Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computational Human Performance Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Reliability Assessment of Safety-Critical Network Communication in a Digitalized Nuclear Power Plant

In analog instrumentation and control (I and C) systems for nuclear power plants (NPPs), most connections are comprised of hardwired point-to-point types. Since they are based on analog technologies, they are fragile to noise and require analog-to-digital conversion time. Therefore, many NPPs have adopted communication network for the exchange of safety-critical data between programmable logic controllers (PLCs) in digital I and C systems to effectively accommodate a huge number of field controllers. However, the primary issue of digital network communication in a safety-critical system involves potential hazards, such as partial or total loss of communication between PLCs, which may result in a failure of safety critical signal generation when it is needed. Therefore, the probability that a safety-critical system in digitalized NPP becomes unsafe due to a network failure must be evaluated to quantify the risk of digital I and C system. In Korea, the Engineered Safety Feature-Component Control System (ESF-CCS) was developed as one of the digital safety-critical system in Advanced Power Reactor- 1400 (APR-1400). The function of a digital engineered safety feature (ESF) actuation system and field actuator controllers of conventional NPPs are performed by the ESF-CCS. In this system, safety-critical network, High Reliable- Safety Data Network (HR-SDN), was employed for the safety-critical data transmission from group controllers (GCs) to loop controllers (LCs). In this study, a framework for assessing the reliability of a HR-SDN network communication between GCs and LCs in the ESF-CCS in addition to a fault-tree model for ESF components considering network failure between GCs and LCs were developed to assess the plant risk effect of a newly developed digitalized ESF-CCS. Based on the case studies and cut set analysis, the risk effect of network failure on plant risk and the important risk contributors of network failure were quantitatively addressed. A framework for identifying the potential hazardous states of network communication in the ESFCCS was proposed. In addition, a fault-tree model for network communication failure was developed to estimate the risk effects of network failure between the GCs and LCs on ESF-CCS signal failure. The developed fault-tree model was then applied to several case studies. The fault-tree model of ESF-CCS signal failure for ESF components required for various mitigation actions regarding NPP DBAs was designed by considering the identified hazardous states of network failure that would result in a failure to provide input signals to the corresponding LC. As a sensitivity study, three case studies were performed based on the periodic test methods for hardware components in HR-SDN module and their test intervals in this study. The quantitative results for three case studies demonstrated that the probability of overall network communication failure, which was calculated as the sum of the failure probability associated with each failure cause, contributed up to 1.58% on the Small-LOCA CD frequency. The results also revealed the important basic events related to network failure in the case studies which included CCF of hardware and software in HR-SDN module. This study is expected to provide insight into the development of the fault-tree model for the network failure in digital I and C system and into the quantification of the risk effect of network failure for safety-critical data transmission in NPPs. As a further study, the risk effects of network failure in the ESF-CCS on the plant risk can be estimated in a more detailed manner by analyzing the failure modes and causes in a sub-component level and the fault detection coverage of the fault tolerance techniques for network failure implemented in ESF-CCS after the detailed configuration of ESF-CCS is decided. In terms of the failure of manual ESF actuation, the relationship among the human action failures must be investigated to consider multiple human error condition since ESF-CCS provides multiple manual actuation to assure the diversity of the system. Since the conventional HEP method cannot accommodate the multiple conditions in a fault tree, condition-based human reliability assessment (CBHRA) method or the dynamic human reliability modeling approach can be applied to include a complex relationship among the automated safety signal generation and the human operator's manual actuation, avoiding the optimistic estimation of HEP of the human action failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design and Development of a Robotic Exoskeleton Device for use in Glove Boxes - 20374

Glovebox operators in nuclear facilities often operate under radioactive environment and typically perform monotonous, dull and repetitive work. This can result in muscle fatigue leading to increased levels of accidents. Current research work aims in assisting the glovebox operators by designing a novel upper limb exoskeleton device to reduce injuries and increase worker efficiency. Almost none of the commercially available hand and upper body exoskeletons are directly suitable for use in gloveboxes. This explains the novelty of the present work in developing a wearable powered robotic exoskeleton device. The device consists of electronics, motors and spring systems mounted on adjustable plates and is supported by a stationary frame behind the worker. The device is intended to be portable and adjustable according to the operator height. The elbow has a flexion movement assisted with motor control by way of a Bowden cable system. The system is floated on a spring and pulley combination that allows for extra safety and smoothness of operation. The end points are fixed near the pivot points to help minimize unwanted movement/torque. The extension movement of the upper and lower arm are assisted by gravity and a counter spring. The shoulder and upper arm movement are held in a neutral position with a spring system for counter balance allowing small movements within the glovebox. This initial concept considers only the vertical movement of the arm. The abduction and adduction movement will not be assisted or impeded by the over shoulder plate or at the forearm plate allowing for full range of motion. Several glovebox aspects such as the level of task assistance, ergonomic design, minimum hindrance in dexterity/operator movements and tear resistance for hazardous safety reasons will be considered in the design of the exoskeleton. Computer models will be simulated to test the load levels and stress conditions on the exoskeleton to enhance the designs. The exoskeleton focusses on major muscular involvement reduction through weight offset and active assistance with minimal parts and hence the device is derived with several joint links and contains both passive and active joints. The paper details the various stages in the design development and prototype testing of the exoskeleton device. Upon successful prototype device development, human testing will be conducted in a replica of the SRS-235F hot cell facility constructed at FIU-ARC. The final stage of the project will be potential testing/deployment of the exoskeleton device in one of the glovebox facilities in Savannah River Nuclear Waste site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Free Energy and Flexibility Analysis of Autoinhibited Human BRAF

The RAF serine/threonine protein kinases function as direct effectors of RAS in the intracellular transmission of extracellular growth signals, and they are key targets for drug discovery, given the high incidence of oncogenic mutations in RAF and other components of this signaling pathway. In its inactive state, RAF is held in an autoinhibited conformation in the cytosol through a combination of intramolecular interactions and binding to a regulatory 14−3−3 protein dimer. Activation of RAF is initiated by its interaction with membrane-localized GTP-bound RAS, which induces conformational changes that release RAF from its autoinhibited state. However, the molecular mechanisms governing RAF activation remain incomplete, largely due to the challenges in experimentally capturing the intermediate conformational states in this process. To address this gap, we developed a comprehensive all-atom model of BRAF based on existing cryo-EM structures. Using this model, we performed extensive molecular dynamics simulations to evaluate the stability and free energy landscape of autoinhibited BRAF in solution. Our analysis reveals conformational flexibility within the autoinhibited complex, suggesting that this dynamic behavior may play a role in facilitating BRAF activation upon engagement with the membrane-bound RAS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Contour interpolated radial basis functions with spline boundary correction for fast 3D reconstruction of the human articular cartilage from MR images

Purpose: The aim of this work is to demonstrate a new image processing technique that can provide a “near real-time” 3D reconstruction of the articular cartilage of the human knee from MR images which is user friendly. This would serve as a point-of-care 3D visualization tool which would benefit a consultant radiologist in the visualization of the human articular cartilage. Methods: The authors introduce a novel fusion of an adaptation of the contour method known as “contour interpolation (CI)” with radial basis functions (RBFs) which they describe as “CI-RBFs.” The authors also present a spline boundary correction which further enhances volume estimation of the method. A subject cohort consisting of 17 right nonpathological knees (ten female and seven male) is assessed to validate the quality of the proposed method. The authors demonstrate how the CI-RBF method dramatically reduces the number of data points required for fitting an implicit surface to the entire cartilage, thus, significantly improving the speed of reconstruction over the comparable RBF reconstruction method of Carr. The authors compare the CI-RBF method volume estimation to a typical commercial package (3D DOCTOR), Carr’s RBF method, and a benchmark manual method for the reconstruction of the femoral, tibial, and patellar cartilages. Results: The authors demonstrate how the CI-RBF method significantly reduces the number of data points (p-value < 0.0001) required for fitting an implicit surface to the cartilage, by 48%, 31%, and 44% for the patellar, tibial, and femoral cartilages, respectively. Thus, significantly improving the speed of reconstruction (p-value < 0.0001) by 39%, 40%, and 44% for the patellar, tibial, and femoral cartilages over the comparable RBF model of Carr providing a near real-time reconstruction of 6.49, 8.88, and 9.43 min for the patellar, tibial, and femoral cartilages, respectively. In addition, it is demonstrated how the CI-RBF method matches the volume estimation of a typical commercial package (3D DOCTOR), Carr’s RBF method, and a benchmark manual method for the reconstruction of the femoral, tibial, and patellar cartilages. Furthermore, the performance of the segmentation method used for the extraction of the femoral, tibial, and patellar cartilages is assessed with a Dice similarity coefficient, sensitivity, and specificity measure providing high agreement to manual segmentation. Conclusions: The CI-RBF method provides a fast, accurate, and robust 3D model reconstruction that matches Carr’s RBF method, 3D DOCTOR, and a manual benchmark method in accuracy and significantly improves upon Carr’s RBF method in data requirement and computational speed. In addition, the visualization tool has been designed to quickly segment MR images requiring only four mouse clicks per MR image slice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of an Erythema-Weighted UV Model Using Broadband Solar Irradiance Measurements From Eleven U.S. Sites: Preprint

Erythema-weighted UV solar irradiance (UV-E) has a potential impact on human health if the recommended maximum exposure times are exceeded. In spite of this, it is not measured at most sites that measure Global Horizontal Irradiance (GHI). However, since UV-E is highly correlated with GHI and total ozone content it can be estimated from this information with sufficient accuracy to assisst in public health recommendations. The Power Model (PM) provides a simple method to estimate the erythema-weighted UV irradiance (UV-E) from measured GHI, total ozone column and air mass. In this work, the performance of the PM method is assessed using high-quality data from 11 sites in the continental U.S. (part of SURFRAD and SOLRAD networks) and total ozone estimates publicly available from the MERRA-2 re-analysis database. A three year period (2021- 2023) at 1-minute frequency is considered. The results (for time aggregations of 5 and 60 minutes) show a high Pearson's correlations (> 0.99), consistently positive mean bias deviations (below 13%) and dispersions in the 8-19% range at all sites. Relative values are expressed in terms of the corresponding measurement mean. The performance indicators remain consistent across time resolutions (5 or 60 minutes), suggesting that the model's performance is robust and not significantly affected by short-term variability (which is captured by GHI). Spatial patterns reveal higher biases and RMSD in northern and eastern locations. These values represent a significant improvement over widely used satellite-based global UV-E estimates and open the possibility of using the PM with satellite-based GHI estimates for operational UV-E mapping over the contiguous U.S. territory.

14 SOLAR ENERGY↗

Performing Numerical Analysis of Cybersecurity Options Using Dynamic Risk Analysis Tool EMRALD

Cyberattacks can have many different attack paths, durations, and goals. There are also many different mitigation options involving hardware, software, and/or humans. Considering a cyber threat should involve defense-in-depth methods and a quantitative or numerical evaluation of overall effectiveness against dynamic, time-dependent attacks to make cost and risk-informed decisions. Typical cyberattack modeling methods only provide a qualitative evaluation. The main areas of cybersecurity are confidentiality, integrity, and availability. For companies with cyber-physical systems such as advanced nuclear reactors, cyber-related safety is a requirement set by North American Electric Reliability and the U.S. Nuclear Regulatory Commission. They are also concerned about availability or reliability as a business case. As cyber threats are evolving to a business-for-hire structure, more attacks may focus on disrupting business success and reliability, causing financial and economic stability risk. Companies want to know business reliability and recovery from those threats, and that requires modeling physical behavior of the targets. Dynamic-state-based and Markov-based modeling provides a method for better cyber scenario modeling with different tools having issues such as state-base explosion. Dynamic modeling enables time and conditional features not found in other numerical evaluation methods. EMRALD (Event Modeling Risk Assessment using Lined Diagrams) is a dynamic risk analysis modeling and simulation tool and has features that reduce modeling issues. It has been used to model different time-dependent events including plant behavior and operator procedures. As a general modeling tool, EMRALD can also be used to model cyberattack scenarios with varying mitigation options and quantify effectiveness, producing numerical data for risk-informed decisions. This paper uses EMRALD to demonstrate that dynamic numerical risk analysis can be used for cyber threat modeling to provide insights for design decision-making and optimize defense strategies. Keywords: cyber modeling; cyber-physical systems; numerical cyber modeling

97 - MATHEMATICS AND COMPUTING↗

KEBLM: Knowledge-Enhanced Biomedical Language Models

Pretrained language models (PLMs) have demonstrated strong performance on many natural language processing (NLP) tasks. Despite their great success, these PLMs are typically pretrained only on unstructured free texts without leveraging existing structured knowledge bases that are readily available for many domains, especially scientific domains. As a result, these PLMs may not achieve satisfactory performance on knowledge-intensive tasks such as biomedical NLP. Comprehending a complex biomedical document without domain-specific knowledge is challenging, even for humans. Inspired by this observation, we propose a general framework for incorporating various types of domain knowledge from multiple sources into biomedical PLMs. We encode domain knowledge using lightweight adapter modules, bottleneck feed-forward networks that are inserted into different locations of a backbone PLM. For each knowledge source of interest, we pretrain an adapter module to capture the knowledge in a self-supervised way. We design a wide range of self-supervised objectives to accommodate diverse types of knowledge, ranging from entity relations to description sentences. Once a set of pretrained adapters is available, we employ fusion layers to combine the knowledge encoded within these adapters for downstream tasks. Each fusion layer is a parameterized mixer of the available trained adapters that can identify and activate the most useful adapters for a given input. Our method diverges from prior work by including a knowledge consolidation phase, during which we teach the fusion layers to effectively combine knowledge from both the original PLM and newly-acquired external knowledge using a large collection of unannotated texts. After the consolidation phase, the complete knowledge-enhanced model can be fine-tuned for any downstream task of interest to achieve optimal performance. Extensive experiments on many biomedical NLP datasets show that our proposed framework consistently improves the performance of the underlying PLMs on various downstream tasks such as natural language inference, question answering, and entity linking. These results demonstrate the benefits of using multiple sources of external knowledge to enhance PLMs and the effectiveness of the framework for incorporating knowledge into PLMs. Finally, while primarily focused on the biomedical domain in this work, our framework is highly adaptable and can be easily applied to other domains, such as the bioenergy sector.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

TU-FG-209-11: Validation of a Channelized Hotelling Observer to Optimize Chest Radiography Image Processing for Nodule Detection: A Human Observer Study

Purpose: To validate the use of a Channelized Hotelling Observer (CHO) model for guiding image processing parameter selection and enable improved nodule detection in digital chest radiography. Methods: In a previous study, an anthropomorphic chest phantom was imaged with and without PMMA simulated nodules using a GE Discovery XR656 digital radiography system. The impact of image processing parameters was then explored using a CHO with 10 Laguerre-Gauss channels. In this work, we validate the CHO’s trend in nodule detectability as a function of two processing parameters by conducting a signal-known-exactly, multi-reader-multi-case (MRMC) ROC observer study. Five naive readers scored confidence of nodule visualization in 384 images with 50% nodule prevalence. The image backgrounds were regions-of-interest extracted from 6 normal patient scans, and the digitally inserted simulated nodules were obtained from phantom data in previous work. Each patient image was processed with both a near-optimal and a worst-case parameter combination, as determined by the CHO for nodule detection. The same 192 ROIs were used for each image processing method, with 32 randomly selected lung ROIs per patient image. Finally, the MRMC data was analyzed using the freely available iMRMC software of Gallas et al. Results: The image processing parameters which were optimized for the CHO led to a statistically significant improvement (p=0.049) in human observer AUC from 0.78 to 0.86, relative to the image processing implementation which produced the lowest CHO performance. Conclusion: Differences in user-selectable image processing methods on a commercially available digital radiography system were shown to have a marked impact on performance of human observers in the task of lung nodule detection. Further, the effect of processing on humans was similar to the effect on CHO performance. Future work will expand this study to include a wider range of detection/classification tasks and more observers, including experienced chest radiologists.

60 APPLIED LIFE SCIENCES↗

Federated benchmarking of medical artificial intelligence with MedPerf

Medical artificial intelligence (AI) has tremendous potential to advance healthcare by supporting and contributing to the evidence-based practice of medicine, personalizing patient treatment, reducing costs, and improving both healthcare provider and patient experience. Unlocking this potential requires systematic, quantitative evaluation of the performance of medical AI models on large-scale, heterogeneous data capturing diverse patient populations. Here, to meet this need, we introduce MedPerf, an open platform for benchmarking AI models in the medical domain. MedPerf focuses on enabling federated evaluation of AI models, by securely distributing them to different facilities, such as healthcare organizations. This process of bringing the model to the data empowers each facility to assess and verify the performance of AI models in an efficient and human-supervised process, while prioritizing privacy. We describe the current challenges healthcare and AI communities face, the need for an open platform, the design philosophy of MedPerf, its current implementation status and real-world deployment, our roadmap and, importantly, the use of MedPerf with multiple international institutions within cloud-based technology and on-premises scenarios. Finally, we welcome new contributions by researchers and organizations to further strengthen MedPerf as an open benchmarking platform.

60 APPLIED LIFE SCIENCES↗

Development of models for predicting Torsade de Pointes cardiac arrhythmias using perceptron neural networks

Background: Blockage of some ion channels and in particular, the hERG (human Ether-a’-go-go-Related Gene) cardiac potassium channel delays cardiac repolarization and can induce arrhythmia. In some cases it leads to a potentially life-threatening arrhythmia known as Torsade de Pointes (TdP). Therefore recognizing drugs with TdP risk is essential. Candidate drugs that are determined not to cause cardiac ion channel blockage are more likely to pass successfully through clinical phases II and III trials (and preclinical work) and not be withdrawn even later from the marketplace due to cardiotoxic effects. The objective of the present study is to develop an SAR (Structure-Activity Relationship) model that can be used as an early screen for torsadogenic (causing TdP arrhythmias) potential in drug candidates. The method is performed using descriptors comprised of atomic NMR chemical shifts (13C and 15N NMR) and corresponding interatomic distances which are combined into a 3D abstract space matrix. The method is called 3D-SDAR (3-dimensional spectral data-activity relationship) and can be interrogated to identify molecular features responsible for the activity, which can in turn yield simplified hERG toxicophores. A dataset of 55 hERG potassium channel inhibitors collected from Kramer et al. consisting of 32 drugs with TdP risk and 23 with no TdP risk was used for training the 3D-SDAR model. Results: An artificial neural network (ANN) with multilayer perceptron was used to define collinearities among the independent 3D-SDAR features. A composite model from 200 random iterations with 25% of the molecules in each case yielded the following figures of merit: training, 99.2%; internal test sets, 66.7%; external (blind validation) test set, 68. 4%. In the external test set, 70.3% of positive TdP drugs were correctly predicted. Moreover, toxicophores were generated from TdP drugs. Conclusion: A 3D-SDAR was successfully used to build a predictive model for drug-induced torsadogenic and non-torsadogenic drugs based on 55 compounds. The model was tested in 38 external drugs.

59 BASIC BIOLOGICAL SCIENCES↗

Traffic Control via Connected and Automated Vehicles (CAVs): An Open-Road Field Experiment with 100 CAVs

The CIRCLES project aims to reduce instabilities in traffic flow, which are naturally occurring phenomena due to human driving behavior. Also called “phantom jams” or “stop-and-go waves,” these instabilities are a significant source of wasted energy. Toward this goal, the CIRCLES project designed a control system, referred to as the MegaController by the CIRCLES team, that could be deployed in real traffic. Our field experiment, the MegaVanderTest (MVT), leveraged a heterogeneous fleet of 100 longitudinally controlled vehicles as Lagrangian traffic actuators, each of which ran a controller with the architecture described in this article. The MegaController is a hierarchical control architecture that consists of two main layers. The upper layer is called the Speed Planner and is a centralized optimal control algorithm. It assigns speed targets to the vehicles, conveyed through the LTE cellular network. The lower layer is a control layer, running on each vehicle. It performs local actuation by overriding the stock adaptive cruise controller, using the stock onboard sensors. The Speed Planner ingests live data feeds provided by third parties as well as data from our own control vehicles and uses both to perform the speed assignment. The architecture of the Speed Planner allows for the modular use of standard control techniques, such as optimal control, model predictive control (MPC), kernel methods, and others. The architecture of the local controller allows for the flexible implementation of local controllers. Corresponding techniques include deep reinforcement learning (RL), MPC, and explicit controllers. Depending on the vehicle architecture, all onboard sensing data can be accessed by the local controllers or only some. Likewise, control inputs vary across different automakers, with inputs ranging from torque or acceleration requests for some cars to electronic selection of adaptive cruise control (ACC) setpoints in others. The proposed architecture technically allows for the combination of all possible settings proposed previously, that is {Speed Planner algorithms} × {local Vehicle Controller algorithms} × {full or partial sensing} × {torque or speed control}. As a result, most configurations were tested throughout the ramp up to the MegaVandertest (MVT).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

WE-AB-202-08: Feasibility of Single-Inhalation/Single-Energy Xenon CT for High-Resolution Imaging of Regional Lung Ventilation in Humans

Purpose: To demonstrate the efficacy of a novel functional lung imaging method that utilizes single-inhalation, single-energy xenon CT (Xe-CT) lung ventilation scans, and to compare it against the current clinical standard, ventilation single-photon emission CT (V-SPECT). Methods: In an IRB-approved clinical study, 14 patients undergoing thoracic radiotherapy received two successive single inhalation, single energy (80keV) CT images of the entire lung using 100% oxygen and a 70%/30% xenon-oxygen mixture. A subset of ten patients also received concurrent SPECT ventilation scans. Anatomic reproducibility between the two scans was achieved using a custom video biofeedback apparatus. The CT images were registered to each other by deformable registration, and a calculated difference image served as surrogate xenon ventilation map. Both lungs were partitioned into twelve sectors, and a sector-wise correlation was performed between the xenon and V-SPECT scans. A linear regression model was developed with forced expiratory volume (FEV) as a predictor and the coefficient of variation (CoV) as the outcome. Results: The ventilation comparison for five of the patients had either moderate to strong Pearson correlation coefficients (0.47 to 0.69, p<0.05). Of these, four also had moderate to strong Spearman correlation coefficients (0.46 to 0.80, p<0.03). The patients with the strongest correlation had clear regional ventilation deficits. The patient comparisons with the weakest correlations had more homogeneous ventilation distributions, and those patients also had diminished lung function as assessed by spirometry. Analysis of the relationship between CoV and FEV yielded a non-significant trend toward negative correlation (Pearson coefficient −0.60, p<0.15). Conclusion: Significant correlations were found between the Xe-CT and V-SPECT ventilation imagery. The results from this small cohort of patients indicate that single inhalation, single energy Xe-CT has the potential to quantify regional lung ventilation volumetrically with high resolution using widely accessible radiologic equipment. Bill Loo and Peter Maxim are founders of TibaRay, Inc. Bill Loo is also a board member. Bill Loo and Peter Maxim have received research grants from Varian Medical Systems, Inc. and RaySearch Laboratory.

60 APPLIED LIFE SCIENCES↗

Evaluation of respiratory and cardiac motion correction schemes in dual gated PET/CT cardiac imaging

Purpose: Cardiac imaging suffers from both respiratory and cardiac motion. One of the proposed solutions involves double gated acquisitions. Although such an approach may lead to both respiratory and cardiac motion compensation there are issues associated with (a) the combination of data from cardiac and respiratory motion bins, and (b) poor statistical quality images as a result of using only part of the acquired data. The main objective of this work was to evaluate different schemes of combining binned data in order to identify the best strategy to reconstruct motion free cardiac images from dual gated positron emission tomography (PET) acquisitions. Methods: A digital phantom study as well as seven human studies were used in this evaluation. PET data were acquired in list mode (LM). A real-time position management system and an electrocardiogram device were used to provide the respiratory and cardiac motion triggers registered within the LM file. Acquired data were subsequently binned considering four and six cardiac gates, or the diastole only in combination with eight respiratory amplitude gates. PET images were corrected for attenuation, but no randoms nor scatter corrections were included. Reconstructed images from each of the bins considered above were subsequently used in combination with an affine or an elastic registration algorithm to derive transformation parameters allowing the combination of all acquired data in a particular position in the cardiac and respiratory cycles. Images were assessed in terms of signal-to-noise ratio (SNR), contrast, image profile, coefficient-of-variation (COV), and relative difference of the recovered activity concentration. Results: Regardless of the considered motion compensation strategy, the nonrigid motion model performed better than the affine model, leading to higher SNR and contrast combined with a lower COV. Nevertheless, when compensating for respiration only, no statistically significant differences were observed in the performance of the two motion models considered. Superior image SNR and contrast were seen using the affine respiratory motion model in combination with the diastole cardiac bin in comparison to the use of the whole cardiac cycle. In contrast, when simultaneously correcting for cardiac beating and respiration, the elastic respiratory motion model outperformed the affine model. In this context, four cardiac bins associated with eight respiratory amplitude bins seemed to be adequate. Conclusions: Considering the compensation of respiratory motion effects only, both affine and elastic based approaches led to an accurate resizing and positioning of the myocardium. The use of the diastolic phase combined with an affine model based respiratory motion correction may therefore be a simple approach leading to significant quality improvements in cardiac PET imaging. However, the best performance was obtained with the combined correction for both cardiac and respiratory movements considering all the dual-gated bins independently through the use of an elastic model based motion compensation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Analytics Studies Applied to US Department of Veterans Affairs' Corporate Data Warehouse (Initial Draft)

In this report, we describe our experience of applying several advanced analytics algorithms to the US Department of Veterans Affairs’ (VA’s) Corporate Data Warehouse (CDW) electronic health records datasets during FY2017-18. While various algorithms were applied to the CDW data, the main goal of this effort was to provide useful insights into the operational aspects (as opposed to the purely clinical aspect) of this specific implementation. Since there are not many reports in the public literature on advanced analytics applied to this data, this report provides unique insight in this regard. We focused on two machine learning (ML) applications: (1) clinical pathway inference (patterns dominating clinical pathways applied to a male dataset of Stable Ischemic Heart Disease patients as use case) and (2) medical-concept representation learning’s capability to inform and refine cohort membership based on probable patient outcomes. During our study on clinical pathway inference, we used two main modeling techniques: (a) topic probabilistic modeling (latent Dirichlet allocation [LDA]) and (b) feature imbedding. We observed that the applicability of LDA to the pathway inference remains in question. LDA provides results that are intuitive and easy for humans to comprehend; however, when applied to the pathway inference, it also generates pathway patterns that consist of a few dominant pathway components. In addition, LDA provides no information regarding the relationships among components in the same pathway. The outputs of LDA are also found to categorize patients based on their trace data of clinical procedures. However, the results suggest that LDA is biased toward statistically dominant components. This makes it particularly hard to discriminate pathway subbranches. To address the issue, we designed a new pathway inference methodology that integrates temporal ordering of pathway components into LDA results, as existing feature embedding tools such as word2vec are not readily applicable to our task. In addition, we developed our own feature embedding tool customized for patient traces. We conclude this study by suggesting two approaches to use embedding representation of a component into LDA and briefly list our lessons learned and recommendations for future work. For our study on medical-concept representation learning ability to inform and refine cohort membership based on probable patient outcomes, during our empirical evaluation we compared methods from medical-concept learning to standard one of a kind (one-of-K) encoding to evaluate the change in effectiveness as done in Choi, Schuetz, Stewart, and Sun (2016). We performed two primary empirical evaluations. The first evaluation was on a curated collection of 60,000 patients with no more than 1 year of medical history included. The second was a collection of patients with no restriction to the amount of medical history included. The hypothesis across both evaluations is that representation learning is broadly useful independent of downstream processing models; thus, for each experiment, we trained three models—a logistic regression model, a two-layer neural network model, and a nearest-neighbor model—and then averaged the results. Each model was trained using fivefold cross validation. We provided evidence that medical-representation learning improves predictions of the primary diagnosis category of a short patient history through 12 experiments. In addition, we provided evidence that medical-representation learning fails to improve prediction of the primary diagnosis category of an arbitrarily long patient history through 12 experiments. We conclude this study with a brief list of our lessons learned and recommendations for future work. We conclude the report with a discussion of recent technology trends as they relate to our artificial intelligence and, more specifically, to our ML research and approaches as described previously.

97 MATHEMATICS AND COMPUTING↗

Analysis of the Impact of Radiation on Cameras and Robotic Perception - 19242

Robotic systems are increasingly used for inspection, maintenance, and disaster assistance for nuclear power plants. These robots utilize increasingly high levels of autonomy to operate in environments that are unsafe for humans to operate the robot in or require more precise control over the robot than a human can offer. In these cases, the robot must include perception and computation components to autonomously sense and navigate through the environment to fulfill its mission. This difficult task is complicated by radiation interfering with sensors' operation. The impact of this interference is largely unexplored, as existing works on radiation interference on sensors focus on estimating the incident radiation, rather than how it impacts a robotic system using the sensor. In this work, we seek to quantify and describe the impact of radiation on cameras, and how the radiation affects robotic performance. In this paper we study cameras that are suitable for small, lightweight unmanned aerial vehicles (UAVs) that are increasingly deployed to fly in confined areas in emergencies, where the surrounding environment is unsafe for workers to operate. These small UAVs lack the payload capacity to carry significant radiation shielding, so any onboard sensors will be affected by radiation. In the case of cameras, this radiation appears as noise in the camera imagery. This noise will interfere with the UAV's operation, by obscuring obstacles and interfering with localization and optical flow algorithms that detect detailed features in the environment. To date, there is a lack of information on how the radiation noise in the camera image impacts the overall robot system performance Existing work focuses on estimating the amount of incident radiation by measuring the corruption in the images. However, these works suffer several shortcomings for robotic systems. First, a robot must be able to successfully navigate its environment during a successful mission, and merely quantifying the amount of radiation noise in an image does not adequately explain how it may interfere with higher level navigation and perception tasks. Second, radiation estimation procedures rely on focusing the camera on a known and static background. This is unsuitable for robotic exploration tasks, where the robot frequently moves around an unknown environment that may be dynamically changing. Our work contains two contributions that address these shortcomings. First, we conduct a detailed analysis of the noise radiation causes in cameras by exposing cameras that are commonly used on UAVs [e.g., small form factor complementary metal-oxide-semiconductor (CMOS) cameras] to varying levels of radiation that may be present in emergency scenarios. From this exposure, we quantify not only how much noise is present, but quantify its appearance. By quantifying the appearance and amount of noise in a camera image, researchers can design mitigation strategies for the corruption, so that their robotic systems can operate in these challenging environments. Second, we demonstrate how to leverage this experimental data in robotic simulations. Using data from the first set of experiments allows us to test and verify the robots in simulation. Using simulators allows us to verify the robots will perform as expected during critical times without needing expensive test equipment or damaging valuable robot prototypes. Other researchers using robots for exploration of irradiated environments will benefit from our research by incorporating similar noise models in their research. 1 Southwest Research Institute{sup R} is a registered trademark of Southwest Research Institute in the United States and/or other countries. This will increase the reliability of robotic systems prior to deployment in emergency situations, which will in turn increase their effectiveness and speed the development of robots that would otherwise need expensive and time-consuming test procedures to validate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Potential Dose and Environmental Impacts from Proposed Testing at the INL National Security Test Range

This assessment uses screening-level models to calculate potential environmental impacts from proposed tests at two locations at the Idaho National Laboratory (INL) National Security Test Range (NSTR) site. Proposed tests could be conducted using 11 different radioactive material types that include K 2 O, LaBr 3 , KBr, Cu, Zr, F, Ga, Ga 2 O 3 , NaNO 2 , Ga-68, and Tc-99m. The tests could potentially release radioactive material to the atmosphere and radionuclides and other contaminants to the soil, which could leach into the unsaturated zone and migrate to the aquifer. Atmospheric transport of radionuclides to potential human receptors and time-integrated air concentrations were calculated with a Gaussian plume model and three years of hourly meteorological data. Potential surface-soil impacts were calculated with the computer program mixing-cell model (MCM). Groundwater impacts were calculated with the computer programs MCM and GWSCREEN. Radiological doses from potential atmospheric releases were calculated for public receptors off the INL Site and for workers at nearby INL facilities. Results were compared to regulatory dose limits. Maximum potential groundwater concentrations were estimated in the aquifer below the NSTR site and compared to drinking water standards or risk-based screening levels for resident tap water. Soil concentrations were calculated and compared to risk-based screening levels for workers and potential future residents. All impacts were estimated based on the assumption that 12 tests are conducted annually using all 11 material types for 15 years. This document provides the resources to enable a subject matter expert in the field of environmental assessments to replicate the modeling and calculations. The methodology and parameters are presented in the text. All electronic files, including computer-code input, output, executable files, batch files, scripts, and spreadsheet files, are contained in a zip file that can be accessed by selecting “Additional Information” (select Native File) in the INL Electronic Document Management System (EDMS). It is highly unlikely the test scenarios evaluated in this ECAR will adversely impact human health based on comparisons of calculated dose and concentration against regulatory standards and risk-based screening levels. Conservative estimates of dose to workers and the public from atmospheric transport of possible radionuclide releases are far below federal radiation protection standards. Conservative estimates of potential contaminant concentrations in groundwater are less than federal drinking water standards or screening levels. Predicted radionuclide concentrations in surface soils are below risk-based screening levels, except for Ge-68 (material Ga-68) for the worker. The Ge-68 soil concentration can be made less than the worker PRG, if the number of annual tests using Ga-68 is reduced from 12 to 6. However, the sum of ratios still exceeds one because of the high K-40 ratio. If the EF of the worker (number of days the worker is in the contaminated testing area) is reduced from 225 days/yr (default value for full time worker) to 112 days/yr, the Ge-68 ratio is less than one and the sum of ratios is less than one. Actual radiation doses and groundwater and surface-soil concentrations are likely to be much less than those calculated because of the conservative assumptions and parameters employed in the modeling. For example, atmospheric-transport calculations assume the entire inventory of each material type is readily released to the atmosphere and no plume deposition, depletion, or radioactive decay occurs during transport. The calculations also assume the same meteorological conditions (e.g., wind velocity, wind direction, stability class) that produce the maximum 95th percentile concentration (i.e., concentration representing the 95th percentile of a distribution of concentrations derived from 3 years of hourly meteorological data) at each receptor location are the same for all 12 tests during the year, and each receptor is assumed to be present during all 12 tests. The surface-soil assessment assumes the entire inventory of each test is deposited in the top 5 cm of soil. No atmospheric dispersal is assumed, and the radionuclides are subject only to leaching and radioactive decay. The groundwater-pathway modeling is conservative in that it is one-dimensional in the unsaturated zone (no lateral spreading/dilution) and assumes the entire inventory of contaminants infiltrates into the ground at the same location for every test. This is especially conservative for particulate radionuclides because they would have to dissolve or corrode first and some would be dispersed into the atmosphere. The groundwater receptor is also assumed to consume water directly from a hypothetical well positioned in the location of maximum concentration. In addition, conservative degradation rates were used, and volatilization was not considered for the nonradradioactive chemicals modeled. And finally, the calculations assume all 12 tests will be performed at the same place at both locations, and all 11 radioactive material types will be used for each test. This is conservative because it is anticipated that no more than two material types will be used per test.

99 GENERAL AND MISCELLANEOUS↗

A Grid Intensity Map-Based Source Model for Monte Carlo Modeling of IMRT Field Irradiation - Paper 5

An accurate source model is important for TPS (Treatment Planning System) dose calculation and verification, especially for IMRT (Intensity Modulated Radiotherapy) irregular and inhomogeneous fields. Monte Carlo simulation is the most accurate way to calculate dose distributions in the heterogeneous media like human bodies. A full radiotherapy modeling generally includes Linac modeling and phantom dose calculation. Full Linac modeling is very time-consuming and requires highly detailed knowledge of the accelerator composition and structure, however, which is very difficult to obtain for commercial interests. Often all relevant parameters are not known with sufficient accuracy, and thus a time-consuming tuning of e.g. the electron beam spot size and energy must be performed. A multiple source model (MSM) regards particles coming from different parts of an accelerator as if they are coming from different virtual sources. MSM uses a set of virtual sources representing the treatment beam (e.g. primary photons, head scatter, electron contamination) by a set of analytic functions or histograms with parameters derived from dosimetric measurements or a full MC simulation. Tillikainen et al built a three sub-source model by matching with measurement data using an automatic process to optimize the free model parameters for a Varian 2100 C/D accelerator. Lin et al have built a convenient five-photon-sub-source model for Varian 2300C 6 MV-X beam based on Monte Carlo simulated Linac for ARTS (Accurate Radiotherapy System). The particle generation of MSM is very fast compared to full Linac simulation, and its sampling efficiency is not limited by the size of the phase space file (PSF). However, generally MSM is generated based on regular field PSF and needs an irregular component to form the beam shape meanwhile apt to bringing error Linac modeling and MSM producing from PSF analysis actually both are multi-freedom optimization process by adjusting several parameters (e.g. electron energy and angular divergence). Linac modeling adjusts its parameters from the beginning of electron hitting target through all components to fit the simulation to the measurement. MSM tunes its PSF-derived parameters by optimizing to minimize the deviations between the simulation and the measurement. Since the full Linac modeling and the MSM model both need to fine tune their parameters to match the simulation to the measurement, and sometimes maybe offsets the real accelerator for its multi-parameter optimization process. So, why not fine tune directly all source model parameters just behind all Linac components to fit the simulation to the measurement? A grid intensity-based surface source model was suggested here, which assumed the particle emitting from the bottom surface of Linac last beam trimmer MLC (Multi Leaf Collimator). The particle emitting position is sampled on the grid intensity map optimized by TPS, and the particle weight is adjusted by its original grid intensity. This source model not only takes advantage of the Monte Carlo method in the heterogeneous media, but also avoids effectively the transportation speed shortcoming of Monte Carlo simulation through Linac components. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

SIMULATED HUMAN ERROR PROBABILITY AND ITS APPLICATION TO DYNAMIC HUMAN FAILURE EVENTS

Abstract Objectives: Human reliability analysis (HRA) methods typically analyze human failure events (HFEs) at the overall task level. For dynamic HRA, it is important to model human activities at the subtask level. There exists a disconnect between dynamic subtask level and static task level that presents issues when modeling dynamic scenarios. For example, the SPAR-H method is typically used to calculate the human error probability (HEP) at the task level. As demonstrated in this paper, quantification in SPAR-H does not translate to the subtask level. Methods: Two different discrete distributions were generated for each SPAR-H Performance Shaping Factor (PSF) to define the frequency of PSF levels. The first distribution was a uniform, or uninformed distribution that assumed the frequency of each PSF level was equally likely. The second non-continuous distribution took the frequency of PSF level as identified from an assessment of the HERA database. These two different approaches were created to identify the resulting distribution of the HEP. The resulting HEP that appears closer to the known distribution, a log-normal centered on 1E-3, is the more desirable. Each approach then has median, average and maximum HFE calculations applied. To calculate these three values, three events, A, B and C are generated from the PSF level frequencies comprised of subtasks. The median HFE selects the median PSF level from each PSF and calculates HEP. The average HFE takes the mean PSF level, and the maximum takes the maximum PSF level. The same data set of subtask HEPs yields starkly different HEPs when aggregated to the HFE level in SPAR-H. Results: Assuming that each PSF level in each HFE is equally likely creates an unrealistic distribution of the HEP that is centered at 1. Next the observed frequency of PSF levels was applied with the resulting HEP behaving log-normally with a majority of the values under 2.5% HEP. The median, average and maximum HFE calculations did yield different answers for the HFE. The HFE maximum grossly over estimates the HFE, while the HFE distribution occurs less than HFE median, and greater than HFE average. Conclusions: Dynamic task modeling can be perused through the framework of SPAR-H. Identification of distributions associated with each PSF needs to be defined, and may change depending upon the scenario. However it is very unlikely that each PSF level is equally likely as the resulting HEP distribution is strongly centered at 100%, which is unrealistic. Other distributions may need to be identified for PSFs, to facilitate the transition to dynamic task modeling. Additionally discrete distributions need to be exchanged for continuous so that simulations for the HFE can further advance. This paper provides a method to explore dynamic subtask to task translation and provides examples of the process using the SPAR-H method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗