Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Exploring Uncertainty in Moment Estimation for Small Earthquakes in Southern Nevada Using the Coda Envelope Method

Compiling source parameter estimates for small earthquakes is important both for our understanding of earthquake physics and for accurately assessing earthquake hazard. Reliable source parameter estimates are difficult to achieve for small earthquakes, in part due to our inability to accurately model the relevant physical processes at high frequencies. The coda envelope methodology developed by Mayeda and Walter (1996) and Mayeda et al. (2003) can mitigate this concern and estimate the moment of small earthquakes by determining the parameters that control the shape of the S-wave coda envelope while eliminating path effects by minimizing the scatter between seismic stations. Here, we use an open-source implementation of this technique called the Coda Calibration Tool (CCT; Barno, 2017) to calculate CCT-based moment magnitude estimates of small earthquakes (M L 0–3) in the Rock Valley, Nevada, region within the Nevada National Security Site. The Rock Valley data set is of particular interest because it allows us to explore the changes in uncertainties of the coda calibration method with earthquake size and depth. We found that a consistent linear relationship exists between the local magnitude M L and our coda-derived M w estimates for earthquakes as small as M L 0–3, but that current CCT workflows do not accurately characterize very shallow events. We also demonstrate that the epistemic uncertainty in the apparent stress value assumed by the CCT algorithm can influence magnitude estimates of small earthquakes. In conclusion, these results provide valuable insight into the seismicity of this region, and inform future analysis and modeling efforts for nuclear monitoring and seismic hazard.

58 GEOSCIENCES↗

Calibration of the AVHRR visible and near IR channels using radiances measured over remote ocean areas

An inflight absolute calibration method has been adapted and applied to channel 1 of the AVHRR. The approach is based on AVHRR observations in channels 1, 2 and 4. A rigorous cloud screening is performed, based on the homogeneity of the data in channel 1 and 2 and on the temperature in channel 4. In a combined approach, the off-nadir view satellite count in channel 2 is used to detect the aerosol optical thickness and loading and the count of channel 1 is used to calibrate this channel, based on the predictable Rayleigh scattering component. Water vapor data are used, and the channels are intercalibrated using the ratio between channels 1 and 2 over the glint region.

Vermote, Eric F.↗

Application of Generalized Standard Addition Method and Ultraviolet Spectroscopy to Quantify Electrolytic Depolymerization of Lignin

Industrial lignin waste is an important byproduct of bio-refineries and the paper industry. Depolymerization of this industrial lignin could generate useful aromatic compounds. This group has focused on electrolytic decomposition of biorefinery lignin. To quantify electrolytic decomposition of the lignin in a highly caustic solution, ultraviolet (UV) spectroscopy provides a useful probe. The conversion of the neat lignin to the oxidized products achieved by the electrolytic reactor may be measured by quantifying the amount of unreacted neat lignin that remains in the effluent. Because the properties of electrolytic decomposition products are largely unknown, a useful approach to quantify decomposition of the neat lignin is to use a multivariate calibration method referred to as the generalized standard addition method (GSAM). In this approach, the electrolytic decomposition products represent a background interference and the neat lignin that remains can be quantified. Furthermore, this approach allows the conversion of the neat lignin to be calculated in a solution that is a complex mixture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Self-Calibration of BICEP1 Three-Year Data and Constraints on Astrophysical Polarization Rotation

Cosmic microwave background (CMB) polarimeters aspire to measure the faint B-mode signature predicted to arise from inflationary gravitational waves. They also have the potential to constrain cosmic birefringence, rotation of the polarization of the CMB arising from parity-violating physics, which would produce nonzero expectation values for the CMB's temperature to B-mode correlation (TB) and E-mode to B-mode correlation (EB) spectra. However, instrumental systematic effects can also cause these TB and EB correlations to be nonzero. In particular, an overall miscalibration of the polarization orientation of the detectors produces TB and EB spectra which are degenerate with isotropic cosmological birefringence, while also introducing a small but predictable bias on the BB spectrum. We find that BICEP1 three-year spectra, which use our standard calibration of detector polarization angles from a dielectric sheet, are consistent with a polarization rotation of alpha = −2.77deg +/- 0.86deg (statistical) +/- 1.3deg (systematic). We have revised the estimate of systematic error on the polarization rotation angle from the two-year analysis by comparing multiple calibration methods. We also account for the (negligible) impact of measured beam systematic effects. We investigate the polarization rotation for the BICEP1 100 GHz and 150 GHz bands separately to investigate theoretical models that produce frequency-dependent cosmic birefringence. We find no evidence in the data supporting either of these models or Faraday rotation of the CMB polarization by the Milky Way galaxy's magnetic field. If we assume that there is no cosmic birefringence, we can use the TB and EB spectra to calibrate detector polarization orientations, thus reducing bias of the cosmological B-mode spectrum from leaked E-modes due to possible polarization orientation miscalibration. After applying this "self-calibration" process, we find that the upper limit on the tensor-to-scalar ratio decreases slightly, from r < 0.70 to r < 0.65 at 95% confidence.

three-year↗

Calibration of hydrogen atoms measurement using femtosecond two-photon laser-induced fluorescence

What we believe to be a new calibration method for H-fs-TALIF is proposed, and the ratio of two-photon absorption cross-sections, σ (2) , for atomic hydrogen (H) and krypton (Kr) is determined using the broadband emission of a femtosecond laser system. The estimated ratio of the two-photon absorption cross-sections for H and Kr is σ (2) (Kr)/σ (2) (H) = 0.027 ± 20%, which is nearly twenty times lower than values previously obtained with narrowband nanosecond lasers. This discrepancy highlights the need for independent calibration of TALIF measurements for a specific laser pulsewidth range.

Starikovskiy, Andrey [Princeton Univ., NJ (United ↗

SU-F-BRA-06: Dose Distributions for the CivaSheet Pd-103 Directional Brachytherapy Device

Purpose: A flexible polymer membrane (CivaSheet) has been developed by CivaTech Oncology, Inc. (Research Triangle Park, NC) for permanent brachytherapy. Distributed throughout the array are small plastic disks containing Pd-103 and gold foil shielding on one side to provide a directional dose distribution and facilitate imaging. This study evaluated dosimetry for the CivaSheet. Methods: Manufacturer-provided dimensional and compositional information for the device were compared to physical samples for validation of design information, then entered into the MCNP6 radiation transport code for dosimetry simulations. Three device sizes (6×6, 6×12, or 6×18 disk-arrays) were simulated as the membrane can be custom-sized preceding surgical placement. Dose to water was estimated with 0.01 cm resolution from the surface to 10 cm on both sides of the device. Because this is a novel device with calibration methods under development, results were normalized using DVHs to provide 90% prescription coverage to a plane positioned 0.5 cm from the front surfaces. This same normalization was used for creating isodose distributions. Results: Planar dose distributions of flat CivaSheets were relatively homogeneous with acceptable dose uniformity variations. Differences in the results between the differently sized CivaSheets were not significant. At 0.5 mm, 87% of the target volume was within the therapeutic dose range. Dose hotspots on the CivaSheet forward surfaces were directly above the disks. However, dose hotspots on the rear-facing surfaces were positioned between the disks. Doses in contact with the front surface were similar to those observed for currently available brachytherapy sources. Maximum doses that occurred on the rear surface were approximately 55 times lower than the dose on the front surface. Conclusion: Monte Carlo calculations validated the directional capabilities and advantageous dosimetry of the new Pd-103 brachytherapy device. It appears feasible to re-size the CivaSheet in the operating room with an acceptable variation in prescription dose. Research was supported by CivaTech Oncology, Inc.

60 APPLIED LIFE SCIENCES↗

SU-E-T-453: Image-Guided Patient-Specific Quality Assurance for Multi-Target Single Isocenter Intracranial VMAT Radiosurgery

Purpose: To demonstrate a patient specific, image-guided quality assurance method that tests both dosimetric and geometric accuracy for single-isocenter multiple-target VMAT radiosurgery (SIMT-VMAT-SRS) Method: We used a new film type, EBT-XD (optimal range 0.4–40Gy), and an in-house PMMA phantom having a coronal plane for film and a 0.125 cm3 ionization chamber (IC). The phantom contained fiducial features for kV image guided setup and for accurate film marking. Five patient plans with multiple targets sizes ranging from 3 to 21mm in diameter and prescribed doses from 14 to 18 Gy were selected. Two verification plans were generated for each case with the film plane passing through the center of the largest and smallest targets. For the four largest targets we obtained an IC measurement. For each case, a calibration film was irradiated using a custom designed step pattern. The films were scanned using a flatbed color scanner and converted to dose using the calibration film and the three channel calibration method. Image registration was performed between film and treatment planning system calculations to evaluate the geometric accuracy. Results: The mean registration vector had an average magnitude of 0.47 mm (range from 0.13mm to 0.64 mm). For the four largest targets, the mean ratio of the IC and film measurement to expected dose was 0.990 (range 0.968 to 1.009) and 1.032 (1.021 to 1.046), respectively. The fraction of pixels having gamma index < 1 for criteria of 3%/3mm, 3%/2mm, 3%/1mm was 98.8%, 97.5% and 87.2% before geometric registration and 99.1%, 98.3% and 94.8% after registration. Conclusion: We have demonstrated an image-guided QA method can assess both geometric and dosimetric accuracy. The phantom was positioned with sub-millimeter accuracy. Absolute film dosimetry using EBT-XD film was sufficiently accurate for assessment of dose to multi-targets too small for IC measurement in SRS VMAT plans.

60 APPLIED LIFE SCIENCES↗

SU-E-P-44: The Characteristics and Clinical Application of the ArcCHECK for VMAT Verification

Purpose: To evaluate the characteristics and clinical suitability of the ArcCHECK QA system for VMAT verification. Methods: The intrinsic sensitivity,short and long term reproducibility,dose and dose rate dependence,dose per pulsed dependence,field sizes dependence and directional response of the diodes were measured.The results of the diodes were compared with the measurement results of an ionization chamber and calculated results of TPS. Gamma index (3mm distance to agreement and 3% percentage difference ) was used to analyze the dose difference between the calculation and measurement for random selected 211 verified VMAT plans. Results: The ArcCHECK diodes performed well for all tests except directional dependence, which varies from a minimum of −3.9% (seen only when the beam is incident on the diode at 180°) to a maximum of 7.7% (approximately at 255°). Average gamma analysis passing rates with 3mm/3% for 113 NPC,48 cervical cancer and 50 rectal cancer VMAT plans are 93.5%,95.7% and 97.5%, statistical significance has been found between either two of the groups(t=−12.69∼−4.88,all P<0.01). Conclusion: With proposed calibration method,the ArcCHECK QA system is very suitable for VMAT pretreatment verification,the complexity of VMAT plan is the main factor affecting the passing rate.

60 APPLIED LIFE SCIENCES↗

The Development and Hover Test Application of a Projection Moire Interferometry Blade Displacement Measurement System

Projection moir interferometry (PMI) was employed to measure blade deflections during a hover test of a generic model-scale rotor in the NASA Langley 14x22 subsonic wind tunnel s hover facility. PMI was one of several optical measurement techniques tasked to acquire deflection and flow visualization data for a rotor at several distinct heights above a ground plane. Two of the main objectives of this test were to demonstrate that multiple optical measurement techniques can be used simultaneously to acquire data and to identify and address deficiencies in the techniques. Several PMI-specific technical challenges needed to be addressed during the test and in post-processing of the data. These challenges included developing an efficient and accurate calibration method for an extremely large (65 inch) height range; automating the analysis of the large amount of data acquired during the test; and developing a method to determinate the absolute displacement of rotor blades without a required anchor point measurement. The results indicate that the use of a single-camera/single-projector approach for the large height range reduced the accuracy of the PMI system compared to PMI systems designed for smaller height ranges. The lack of the anchor point measurement (due to a technical issue with one of the other measurement techniques) limited the ability of the PMI system to correctly measure blade displacements to only one of the three rotor heights tested. The new calibration technique reduced the data required by 80 percent while new post-processing algorithms successfully automated the process of locating rotor blades in images, determining the blade quarter chord location, and calculating the blade root and blade tip heights above the ground plane.

Sekula, Martin K.↗

SSME Automated Engine Calibrating System (AECS) alternative algorithm

An algorithm is derived for the real-time calibration of the engine mixture ratio during SSME ground testing. Because currently used calibration methods are post-test operations, there exists no fail-safe way of predicting at what mixture ratio a planned test will run. It is proposed that the algorithm developed here be used as part of an AECS which could ensure that nearly all SSME tests are run at the proper mixture ratio. In this way, AECS has the potential of increasing the efficiency of the SSME ground test program. This algorithm is an alternative to that presented in a previous paper. In addition to the derivation of the algorithm, an overview of this calibration system is presented along with a discussion of a possible single coefficient calibration system and the list of test stand facility instrumentation necessary for AECS implementation.

Greene, William D.↗

Analysis of slags using laser-induced breakdown spectroscopy

The feasibility of laser-induced breakdown spectroscopy (LIBS) for the analysis of gasification slags was investigated by comparing LIBS results to the results of an ICP-OES analyzer. A small amount of slag sample was placed on a piece of double sided adhesive tape attached to a glass microscope slide and analyzed for Al, Ca, Fe, Si, and V which are major elements found in slags. The partial least squares regression (PLS-R) and univariate simple linear regression (SLR) calibration methods indicated that apart from V (accuracy up to + 20%) the accuracy of analysis varies within 0.35–6.5% for SLR and 0.06–10% for PLS-R. A paired-sample t-test within the 95% confidence level yielded p-values greater than 0.05, meaning no appreciable statistical difference was observed between the univariate SLR with internal standardization and the multivariate PLS-R for most of the analytes. From the results obtained in this work, LIBS response varies depending on the element and the technique used for quantitative analysis. Simultaneous use of the univariate calibration curves with internal standard (intensity ratio) and PLS regression in multi-elemental analysis can help reduce the matrix effect of slags associated to their high variation in concentration. Overall, these results demonstrate the capability of LIBS as an alternative technique for analyzing gasification slags. Estimated limits of detection for Al, Ca, Fe, Si and V were 0.167, 0.78, 0.171, 0.243 and 0.01 wt.%, respectively.

36 MATERIALS SCIENCE↗

TU-G-BRD-04: A Round Robin Dosimetry Intercomparison of Gamma Stereotactic Radiosurgery Calibration Protocols

Purpose: The purpose of this multi-institutional study was to compare two new gamma stereotactic radiosurgery (GSRS) dosimetry protocols to existing calibration methods. The ultimate goal was to guide AAPM Task Group 178 in recommending a standard GSRS dosimetry protocol. Methods: Nine centers (ten GSRS units) participated in the study. Each institution made eight sets of dose rate measurements: six with two different ionization chambers in three different 160mm-diameter spherical phantoms (ABS plastic, Solid Water and liquid water), and two using the same ionization chambers with a custom in-air positioning jig. Absolute dose rates were calculated using a newly proposed formalism by the IAEA working group for small and non-standard radiation fields and with a new air-kerma based protocol. The new IAEA protocol requires an in-water ionization chamber calibration and uses previously reported Monte-Carlo generated factors to account for the material composition of the phantom, the type of ionization chamber, and the unique GSRS beam configuration. Results obtained with the new dose calibration protocols were compared to dose rates determined by the AAPM TG-21 and TG-51 protocols, with TG-21 considered as the standard. Results: Averaged over all institutions, ionization chambers and phantoms, the mean dose rate determined with the new IAEA protocol relative to that determined with TG-21 in the ABS phantom was 1.000 with a standard deviation of 0.008. For TG-51, the average ratio was 0.991 with a standard deviation of 0.013, and for the new in-air formalism it was 1.008 with a standard deviation of 0.012. Conclusion: Average results with both of the new protocols agreed with TG-21 to within one standard deviation. TG-51, which does not take into account the unique GSRS beam configuration or phantom material, was not expected to perform as well as the new protocols. The new IAEA protocol showed remarkably good agreement with TG-21. Conflict of Interests: Paula Petti, Josef Novotny, Gennady Neyman and Steve Goetsch are consultants for Elekta Instrument A/B; Elekta Instrument AB, PTW Freiburg GmbH, Standard Imaging, Inc., and The Phantom Laboratory, Inc. loaned equipment for use in these experiments; The University of Wisconsin Accredited Dosimetry Calibration Laboratory provided calibration services.

60 APPLIED LIFE SCIENCES↗

Hybrid interferometric diagnostic for the refractive index measurement across nearly discrete shock waves

The measurement of high temperature gas properties is key for characterizing high speed flows. Nearly discrete changes in density across shock waves, in particular, are difficult to resolve through traditional fringe-counting interferometric methods. Existing techniques for estimating large fringe jumps are either resolution limited or require specialized window configurations. In this Letter, we describe a unique hybrid interferometric technique that combines narrowband fringes for high resolution and broadband fringes as an absolute reference to measure changes in refractive index with a resolution of up to 7 × 10 −8 across nearly discrete index changes of up to 1.5 × 10 −4 . By capturing fringes with an ultrahigh-speed camera, the refractive index changes across discrete shock fronts can be estimated inside a shock tube with high accuracy and time resolution. First, a novel hybrid calibration method for tracking finite fringes is discussed. Next, this technique is used to measure the post-initial-shock refractive indices for Mach 2.7 to 4.2 flows (pressures from 90.4 to 228.4 kPa). Results are then compared with theoretical values showing agreement within 2%.

Wang, Gwendolyn T. (ORCID:000000016271893X)↗

Comparison and calibration of dose delivered by 137 Cs and x-ray irradiators in mice

Objective. The Office of Radiological Security, U.S. Department of Energy's National Nuclear Security Administration, is implementing a radiological risk reduction program which seeks to minimize or eliminate the use of high activity radiological sources, including 137 Cs, by replacing them with non-radioisotopic technologies, such as x-ray irradiators. The main goal of this paper is to evaluate the equivalence of the dose delivered by gamma- and x-ray irradiators in mice using experimental measurements and Monte Carlo simulations. We also propose a novel biophantom as an in situ dose calibration method. Approach. We irradiated mouse carcasses and 3D-printed mouse biophantoms in a 137 Cs irradiator (Mark I-68) and an x-ray irradiator (X-Rad320) at three voltages (160 kVp, 225 kVp and 320 kVp) and measured the delivered radiation dose. A Geant4-based Monte Carlo model was developed and validated to provide a comprehensive picture of gamma- and x-ray irradiation in mice. Main Results. Our Monte Carlo model predicts a uniform dose delivered in soft-tissue for all the explored irradiation programs and in agreement with the absolute dose measurements. Our Monte Carlo model shows an energy-dependent difference between dose in bone and in soft tissue that decreases as photon energy increases. Dose rate depends on irradiator and photon energy. We observed a deviation of the measured dose from the target value of up to –9% for the Mark I-68, and up to 35% for the X-Rad320. The dose measured in the 3D-printed phantoms are equivalent to that in the carcasses within 6% uncertainty. Significance. Our results suggest that 320 kVp irradiation is a good candidate to substitute 137 Cs irradiation barring a few caveats. There is a significant difference between measured and targeted doses for x-ray irradiation that suggests a strong need for in situ calibration, which can be achieved with 3D-printed mouse biophantoms. A dose correction is necessary for bone doses, which can be provided by a Monte Carlo calculation. Lastly, the biological implications of the differences in dose rates and dose per photon for the different irradiation methods should be carefully assessed for each small-animal irradiation experiment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement and calibration of differential Mueller matrix of distributed targets

A rigorous method for calibrating polarimetric backscatter measurements of distributed targets is presented. By characterizing the radar distortions over the entire mainlobe of the antenna, the differential Mueller matrix is derived from the measured scattering matrices with a high degree of accuracy. It is shown that the radar distortions can be determined by measuring the polarimetric response of a metallic sphere over the main lobe of the antenna. Comparison of results obtained with the new algorithm with the results derived from the old calibration method show that the discrepancy between the two methods is less than 1 dB for the backscattering coefficients. The discrepancy is more drastic for the phase-difference statistics, indicating that removal of the radar distortions from the cross products of the scattering matrix elements cannot be accomplished with the traditional calibration methods.

Sarabandi, Kamal↗

A New Method to Cross Calibrate and Validate TOMS, SBUV/2, and SCIAMACHY Measurements

A unique method to validate back scattered ultraviolet (buv) type satellite data that complements the measurements from existing ground networks is proposed. The method involves comparing the zenith sky radiance measurements from the ground to the nadir radiance measurements taken from space. Since the measurements are compared directly, the proposed method is superior to any other method that involves comparing derived products (for example, ozone), because comparison of derived products involve inversion algorithms which are susceptible to several type of errors. Forward radiative transfer (RT) calculations show that for an aerosol free atmosphere, the ground-based zenith sky radiance measurement and the satellite nadir radiance measurements can be predicted with an accuracy of better than 1 percent. The RT computations also show that for certain values of the solar zenith angles, the radiance comparisons could be better than half a percent. This accuracy is practically independent of ozone amount and aerosols in the atmosphere. Experiences with the Shuttle Solar Backscatter Ultraviolet (SSBUV) program show that the accuracy of the ground-based zenith sky radiance measuring instrument can be maintained at a level of a few tenth of a percent. This implies that the zenith sky radiance measurements can be used to validate Total Ozone Mapping Spectrometer (TOMS), Solar Backscatter Ultraviolet (SBUV/2), and The SCanning Imaging Absorption SpectroMeter for Atmospheric CHartographY (SCIAMACHY) radiance data. Also, this method will help improve the long term precision of the measurements for better trend detection and the accuracy of other BUV products such as tropospheric ozone and aerosols. Finally, in the long term, this method is a good candidate to inter-calibrate and validate long term observations of upcoming operational instruments such as Global Ozone Monitoring Experiment (GOME-2), Ozone Mapping Instrument (OMI), Ozone Dynamics Ultraviolet Spectrometer (ODUS), and Ozone Mapping and Profiler Suite (OMPS).

Ahmad, Ziauddin↗

Applicability of micro-channel plate followed by phosphor screen to charged particles

This paper experimentally investigates the applicability of a micro-channel plate (MCP) followed by a phosphor screen to charged particles along with a calibration method for estimating the acceptable limit of input particle flux and appropriate operation parameters of a particular MCP. For the first time, plasmas consisting of only lithium ions are injected into the MCP. Despite large ion numbers (N{sub i}) on the order of ≃10{sup 7}, no deterioration in the effective gain (αG) of the MCP owing to an excess amount of the extracted charge occurs in a certain range of the amplifier voltage (ΔU{sub M}) applied to the MCP. The measured αG nearly agrees with the expected value. However, once ΔU{sub M} exceeds a limit value, αG eventually begins to saturate. This is also verified in experiments using pure electron plasmas. An appropriate range of ΔU{sub M} is presented to avoid saturation and, finally, derive N{sub i} directly from the secondary electron current outputted from the MCP only after the indispensable calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ detection of tropospheric OH, HO2, NO2, and NO by laser-induced fluorescence in detection chambers at reduced pressures

For detection of OH and HO2, we have met or exceeded most of the goals of the proposal for this grant. We have succeeded in building a prototype instrument for the detection of OH and HO2 that has a detection sensitivity of about 2 x 10 exp 4 (OH molecules/cc)/(ct/s), about five times greater than proposed. The current minimum detectable OH of 1.4 x 10 exp 5 OH molecules/cc (S/N=2; 30 second integration) is less than half that proposed, and will be much lower once scattered light levels are reduced. The instrument displays other important properties. First, interfering signals from other gases and OH losses on the inlet appear to be small under laboratory and field conditions. Second, three different calibration methods, two external to the inlet, give similar results, to within 30 percent. Third, the chemical conversion efficiency of HO2 to OH by addition of reagent NO is better than 90 percent. All of these factors give us great confidence that this technique works. The instrument has gone through several variations that have not affected its potential performance but have affected its use. We were able to undergo the first field trials away from State College in June 1992, when we were able to participate informally in the ROSE experiment in rural Alabama, a year ahead of the proposed schedule for field studies. Because this field experiment was our first and the data analysis was complicated by instrument instabilities, we have not yet released the observations. None-the-less, we have gained insight into instrument design. We have not yet completed all of the proposed work. The calibration systems need to be improved to reduce the 50 percent to 100 percent uncertainties to less than 30 percent. Interference signals from ambient gases and possible losses on the inlet under field conditions need to be quantified. Finally, the detection of NO2 and NO with laser induced fluorescence is only now being seriously pursued.

Brune, William H.↗