Search NASA⌕ Search

SEARCH · Search NASA

Results for “Concentration of measure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Positive and Negative Ion CIMS Measurements, SGP, May-June 2024

The negative ion measurements were taken using two LTOF-CIMS with two different nitrate inlets. The data labeled Aerodyne_Inlet used an Aerodyne nitrate inlet. Data labeled PCC used a custom transverse inlet. The positive ion measurements were taken using one LTOF-CIMS with hydronium as an ionization reagent using a custom transverse inlet with an inlet voltage difference of 700 V. See https://doi.org/10.1021/acs.jpca.2c01672 for more information. Peaks were autofit using tofware. Positive ion data is published in the form of peak signal/reagent signal. Data files of peak signal/reagent signal for the two mass spectrometers for the negative ion measurements are separate. Concentrations of H2SO4 are combined into one file. When measurements were overlapping, measurements from the Aerodyne nitrate inlet were used.

54 ENVIRONMENTAL SCIENCES↗

Exploration of ICP platforms for measuring elemental impurities in uranium ore concentrates

Presented here is a look at different inductively coupled plasma (ICP) platforms including sector field, triple quadrupole mass spectrometric configurations, and optical emission spectroscopy. The goal of this paper was to convey the feasibility of trace elemental analysis of a uranium ore concentrate with varying ICP-based platforms. It was predicted that low mass elements would be better determined through optical means, or the mass collision/reaction technology of the triple quadrupole mass spectrometer, in comparison to high resolution measurements of magnetic sector-based configurations. Ultimately, it is difficult to achieve an “optimal” analysis of 20+ elements, for numerous samples, on a single platform, especially when time, measurement reproducibility, sensitivity, and robustness should be considered. The work presented here highlights the advantages and disadvantages of the respective trace elemental analysis platforms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of quantitative synchrotron radiation micro-X-ray fluorescence in rice grain

Concentrations of nutrients and contaminants in rice grain affect human health, specifically through the localization and chemical form of elements. Methods to spatially quantify the concentration and speciation of elements are needed to protect human health and characterize elemental homeostasis in plants. Here, an evaluation was carried out using quantitative synchrotron radiation microprobe X-ray fluorescence (SR-µXRF) imaging by comparing average rice grain concentrations of As, Cu, K, Mn, P, S and Zn measured with rice grain concentrations from acid digestion and ICP-MS analysis for 50 grain samples. Better agreement was found between the two methods for high-Z elements. Regression fits between the two methods allowed quantitative concentration maps of the measured elements. These maps revealed that most elements were concentrated in the bran, although S and Zn permeated into the endosperm. Arsenic was highest in the ovular vascular trace (OVT), with concentrations approaching 100 mg kg –1 in the OVT of a grain from a rice plant grown in As-contaminated soil. Quantitative SR-µXRF is a useful approach for comparison across multiple studies but requires careful consideration of sample preparation and beamline characteristics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A near-infrared optical nanosensor for measuring aerobic respiration in microbial systems

We developed a ratiometric oxygen-sensitive nanosensor and demonstrated application in monitoring metabolic oxygen consumption in microbial samples over time. Based on a near-infrared (NIR) emitting oxygen-quenched luminophore, platinum(II) octaethylporphine ketone (PtOEPK), along with a stable dioctadecyl dicarbocyanine reference dye (DiD), this nanosensor system provides an advantageous approach for overcoming imaging issues in biological systems, such as autofluorescence and optical scattering in the visible wavelength region. The dyes are encapsulated within a polymer-based nanoparticle matrix to maintain them at a constant ratio in biological samples, precluding the need for complex synthetic approaches. With this constant ratio of the two dyes, the nanosensor response can be measured as a ratio of their two signals, accounting for nanosensor concentration artifacts in measurements. The nanosensors are reversible, which enabled us to temporally monitor systems in which dissolved oxygen concentrations both increase and decrease. These sensors were applied for the monitoring of oxygen in samples of Saccharomyces cerevisiae (brewing yeast) in a 96-well optical fluorescence plate reader format over 60 h. By mixing the nanosensors directly into the sample well with the yeast, we were able to dynamically track metabolic activity changes over time due to varying cell concentration and exposure to an antimicrobial agent. As a result, this system could be a potential platform for high-throughput screening of various species or variants of microbes with unknown metabolic rates in response to external stimuli (antimicrobials, metabolites, etc.).

59 BASIC BIOLOGICAL SCIENCES↗

Diffusion Quantum Monte Carlo Benchmarking of Magnetic Moments in MnBi 2 Te 4

The intrinsically antiferromagnetic topological insulator, MnBi 2 Te 4 (MBT), has garnered significant attention recently due to its potential to host numerous exotic topological quantum states. Unfortunately, their consistent realization has been hindered by intrinsic antisite defects among the Mn and Bi sublattices. In this work, we establish Mn magnetization of pristine MBT through high level diffusion Monte Carlo calculations, which can serve as a precise starting point for various models to estimate antisite defect concentrations in actual MBT samples. The benchmark quality of DMC calculations is further identified from out model estimating antisite defect concentrations, which combines the benchmarked Mn magnetization with data from magnetic susceptibility and intermediate field magnetization measurements. This reproduces well Bi Mn and Mn Bi concentrations measured in the experiments. Here, we anticipate these theoretically based magnetic purity measures may be used as minimization targets in cycles of refinement to synthesize MBT with low antisite defect concentrations and more reproducible topological properties.

Defects↗

High sensitivity measurement of femtogram-level 238 Pu by thermal ionization mass spectrometry with correction of background 238 U

Low-concentration plutonium isotopic measurements provide a valuable fingerprint to identify possible material origins in the context of environmental contamination monitoring, environmental tracing, nuclear safeguards, nuclear forensics, and treaty monitoring. Thermal ionization mass spectrometry (TIMS) has long been recognized as one of the most sensitive techniques for plutonium isotopic measurement, but has not generally been utilized for 238 Pu determination, especially at low concentrations, due to an isobaric interference from 238 U, prevalent as background. Here, this work demonstrates a new analytical technique for correction of background 238 U from the 238 Pu counts collected during a TIMS analysis. The technique takes advantage of the higher ionization temperature of U relative to Pu and uses a 235 U tracer added after plutonium purification chemistry for 238 U semi-quantitative determination. This technique has been successfully applied to the determination of 238 Pu concentration and the 238 Pu/ 239 Pu ratio in sample types including single-isotope standards, isotopic certified reference materials, matrix-containing environmental reference materials, and simulated nuclear detonation debris. The results have been directly compared on a sample-by-sample basis to alpha spectrometry results. The detection limit by this new technique is 0.23 fg 238 Pu, which was previously unachievable by mass spectrometry and is possible in around 1 h of analysis time post-chemistry compared to weeks of required counting time by alpha spectrometry (at the same atom amount). We also present original, high precision data for Pu isotope concentrations in IAEA-384, Fangataufa Sediment, including 242 Pu results for the first time. The new technique allows measurement of a key isotope, 238 Pu, that was previously not measured in small environmental or nuclear forensics collections.

238Pu↗

A proposed high-intensity radiometer calibration method using concentrated solar radiation

Accurate calibration of irradiance measurement devices, or radiometers, is essential for ensuring the reliability of measurements in high heat applications such as concentrating solar power (CSP), aerospace, defense, and pulsed power systems. Despite the critical need, existing calibration standards and service providers are limited to irradiance levels below 100 kW/m 2 and specific radiation sources, which is insufficient for many applications. For instance, CSP technologies, particularly those under the Department of Energy’s Solar Energy Technologies Office (SETO) Gen 3 program, require accurate measurements of broadband irradiance at levels exceeding 2000 kW/m 2 . In even more extreme scenarios, such as re-entry vehicles, heat levels can surpass 10000 kW/m 2 . Current ISO standards, specifically ISO 14934–2 and ISO 14934–3, are constrained to lower irradiance levels and dependent on black body heat sources, limiting their applicability for high-intensity broadband irradiance measurements, particularly in concentrated solar applications. Here, to address this shortfall, the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL) proposes a calibration method and facility capable of characterizing radiometers up to 2750 kW/m 2 using concentrated solar irradiance. Calibrating with concentrated sunlight is important for solar applications as it aligns the calibration process with the solar spectrum. This alignment is crucial for minimizing systematic errors and avoiding the need for additional corrections that may arise when radiometers designed for solar applications are calibrated using black-body or electrical sources. This paper presents the present day NSTTF characterization facility and procedure, detailing the proposed calibration method and uncertainty quantification. The presented method builds upon 1980′s NSTTF methodology and involves both theoretical and empirical methods to establish a robust relationship between gauge voltage output and irradiance intensity, quantifying both measurement and fitting errors. By addressing the limitations of existing standards and extending the characterization range, this work provides an advancement in the field of high-intensity irradiance measurement and instrumentation characterization.

Gardon gauge↗

Observations of Nocturnal Sulfuric Acid Formation in Pittsburgh, PA

Measurements of sulfuric acid (H 2 SO 4 ) and sulfur trioxide (SO 3 ) were conducted in Pittsburgh, Pennsylvania, during field campaigns in Fall 2023 and Fall 2024. These measurements identified nocturnal concentrations of H 2 SO 4 comparable to those of daytime values. Nocturnal H 2 SO 4 concentrations were observed to increase by 5 × 10 5 to 5 × 10 7 molecules cm –3 above background on 16 of the 31 measurement nights. The median peak concentration during events was 6.5 × 10 6 molecules cm –3 , with a maximum of 1.0 × 10 8 molecules cm –3 , exceeding previously reported nighttime concentrations. Increases in H 2 SO 4 concentrations were positively correlated with the anomalously high SO 3 concentrations and condensation sink rates, indicating that the formation of H 2 SO 4 increased to overcome the loss rates to particles. Increases in particulate mass and the mass fraction of metals commonly emitted from coal combustion and steel production were also observed. The air masses were traced back to the southeast of Pittsburgh, a region home to a steel mill, coke plant, and a steel processing plant. The observations indicate a previously unrecognized nighttime formation pathway for H 2 SO 4 , potentially from heterogeneous catalysis with metal or black carbon, originating from steel and coke plant emissions. Further measurements are needed to identify key compounds and chemical processes driving these increases in nocturnal H 2 SO 4 concentrations.

aerosols↗

Bismuth Detection in Alkaline Electrolyte via Anodic Stripping Voltammetry for Battery Separator Evaluation

Abstract Anodic stripping voltammetry (ASV) has been widely used for the detection of several heavy metal ions in neutral and acidic solution, in many cases employing electrodes and/or solutions incorporating Bi. In this work we demonstrate that Bi(OH) 4 − ion concentration can be measured in highly alkaline 8.5 M KOH solution using ASV. The addition of Pb in similar concentrations to the Bi(OH) 4 − being measured is shown to improve both the sensitivity and precision of the method. When the Pb additive is employed, a formal limit of detection of 8.5 ppb is achieved, compared to 17.3 ppb when the Pb additive is not used. Due to the use of Bi additives in alkaline battery chemistries, it follows that separators which limit Bi(OH) 4 − diffusion into the bulk electrolyte and away from the electrodes are of interest. For this purpose, we utilize ASV to determine Bi(OH) 4 − diffusion rates through Celgard 3501, cellophane 350P00, and Nafion 211. Bi(OH) 4 − crossover rates, as determined by ASV, are shown to be repeatable and consistent with expectations from the known separator structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrochemical Study on the Kinetic Properties of Fe 2+ /Fe, Ni 2+ /Ni, Cr 2+ /Cr and Cr 3+ /Cr 2+ in Molten MgCl 2 -KCl-NaCl Salts

Here, the fundamental kinetic parameters of corrosion product ions (Fe, Ni and Cr ions) are of significant importance to understand the corrosion mechanisms of the structural materials in the molten salts. In the present study, the fundamental data of Fe 2+ , Ni 2+ , Cr 2+ and Cr 3+ (diffusion coefficient D, exchange current density i 0 , charge transfer coefficient α, limiting current density i L and standard rate constant k0) were measured at different concentrations (1.53 × 10 –6 –7.48 × 10 –4 mol cm –3 ) and temperatures (600 °C–800 °C). The values of D are independent of concentrations and follow Arrhenius law with temperature, which descend in the order of D Cr 2+ > D Fe 2+ > D Cr 3+ > D Ni 2+ with values ranging from 0.94 × 10 –5 to 3.31 × 10 –5 cm 2 s –1 . Both i 0 and k 0 depend on the temperatures, which also follow Arrhenius law.

14 SOLAR ENERGY↗

Comparison of near-background concentrations of Argon-37 and Xenon-133 in the Atmosphere

Radioisotopes of noble gases xenon and argon can be important indicators of underground nuclear explosions. The Comprehensive Nuclear-Test-Ban Treaty (CTBT) includes monitoring capabilities to identify potential nuclear explosions conducted in violation of the CTBT. This monitoring currently focuses on measurement of the xenon isotopes 133Xe, 135Xe, 131mXe and 133mXe. However, it is predicted that within 100 days of an underground nuclear explosion (UNE) 37Ar would be released to the atmosphere at higher concentrations than xenon isotopes (Haas et al. 2010) and with a higher signal to background ratio, depending on the radioxenon background levels. Therefore, inclusion of 37Ar measurement capabilities at atmospheric International Monitoring System (IMS) stations may represent an improvement in the capability to detect a nuclear explosion. At an IMS station, it could be difficult to determine what constitutes an elevated concentration as a result of an UNE without first understanding the expected range of background concentrations. This work describes our analysis of atmospheric samples for 37Ar to evaluate the range of background concentrations. Samples were collected at multiple locations, with approximately half coming from a sampler co-located with an IMS xenon monitoring station (RN75). The range of 37Ar concentrations measured in atmospheric air samples was relatively narrow; for samples considered detectable, the minimum and maximum measured concentrations were 0.56 and 2.3 mBq/m3, respectively. Comparison of 37Ar and 133Xe concentrations measured at the IMS station indicated some correlation between the measured concentrations. The results presented here demonstrate the capability to detect background concentrations of 37Ar in atmospheric air and provide a basis for potential implementation of 37Ar monitoring at IMS stations.

Fritz, Brad G.↗

Understanding effects of chemical complexity on helium bubble formation in Ni-based concentrated solid solution alloys based on elemental segregation measurements

Here, helium bubble formation and swelling were systematically studied in Ni-based concentrated solid solution alloys containing different numbers and types of elements. Our microscopy analysis showed that although increasing the alloy chemical complexity helps suppress bubble formation in general, there is no monotonic relationship between the bubble growth rate and the number of alloying elements. Certain elements (e.g., Fe and Pd) are more effective in suppressing bubble growth than others (e.g., Cr and Mn). Atom probe tomography was applied to accurately measure elemental segregation around bubbles, revealing unique effects of certain alloying elements on vacancy migration towards bubbles. More specifically, the high vacancy mobility via Cr sites leads to a large vacancy flux and an increased bubble size, while the high degree of atomic size mismatch introduced by Pd helps deflect vacancy flow away from bubbles and decrease the amount of swelling. The effects identified in this study provide new strategies to design concentrated solid solutions with superior resistance to swelling.

36 MATERIALS SCIENCE↗

Accumulation of trace elements in soil and fauna within a site historically contaminated with coal combustion residues

Legacy contaminants tied to energy production are a worldwide concern. Coal combustion residues (CCRs) contain high concentrations of potentially toxic trace elements such as arsenic (As), mercury (Hg), and selenium (Se), which can persist for decades after initial contamination. Coal combustion residue disposal methods, including aquatic settling basins and landfills, can facilitate environmental exposure through intentional and accidental releases. Wildlife exposed to CCRs can experience numerous deleterious effects, such as on development, reproduction, and survival. In the current study, we quantified and compared concentrations of As, Hg, Se, and strontium (Sr) within soils and target fauna (three vertebrate and three invertebrate taxa) from a CCR-contaminated site and a reference site within the U.S. Department of Energy’s Savannah River Site, South Carolina, United States. Our objectives were to (1) compare current concentrations of tested elements in soil and resident fauna to levels from our reference site, (2) assess natural attenuation of elements in soils by comparing current concentrations to historic levels, and (3) evaluate the biomagnification potential of the elements measured via body burden and trophic position correlations among fauna. Here, element concentrations were higher in contaminated soils than reference soils; however, concentrations in 2022 were unchanged from concentrations measured in 2003, suggesting no natural attenuation of tested elements. Additionally, target fauna had elevated As, Se, and Sr levels in comparison to reference samples. A positive correlation was observed in southern toads between Sr concentrations and trophic position, as assessed by nitrogen stable isotope ratios, suggesting potential for biomagnification of Sr within our study system. Collectively, our results demonstrate that legacy contaminants are still present and bioaccumulate in a diversity of taxa in a CCR-contaminated site that has not received effluents in more than 50 years, suggesting monitoring programs in CCR-contaminated sites should be maintained long term in the absence of remediation.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Temporal deposition of copper and zinc in the sediments of metal removal constructed wetlands

The objective of this study was to explore the effects of time, seasons, and total carbon (TC) on Copper (Cu) and Zinc (Zn) deposition in the surface sediments. This study was performed at the H-02 constructed wetland on the Savannah River Site (Aiken, SC, USA). Covering both warm (April-September) and cool (October-March) seasons, several sediment cores were collected twice a year from the H-02 constructed wetland cells from 2007 to 2013. Total concentrations of Cu and Zn were measured in the sediments. Concentrations of Cu and Zn (mean ± standard deviation) in the surface sediments over 7 years of operation increased from 6.0 ± 2.8 and 14.6 ± 4.5 mg kg -1 to 139.6 ± 87.7 and 279.3 ± 202.9 mg kg -1 dry weight, respectively. The linear regression model explained the behavior and the variability of Cu deposition in the sediments. On the other hand, using the generalized least squares extension with the linear regression model allowed for unequal variance and thus produced a model that explained the variance properly, and as a result, was more successful in explaining the pattern of Zn deposition. Total carbon significantly affected both Cu ( p = 0.047) and Zn ( p < 0.001). Time effect on Cu deposition was statistically significant ( p = 0.013), whereas Zn was significantly affected by the season ( p = 0.009).

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Thermolytic Production of Hydrogen from Glycolate and Common Tank Farm Organics in Simulated Waste

The Savannah River National Laboratory (SRNL) has performed testing to investigate the thermolytic production of hydrogen gas from organic species present in the Savannah River Site (SRS) Concentration, Storage, and Transfer Facilities (CSTF). SRNL designed an experimental apparatus to measure the timedependent concentration of hydrogen in the headspace over a reacting mixture of simulated caustic waste media and organic compounds as well as a methodology to calculate a steady-state hydrogen generation rate (HGR) from this data. Special focus was given to glycolate, which is not currently present in CSTF waste but will be contained in the recycle stream from the Defense Waste Processing Facility (DWPF) under the upcoming alternate reductant flowsheet.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Sensors for In-Situ Amine Degradation Monitoring in Post-Combustion Carbon Capture

In order to improve the long-term performance of post-combustion carbon capture technologies, improvements to the detection of solvent degradation or reduction in CO2 capture efficiency are necessary. A pair of sensors were deployed to the National Carbon Capture Center’s (NCCC) to monitor CO2 capture and solvent degradation. The CO2 sensors were located to measure before capture and after capture concentrations of CO2 to measure the capture efficiency of the solvent system. Amine degradation sensors were located at four locations along the main solvent lines corresponding to CO2 loading and temperature: hot rich, cold rich, hot lean, and cold lean. Experimental results from laboratory tests using the sensors are shown, along with prototype designs that were deployed to the field site.

Brister, Matthew↗