Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Power Layout Design of a GaN HEMTs-Based High-Power High-Efficiency Three-Level ANPC Inverter for 800 V DC Bus System

Multiple commutation paths exist for switching devices in a three-level active neutral point clamped (3L-ANPC) inverter operation based on the selected switching state and current direction. In addition, the capacitive coupling path of the nonswitching device is a key design aspect for enabling high voltage and high current operation of gallium nitride (GaN) switches in 3L-ANPC topology. A comprehensive study of the switching transient events of inner, outer, and clamping devices of 3L-ANPC is presented in this article. The commutation mechanisms for worst-case transient voltage overshoots (TVOs) are identified. A simplified equivalent circuit model is presented to determine the design criteria for the power layout structure's parasitic inductances. A power layout strategy satisfying the design criteria is then proposed using an insulated metal substrate power printed circuit board (PCB) to enable efficient high-power operation. The proposed design minimizes the commutation and capacitive coupling path inductances to 6 nH and 11.5 nH, respectively. This enables the fast switching operation of GaN HEMTs at 800 V dc, 36 A with a low TVO of 31% verified through experimental three-level double pulse test results. Experimental evaluation of a three-phase 3L-ANPC hardware prototype based on the proposed power layout shows 99% efficiency at 800 V, 9.5 kVA and 50 kHz switching frequency. The proposed design achieves a low case-to-ambient thermal resistance of 2.3 °C/W.

42 ENGINEERING↗

Measuring Bus Frequency During Transients: Some Fundamentals

The success of digital instruments seems sometimes to founder when it comes to frequency measurement. Measurement science has developed certain broad principles over the centuries. They are so deep-rooted they are sometimes overlooked. The paper defines measurement largely by elucidating some of these broad principles, and defines frequency, a word subject to much interpretation, as a mathematical entity. Methods of measuring frequency are discussed. An example of the behavior of frequency during a fault, measured in accordance with all the basic principles, is given. The results are not particularly useful. Methods of improving the usefulness are discussed, but may violate some of the basic principles. In essence, “frequency” may not be the best measurand for a signal obtained during a fault.

Frequency, measurement, model, representational, o↗

ML-Based Power System Stability Assessment Considering Network Topology Changes: WECC 20,000+ Bus System Case Study

Modern power grids are fast-changing and thus require real-time monitoring and online stability assessment. With the rapid development of machine learning (ML) techniques, using data-driven models to provide fast and accurate estimations of power system stability marginal information, such as frequency nadir for frequency stability and critical clearing time (CCT) for transient stability, have become possible. However, despite the numerous research on ML-based methods for frequency nadir and CCT prediction, there is limited work on the impact of different network topology changes. Furthermore, most previous studies only focused on small or synthetic systems, and there is a lack of research on actual large power system models. In this paper, the above issues are addressed by studying the actual U.S. Western Electricity Coordinating Council (WECC) system model with more than 20,000 buses. Massive simulations are conducted in PowerWorld Simulator to study the impact of various topology change scenarios on both frequency stability and transient stability. System operating information is extracted from the success dispatch cases of various network topologies to generate a comprehensive dataset for ML-based models. Two ML methods, random forest (RF) and multilayer perceptron (MLP) neural network, are trained and tested for both frequency nadir prediction and CCT prediction. Test results have proven the models are capable of online stability assessment for large power networks such as the WECC system with sufficient accuracy.

critical clearing time↗

An Interleaved Reduced-Component-Count Multivoltage Bus DC/DC Converter for Fuel Cell Powered Electric Vehicle Applications

An interleaved reduced-component-count dc/dc converter is proposed for power management in fuel cell powered vehicles with a multivoltage electric net. The converter is based on a simplified topology and can handle more power with less ripple current, therefore reducing the capacitor requirements, making it more suited for fuel cell powered vehicles in the near future. A prototype rated at 4.3 kW was built and tested to verify the proposed topology.

30 DIRECT ENERGY CONVERSION↗

Safety Design Strategy for the Advanced Test Reactor Diesel Bus (E-3) and Switchgear Replacement Project

In accordance with the requirements of U.S. Department of Energy (DOE) Order 413.3B, “Program and Project Management for the Acquisition of Capital Assets,” safety must be integrated into the design process for new or major modifications to DOE Hazard Category 1, 2, and 3 nuclear facilities. The intended purpose of this requirement involves the handling of hazardous materials, both radiological and chemical, in a way that provides adequate protection to the public, workers, and the environment. Requirements provided in DOE Order 413.3B and DOE Order 420.1B, “Facility Safety,” and the expectations of DOE-STD-1189-2008, “Integration of Safety into the Design Process,” provide for identification of hazards early in the project and use of an integrated team approach to design safety into the facility. This safety design strategy provides the basic safety-in-design principles and concepts that will be used for the Advanced Test Reactor Reliability Sustainment Project. While this project does not introduce new hazards to the ATR, it has the potential for significant impacts to safety-related systems, structures, and components that are credited in the ATR safety basis and are being replaced. Thus the project has been determined to meet the definition of a major modification and is being managed accordingly.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterization of throughput on the AXI DMA bus for burst data transfer over Ethernet

cThe Xilinx AXI Direct Memory Access (AXI DMA) module is an efficient solution for medium-speed data transfer in Xilinx SoC FPGAs, supporting data rates greater than 1000 Gbps even in very suboptimal operating modes. It facilitates direct transfer of AXI stream data into processor memory without constant software intervention, which reduces overhead and ensures consistent data logging. By utilizing the FPGA's available memory, large circular buffers (1-5 GiB) are used to buffer data and accommodate network limitations, enabling high-rate data bursts. In this study, we measured the performance of AXI DMA under conditions simulating its lowest practical data transfer speeds. The Arbitrary Length Data Sender was used to transmit AXI stream packets at 32-bit width and 100 MHz frequency, a narrow width and slow speed. Results show that the AXI DMA can transfer up to 3192.76 Mbps with large packet sizes but experiences reduced performance for smaller packets, as low as 2.6 Mbps for 4-byte packets. For Ethernet-limited applications, packet sizes between 8,000 and 16,000 bytes provided optimal transfer speeds of 874 to 1600 Mbps. These findings suggest that the AXI DMA is not the limiting factor in systems where packet sizes exceed 8,000 bytes.

43 PARTICLE ACCELERATORS↗

A Review of Regulations, Codes, and Standards for Hydrogen Fuel Cell Electric Bus Use on Airports

This report reviews regulations, codes, and standards to be considered for FCEB operations on airports governing vehicle safety, hydrogen infrastructure, and airport operations. Overall, the review found the existing regulatory framework largely suitable for FCEB operations on airports, with only minor gaps identified pertaining to heavy-duty vehicle fueling, operation and fire safety on airport aprons, and authorization for emergency power use.

08 HYDROGEN↗

Thermal Analysis of the Bus Bars for the 800MeV Injection Era

❑ Introduction ❑COMSOL thermal simulations for present conditions - Results - Validation ❑COMSOL thermal simulations for PIP-II conditions ❑Proposed changes - New busbars section - Results ❑Peak temperature tables ❑Conclusions

Picchi, Silvia↗

Feasibility and Qualitative Risk Assessment of Fuel Cell Electric Bus Use for Emergency Backup Power for Airport Applications

Airports rely on robust backup power systems to maintain critical operations during emergencies. This paper investigates the feasibility of using hydrogen fuel cell electric buses (FCEBs) as emergency backup power sources, focusing on their technical specifications, operational challenges, and associated risks. Using Portland International Airport as a case study, the analysis evaluates the power output and hydrogen consumption of New Flyer’s 40’ Xcelsior Charge fuel cell buses, to provide power for key airport systems. Additionally, the paper explores the design and layout of how FCEBs can be connected to airport facilities, and addresses safety considerations, hydrogen supply logistics, and electrical compatibility. While FCEBs present significant advantages in terms of sustainability and resilience, their implementation requires careful planning, infrastructure investment, and adherence to safety standards. This research provides actionable insights for airport stakeholders seeking to transition to hydrogen-based backup power system.

08 HYDROGEN↗

Edge ML for CAN bus intrusion detection in AVs

Autonomous Vehicles (AVs) are revolutionizing transportation, but their reliance on interconnected cyber-physical systems exposes them to unprecedented cybersecurity risks. This study addresses the critical challenge of detecting real-time cyber intrusions in self-driving vehicles by leveraging a dataset from the Udacity self-driving car project. We simulate four high-impact attack vectors, Denial of Service (DoS), spoofing, replay, and fuzzy attacks, by injecting noise into spatial features (e.g., bounding box coordinates) to replicate adversarial scenarios. We develop and evaluate two lightweight neural network architectures (NN-1 and NN-2) alongside a logistic regression baseline (LG-1) for intrusion detection. The models achieve exceptional performance, with NN-2 attaining an AUC score of 93.15% and 93.15% accuracy, demonstrating their suitability for edge deployment in AV environments. Through explainable AI techniques, we uncover unique forensic fingerprints of each attack type, such as spatial corruption in fuzzy attacks and temporal anomalies in replay attacks, offering actionable insights for feature engineering and proactive defense. Visual analytics, including confusion matrices, ROC curves, and feature importance plots, validate the models' robustness and interpretability. This research sets a new benchmark for AV cybersecurity, delivering a scalable, field-ready toolkit for Original Equipment Manufacturers (OEMs) and policymakers. By aligning intrusion fingerprints with SAE J3061 automotive security standards, we provide a pathway for integrating machine learning into safety-critical AV systems. Our findings underscore the urgent need for security-by-design AI, ensuring that AVs not only drive autonomously but also defend autonomously. This work bridges the gap between theoretical cybersecurity and life-preserving engineering, offering a leap toward safer, more secure autonomous transportation.

97 MATHEMATICS AND COMPUTING↗