Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A control system of a negative hydrogen ion sources by using an EPICS-based proportional-integral-derivative

We have developed an EPICS-based control system for a multicusp negative ion source based on a VME IOC software, a sequencer controlling a closed proportional integral (PI) loop, and an interlock. The PI loop was tuned by a step input voltage, and tuning gains of the proportion and integral have been determined. The PI logics, developed by using standard proportional-integral-derivative records, can control the arc current within {+-}1% of a given set value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent Developments of the Modelica"Buildings" Library for Building Energy and Control Systems

At the Modelica 2009 conference, we introduced the Buildings library, a freely available Modelica library for building energy and control systems. This paper reports the updates of the library and presents example applications for a range of heating, ventilation and air conditioning (HVAC) systems. Over the past two years, the library has been further developed. The number of HVAC components models has been doubled and various components have been revised to increase numerical robustness.The paper starts with an overview of the library architecture and a description of the main packages. To demonstrate the features of the Buildings library, applications that include multizone airflow simulation as well as supervisory and local loop control of a variable air volume (VAV) system are briefly described. The paper closes with a discussion of the current development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Recovery Linac: Controls System

This paper examines the equipment and software from which the controls system interface for the Energy Recovery Linac (ERL) will be implemented at the Brookhaven National Laboratory.

43 PARTICLE ACCELERATORS↗

Device Classification for Industrial Control Systems Using Predicted Traffic Features

To achieve a secure interconnected Industrial Control System (ICS) architecture, security practitioners depend on accurate identification of network host behavior. However, accurate machine learning based host identification methods depends on the availability of significant quantities of network traffic data, which can be difficult to obtain due to system constraints such as network security, data confidentiality, and physical location. In this work, we propose a network traffic feature prediction method based on a generative model, which achieves high host identification accuracy. Furthermore, we develop a joint training algorithm to improve host identification performance compared to separate training of the generative model and the classifier responsible for host identification.

97 MATHEMATICS AND COMPUTING↗

Non-contact temperature control system for microfluidic devices

The present invention relates to a temperature control system for a microfluidic device. The system allows for non-contact heating by employing an infrared emitter. In some instances, the system can be used in conjunction with a centrifugal microfluidic device. Optionally, a mask can be implemented to provide selective heating of desired assay areas of the device.

Phaneuf, Christopher↗

Using EPICS enabled industrial hardware for upgrading control systems

Los Alamos National Laboratory has been working with National Instruments (NI) and Cosy lab to implement EPICS Input Output Controller (IOC) software that runs directly on NI CompactRIO Real Time Controller (RTC) and communicates with NI LabVIEW through a shared memory interface. In this presentation, we will discuss our current progress in upgrading the control system at the Los Alamos Neutron Science Centre (LANSCE) and what we have learned about integrating CompactRIO into large experimental physics facilities. We will also discuss the implications of using Channel Access Server for LabVIEW which will enable more commercial hardware platforms to be used in upgrading existing facilities or in commissioning new ones.

43 PARTICLE ACCELERATORS↗

Design of a Novel Information System for Semi-Automated Management of Cybersecurity in Industrial Control Systems

There is an urgent need in many critical infrastructure sectors, including the energy sector, for attaining detailed insights into cybersecurity features and compliance with cybersecurity requirements related to their Operational Technology (OT) deployments. Frequent feature changes of OT devices interfere with this need, posing a great risk to customers. One effective way to address this challenge is via a semi-automated cyber-physical security assurance approach, which enables verification and validation of the OT device cybersecurity claims against actual capabilities, both pre- and post-deployment. To realize this approach, this paper presents new methodology and algorithms to automatically identify cybersecurity-related claims expressed in natural language form in ICS device documents. Here, we developed an identification process that employs natural language processing (NLP) techniques with the goal of semi-automated vetting of detected claims against their device implementation. We also present our novel NLP components for verifying feature claims against relevant cybersecurity requirements. The verification pipeline includes components such as automated vendor identification, device document curation, feature claim identification utilizing sentiment analysis for conflict resolution, and reporting of features that are claimed to be supported or indicated as unsupported. Our novel matching engine represents the first automated information system available in the cybersecurity domain that directly aids the generation of ICS compliance reports.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Opdefender Network Monitoring And Control System

OpDefender is a new system designed to enhance the cyber security of control system networks. It accomplishes this by inspecting each network packet using a novel, patent-pending method that extends software defined networking into the application/ICS protocol layer. OpDefender consists of two key components: 1. Smart, “ICS-aware” network switches that analyze and filter network traffic in real time. 2. A network management human machine interface (HMI) that allows an operator to monitor and control network traffic in real time. The “ICS-aware” switches can serve as a drop-in replacement for typical network switches, or they can be used in conjunction with existing network switches. OpDefender is configured and controlled in real time via a custom-built, web-based HMI designed with the operator in mind.

Johnson, BriamE.↗

Energy Efficiency of Distributed Environmental Control Systems

In this report, we present an analytical evaluation of the potential of occupant-regulated distributed environmental control systems (DECS) to enhance individual occupant thermal comfort in an office building with no increase, and possibly even a decrease in annual energy consumption. To this end we developed and applied several analytical models that allowed us to optimize comfort and energy consumption in partitioned office buildings equipped with either conventional central HVAC systems or occupant-regulated DECS. Our approach involved the following interrelated components: 1. Development of a simplified lumped-parameter thermal circuit model to compute the annual energy consumption. This was necessitated by the need to perform tens of thousands of optimization calculations involving different US climatic regions, and different occupant thermal preferences of a population of ~50 office occupants. Yearly transient simulations using TRNSYS, a time-dependent building energy modeling program, were run to determine the robustness of the simplified approach against time-dependent simulations. The simplified model predicts yearly energy consumption within approximately 0.6% of an equivalent transient simulation. Simulations of building energy usage were run for a wide variety of climatic regions and control scenarios, including traditional “one-size-fits-all” (OSFA) control; providing a uniform temperature to the entire building, and occupant-selected “have-it-your-way” (HIYW) control with a thermostat at each workstation. The thermal model shows that, un-optimized, DECS would lead to an increase in building energy consumption between 3-16% compared to the conventional approach depending on the climate regional and personal preferences of building occupants. Variations in building shape had little impact in the relative energy usage. 2. Development of a gradient-based optimization method to minimize energy consumption of DECS while keeping each occupant’s thermal dissatisfaction below a given threshold. The DECS energy usage was calculated using the simplified thermal model. OSFA control; providing a uniform temperature to the entire building, and occupant-selected HIYW control with a thermostat at each workstation were implemented for 3 cities representing 3 different climatic regions and control scenarios. It is shown that optimization allows DECS to deliver a higher level of individual and population thermal comfort while achieving annual energy savings between 14 and 26% compared to OSFA. The optimization model also allowed us to study the influence of the partitions’ thermal resistance and the variability of internal loads at each office. These influences didn’t make significant changes in the optimized energy consumption relative to OSFA. The results show that it is possible to provide thermal comfort for each occupant while saving energy compared to OSFA Furthermore, to simplify the implementation of this approach, a fuzzy logic system has been developed to generalize the overall optimization strategy. Its performance was almost as good as the gradient system. The fuzzy system provided thermal comfort to each occupant and saved energy compared to OSFA. The energy savings of the fuzzy system were not as high as for the gradient-optimized system, but the fuzzy system avoided complete connectivity, and the optimization did not have to be repeated for each population. 3. We employed a detailed CFD model of adjacent occupied cubicles to extend the thermal-circuit model in three significant ways: (a) relax the “office wall” requirement by allowing energy to flow between zones via advection as well as conduction, (b) improve the comfort model to account both for radiation as well as convection heat transfer, and (c) support ventilation systems in which the temperature is stratified, such as in underfloor air distribution systems. Initially, three-dimensional CFD simulations of several cubicle configurations, with an adjoining corridor, were performed both to understand the advection between cubicles and the resulting temperature stratification. These simulations showed that the advective flow between cubicles is very significant and severely limits the occupants’ ability to control the personal micro-environments by simply controlling the temperature of the incoming air. Subsequently, the existing thermal-circuit model was extended to include the phenomena described above. The modifications to the thermal-circuit model, which were incorporated such that the simulation time was only slightly impacted, showed that accounting for room stratification resulting from the use of floor swirl diffusers could lead to 10%-26% reduction in the annual energy consumed for HVAC in non-temperate climates. This trend was evident in both OSFA and HIYW scenarios. However, the ratio of energy usage in the two scenarios was little affected by the enhancements in the thermal model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Discrepancy Checker for the Digital Twin in a Supervisory Control System for a Thermal Energy Delivery System

Defined as a virtual representation of a physical object, process, or service, and used to support real-world decision-making, a digital twin (DT) can be utilized to combine classical and novel frameworks in sensors, state predictions, and multi-input/multi-output systems, and to enable optimal autonomous operations. However, a DT’s usefulness largely depends on its ability to adequately mirror the state of its physical counterpart, and this adequacy should be reflected by the level of uncertainty in the underlying simulation models when estimating and predicting quantities of interest (QOIs). Moreover, simulation models in a DT may involve multiple fidelities of representations—ranging from physics-based models to data-driven ones—but classical uncertainty quantification (UQ) methods struggle to handle numerous uncertainty sources, nor are they designed for real-time applications. This work presents a UQ-based discrepancy checking and diagnosis tool for a DT-based supervisory control system applied to a thermal energy delivery system (TEDS) at Idaho National Laboratory. The discrepancy checker was developed using metadata from an automated DT development process, and these metadata included different combinations of physical model forms and model parameters, training data and hyperparameters for surrogate models, and design parameters for supervisory control systems. Next, correlations between the uncertainty results and the metadata were established and then applied to the DT operations. The discrepancy checker evaluates the discrepancies between model predictions from virtual and sensor measurements and backtraces them to the corresponding major sources of uncertainty. The discrepancy checker showed reasonable performance in detecting discrepancies and diagnosing sources of uncertainty in testing scenarios.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Control System Upgrade for Battery State-of-Charge Indications

The Advanced Test Reactor (ATR) Complex at Idaho National Laboratory (INL) relies on Battery Backed Power (BBP) systems and Uninterruptible Power Supplies (UPS) to ensure continuous power supply to critical components. This project aims to enhance the reliability and functionality of the battery monitoring and control systems by updating the State-of-Charge (SOC) system, Programmable Logic Controller (PLC), and Human-Machine Interface (HMI) for the nuclear safety-related battery banks. The current system, while functional, has areas for improvement, particularly in recharging calculations and alarm functions. The project objectives include developing flow charts, programming the new PLC and HMI, conducting bench tests, and updating design documentation. Additionally, the project ensures compliance with safety standards, develops training materials, creates comprehensive documentation, and integrates seamlessly with existing ATR infrastructure. The new SOC system is designed to be scalable for future upgrades, improve efficiency, enhance data accuracy, implement redundancy features, and achieve project goals within budget constraints while considering environmental impact. The methodology involved familiarizing with BBP and UPS systems, collecting current readings, rescaling signals, learning ladder logic, and updating the HMI. The transition from SLC 5/03 PLC using RS Logix 500 to CompactLogix 5380 using Studio 5000 was a key step. Despite challenges in transferring outdated PLC ladder logic and HMI code, starting from scratch led to a more accurate and efficient monitoring system, contributing to improved safety and operational efficiency. The project is currently awaiting approval of the Engineering Calculation and Analysis Report (ECAR) before implementation.

42 - ENGINEERING↗

Industrial Control Systems: Cyber Security Risk Candidate Methods Analysis

In recognition of their mission and in response to continuously evolving cyber threats against nuclear facilities, Department of Energy - Nuclear Energy (DOE-NE) is building the Nuclear Energy Cyber security Research, Development, and Demonstration (RD&D) Program, which includes a cyber risk management thrust. This report supports the cyber risk management thrust objective which is to deliver "Standardized methodologies for credible risk-based identification, evaluation and prioritization of digital components." In a previous task, the Sandia National Laboratories (SNL) team presented evaluation criteria and a survey to review methods to determine the most suitable techniques. In this task we will identify and evaluate a series of candidate methodologies. In this report, 10 distinct methodologies are evaluated. The overall goal of this effort was to identify the current range of risk analysis techniques that were currently available, and how they could be applied, with an focus on industrial control systems (ICS). Overall, most of the techniques identified did fall into accepted risk analysis practices, though they generally addressed only one step of the multi-step risk management process. A few addressed multiple steps, but generally their treatment was superficial. This study revealed that the current state of security risk analysis in digital control systems was not comprehensive and did not support a science-based evaluation. The papers surveyed did use mathematical formulation to describe the addressed problems, and tied the models to some kind of experimental or experiential evidence as support. Most of the papers, however, did not use a rigorous approach to experimentally support the proposed models, nor did they have enough evidence supporting the efficacy of the models to statistically analyze model impact. Both of these issues stem from the difficulty and expense associated with collecting experimental data in this domain.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Xcel Energy – LBNL ‘Beyond Widgets’ Project. Workstation Specific Lighting with Daylight Dimming Controls System Program Manual

This program manual was developed through a U.S. Department of Energy project to develop streamlined utility program approaches to the deployment of integrated systems in commercial offices. Integrated systems present deep opportunities for energy savings, however by nature these systems have additional levels of complexity and effort required for their design and energy savings assessment, which create barriers for utility incentive programs to develop streamlined cost effective incentive programs to capture these savings. This project worked with Xcel Energy in Colorado and Minnesota to select an integrated system and develop a streamlined approach to its deployment for small and large commercial offices. Xcel Energy worked with LBNL to select a workstation specific lighting system with daylight dimming controls, applied as a retrofit in commercial office spaces. Previous studies indicated a potential lighting annual energy savings of 28-63%, with an average of 47% for this system type, due to reduced fixture LPD and controls only, not including a full fixture replacement from a condition such as T8 to LED. Xcel also had a desire to incorporate this fixture replacement in their integrated system package, and as a result annual energy lighting savings are expected to be higher. FLEXLAB testing of the system for 500 lux minimum output conditions translated into a 94% annual energy savings for this system. Market analysis was developed for large and medium commercial office buildings in Xcel’s Minnesota and Colorado markets showing a potential for 48-295 and 120-672 GWh of energy savings potential for Colorado and Minnesota respectively. Total Resource Costs (TRC) vary by location and technology package used (enterprise versus non-enterprise lighting controls system), and vary from 0.29 to 1.27 and 0.06 and 0.44 for a Retrofit case, and 0.20 to 1.63 and 0.07 to 0.57 for a Replace on Burnout strategy for Colorado and Minnesota respectively. These results indicate good potential for demonstrating a strong technical and economic case for deployment of this system type in Xcel’s Colorado territory, while deployment in the Minnesota market may be advisable as well as part of a portfolio of programs, or as an effort to help shift the market into integrated systems deployment in general. It should be noted that the cost of avoided energy in both markets is significantly low ($0.07/kWh for Minnesota, $0.08/kWh for Colorado), and these TRC values would not be representative of deployment potential in other markets with higher utility rates. In addition, installation costs used for these systems may decrease with time, further enhancing their return on investment. Overall, workstation specific lighting systems with daylight dimming controls present a very strong potential for cost effective lighting energy savings, as demonstrated by the FLEXLAB test results and previous case studies. Further energy savings may be realized from the use of fixture-specific occupancy sensors as well, although this approach was not considered in this study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A compact low-level RF control system for advanced concept compact electron linear accelerator

A compact low-level RF (LLRF) control system based on RF system-on-chip (RFSoC) technology has been designed for the Advanced Concept Compact Electron Linear-accelerator (ACCEL) program, which has challenging requirements in both RF performance and size, weight, and power consumption (SWaP). The compact LLRF solution employs the direct RF sampling technique of RFSoC, which samples the RF signals directly without any analog upconversion and downconversion. Compared with the conventional heterodyne based architecture used for the LLRF system of a linear accelerator (LINAC), the elimination of analog mixers can significantly reduce the size and weight of the system, especially with LINAC requiring a larger number of RF channels. Based on the requirements of ACCEL, a prototype LLRF platform has been developed, and the control schemes have been proposed. The prototype LLRF system demonstrated magnitude and phase fluctuation levels below 1% and 1° on the flattop of a 2 μs RF pulse. The LLRF control schemes proposed for ACCEL are implemented with a prototype hardware platform. In conclusion, this paper will introduce the new compact LLRF solution and summarize a selection of experimental test results of the prototype itself and with the accelerating structure cavities designed for ACCEL.

Liu, C. [SLAC National Accelerator Laboratory (SLA↗

Human-System Interface Style Guide for ACORN Digital Control System

The purpose of this style guide is to assist developers in designing effective and consistent-looking user interfaces for accelerator control rooms. A similar purpose is to help developers avoid the creation of user interfaces that needlessly stray from the accepted standard set forth in this document. This way, all interfaces combined will look congruous. This is especially beneficial for development that spans multiple years by many different contributors. This document is intended as a ready reference source for all user interface design for the Fermilab accelerator complex.

43 PARTICLE ACCELERATORS↗

Modelica-based Modeling and Simulation to Support Research and Development in Building Energy and Control Systems

Traditional building simulation programs possess attributes that make them difficult to use for the design and analysis of building energy and control systems and for the support of model-based research and development of systems that may not already be implemented in these programs. This article presents characteristic features of such applications, and it shows how equation-based object-oriented modelling can meet requirements that arise in such applications. Next, the implementation of an open-source component model library for building energy systems is presented. The library has been developed using the equation-based object-oriented Modelica modelling language. Technical challenges of modelling and simulating such systems are discussed. Research needs are presented to make this technology accessible to user groups that have more stringent requirements with respect to the numerical robustness of simulation than a research community may have. Two examples are presented in which models from the here described library were used. The first example describes the design of a controller for a nonlinear model of a heating coil using model reduction and frequency domain analysis. The second example describes the tuning of control parameters for a static pressure reset controller of a variable air volume flow system. The tuning has been done by solving a non-convex optimization problem that minimizes fan energy subject to state constraints.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Effect of Degraded Digital Instrumentation and Control systems on Human-system Interfaces and Operator Performance

Integrated digital instrumentation and control (I&C) systems in new and advanced nuclear power plants (NPPs) will support operators in monitoring and controlling the plants. Even though digital systems typically are expected to be reliable, their potential for degradation or failure significantly could affect the operators performance and, consequently, jeopardize plant safety. This U.S. Nuclear Regulatory Commission (NRC) research investigated the effects of degraded I&C systems on human performance and on plant operations. The objective was to develop technical basis and guidance for human factors engineering (HFE) reviews addressing the operator's ability to detect and manage degraded digital I&C conditions. We reviewed pertinent standards and guidelines, empirical studies, and plant operating experience. In addition, we evaluated the potential effects of selected failure modes of the digital feedwater control system of a currently operating pressurized water reactor (PWR) on human-system interfaces (HSIs) and the operators performance. Our findings indicated that I&C degradations are prevalent in plants employing digital systems, and the overall effects on the plant's behavior can be significant, such as causing a reactor trip or equipment to operate unexpectedly. I&C degradations may affect the HSIs used by operators to monitor and control the plant. For example, deterioration of the sensors can complicate the operators interpretation of displays, and sometimes may mislead them by making it appear that a process disturbance has occurred. We used the findings as the technical basis upon which to develop HFE review guidance.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗