a calculation code system for criticality safety analyses for systems with irradiated nuclear fuel. The work at hand demonstrates this methodology by means of the GRS home-built inventory determination system KENOREST and ORNL's well-known SCALE 6 CSASS criticality safety calculation sequence. A number of 40 radiochemical analysis samples taken from SFCOMPO and elsewhere have been calculated to derive isotopic correction factors in different ways, depending on the required level of conservatism and the calculational efforts to be carried out. This includes bounding methods as well as different Monte Carlo sampling approaches. Furthermore, from the ICSBEP a number of 515 critical benchmark experiment configurations comprising water moderated low enriched UO{sub 2} fuel rods and water moderated mixed oxide (MOX) fuel rods have been selected and evaluated. Important absorber and structure materials are also covered. Various trending and sensitivity and uncertainty analysis methods have been applied, again to derive conservative estimates on the various contributions to k{sub eff} uncertainties. The overall methodology is applicable to low enriched, water moderated PWR uranium dioxide fuels in a burn-up range of about 10 to 60 GWd/tHM, and validates the reactivity contributions of the major uranium and plutonium isotopes. The methodology itself has no limitation which requires the exclusion of further isotopes as e.g. fission products. However, its application is constrained by the experimental database being publicly available. After the potential provision of an extended database in the future, the range of applicability can easily be extended to more nuclides. In addition, it is not limited to the code systems being used here but can also be applied using different numerical tools. For a generic PWR spent fuel pool rack and different enrichment and burn-up combinations, the impact of the current level of validation on k{sub eff} is demonstrated and quantified. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validating Mixtures of 233 U, 235 U, and 239 Pu for the Sum-of-Fractions Method

The Sum-of-Fractions method is a technique used to assure that homogeneous mixtures of fissile and fissionable isotopes are below a minimum margin of k eff or reactivity. Current work by Pacific Northwest National Laboratory examines different mixtures of 233 U, 235 U, and 239 Pu to determine critical mass limits for mixtures of transuranic actinides lacking a validation basis. To provide a validation basis for these limits, the work presented here describes the results of a sensitivity and uncertainty analysis of various mixtures of these isotopes in various concentrations moderated and reflected by light water and polyethylene. The TSUNAMI-1D sequence in the SCALE code system was used to generate sensitivity coefficients for three different concentrations of mixtures of 233 U, 235 U, and 239 Pu. The TSUNAMI-IP sequence was then used for similarity assessment (c k ) with critical benchmark experiment sensitivity data files (SDFs) from the Oak Ridge National Laboratory Verified, Archived Library of Inputs and Data and the Nuclear Energy Agency SDF database. The VADER sequence in SCALE was used for statistical testing and to generate upper subcritical limits from the data to develop a basis for validating critical mass limits.

07 ISOTOPE AND RADIATION SOURCES↗

Benchmark of the Chlorine Worth Study Experiments in Support of Chlorine Nuclear Data Validation for Nuclear Criticality Safety

The Chlorine Worth Study (CWS) was a critical experiment to address an urgent need for thermal chlorine nuclear data validation in plutonium systems. This urgent need is tied directly to plutonium recycle and recovery operations in the plutonium facility at Los Alamos National Laboratory, where exceptionally conservative criticality safety limits are used because no credit is taken for the neutron capture by chlorine. The experiment used weapons-grade plutonium metal plates clad in stainless steel, known as the PANN (plutonium aluminum no nickel) ZPPR (zero power physics reactor) plates. The plutonium was reflected and moderated by high-density polyethylene and included combinations of polyvinyl chloride (PVC) and chlorinated polyvinyl chloride (CPVC) as absorbers. The experiment and benchmark included three configurations mimicking 30 g 239 Pu/L plutonium, 300 g 239 Pu/L plutonium, and 600 g 239 Pu/L plutonium in an aqueous chloride solution. Uncertainties in the benchmark included five broad categories: (1) criticality measurement, (2) mass and density, (3) dimensions, (4) material compositions, and (5) positioning. The largest contribution to the overall uncertainties for all three cases came from the material compositions, in particular the PVC and CPVC absorber compositions. A detailed model was created to be a near match (that is within expectations of transport code users) and a simplified model was created to minimize offset dimensions and expedite modeling for code validation. Sample calculations were completed in MCNP6.3 with ENDF/B-VIII.0 and ENDF/B-VII.1 nuclear data. For the detailed and simplified models, the average difference between the computed and experimental k eff was 951 pcm. CWS will serve as the key validation experiment for nuclear criticality safety in support of aqueous chloride operations. The sensitivity to the chlorine capture cross section is orders of magnitude greater than other existing benchmarks. The current limits, as defined by nuclear criticality safety, are 520 g Pu per batch, i.e. the minimum critical mass of the Pu solution infinitely reflected by water [Criticality Handbook: Volume II, (1969)]. This extremely conservative critical mass limit does not credit any neutron capture by chlorine (in particular neutron capture by 35 Cl) and greatly impedes the throughput required for current and future operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verifying MCNP Models of the TEX High 240 Plutonium Benchmark

Computational modeling programs are invaluable tools that allow us to understand systems, safely develop new processes, and make reliable predictions about future designs. However, the effectiveness of these codes is limited by the degree to which their parameters match the real world. In the field of nuclear engineering, cross section data is one of these vital parameters. Accurate cross section data on important fissile and fissionable isotopes promotes the design of safer and more efficient fabrication, transportation, storage, and stockpiling of nuclear fuel. Unfortunately, there are knowledge gaps in data on key isotopes. In 2011, a multinational meeting hosted by the US Department of Energy Nuclear Criticality Safety Program ranked the priority of certain cross section data needs. In response, Lawrence Livermore National Lab (LLNL) designed the Thermal and Epithermal eXperiment (TEX) series of benchmark experiments. Benchmark experiments are used to validate current cross section data. They validate data by comparing the results of an actual experiment to the predicted results from a computational model. The data a benchmark applies to depends on the isotope and energy range the experiment’s neutron multiplication factor ( k eff ) is most sensitive to. The development and testing of the TEX High 240 Plutonium Benchmark will help validate 240 Pu cross section data. The configuration and materials of this benchmark are designed to be most sensitive to 240 Pu's intermediate energy range (from 0.625 ev to 100 keV ). MCNP® models of the assembly have been developed by LLNL and the results have been written in the final design report. In order for the discrepancies between benchmark models and experiments to be attributed to cross section inaccuracies, the accuracy of the models needs to be verified. The goal of this project is to verify of the results of LLNL's modeling by creating a new set of MCNP models and comparing the results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data Testing with Zero Power Reactor (ZPR), Zero Power Physics Reactor (ZPPR), and New Thermal Epithermal eXperiments (TEX) Plutonium Benchmarks [Slides]

This presentation states that new TSLs in ENDF/B-VIII.0 will reduce the overprediction of the library for the most moderated cases. The differences between VII.1 and VIII.0 are driven by the 239 Pu changes and are consistently higher for all configurations. The VIII.0 239 Pu thermal cross sections were specifically adjusted lower to better predict plutonium thermal solutions criticality benchmarks, yet they overpredict the TEX thermal configurations, moderated by PE. Other, smaller differences have been seen for 240 Pu and 56 Fe. PMM-002 has shown utility in testing cross sections over a wide range of neutron energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benchmark Shock Tube Experiments for Radiative Heating Relevant to Earth Re-Entry

Detailed spectrally and spatially resolved radiance has been measured in the Electric Arc Shock Tube (EAST) facility for conditions relevant to high speed entry into a variety of atmospheres, including Earth, Venus, Titan, Mars and the Outer Planets. The tests that measured radiation relevant for Earth re-entry are the focus of this work and are taken from campaigns 47, 50, 52 and 57. These tests covered conditions from 8 km/s to 15.5 km/s at initial pressures ranging from 0.05 Torr to 1 Torr, of which shots at 0.1 and 0.2 Torr are analyzed in this paper. These conditions cover a range of points of interest for potential fight missions, including return from Low Earth Orbit, the Moon and Mars. The large volume of testing available from EAST is useful for statistical analysis of radiation data, but is problematic for identifying representative experiments for performing detailed analysis. Therefore, the intent of this paper is to select a subset of benchmark test data that can be considered for further detailed study. These benchmark shots are intended to provide more accessible data sets for future code validation studies and facility-to-facility comparisons. The shots that have been selected as benchmark data are the ones in closest agreement to a line of best fit through all of the EAST results, whilst also showing the best experimental characteristics, such as test time and convergence to equilibrium. The EAST data are presented in different formats for analysis. These data include the spectral radiance at equilibrium, the spatial dependence of radiance over defined wavelength ranges and the mean non-equilibrium spectral radiance (so-called 'spectral non-equilibrium metric'). All the information needed to simulate each experimental trace, including free-stream conditions, shock time of arrival (i.e. x-t) relation, and the spectral and spatial resolution functions, are provided.