Search NASA⌕ Search

SEARCH · Search NASA

Results for “Comparative visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Monte Carlo simulation of PET and SPECT imaging of {sup 90}Y

Purpose: Yittrium-90 ({sup 90}Y) is traditionally thought of as a pure beta emitter, and is used in targeted radionuclide therapy, with imaging performed using bremsstrahlung single-photon emission computed tomography (SPECT). However, because {sup 90}Y also emits positrons through internal pair production with a very small branching ratio, positron emission tomography (PET) imaging is also available. Because of the insufficient image quality of {sup 90}Y bremsstrahlung SPECT, PET imaging has been suggested as an alternative. In this paper, the authors present the Monte Carlo-based simulation–reconstruction framework for {sup 90}Y to comprehensively analyze the PET and SPECT imaging techniques and to quantitatively consider the disadvantages associated with them. Methods: Our PET and SPECT simulation modules were developed using Monte Carlo simulation of Electrons and Photons (MCEP), developed by Dr. S. Uehara. PET code (MCEP-PET) generates a sinogram, and reconstructs the tomography image using a time-of-flight ordered subset expectation maximization (TOF-OSEM) algorithm with attenuation compensation. To evaluate MCEP-PET, simulated results of {sup 18}F PET imaging were compared with the experimental results. The results confirmed that MCEP-PET can simulate the experimental results very well. The SPECT code (MCEP-SPECT) models the collimator and NaI detector system, and generates the projection images and projection data. To save the computational time, the authors adopt the prerecorded {sup 90}Y bremsstrahlung photon data calculated by MCEP. The projection data are also reconstructed using the OSEM algorithm. The authors simulated PET and SPECT images of a water phantom containing six hot spheres filled with different concentrations of {sup 90}Y without background activity. The amount of activity was 163 MBq, with an acquisition time of 40 min. Results: The simulated {sup 90}Y-PET image accurately simulated the experimental results. PET image is visually superior to SPECT image because of the low background noise. The simulation reveals that the detected photon number in SPECT is comparable to that of PET, but the large fraction (approximately 75%) of scattered and penetration photons contaminates SPECT image. The lower limit of {sup 90}Y detection in SPECT image was approximately 200 kBq/ml, while that in PET image was approximately 100 kBq/ml. Conclusions: By comparing the background noise level and the image concentration profile of both the techniques, PET image quality was determined to be superior to that of bremsstrahlung SPECT. The developed simulation codes will be very useful in the future investigations of PET and bremsstrahlung SPECT imaging of {sup 90}Y.

07 ISOTOPE AND RADIATION SOURCES↗

Fused filament fabrication of novel phase-change material functional composites

Additively manufactured polymer heat exchangers are of recent interest in the thermal sciences due to their lightweight and intricate heat-transfer-enhancing geometrical features. The goal of the present research is to directly encapsulate phase-change material (PCM) into polymer filament for the purpose of 3D printing polymer heat exchangers capable of latent heat thermal energy storage and management. PCMs have the ability to absorb large amounts of latent heat while undergoing a solid-to-liquid phase change at a nearly constant temperature. Encapsulation or containment of PCMs is necessary to prevent leaking since the material continuously cycles between a liquid and a solid state. An organic-based PCM and high-density polyethylene (HDPE) were combined and extruded into a functional composite filament. For the first time, with the aid of a heated enclosure and HDPE build plates, it was demonstrated that these functional composite materials can be printed using fused filament fabrication (FFF). Printing HDPE is known to be difficult; however, based on what was observed in the current study, the PCM and HDPE composite was easier to print than pure HDPE. Thermal properties, such as latent heat of fusion, phase-change temperature, and thermal conductivity, of the composite filament and 3D printed samples were investigated and compared with compression-molded bulk material. Finally, the microstructures of the composite filament and 3D printed samples were visualized, and the basic structures of the HDPE and PCM within both the filament and 3D printed parts were clearly delineated.

36 MATERIALS SCIENCE↗

Theoretical calculations of rotationally inelastic collisions of He with NaK(A {sup 1}Σ{sup +}): Transfer of population, orientation, and alignment

We have performed extensive calculations to investigate thermal energy, rotationally inelastic collisions of NaK (A{sup 1}Σ{sup +}) with He. We determined a potential energy surface using a multi-reference configuration interaction wave function as implemented by the GAMESS electronic structure code, and we have performed coupled channel scattering calculations using the Arthurs and Dalgarno formalism. We also calculate the Grawert coefficients B{sub λ}(j, j′) for each j → j′ transition. These coefficients are used to determine the probability that orientation and alignment are preserved in collisions taking place in a cell environment. The calculations include all rotational levels with j or j′ between 0 and 50, and total (translational and rotational) energies in the range 0.0002–0.0025 a.u. (∼44–550 cm{sup −1}). The calculated cross sections for transitions with even values of Δj tend to be larger than those for transitions with odd Δj, in agreement with the recent experiments of Wolfe et al. (J. Chem. Phys. 134, 174301 (2011)). The calculations of the energy dependence of the cross sections and the calculations of the fraction of orientation and alignment preserved in collisions also exhibit distinctly different behaviors for odd and even values of Δj. The calculations also indicate that the average fraction of orientation or alignment preserved in a transition becomes larger as j increases. We interpret this behavior using the semiclassical model of Derouard, which also leads to a simple way of visualizing the distribution of the angles between the initial and final angular momentum vectors j and j′. Finally, we compare the exact quantum results for j → j′ transitions with results based on the simpler, energy sudden approximation. That approximation is shown to be quite accurate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Metrics for comparison of crystallographic maps

Numerical comparison of crystallographic contour maps is used extensively in structure solution and model refinement, analysis and validation. However, traditional metrics such as the map correlation coefficient (map CC, real-space CC or RSCC) sometimes contradict the results of visual assessment of the corresponding maps. This article explains such apparent contradictions and suggests new metrics and tools to compare crystallographic contour maps. The key to the new methods is rank scaling of the Fourier syntheses. The new metrics are complementary to the usual map CC and can be more helpful in map comparison, in particular when only some of their aspects, such as regions of high density, are of interest.

36 MATERIALS SCIENCE↗

SU-G-BRB-09: Kompeito-Shot: Development of a Novel Verification System for 3D Beam Alignment Including the Sag of Gantry Head

Purpose: High accuracy of beam axis is required for high-precision radiation therapy. It is impossible to quantitatively and directly evaluate the sagging effect of the gantry head using current methods (star-shot and Winston-Lutz tests) when the gantry head sags under the weight of MLC and X-Y jaws. We introduce a novel method “Kompeito-shot (3D star-shot)” for the verification of 3D beam alignment (3D isocentricity). This method enables direct measurement of the sagging effect. We developed the system and examined the concept of this system. Methods: The system composed of a plastic scintillator (PS), a truncated cone-shaped mirror, a plane mirror and a CCD camera. Two types of PS were compared. One consisted of a column PS (Co system), the other consisted of a column PS inserted into a barrel PS with shading film in between (Co-Ba system). The system was irradiated with a 6-MV photon beam and the scintillation light was measured using the CCD camera through the mirror system. The gantry angle was set from 270 to 300 degrees to mimic the sagging of the gantry head for evaluating the accuracy of the system. The distance between a center of PS and entrance / exit points were calculated to analyze the gantry angle. And, the calculated gantry angle and the irradiated gantry angle were compared. Results: We compared the measured image of Co system and that of Co-Ba system. Entrance and exit areas were visualized clearly. The histogram showing the difference between the calculated gantry angle and the irradiated gantry angle was fitted with a Gaussian function. Mean and standard deviation of Co-Ba system were smaller than that of Co system by one order of magnitude. Conclusion: We developed the Kompeito-shot system and evaluated the accuracy of the system. The basic concept works for the verification of 3D isocentricity.

60 APPLIED LIFE SCIENCES↗

Ravel

Ravel is a tool for analyzing and visualizing parallel execution traces. It deduces a logical structure of parallel program events from the trace records and calculates comparative metrics. It displays the results of this analysis using multiple views at varying levels of detail to allow interactive exploration of the trace.

Source record↗

Laboratory Evaluation of a Natural Gas–Based Foamed Fracturing Fluid

Abstract Foams have been used as hydraulic fracturing fluids to reduce water usage and minimize the potentially deleterious impact on water-sensitive formations. Traditionally, carbon dioxide (CO2) and nitrogen (N2) have been used as the internal phase in these foamed fluids. Hydraulic fracturing with natural gas (NG) is a relatively inexpensive option, particularly if NG produced from the wellhead can be used without significant processing. In an ongoing program sponsored by the US Department of Energy (DOE), an alternative fracturing process is being developed that uses NG-based foam. Previously, the optimal thermodynamic pathway was identified to transform wellhead NG into pressurized NG suitable for use as the internal phase in a foamed fracturing fluid. Recent work has focused on preparing a NG-based foam at surface conditions typically encountered in hydraulic fracturing and measuring the stability and rheological properties of the foam. In addition, the transient response of the foam during fracture initiation was simulated using a fast-acting solenoid valve. A single base-fluid mixture was prepared by combining a commercially available viscosifier and foaming surfactant with water. The base fluid was then injected into a tee using a water pump. Simultaneously, liquefied natural gas (LNG) was pressurized using a cryogenic pump, vaporized using a heat exchanger, and injected into the tee to mix with the base fluid and generate foam. The foam then flowed through approximately 300 ft of 0.312-in. inside diameter (ID) tubing equipped with pressure transducers at several locations. The test fixture included a sight glass to visually inspect the quality of the foam. This paper reports on findings related to foam stability and rheology and compares these results to previous studies on foamed fracturing fluids.

Beck, Griffin↗

Tractometry of the Human Connectome Project: resources and insights

The Human Connectome Project (HCP) has become a keystone dataset in human neuroscience, with a plethora of important applications in advancing brain imaging methods and an understanding of the human brain. We focused on tractometry of HCP diffusion-weighted MRI (dMRI) data. We used an open-source software library (pyAFQ; https://yeatmanlab.github.io/pyAFQ) to perform probabilistic tractography and delineate the major white matter pathways in the HCP subjects that have a complete dMRI acquisition (n = 1,041). We used diffusion kurtosis imaging (DKI) to model white matter microstructure in each voxel of the white matter, and extracted tract profiles of DKI-derived tissue properties along the length of the tracts. We explored the empirical properties of the data: first, we assessed the heritability of DKI tissue properties using the known genetic linkage of the large number of twin pairs sampled in HCP. Second, we tested the ability of tractometry to serve as the basis for predictive models of individual characteristics (e.g., age, crystallized/fluid intelligence, reading ability, etc.), compared to local connectome features. To facilitate the exploration of the dataset we created a new web-based visualization tool and use this tool to visualize the data in the HCP tractometry dataset. Finally, we used the HCP dataset as a test-bed for a new technological innovation: the TRX file-format for representation of dMRI-based streamlines. We released the processing outputs and tract profiles as a publicly available data resource through the AWS Open Data program's Open Neurodata repository. We found heritability as high as 0.9 for DKI-based metrics in some brain pathways. We also found that tractometry extracts as much useful information about individual differences as the local connectome method. We released a new web-based visualization tool for tractometry—“Tractoscope” (https://nrdg.github.io/tractoscope). We found that the TRX files require considerably less disk space-a crucial attribute for large datasets like HCP. In addition, TRX incorporates a specification for grouping streamlines, further simplifying tractometry analysis.

59 BASIC BIOLOGICAL SCIENCES↗

The Time Domain Spectroscopic Survey: Changing-look Quasar Candidates from Multi-epoch Spectroscopy in SDSS-IV

Active galactic nuclei (AGN) can vary significantly in their rest-frame optical/UV continuum emission, and with strong associated changes in broad line emission, on much shorter timescales than predicted by standard models of accretion disks around supermassive black holes. Most such changing-look or changing-state AGN—and at higher luminosities, changing-look quasars (CLQs)—have been found via spectroscopic follow-up of known quasars showing strong photometric variability. The Time Domain Spectroscopic Survey of the Sloan Digital Sky Survey IV (SDSS-IV) includes repeat spectroscopy of large numbers of previously known quasars, many selected irrespective of photometric variability, and with spectral epochs separated by months to decades. Our visual examination of these repeat spectra for strong broad line variability yielded 61 newly discovered CLQ candidates. We quantitatively compare spectral epochs to measure changes in continuum and Hβ broad line emission, finding 19 CLQs, of which 15 are newly recognized. The parent sample includes only broad line quasars, so our study tends to find objects that have dimmed, i.e., turn-off CLQs. However, we nevertheless find four turn-on CLQs that meet our criteria, albeit with broad lines in both dim and bright states. We study the response of Hβ and Mg ii emission lines to continuum changes. The Eddington ratios of CLQs are low, and/or their Hβ broad line width is large relative to the overall quasar population. Repeat quasar spectroscopy in the upcoming SDSS-V black hole Mapper program will reveal significant numbers of CLQs, enhancing our understanding of the frequency and duty cycle of such strong variability, and the physics and dynamics of the phenomenon.

79 ASTRONOMY AND ASTROPHYSICS↗

Opportunities to more fully utilize safeguards information reported to the IAEA at Gas Centrifuge Enrichment Plants

In an effort to increase transparency and to strengthen IAEA safeguards, more countries are adopting practices that provide the IAEA with more timely, safeguards-relevant information to confirm nuclear operations are as declared. At Gas Centrifuge Enrichment Plants (GCEPs) potential examples include installing unattended IAEA instruments that transmit selected information back to Vienna, instruments that collect and store measurement information on-site, and daily facility operator submissions of material receipts, shipments, or utilization of key operational systems (e.g., UF6 feed stations) to on-site mail boxes. Recently the IAEA has implemented the use of on-site mailbox systems supplemented with short notice or unannounced inspections to maintain effectiveness without significantly increasing the number of inspection days. While these measures significantly improves the IAEA’s effectiveness, we have identified several opportunities for how the use of this information could be improved and how some additional information would further improve safeguards. This paper presents concepts for how the safeguards information currently collected at GCEPs could be more effectively utilized through enhancing the way that raw data is displayed visually so that it is more intuitive to the inspector and provides for more effective inspection planning and execution, comparing information with previous IAEA inspection activities (lists of previous verified inventory), through comparing data with operator supplied data when inspectors arrive (notional inventory change reports), and through evaluating the data over time to provide even greater confidence in the data and operations as declared in between inspections. This paper will also discuss several potential improvements to the submissions themselves, such as including occupancy information about product and tails stations and including weight information for each station.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Ravel

Ravel is a tool for analyzing and visualizing parallel execution traces. It deduces a logical structure of parallel program events from the trace records and calculates comparative metrics. It displays the results of this analysis using multiple views at varying levels of detail to allow interactive exploration of the trace.

Source record↗

SU-G-206-08: How Should Focal Spot Be Chosen for Optimized CT Imaging with Dose Modulation?

Purpose: To choose the preferred focal spot for achieving optimized CT image quality with balanced tube heating considerations. Methods: An anthropomorphic pelvic phantom was scanned using a GE Discovery CT750 HD at 120 and 140kVp, 0.8s rotation time, and pitch of 0.984. “Smart mA” was enabled to simulate a routine abdomen–pelvis CT scan. Permissible mA values at 120 and 140 kVp were obtained from the Serial Load Rating table (for mimicking a busy CT clinical operation) in the scanner Technical Reference Manual. At each kVp station and two Noise Index levels, the mA Upper Limit was set above/below the permissible mA values. Scanned mA values and focal spot (FS) used were obtained from the DICOM header of each image, and the FS-mA relationship was analyzed. For visual confirmation beyond recorded FS information, a CatPhan with a fat-ring attached for mimicking patient size/shape was scanned at 120kVp. A group of radiologists/physicists compared a pair of CatPhan images qualitatively. Lastly, a number of patient cases were evaluated to confirm the FS-mA relationship. Results: When preset Upper Limit values were above the permissible mA values, the Large FS (labeled 1.2) was used in scans, even if the maximum scanned mA values were much lower than the permissible values at both 120 and 140 kVp. Otherwise the Small FS (labeled 0.7) was used. Visual evaluation of the high contrast module of CatPhan and additional analysis of patient cases further confirmed that the preset Upper Limit determines which focal spot is to be used, not the actual maximum mA value to be scanned. Conclusion: Specific FS can be selected by setting up appropriate mA Upper Limit in a protocol. CT protocols could be optimized by selecting appropriate FS for improving patient image quality, especially benefiting the small size and pediatric patients.

60 APPLIED LIFE SCIENCES↗

Interactive Visualizations for Communicating Compliance and Sustainability Statements in Annual Site Environmental Reports - 20419

The annual reports of organizations are a recurring type of public disclosure that communicates what an organization has done and/or plans to do. Worldwide, organizations use annual reports as powerful instruments for communication that is rich in narrative content and visuals. From the perspective of the leadership of an organization, statutory annual reports are communication devices to stakeholders. By analogy, from the perspective of stakeholders, the annual reports are learning devices that presents stakeholders with contents to generate knowledge about an organization. We have chosen the online accessible U.S. Department of Energy (DOE) Annual Site Environmental Reports (ASERs) as a collection of resources for communicating and learning the environmental management strategies on environmental compliance and environmental sustainability. Environmental Compliance 'consists of regulatory compliance and monitoring programs that implement federal, state, and local requirements, agreements, and permits.' Environmental Sustainability 'promotes and integrates initiatives such as energy and natural resource conservation, waste minimization, green remediation, and the use of sustainable products and services.' Interactive visualizations of textual data designed with visual analytics software can allow stakeholders to interact with statements on the environmental management strategies by performing diverse actions that promote learning. These actions include annotating, comparing, filtering, navigating, selecting and sharing relevant statements. We expect that the possibility of these multiple actions in an interactive manner help stakeholders to learn more effectively about the environmental strategies at U.S. DOE sites. The current case study for the project is a collection of 1,894 annotated (value-added) statements (sentence text) from the eight chapters of the 2017 Savanah River Site (SRS) annual site environmental report. The preliminary interactive visualizations are available online. (authors)

54 ENVIRONMENTAL SCIENCES↗

Long-Term Outcomes and Complications in Patients With Craniopharyngioma: The British Columbia Cancer Agency Experience

Purpose: We report long-term outcomes and complications of craniopharyngioma patients referred to our institution. Methods and Materials: Between 1971 and 2010, 123 consecutive patients received primary treatment for craniopharyngioma in British Columbia and were referred to our institution. The median age was 30 years (range, 2-80 years). Thirty-nine percent of patients were treated primarily with subtotal resection (STR) and radiation therapy (RT), 28% with STR alone, 15% with gross total resection, 11% with cyst drainage (CD) alone, 5% with CD+RT, and 2% with RT alone. Eight percent of patients received intracystic bleomycin (ICB) therapy. Results: Median follow-up was 8.9 years, and study endpoints were reported at 10 years. Ten-year Kaplan-Meier progression-free survival (PFS) was 46%. Patients treated with STR+RT or CD+RT had the highest PFS (82% and 83%, respectively). There were no significant differences between PFS after adjuvant versus salvage RT (84% vs 74%, respectively; P=.6). Disease-specific survival (DSS) was 88%, and overall survival (OS) was 80%. Primary treatment modality did not affect DSS or OS, while older age was a negative prognostic factor for OS but not DSS. Kaplan-Meier rates for visual deterioration, anterior pituitary hormone deficiency, diabetes insipidus, seizure disorder, and cerebrovascular events (CVE) due to treatment, not tumor progression, were 27%, 76%, 45%, 16%, and 11%, respectively. The CVE rate was 29% in patients who received ICB compared to 10% in those who did not (P=.07). Conclusions: We report favorable PFS in patients with craniopharyngioma, especially in those who received RT after surgery. DSS and OS rates were excellent regardless of primary treatment modality. We observed a high incidence of hypopituitarism, visual deterioration, and seizure disorder. Eleven percent of patients experienced CVEs after treatment. There was a suggestion of increased CVE risk in patients treated with ICB.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feeder Voltage Regulation with High-Penetration PV Using Advanced Inverters and a Distribution Management System: A Duke Energy Case Study

Duke Energy, Alstom Grid, and the National Renewable Energy Laboratory teamed up to better understand the impacts of solar photovoltaics (PV) on distribution system operations. The core goal of the project is to compare the operational - specifically, voltage regulation - impacts of three classes of PV inverter operations: 1.) Active power only (Baseline); 2.) Local inverter control (e.g., PF...not equal...1, Q(V), etc.); and 3.) Integrated volt-VAR control (centralized through the distribution management system). These comparisons were made using multiple approaches, each of which represents an important research-and-development effort on its own: a) Quasi-steady-state time-series modeling for approximately 1 year of operations using the Alstom eTerra (DOTS) system as a simulation engine, augmented by Python scripting for scenario and time-series control and using external models for an advanced inverter; b) Power-hardware-in-the-loop (PHIL) testing of a 500-kVA-class advanced inverter and traditional voltage regulating equipment. This PHIL testing used cosimulation to link full-scale feeder simulation using DOTS in real time to hardware testing; c) Advanced visualization to provide improved insights into time-series results and other PV operational impacts; and d) Cost-benefit analysis to compare the financial and business-model impacts of each integration approach.

14 SOLAR ENERGY↗

SU-E-J-196: New Visualization Methods for Longitudinal MRI Registrations and Segmentations

Purpose: To develop visualization techniques to facilitate easy assessment of (a) registration and (b) tracking volumetric changes in structures during radiation therapy from MRI. Method: The frequently used method for visualizing registrations between scans is a multi-color overlay technique or deformation vector fields. However, the overlay technique is unintuitive and does not help to appreciate the quality of registration particularly when the registration mismatches are not very large. Similarly, the deformation fields give an indication of extent of deformation but do not help to assess the differences in registration. We present a mirroring and edge-augmented mirroring technique that places the fixed and moving image next to each other and allows the user to quickly assess the small differences in registration. Next, we present a volumetric intersection based 3D model to visualize the changes in diseased lymph node volumes in head and neck cancer. 3D model-based visualization provides more information about the location-specific changes in volume rather than the simplistic one dimensional information obtained from 2D plot of nodal volume changes. Result: We show results comparing our approach with the standard colorbased overlay method for comparing registrations of intra-patient registrations using T2-MRI. Upon comparing the mirroring technique with the color-overlay, one can more easily appreciate the differences in registration. Adding edge-based mirroring seems to further assist in evaluating the registration. Our approach for viewing registrations seems to be more intuitive and easy to use in order to help assess the quality of registration compared to color-based overlays. Similarly, the change volumetric model together with a 2D plot reveals more information including the locations undergoing changes and responding to treatment. Conclusions: Better approaches are necessary for assessing the quality of registrations and changes in diseased structures over time. Our approach presents some novel visualization solutions for registration and segmentation.

60 APPLIED LIFE SCIENCES↗

Experiments and CFD simulation of mass transfer and hydrodynamics in a cylindrical bubble column

Flow visualization, Particle Image Velocimetry (PIV) and dissolved oxygen charging experiments are carried out in a small-scale cylindrical air-water bubble column at different superficial gas velocities. Void fraction profile, total gas holdup, liquid phase velocity field and volumetric mass transfer coefficient are obtained. Details of each experiment are given, with a new procedure for obtaining a 2D void fraction profile from flow visualization by image processing and time averaging which could provide useful information for CFD model validation. The experimental results are analyzed and compared with simulations where good agreement is found for both local and global flow patterns. The averaged governing equations and constitutive relations used in the simulation are discussed briefly, with emphasis on the proper comparison between simulations and experiments based on the derivation of the two-fluid model. Finally, by conducting three sets of experiments related to phase distribution, velocity field and mass transfer in the same apparatus, a validated CFD model for multiphase mass transfer is established and can be used in the future design of a multi-phase reactor.

42 ENGINEERING↗

Collimator design for a multipinhole brain SPECT insert for MRI

Purpose: Brain single photon emission computed tomography (SPECT) imaging is an important clinical tool, with unique tracers for studying neurological diseases. Nowadays, most commercial SPECT systems are combined with x-ray computed tomography (CT) in so-called SPECT/CT systems to obtain an anatomical background for the functional information. However, while CT images have a high spatial resolution, they have a low soft-tissue contrast, which is an important disadvantage for brain imaging. Magnetic resonance imaging (MRI), on the other hand, has a very high soft-tissue contrast and does not involve extra ionizing radiation. Therefore, the authors designed a brain SPECT insert that can operate inside a clinical MRI. Methods: The authors designed and simulated a compact stationary multipinhole SPECT insert based on digital silicon photomultiplier detector modules, which have shown to be MR-compatible and have an excellent intrinsic resolution (0.5 mm) when combined with a monolithic 2 mm thick LYSO crystal. First, the authors optimized the different parameters of the SPECT system to maximize sensitivity for a given target resolution of 7.2 mm in the center of the field-of-view, given the spatial constraints of the MR system. Second, the authors performed noiseless simulations of two multipinhole configurations to evaluate sampling and reconstructed resolution. Finally, the authors performed Monte Carlo simulations and compared the SPECT insert with a clinical system with ultrahigh-resolution (UHR) fan beam collimators, based on contrast-to-noise ratio and a visual comparison of a Hoffman phantom with a 9 mm cold lesion. Results: The optimization resulted in a stationary multipinhole system with a collimator radius of 150.2 mm and a detector radius of 172.67 mm, which corresponds to four rings of 34 diSPM detector modules. This allows the authors to include eight rings of 24 pinholes, which results in a system volume sensitivity of 395 cps/MBq. Noiseless simulations show sufficient axial sampling (in a Defrise phantom) and a reconstructed resolution of 5.0 mm (in a cold-rod phantom). The authors compared the 24-pinhole setup with a 34-pinhole system (with the same detector radius but a collimator radius of 156.63 mm) and found that 34 pinholes result in better uniformity but a worse reconstruction of the cold-rod phantom. The authors also compared the 24-pinhole system with a clinical triple-head UHR fan beam system based on contrast-to-noise ratio and found that the 24-pinhole setup performs better for the 6 mm hot and the 16 mm cold lesions and worse for the 8 and 10 mm hot lesions. Finally, the authors reconstructed noisy projection data of a Hoffman phantom with a 9 mm cold lesion and found that the lesion was slightly better visible on the multipinhole image compared to the fan beam image. Conclusions: The authors have optimized a stationary multipinhole SPECT insert for MRI and showed the feasibility of doing brain SPECT imaging inside a MRI with an image quality similar to the best clinical SPECT systems available.

60 APPLIED LIFE SCIENCES↗