PACE OCI Lunar Calibration: Initial Results

Launched in February 2024, the Ocean Color Instrument (OCI) onboard NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission has started performing its monthly lunar calibrations at ±7degreeslunar phase angle in March 2024. In this paper, we will describe the OCI lunar calibration methodology and show the results of lunar calibration events during the initial months of PACE/OCI operation. A key difference of OCI lunar calibration from heritage sensors is that the lunar disk integrated irradiance is computed from lunar pixel radiance and sampling distance instead of the instrument’s IFOV. PACE provided a near constant sweep rate during lunar calibration allowing accurate determination of OCI pixel sampling extent. OCI performs lunar calibration in baseline science mode with 282 hyperspectral bands from 315 –895 nm and 7 shortwave infrared bands(940 -2260 nm). For each OCI band, we compute the integrated lunar disk irradiance, and compare the result with a lunar irradiance model (ROLO)prediction. The early results presented here clearly show that OCI’s lunar image acquisition is working as intended and will provide accurate data for OCI’s on-orbit radiometric characterization. The hyperspectral lunar irradiances provided by OCI are expected to become a valuable data set for the evaluation of lunar irradiance models.

calibration↗

Spatiotemporal Automatic Calibration of Infrastructure Lidar, Radar, and Camera with a Global Navigation Satellite System: Preprint

Robust and accurate perception is important for modern intelligent transportation systems (ITS), which use sensors of various modalities for data fusion to create a digital twin of an intersection. Sensor calibration is an important process that creates a unified coordinate frame for the sensor output data so that it can be used for data fusion. Classical approaches for sensor calibration are time-consuming, require an overlapping field of view for feature matching, and are not feasible for ITS application as they cause disruptions in the flow of traffic. In this paper, we present a spatiotemporal automatic calibration approach to calibrate multiple infrastructure lidar, radar, and cameras installed at a traffic intersection. The approach uses global navigation satellite system (GNSS) positioning information shared by connected vehicles, and when the vehicle is detected by the sensor, we match the sensor detections with the GNSS coordinates. The proposed algorithm is evaluated with a real-world dataset utilizing detections from two radars, cameras, and lidars with a test vehicle instrumented with a post-processing kinematic (PPK)-corrected GNSS driving past the sensors installed at a four-way traffic intersection. The experimental results show that the proposed automatic calibration approach can achieve the transformation with a root mean squared error of less than 0.5 for radar and lidar and less than 2 for camera detections. The ability to rapidly calibrate sensors not only benefits initial installations, but can also be used for system health monitoring, while utilizing available connected vehicle data to test the real-time sensor fidelity and operational status.

ADVANCED PROPULSION SYSTEMS↗

Application of Indirect Quantification of 133mXe to Calibration of HPGe Detector

The INL Noble Gas Laboratory provides intercomparison samples for the noble gas analysis laboratories as part of the CTBTO PrepCom IMS. Xe-133m is one of the four relevant radionuclides in nuclear explosion monitoring. Without commercially available Xe-133m calibration standards laboratories must create and improve calibration methods. Improvements in calibration methods at the INL NGL benefit the CTBTO PrepCom through better certified values for Xe-133m intercomparison samples. Calibration of High Purity Germanium detectors for Xe-133m quantification is complicated by the coexistence of Xe-133 in samples under analysis. Xe-133 is typically produced in larger quantities, has higher gamma emission probabilities, and its gammas are detected more efficiently than Xe-133m. Xe-133m activity of samples can be indirectly inferred through the 133:133m activity ratio of a batch of material, and the Xe-133 counts in the assay of a small aliquot of the same material. This indirect quantification method can be leveraged to perform detector calibrations for quantification of Xe-133m. Calibrations can be performed by inferring the Xe-133m to certify the sample, and direct counting to determine detector efficiency. A comparison of method results will be shown.

133mXe↗

Emulator-based Bayesian calibration of a subglacial drainage model

Subglacial drainage models, often motivated by the relationship between hydrology and ice flow, sensitively depend on numerous unconstrained parameters. We explore using borehole water-pressure time series to calibrate the uncertain parameters of a popular subglacial drainage model, taking a Bayesian perspective to quantify the uncertainty in parameter estimates and in the calibrated model predictions. To reduce the computation time associated with Markov Chain Monte Carlo sampling, we construct a fast Gaussian process emulator to stand in for the subglacial drainage model. We first carry out a calibration experiment using synthetic observations consisting of model simulations with hidden parameter values as a demonstration of the method. Using real borehole water pressures measured in western Greenland, we find meaningful constraints on four of the eight model parameters and a factor-of-three reduction in uncertainty of the calibrated model predictions. These experiments illustrate Gaussian process-based Bayesian inference as a useful tool for calibration and uncertainty quantification of complex glaciological models using field data. However, significant differences between the calibrated model and the borehole data suggest that structural limitations of the model, rather than poorly constrained parameters or computational cost, remain the most important constraint on subglacial drainage modelling.

58 GEOSCIENCES↗

Machine Learning Calibration of Groundwater Table Depth in ELM: Impact on Land Surface Hydrology and Land‐Atmosphere Fluxes

Accurate representation of groundwater table depth (GWTD) is crucial for simulating hydrological cycling in Earth system models (ESM). Nevertheless, there is a notable gap in the literature regarding the validation of GWTD simulations in ESMs and their subsequent impact on downstream hydrological components. This study explores the calibration of parameterization of global GWTD using machine learning within the Energy Exascale Earth System Model (E3SM) Land Model (ELM). Despite achieving significant gains in simulating GWTD through calibration, offline ELM simulations unexpectedly show that these improvements do not translate to substantial enhancements in model performance for other key hydrological variables, including soil moisture (SM), runoff, groundwater contribution to runoff or base flow index (BFI), and evapotranspiration and its partitioning. The performance in SM and runoff was even degraded in some regions, while BFI was mostly overestimated. Although there is significant improvement in GWTD within the critical range of 1–5 m, where groundwater traditionally influences land surface energy fluxes, these improvements occurred mostly in humid areas where the impact of GWTD on surface processes is minimal. Although the impacts of model calibration are generally small in offline ELM simulations, coupled land-atmosphere simulations exhibit much stronger responses to GWTD calibration, highlighting the role of land-atmosphere feedbacks in Earth system modeling. These findings underscore the need for integrated calibration strategies that simultaneously optimize multiple hydrological variables. However, if a single-variable approach is necessary, it is crucial to establish clear priorities for calibration, identifying the most critical variables that have the greatest impact on overall model performance.

Fang, Yilin [Pacific Northwest National Laboratory↗

Calibrating a finite-strain phase-field model of fracture for bonded granular materials with uncertainty quantification

To study the mechanical behavior of mock high explosives, an experimental and simulation program was developed to calibrate, with quantified uncertainty, a material model of the bonded granular material Idoxuridine and nitroplasticized Estane-5703. This paper reports on the efficacy of such a framework as a generalizable methodology for calibrating material models against experimental data with uncertainty quantification. Additionally, this paper studies the effect of two manufacturing temperatures and three initial granular configurations on the unconfined compressive behavior of the resulting bonded granular materials. In each of these cases, the same calibration framework was used; in that, hundreds of high-fidelity direct numerical simulations using a new, graphics processing unit-enabled, high-performance finite element method software, Ratel, were run to calibrate a finite-strain phase-field fracture model against experimental data. It was found that manufacturing temperature influenced the elastic response of the mock high explosives, with higher temperatures yielding a stiffer response. By contrast, it was found that the initial configuration of the grains had a negligible impact on the overall behavior of the mock high explosives though it remains possible that local damage accumulation within the specimens could be altered by the initial configurations. Overall, the calibration framework was successful at creating well-calibrated models, showing its usefulness as an engineering and scientific tool.

36 MATERIALS SCIENCE↗

Full calibration of the tomographic redshift distribution from the HSC PDR3 Shape Catalog with DESI

The calibration of tomographic redshift distributionsis essential for cosmological analysis of weak lensing data.In this work, we calibrate all four tomographic bins of the Hyper Suprime Camera (HSC) weak lensing catalog with the Dark Energy Spectroscopic Instrument (DESI) Data Release 1 and 2 using the clustering redshifts technique. We include z > 1.2 redshift sources such as emission line galaxies (ELG) and quasars (QSO) sources in our calibration, which were not available in the previous HSC calibration (Rau et al. (2022), Mon. Not. Roy. Astron. Soc. 524 (2023) 5109), allowing a complete calibration of all the redshift bins. We find the first tomographic bin exhibits a small shift towards low redshifts. The second bin is in good agreement with the photometric calibration, while third and fourth bin exhibit a shift towards higher redshifts. However, these shifts are considerably smaller than the shifts obtained in the HSC Year 3 cosmic shear analyses. We evaluate the impact of galaxy bias and magnification effects from all the samples on the measurements, finding them to be small, and we propose corrections to reduce them further. Specifically, we relax the assumption of linear bias and only assume no redshift evolution of the cross-correlation coefficient, allowing us to leverage smaller clustering scales. We model the redshift distributions with splines and compare our results to previous analyses as well as to other parameterizations found in literature. For the two high-redshift tomographic bins, we find the shifts to higher redshifts with respect to the measurements performed in Rau+2022 to be Δz$_{3}$ =-0.039$^{+0.020}$$_{-0.021}$ and Δz$_{4}$ = -0.048$^{+0.012}$$_{-0.012}$.

Choppin de Janvry, J. [LBL, Berkeley; UC, Berkeley↗

Frequency-Selectable Laser Source (FLS) Calibrator for CMB Bandpass Characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from our detector bandpass calibration. Uncertainties in bandpass can severely limit our measurements by limiting foreground removal and spectral fitting, which is particularly important for high-$\ell$ observations like cluster science using the Sunyaev-Zeldovich (SZ) effect. Currently, CMB experiments typically use a Fourier Transform Spectrometer (FTS) to measure the detector bandpasses. However, the resolution of the FTS is dependent on the length of the interferometer arms, leading to a need for increasingly large FTS instruments as CMB experiments require tighter constraints on detector bandpasses. Additionally, systematic effects like shifts in bandpass shape from uneven illumination from the FTS further limit the calibration uncertainties. As a complement to the FTS, we have developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency housed in a calibrator that allows for varying degrees of laser power attenuation. We present several tests used to characterize the first prototype design of the FLS calibrator, as well as the improvements to the calibrator design currently underway.

Saunders, Lauren [Fermilab]↗

Measurement and calibration of non-linear shear terms in galaxy cluster fields

Introduction Galaxy cluster lensing is a powerful tool for measuring the mass of galaxy clusters, but accurate shear measurement and calibration are critical to obtaining reliable results. This study focuses on the measurement and calibration of weak lensing shears to improve mass estimates in cluster lensing. To deal with the problem, we first developed an image simulation pipeline, jedisim, which utilizes galaxy images extracted from the Hubble Space Telescope (HST) Ultra Deep Field (UDF) and the Cosmic Assembly Near-infrared Deep Extragalactic Legacy Survey (CANDELS). Methods The simulations represent realistic galaxy distributions and morphologies as input sources. The foreground halo with a Navarro–Frenk–White (NFW) profile is constructed such that the lensing signals of background galaxies can be measured by the Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST) Science Pipelines. By comparing the measured reduced shear g meas and the true reduced shear g true , we observe non-linearity up to g ≲ 0.6 . We fit polynomials to the data with quadratic correction adequate to g ≲ 0.4 . Meanwhile, we conduct mass estimates using the pzmassfitter code on four different clusters. Results The mass estimate results are significantly improved after applying the shear calibration derived from the present work—from 4.954 ± 0.504 × 1 0 14 M ⊙ to 10.507 ± 0.498 × 1 0 14 M ⊙ after calibration for a simulated cluster with the mass of 10 × 1 0 14 M ⊙ . In multiple cases of validation, the estimated results are all consistent with true cluster mass. Discussion This study yields the first relationship between reality and shape measurement of the LSST Science Pipelines and serves as the first step toward the overall goal of mass calibration in cluster lensing. By addressing the challenges in shear measurement and calibration, we aim to enhance the accuracy and reliability of mass estimates in galaxy cluster lensing studies.

Astronomy & Astrophysics↗

Development of an in situ calibration technique for combustible gas detectors

This paper describes the development of an in situ calibration procedure for combustible gas detectors (CGD). The CGD will be a necessary device for future space vehicles as many subsystems in the Environmental Control/Life Support System utilize or produce hydrogen (H2) gas. Existing calibration techniques are time-consuming and require support equipment such as an environmental chamber and calibration gas supply. The in situ calibration procedure involves utilization of a water vapor electrolysis cell for the automatic in situ generation of a H2/air calibration mixture within the flame arrestor of the CGD. The development effort concluded with the successful demonstration of in situ span calibrations of a CGD.

Shumar, J. W.↗

A procedure for accurate calibration of the orientation of the three sensors in a vector magnetometer

Procedures are described for the calibration of a vector magnetometer of high absolute accuracy. It is assumed that the calibration will be performed in the magnetic test facility of Goddard Space Flight Center (GSFC). The first main section of the report describes the test equipment and facility calibrations required. The second presents procedures for calibrating individual sensors. The third discusses the calibration of the sensor assembly. In a final section recommendations are made to GSFC for modification of the test facility required to carry out the calibration procedures.

Mcpherron, R. L.↗

Calibration of transonic and supersonic wind tunnels

State-of-the art instrumentation and procedures for calibrating transonic (0.6 less than M less than 1.4) and supersonic (M less than or equal to 3.5) wind tunnels were reviewed and evaluated. Major emphasis was given to transonic tunnels. Continuous, blowdown and intermittent tunnels were considered. The required measurements of pressure, temperature, flow angularity, noise and humidity were discussed, and the effects of measurement uncertainties were summarized. A comprehensive review of instrumentation currently used to calibrate empty tunnel flow conditions was included. The recent results of relevant research are noted and recommendations for achieving improved data accuracy are made where appropriate. It is concluded, for general testing purposes, that satisfactory calibration measurements can be achieved in both transonic and supersonic tunnels. The goal of calibrating transonic tunnels to within 0.001 in centerline Mach number appears to be feasible with existing instrumentation, provided correct calibration procedures are carefully followed. A comparable accuracy can be achieved off-centerline with carefully designed, conventional probes, except near Mach 1. In the range 0.95 less than M less than 1.05, the laser Doppler velocimeter appears to offer the most promise for improved calibration accuracy off-centerline.

Reed, T. D.↗

Results of the 1974 through 1977 NASA/JPL balloon flight solar cell calibration program

From 1974 through 1977, seven solar cell calibration flights and two R&D flights with a spectroradiometer as a payload were attempted. There were two R&D flights, and one calibration flight that failed. Each calibration flight balloon was designed to carry its payload to an altitude of 36.6 km (120 kft). The R&D flight balloons were designed for a payload altitude of 47.5 km (150 kft). At the end of the flight period, the upper (solar cell calibration system) and lower (consolidated instrument package (DIP) payloads were separated from the balloon and descend via parachutes. The calibrated solar cells recovered in this manner were used as primary intensity reference standards during solar simulator testing of solar cells and solar arrays with similar spectral response characteristics. This method of calibration has become the most widely accepted technique for developing space standard solar cells.

Sidwell, L. B.↗

NASA Metrology and Calibration, 1980

The proceedings of the fourth annual NASA Metrology and Calibration Workshop are presented. This workshop covered (1) review and assessment of NASA metrology and calibration activities by NASA Headquarters, (2) results of audits by the Office of Inspector General, (3) review of a proposed NASA Equipment Management System, (4) current and planned field center activities, (5) National Bureau of Standards (NBS) calibration services for NASA, (6) review of NBS's Precision Measurement and Test Equipment Project activities, (7) NASA instrument loan pool operations at two centers, (8) mobile cart calibration systems at two centers, (9) calibration intervals and decals, (10) NASA Calibration Capabilities Catalog, and (11) development of plans and objectives for FY 1981. Several papers in this proceedings are slide presentations only.

Source record↗

SAR calibration technology review

Synthetic Aperture Radar (SAR) calibration technology including a general description of the primary calibration techniques and some of the factors which affect the performance of calibrated SAR systems are reviewed. The use of reference reflectors for measurement of the total system transfer function along with an on-board calibration signal generator for monitoring the temporal variations of the receiver to processor output is a practical approach for SAR calibration. However, preliminary error analysis and previous experimental measurements indicate that reflectivity measurement accuracies of better than 3 dB will be difficult to achieve. This is not adequate for many applications and, therefore, improved end-to-end SAR calibration techniques are required.

Walker, J. L.↗

Multispectral scanner flight model (F-1) radiometric calibration and alignment handbook

This handbook on the calibration of the MSS-D flight model (F-1) provides both the relevant data and a summary description of how the data were obtained for the system radiometric calibration, system relative spectral response, and the filter response characteristics for all 24 channels of the four band MSS-D F-1 scanner. The calibration test procedure and resulting test data required to establish the reference light levels of the MSS-D internal calibration system are discussed. The final set of data ("nominal" calibration wedges for all 24 channels) for the internal calibration system is given. The system relative spectral response measurements for all 24 channels of MSS-D F-1 are included. These data are the spectral response of the complete scanner, which are the composite of the spectral responses of the scan mirror primary and secondary telescope mirrors, fiber optics, optical filters, and detectors. Unit level test data on the measurements of the individual channel optical transmission filters are provided. Measured performance is compared to specification values.

Source record↗

Heat Capacity Mapping Radiometer (HCMR) data processing algorithm, calibration, and flight performance evaluation

The rationale and procedures used in the radiometric calibration and correction of Heat Capacity Mapping Mission (HCMM) data are presented. Instrument-level testing and calibration of the Heat Capacity Mapping Radiometer (HCMR) were performed by the sensor contractor ITT Aerospace/Optical Division. The principal results are included. From the instrumental characteristics and calibration data obtained during ITT acceptance tests, an algorithm for post-launch processing was developed. Integrated spacecraft-level sensor calibration was performed at Goddard Space Flight Center (GSFC) approximately two months before launch. This calibration provided an opportunity to validate the data calibration algorithm. Instrumental parameters and results of the validation are presented and the performances of the instrument and the data system after launch are examined with respect to the radiometric results. Anomalies and their consequences are discussed. Flight data indicates a loss in sensor sensitivity with time. The loss was shown to be recoverable by an outgassing procedure performed approximately 65 days after the infrared channel was turned on. It is planned to repeat this procedure periodically.

Bohse, J. R.↗

A preliminary investigation of the dynamic force-calibration of a magnetic suspension and balance system

The aerodynamic forces and moments acting upon a magnetically suspended wind tunnel model are derived from calibrations of suspension electro magnet currents against known forces. As an alternative to the conventional calibration method of applying steady forces to the model, early experiences with dynamic calibration are outlined, that is a calibration obtained by oscillating a model in suspension and deriving a force/current relationship from its inertia force and the unsteady components of currents. Advantages of dynamic calibration are speed and simplicity. The two methods of calibration applied to one force component show good agreement.