Search NASA⌕ Search

SEARCH · Search NASA

Results for “Configuration planning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Conjunction Assessment Screening Volume Sizing and Event Filtering in Light of Natural Conjunction Event Development Behaviors

Conjunction Assessment screening volumes used in the protection of NASA satellites are constructed as geometric volumes about these satellites, of a size expected to capture a certain percentage of the serious conjunction events by a certain time before closest approach. However, the analyses that established these sizes were grounded on covariance-based projections rather than empirical screening results, did not tailor the volume sizes to ensure operational actionability of those results, and did not consider the adjunct ability to produce data that could provide prevenient assistance for maneuver planning. The present study effort seeks to reconsider these questions based on a six-month dataset of empirical screening results using an extremely large screening volume. The results, pursued here for a highly-populated orbit regime near 700 km altitude, identify theoretical limits of screening volume performance, explore volume configuration to facilitate both maneuver remediation planning as well as basic asset protection, and recommend sizing principles that maximize volume performance while minimizing the capture of "chaff" conjunctions that are unlikely ever to become serious events.

screening volume↗

SU-F-T-35: Optimization of Bladder and Rectal Doses Using a Multi-Lumen Intracavitary Applicator for Gynecological Brachytherapy

Purpose: Radiation dose delivery for endometrial cancer using HDR techniques is limited by dose to bladder and rectum. A dosimetric study was performed using Varian Capri vaginal brachytherapy applicator to determine the optimal channel configuration which minimizes dose to bladder and rectum, while providing good target coverage. Methods: A total of 17 patients, 63 plans clinically delivered, and 252 simulated plans using Varian BrachyVision planning system were generated to investigate optimal channel configuration which results in minimum dose to bladder and rectum while providing adequate target coverage. The Capri applicator consists of 13 lumens arranged in two concentric rings, one central lumen and six lumens per ring. Manual dose shaping is invariably required to lower the dose to critical organs. Three-dimensional plans were simulated for 4 channel arrangements, all 13 channels, channel 12 o’clock (close to bladder) and 6 o’clock (close to rectum) deactivated, central channel deactivated, and central channel in addition to 12 o’clock and 6 o’clock deactivated. A relationship between V100, the volume that receives the prescribed dose, and the amount of curie-seconds required to deliver it, was established. Results: Using all 13 channels results in maximum dose to bladder and rectum. Deactivating central channel in addition to 12 o’clock and 6 o’clock resulted in minimizing bladder and rectum doses but compromised target coverage. The relationship between V100, the volume that receives the prescribed dose, and the curie seconds was found to be linear. Conclusion: Deactivating channels 12 o’clock and 6 o’clock was shown to be the optimal configuration leading to minimum dose to bladder and rectum without compromising target coverage. The linear relationship between V100 and the curie- seconds can be used as a verification parameter.

60 APPLIED LIFE SCIENCES↗

An Altair Overview: Designing a Lunar Lander for 21st Century Human Space Exploration

Altair, the lunar lander element of NASA's Constellation program, was conducted in a different design environment than many other NASA projects of similar scope. Because of this relatively unique approach, there are a number of significant success stories that should be considered during the development of any future lunar landers or human spacecraft. This paper is divided into two separate themes; the first is the approach used during the conceptual design studies, including the systematic analysis cycles and the decision making process associated with each: and the second is a summary of the resulting lessons learned that were compiled after looking back at the lifetime of the Project. Altair was terminated before entering Phase B of its design, and was often criticized for being a very heavy and very large vehicle. While there was specific rationale for all of the decisions that led up to that configuration, future design cycles were specifically planned to re-address the mass challenge. Had the project continued, the deliberate, stepwise design process would have converged on an optimized lander design that balanced mass, risk, cost and capabilities. Some of the specific items that will be addressed in this paper include project development strategy, organizational approach and team dynamics, risk-informed design process, mission architecture constraints, mission key driving requirements, model-based systems engineering process, configuration studies, contingency considerations, subsystem overviews and key trade studies. The paper will conclude with a summary of the lessons identified during the Altair project and make suggestions for application to future studies.

Brown, Kendall K.↗

SU-F-T-48: Clinical Implementation of Brachytherapy Planning System for COMS Eye Plaques

Purpose: To commission the Brachytherapy Planning (BP) system (Varian, Palo Alto, CA) for the Collaborative Ocular Melanoma Study (COMS) eye plaques by evaluating dose differences against original plans from Nucletron Planning System (NPS). Methods: NPS system is the primary planning software for COMS-plaques at our facility; however, Brachytherapy Planning 11.0.47 (Varian Medical Systems) is used for secondary check and for seed placement configurations not originally commissioned. Dose comparisons of BP and NPS plans were performed for prescription of 8500 cGy at 5 mm depth and doses to normal structures: opposite retina, inner sclera, macula, optic disk and lens. Plans were calculated for Iodine-125 seeds (OncoSeeds, Model 6711) using COMS-plaques of 10, 12, 14, 16, 18 and 20 mm diameters. An in-house program based on inverse-square was utilized to calculate point doses for comparison as well. Results: The highest dose difference between BP and NPS was 3.7% for the prescription point for all plaques. Doses for BP were higher than doses reported by NPS for all points. The largest percent differences for apex, opposite retina, inner sclera, macula, optic disk, and lens were 3.2%, 0.9%, 13.5%, 20.5%, 15.7% and 2.2%, respectively. The dose calculated by the in-house program was 1.3% higher at the prescription point, and were as high as 42.1%, for points away from the plaque (i.e. opposite retina) when compared to NPS. Conclusion: Doses to the tumor, lens, retina, and optic nerve are paramount for a successful treatment and vision preservation. Both systems are based on TG-43 calculations and assume water medium tissue homogeneity (ρe=1, water medium). Variations seen may result from the different task group versions and/or mathematical algorithms of the software. BP was commissioned to serve as a backup system and it also enables dose calculation in cases where seeds don’t follow conventional placement configuration.

60 APPLIED LIFE SCIENCES↗

Evaluation of MLC leaf transmission on IMRT treatment plan quality of patients with advanced lung cancer

The purpose of this paper was to evaluate the impact of leaf treatment of multileaf collimator (MLC) in plan quality of intensity-modulated radiotherapy (IMRT) of patients with advanced lung cancer. Five MLCs with different leaf transmissions (0.01%, 0.5%, 1.2%, 1.8%, and 3%) were configured for an accelerator in a treatment planning system. Correspondingly, 5 treatment plans with the same optimization setting were created and evaluated quantitatively for each patient (11 patients total) who was diagnosed with advanced lung cancer. All of the 5 plans for each patient met the dose requirement for the planning treatment volumes (PTVs) and had similar target dose homogeneity and conformity. On average, the doses to selected organs were as follows: (1) V{sub 5}, V{sub 20}, and the mean dose of total lung; (2) the maximum and mean dose to spinal cord planning organ-at-risk volume (PRV); and (3) V{sub 30} and V{sub 40} of heart, decreased slightly when MLC transmission was decreased, but with no statistical differences. There is a clear grouping of plans having total quality score (S{sub D}) value, which is used to evaluate plan quality: (1) more than 1 (patient nos. 1 to 3, 5, and 8), and more than 2.5 (patient no. 6); (2) less than 1 (patient nos. 7 and 10); (3) around 1 (patient nos. 4, 9, and 11). As MLC transmission increased, overall S{sub D} values increased as well and plan dose requirement was harder to meet. The clinical requirements were violated increasingly as MLC transmission became large. Total S{sub D} with and without normal tissue (NT) showed similar results, with no statistically significant differences. Therefore, decrease of MLC transmission did have minimum impact on plan, and it improved target coverage and reduced normal tissue radiation slightly, with no statistical significance. Plan quality could not be significantly improved by MLC transmission reduction. However, lower MLC transmission may have advantages on lung sparing to low- and intermediate-dose exposure. Besides conventional fraction, hyperfraction, or stereotactic body radiotherapy (SBRT), the reduction on lung sparing is still essential because it is highly relevant to radiation pneumonitis (RP). It has potential to diminish incidence of RP and improve patient's quality of life after irradiation with lowered MLC transmission.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

IER 489: Critical Unresolved Region Integral Experiment (CURIE) CEDT Phase-2 Final Design

The final design for the CURIE integral benchmark experiment is presented in this report. Measurements will be performed on the Comet vertical assembly machine and include various critical configurations consisting of High Enriched Uranium (HEU) metal plates and Teflon moderator plates surrounded by a thick copper reflector. The various configurations with different Teflon plate thickness planned allow for complimentary measurements with differing nuclear data sensitivity in the Unresolved Resonance Region (URR). Similar to previously performed Zeus experiments, the proposed work will serve to validate vital nuclear data quantities and uncertainties and identify deficiencies in current radiation transport codes. Additionally, it will assess the applicability of optimization approaches to nuclear critical experiment design. The final experiment design is detailed in this report and includes design, optimization, uncertainty and continuous-energy nuclear data sensitivity analysis for the final experimental configurations that will provide the basis for a future benchmark evaluation intended for submission to the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook [1]. This document discusses the method, approach, considerations and final design chosen with conclusions. It also includes cost and schedule. The basis and principles of this document come from the preliminary design report [2]. Section 2 discusses the content and potential impact; section 3 gives an overview of the nuclear data and unresolved resonance region; section 4 gives a summary of the work done during the preliminary design; section 5 discusses the machine learning method and principles used for final design; section 6 summaries the results from final design; section 7 provides conclusions and the range of configurations chosen to carry forward to experiment execution; and section 8 includes a summary of costs.

42 ENGINEERING↗

Supersonic control effectiveness for full and partial span elevon configurations on a 0.0165 scale model space shuttle orbiter tested in the LaRC unitary plan wind tunnel (LA49)

A wind tunnel test is reported on an early version of the space shuttle orbiter (designated 089B-139) 0.0165 scale model to systematically determine both longitudinal and lateral control effectiveness associated with various combinations of inboard, outboard, and full span wing trailing edge controls. The test Mach umbers were 2.5 and 4.63 over an angle of attack range from -4 deg to 42 deg at 0 deg sideslip.

Source record↗

V/STOL wind-tunnel testing

Factors influencing effective program planning for V/STOL wind-tunnel testing are discussed. The planning sequence itself, which includes a short checklist of considerations that could enhance the value of the tests, is also described. Each of the considerations, choice of wind tunnel, type of model installation, model development and test operations, is discussed, and examples of appropriate past and current V/STOL test programs are provided. A short survey of the moderate to large subsonic wind tunnels is followed by a review of several model installations, from two-dimensional to large-scale models of complete aircraft configurations. Model sizing, power simulation, and planning are treated, including three areas is test operations: data-acquisition systems, acoustic measurements in wind tunnels, and flow surveying.

Koenig, D. G.↗

Providing Levelized Cost and Waiting Time Inputs for HDV Hydrogen Refueling Station Planning: A Case Study of U.S. I-75 Corridor

Widespread use of diesel fuels in freight transportation leads to greenhouse gas (GHG) emissions that play an important role in air pollution. The air pollution, as well as the energy crisis, drives the transition from diesel fuel to cleaner and more energy-efficient fuels such as hydrogen fuels. With such a transition, the strategic planning and optimization of supporting refueling infrastructure along the national highway for heavy-duty vehicles (HDVs) become a necessity. Cost and service level are two essential factors to be considered in hydrogen refueling station location and capacity optimization. The service level in this study is assessed by the delay (waiting time) at fueling stations as well as the fueling demand fulfilled. To this end, this study presents a methodology to provide waiting time (delay) and levelized hydrogen fuel cost inputs under different station configurations (number of dispensers and fill rates) for hydrogen refueling station planning. Determining the station configurations based on the trade-off between the two inputs is further discussed. Particularly, this study points out that the levelized cost and waiting time are affected by hourly demand patterns and estimates the two inputs under different peak hour fueling demand scenarios. The results suggest that, with the same daily demand, the cost, as well as the waiting time, increases obviously with the peak hour demand. In the case study, the cost grows at least 30% when the peak hour visit frequency of the daily total visits increases from 5% (evenly distributed pattern) to 10% (the most common pattern for existing diesel fueling stations along I-75). Accounting for this peak hour effect in hydrogen refueling station planning is recommended. Overall, the waiting time model and cost analysis provide key inputs for optimizing hydrogen refueling station location and configurations based on anticipated refueling demand patterns. The paper is the second in a series that aims to build a comprehensive modeling plan and optimize hydrogen refueling infrastructure along the Interstate 75 (I-75) corridor for HDVs.

Liu, Yuandong↗

Comparing Simulation Results from CHARM and RotCFD to the Multirotor Test Bed Experimental Data

Advanced multirotor vertical flight aircraft concepts are emerging faster than rigorous individualized tests can investigate their utility and performance. There are several analysis tools that predict multirotor performance and flow characteristics, but the accuracy of these predictions is still being debated due to lack of experimental data from multirotor tests that are needed to validate the analyses. The objective of this paper is to simulate multirotor configurations using two different mid-fidelity rotorcraft analysis tools, Comprehensive Hierarchical Aeromechanics Rotorcraft Model (CHARM) and Rotorcraft Computational Fluid Dynamics (RotCFD), and compare the simulation results to experimental data from a wind tunnel test of the Multirotor Test Bed (MTB). The MTB, developed by NASA Ames Research Center, is a new capability for testing a wide array of advanced vertical take-off and landing (VTOL) rotor configurations, with a primary focus on testing in the U.S. Army 7-by 10-Foot Wind Tunnel at NASA Ames Research Center. The MTB was designed to allow adjustment of the vertical, lateral, and longitudinal placement of up to six rotors, as well as allow tilt adjustment of each rotor and pitch adjustment of the whole assembly. The six-axis load cells under each rotor give the MTB the capability of measuring the rotor performance in a wide array of configurations. The overall goal of the MTB project is to help gain a better understanding of the performance, control, interactional aerodynamics, and acoustics of multirotor and tilting-rotor systems. For the work presented here, the MTB data were used to validate RotCFD and CHARM results for several multirotor test configurations. With confidence in both analyses established by the validation exercise, additional simulations were performed to explore quadrotor configurations that will be tested during the MTB’s second wind tunnel entry planned for 2022. This second tunnel entry will examine quadrotor configurations that represent published NASA reference designs for urban air mobility concept vehicles. Results from this paper confirm the ability of RotCFD and CHARM to simulate multirotor aerodynamic interactions on individual rotor performance under edgewise forward-flight conditions.

CHARM↗

STATUS OF CHEMICAL CLEANING OF WASTE TANKS AT THE SAVANNAH RIVER SITE F TANK FARM CLOSURE PROJECT - 9114

Chemical Cleaning is currently in progress for Tanks 5 and 6 at the Savannah River Site. The Chemical Cleaning process is being utilized to remove the residual waste heel remaining after completion of Mechanical Sludge Removal. This work is required to prepare the tanks for closure. Tanks 5 and 6 are 1950s vintage carbon steel waste tanks that do not meet current containment standards. These tanks are 22.9 meters (75 feet) in diameter, 7.5 meters (24.5 feet) in height, and have a capacity of 2.84E+6 liters (750,000 gallons). Chemical Cleaning adds 8 wt % oxalic acid to the carbon steel tank to dissolve the remaining sludge heel. The resulting acidic waste solution is transferred to Tank 7 where it is pH adjusted to minimize corrosion of the carbon steel tank. The Chemical Cleaning flowsheet includes multiple strikes of acid in each tank. Acid is delivered by tanker truck and is added to the tanks through a hose assembly connected to a pipe penetration through the tank top. The flowsheet also includes spray washing with acid and water. This paper includes an overview of the configuration required for Chemical Cleaning, the planned flowsheet, and an overview of technical concerns associated with the process. In addition, the current status of the Chemical Cleaning process in Tanks 5 and 6, lessons learned from the execution of the process, and the path forward for completion of cleaning in Tanks 5 and 6 will also be discussed.

36 MATERIALS SCIENCE↗

Roman Space Telescope Coronagraph Engineering Design and Operating Concept

NASA’s Nancy Grace Roman Space Telescope (formerly known as WFIRST) is a flagship astrophysics mission planned for launch in 2025. The coronagraph instrument (CGI) on Roman will demonstrate the technology for direct imaging and spectroscopy of exoplanets around nearby stars. It will work with the obscured 2.4 meter diameter telescope and demonstrate starlight suppression that is up to 3 orders of magnitude deeper than the preceding space-based and ground-based coronagraphs by using active wavefront control in space with deformable mirrors. CGI has passed its Preliminary Design Review (PDR) in September 2019 and is working toward the instrument Critical Design Review (CDR) in the spring of 2021. We will describe the flow down of key and driving CGI requirements from high level performance to the instrument hardware and software, current instrument configuration and engineering design, operational concept planned for CGI observations, integrated modeling status, and performance predictions.

Tanga, Hong↗

A rule-based systems approach to spacecraft communications configuration optimization

An experimental rule-based system for optimizing user spacecraft communications configurations was developed at NASA to support mission planning for spacecraft that obtain telecommunications services through NASA's Tracking and Data Relay Satellite System. Designated Expert for Communications Configuration Optimization (ECCO), and implemented in the OPS5 production system language, the system has shown the validity of a rule-based systems approach to this optimization problem. The development of ECCO and the incremental optimization method on which it is based are discussed. A test case using hypothetical mission data is included to demonstrate the optimization concept.

Rash, James L.↗

A rule-based systems approach to spacecraft communications configuration optimization

An experimental rule-based system for optimizing user spacecraft communications configurations was developed at NASA to support mission planning for spacecraft that obtain telecommunications services through NASA's Tracking and Data Relay Satellite System. Designated Expert for Communications Configuration Optimization (ECCO), and implemented in the OPS5 production system language, the system has shown the validity of a rule-based systems approach to this optimization problem. The development of ECCO and the incremental optimizatin method on which it is based are discussed. A test case using hypothetical mission data is included to demonstrate the optimization concept.

Rash, James L.↗

NASA's Space Launch System: Deep-Space Delivery for SmallSats

Designed for human exploration missions into deep space, NASA's Space Launch System (SLS) represents a new spaceflight infrastructure asset, enabling a wide variety of unique utilization opportunities. While primarily focused on launching the large systems needed for crewed spaceflight beyond Earth orbit, SLS also offers a game-changing capability for the deployment of small satellites to deep-space destinations, beginning with its first flight. Currently, SLS is making rapid progress toward readiness for its first launch in two years, using the initial configuration of the vehicle, which is capable of delivering more than 70 metric tons (t) to Low Earth Orbit (LEO). Planning is underway for smallsat accomodations on future configurations of the vehicle, which will present additional opportunities. This paper will include an overview of the SLS vehicle and its capabilities, including the current status of progress toward first launch. It will also explain the current and future opportunities the vehicle offers for small satellites, including an overview of the CubeSat manifest for Exploration Mission-1 in 2018 and a discussion of future capabilities.

Robinson, Kimberly F.↗

Lunar lander configuration study and parametric performance analysis

Future Lunar exploration plans will call for delivery of significant mounts or cargo to provide for crew habitation, surface tansportation, and scientific exploration activities. Minimization of costly surface based infrastructure is in large part directly related to the design of the cargo delivery/landing craft. This study focused on evaluating Lunar lander concepts from a logistics oriented perspective, and outlines the approach used in the development of a preferred configuration, sets forth the benefits derived from its utilization and describes the missions and system considered. Results indicate that only direct-to-surface downloading of payloads provides for unassisted cargo removal operations imperative to efficient and low risk site buildup, including the emplacement of Space Station derivative surface habitat modules, immediate cargo jettison for both descent abort and emergency surface ascent essential to piloted missions carrying cargo, and short habitat egress/ingress paths necessary to productive surface work tours for crew members carrying hand held experiments, tools and other bulky articles. Accommodating cargo in a position underneath the vehicles structural frame, landing craft described herein eliminate altogether the necessity for dedicated surface based off-loading vehicles, the operations and maintenance associated with their operation, and the precipitous ladder climbs to and from the surface that are inherent to traditional designs. Parametric evaluations illustrate performance and mass variation with respect to mission requirements.

Donahue, Benjamin B.↗

Flight testing the fixed-wing configuration of the Rotor Systems Research Aircraft (RSRA)

The Rotor Systems Research Aircraft (RSRA) is a unique research aircraft designed to flight test advanced helicopter rotor system. Its principal flight test configuration is as a compound helicopter. The fixed wing configuration of the RSRA was primarily considered an energy fly-home mode in the event it became necessary to sever an unstable rotor system in flight. While it had always been planned to flight test the fixed wing configuration, the selection of the RSRA as the flight test bed for the X-wing rotor accelerated this schedule. This paper discusses the build-up to, and the test of, the RSRA fixed wing configuration. It is written primarily from the test pilot's perspective.

Hall, G. W.↗

Tracking and Data Relay Satellite System (TDRSS) frequency plan

The functions of the Tracking and Data Relay Satellite System (TDRSS) are discussed. The primary purpose of the system is to transmit signals to and receive signals from earth orbiting user spacecraft, and provide data from which user spacecraft ephemerides can be calculated. The system configuration is described and illustrated. The frequency plan is analyzed to show the frequency coverage and the signal handling capability of the system. The characteristics of the components of the system are tabulated.

Source record↗