Search NASA⌕ Search

SEARCH · Search NASA

Results for “Controlled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Phasor Based Control with the Distributed, Extensible Grid Control Platform

This paper describes how to implement Phasor Based Control (PBC) using the Distributed, Extensible Grid Control (DEGC) Platform. PBC is a novel method for controlling distributed energy resources (DER) that coordinates a centralized optimization with distributed feedback controllers to enforce voltage phasor targets. DEGC is an open source software and communication platform designed for general DER control. We deployed PBC at Lawrence Berkeley Lab's FLEXLAB test site, conducting multiple hardware-in-the-loop test runs. Here, we describe how DEGC was used to implement PBC on hardware, and results demonstrating successful deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Investigation of Temperature Feedback Control Systems Applicable to Turbojet-engine Control

Temperature - fuel-flow and temperature-area feedback control systems were investigated as means of controlling tailpipe gas temperature of a turbojet engine during transient operation in the high-speed region. Proportional-plus-integral control was used in both systems, but in the temperature-area control system it was necessary to add nonlinear components to the basic proportional-plus-integral control to provide satisfactory transient response to a desired step increase in temperature. Time integral of temperature-error functions were used as criteria for determining optimum transient response. A description of engine dynamics was obtained from frequency-response data.

ENGINES, TURBOJET↗

Task Demand Variation in Air Traffic Control: Implications for Controller Workload, Fatigue, and Performance

In air traffic control, task demand and workload have important implications for the safety and efficiency of air traffic, and remain dominant considerations. Within air traffic control, task demand is dynamic. However, research on demand transitions and subsequent controller perception and performance is limited. This research uses an air traffic control simulation to investigate the effect of task demand transitions, and the direction of those transitions, on workload and fatigue and one efficiency performance measure. Results indicate that a change in task demand appears to affect both workload and fatigue ratings, although not necessarily performance. In addition, participants workload and fatigue ratings in equivalent task demand periods appear to change depending on the demand period preceding the time of the current ratings. Further research is needed to enhance understanding of demand transition and workload history effects on operator experience and performance, in both air traffic control and other safety-critical domains.

workload history↗

Comparison of Probabilistic Forecasts for Predictive Voltage Control

This paper explores predictive cooperative voltage control in distribution systems with highly variable sources such as photovoltaics (PV). The goal is to maintain the voltage profile within the limits despite the fluctuations due to sudden changes in solar power generation. The predictive voltage control method relies on probabilistic solar power and load forecasts to select the optimum Voltage Regulator (VR) taps appropriately. VR taps are selected to minimize the risk of voltage violation. A modified version of the IEEE 123 system is used as the case study. A 100% penetration of solar power is assumed for the distribution system with profiles for solar generation and loads added to the system. Three different probabilistic forecast models (Quantile Regression (QR), Gaussian distribution and volatility forecasting using Generalized Autoregressive Conditional Heteroskedasticity (GARCH)) are explored in this study. The results for the VR taps and Voltage Deviation Index (VDI) are compared to find the most effective forecast model.

Panamtash, Hossein↗

Nationwide HVAC Energy-Saving Potential Quantification for Office Buildings with Occupant-Centric Controls in Various Climates

The occupant-centric control (OCC) is receiving an increasing attention due to its ability to reduce building heating ventilation and air-conditioning (HVAC) system energy consumptions while not affecting the occupant thermal comfort. This paper aims to investigate and quantify the nationwide energy-saving potential of implementing the occupant-centric HVAC controls in typical office buildings using a whole building simulation software EnergyPlus. First, the medium office and large office from the Department of Energy (DOE) Commercial Prototype Building Models (CBPM) were enhanced to have detailed layouts and dynamic occupancy schedules. Then, a comprehensive simulation plan was created by incorporating the multiple zone-level and system-level occupant-centric building HVAC controls recommended by the updated ASHRAE Standard 90.1 – 2019 and ASHRAE Guideline 36 – 2018. Three control scenarios with different occupancy sensing methods were identified in this simulation plan. A nation-wide parametric analysis which includes two building types, three occupancy sensing scenarios, two building code versions, and 16 U.S. climate zones was carried out. The simulation results of the key control variables and HVAC energy consumption suggest that generally, both the occupancy presence sensor and occupant counting sensor could achieve energy savings for the office buildings in majority of the scenarios. However, compared with the occupancy presence sensor, which could support both the temperature setpoint reset and operational breathing zone airflow rate reset for the unoccupied zones, the occupant counting sensor only brings a marginal benefit. Besides, a higher HVAC energy-saving ratio could be achieved in the heating-dominated zone, since the energy reduction brought with the minimum outdoor airflow rate reset is stronger in the heating mode.

Pang, Zhihong↗

The QICK (Quantum Instrumentation Control Kit): Readout and control for qubits and detectors

We introduce a Xilinx RF System-on-Chip (RFSoC)-based qubit controller (called the Quantum Instrumentation Control Kit, or QICK for short), which supports the direct synthesis of control pulses with carrier frequencies of up to 6 GHz. The QICK can control multiple qubits or other quantum devices. The QICK consists of a digital board hosting an RFSoC field-programmable gate array, custom firmware, and software and an optional companion custom-designed analog front-end board. We characterize the analog performance of the system as well as its digital latency, important for quantum error correction and feedback protocols. We benchmark the controller by performing standard characterizations of a transmon qubit. We achieve an average gate fidelity of ℱ avg =99.93%. All of the schematics, firmware, and software are open-source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wind plant wake losses: Disconnect between turbine actuation and control of plant wakes with engineering wake models

Wake losses from neighboring plants may become a major factor in wind plant design and control as additional plants are constructed in areas with high wind resource availability. Because plant wakes span a large range of physical scales, from turbine rotor diameter to tens of kilometers, it is unclear whether conventional wake models or turbine control strategies are effective at the plant scale. Wake steering and axial induction control are evaluated in the current work as means of reducing the impact of neighboring wind plants on power and levelized cost of electricity. FLOw Redirection and Induction in Steady State (FLORIS) simulations were performed with the Gauss–Curl Hybrid and TurbOPark wake models as well as two operation and maintenance models to investigate control setpoint sensitivity to wake representation and economic factors. Both wake models estimate losses across a range of atmospheric conditions, although the wake loss magnitude is dependent on the wake model. Annual energy production and levelized cost of electricity are driven by wind direction frequency, with frequently aligned plants experiencing the greatest losses. However, both wake steering and axial induction are unable to mitigate the impact of upstream plants. Wake steering is constrained by plant geometry, since wake displacement is much less than the plant wake width, while axial induction requires curtailing the majority of turbines in upstream plants. Individual turbine strategies are limited by their effective scale and model representation. New wake models that include plant-scale physics are needed to facilitate the design of effective plant wake control strategies.

Scott, Ryan (ORCID:0000000328107574)↗

Differentiable Predictive Control with Safety Guarantees: A Control Barrier Function Approach

In this paper, we develop a novel form of differentiable predictive control (DPC) with safety and robustness guarantees. DPC is a form of approximate model predictive control (MPC), wherein the control policy is a neural network that learns a receding horizon, optimal control law. The proposed approach exploits a new form of sampled-data barrier function to enforce safety, while only interrupting the neural network-based controller near the boundary of the safe set. The effectiveness of the proposed approach is demonstrated in simulation.

Shaw Cortez, Wenceslao E.↗

An Artificial-Intelligence and Machine-Learning-Based Methodology to Conduct Seemingly Strain-Controlled Fatigue Test in a Pressurized-Water-Reactor-Test-Loop-Autoclave, While Not Controlling the Strain

In general, low cycle fatigue analysis of pressurized water reactor (PWR) components, requires strain-controlled fatigue test data such as using strain versus life (ε–N) curves. Conducting strain-controlled fatigue tests under in-air conditions is not an issue. However, controlling strain in a PWR-test-loop-autoclave is a challenge, since an extensometer cannot be placed in a narrow autoclave (typically used in a high-temperature-pressure PWR-test-loop). This is due to lack of space inside an autoclave that houses the test specimen. In addition, installing a contact-type extensometer in the path of a high-pressure flow can be a challenge. These difficulties of using an extensometer inside an autoclave led us to use an outside-autoclave displacement sensor which measures the displacement of pull-rod-specimen assembly. However, in our study (based on in-air fatigue test data), we found that a pull-rod-controlled based fatigue test can lead to substantial cyclic hardening/softening resulting in substantially different cyclic strain amplitudes and their rates compared to the desired cyclic strain amplitudes and its rates. In this paper, we propose an Artificial-Intelligence and Machine-Learning based technique such as using k-means clustering technique to improve the pull-rod-control based fatigue test method, such that the gage-area strain amplitude and rates can reasonably be achieved. In support of this, we present the fatigue test results for both 316 SS base and 81/182 dissimilar-metal-weld specimens.

42 ENGINEERING↗

Area 6 Control Point: An Architectural Survey of the Area 6 Control Point, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) proposes to demolish five buildings and five accessory resources in the Area 6 Control Point at the Nevada National Security Site (NNSS) in Nye County, Nevada. The demolition and removal of the buildings and accessories constitute an undertaking subject to review under Section 106 of the National Historic Preservation Act (NHPA) (54 United States Code [USC] § 306101) and its implementing regulations, 36 Code of Federal Regulations (CFR) Part 800. The buildings and accessories were recorded in Identification and Evaluation of 14 Architectural Resources Scheduled for Demolition, Area 6 Control Point and Vicinity, Nevada National Security Site, Nye County, Nevada (Menocal et al. 2020). The report found that the five buildings were not individually eligible for listing in the National Register of Historic Places (NRHP, National Register) but were potentially eligible as contributing elements to an unrecorded Area 6 Control Point district. The report also found that the five accessory resources were not individually eligible for the NRHP but they contributed to other historic properties, including the contributing elements to the unrecorded district. Finally, the report found that the undertaking would result in an adverse effect to historic properties. The State Historic Preservation Office (SHPO) concurred with the report’s findings regarding the eligibility of the buildings and structures in the Area of Potential Effect (APE) and that the undertaking would result in an adverse effect (Reed 2020). The NNSA/NFO, in consultation with the SHPO, then developed the Memorandum of Agreement DE-GM58-21NA25543 Between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Demolition of Fourteen Buildings and Structures in Area 6 of the Nevada National Security Site, Nye County, hereafter referred to as the MOA. The MOA stipulates that a district boundary be delineated with an accompanying boundary report and supporting photographs (Stipulation III.A) followed by an architectural survey of the potential historic district (Stipulation III.B). The SHPO reviewed and concurred with the proposed district boundary and accompanying boundary report and photographs (O’Neill et al. 2021) on August 23, 2021, in fulfillment of Stipulation III.A (Reed 2021). This architectural survey report has been prepared in accordance with Stipulation III.B. It includes an NRHP evaluation of the district, identifies contributing and non-contributing elements, and is accompanied by Architectural Resource Assessment (ARA) forms. The NRHP evaluation concludes that the Area 6 Control Point is recommended eligible as a historic district under the Secretary of the Interior’s Significance Criterion A at the national level as the location of the command center and various support facilities directly related to timing and firing operations for nuclear testing on the NNSS from 1951 to 1992. It is also recommended eligible under Significance Criterion C for embodying the distinctive characteristics of a nuclear command center in the context of the Cold War and as a significant and distinguishable entity. There are a total of 29 primary resources within the district boundary. Of these, 28 are recommended as contributing elements to the Area 6 Control Point Historic District and one is recommended as non-contributing.

54 ENVIRONMENTAL SCIENCES↗

Advanced Distributed Wind Turbine Controls Series: Part 1-Flatirons Campus Model Overview – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

Wind turbines are typically deployed to provide energy, reduce diesel-fuel consumption, reduce carbon emissions, and reduce costs for energy and fuel transportation. However, in addition to solely providing energy to the power system, wind turbines contain rotating masses and inverter-based controls that can enable various reliability and resilience services through advance controls. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL), it is demonstrated that advanced wind turbine controls can be employed to support higher contributions of wind, and to demonstrate ways that wind can play a role in supporting grid stability in islanded or grid-connected configurations. This paper documents models of various subsystem comprising a portion of NREL's Flatirons campus that will be used in three subsequent reports to demonstrate capabilities of advanced wind turbine controls. The series of reports will detail advanced capabilities of distributed wind turbines to provide support to isolated grids, distribution grids, and microgrids. We developed models to simulate a wind turbine (600 kW), solar PV (430 kW), battery energy storage system (1 MW/1MWh), a diesel generator (2 MW) and various types of loads (critical, dynamic). The model of the subsystems in MATLAB/Simulink are validated with available data from real-world components on NREL's Flatirons Campus. These validated models can be configured for various studies including four MIRACL use cases: 1) isolated grids, 2) microgrids, and 3) behind-the-meter, and 4) front-of-the-meter wind turbine deployments.

17 WIND ENERGY↗

Advanced Distributed Wind Turbine Controls Series: Part 2-Wind Energy in Isolated Grids – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In an isolated grid, wind turbines are typically deployed to provide energy to maximize energy production, reduce diesel-fuel consumption, reduce carbon emissions, and reduce costs for energy and fuel transportation. However, in addition to solely providing energy to the power system, wind turbines contain rotating masses and inverter-based controls that can enable various reliability and resilience services through advance controls. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) this paper demonstrates, through desktop simulations, advanced wind turbine controls that can be employed to support higher contributions of wind in isolated grids, and to demonstrate ways that wind can play a role in supporting stability of an isolated grid. This isolated grid used in these desktop simulations is comprised of a wind turbine (600 kW), solar PV (430 kW), battery energy storage system (1 MW/1MWh), a simulated diesel generator (2 MW) and various types of loads (critical, dynamic). We developed a model of the subsystems in MATLAB/Simulink and validated them with available data from real-world components on NREL's Flatirons Campus. These validated models are then configured for various case studies. We compare the output of the desktop simulation with a baseline case with the diesel generator. Active and reactive power control of the wind turbine can help improve frequency and voltage responses in the isolated grid, respectively. By utilizing a small integrated battery energy storage system in the DC-link of the wind turbine, we also demonstrate that wind turbines can help blackstart a critical load comparable to its rated power and support other renewables (e.g. solar PV) come online and pick up an additional load. This report illustrates some of these reliability and resilience services a wind turbine can provide in an isolated grid.

17 WIND ENERGY↗

A neighboring optimal feedback control scheme for systems using discontinuous control.

The calculation and implementation of the neighboring optimal feedback control law for multiinput, nonlinear dynamical systems, using discontinuous control, is discussed. An initialization procedure is described which removes the requirement that the neighboring initial state be in the neighborhood of the nominal initial state. This procedure is a bootstrap technique for determining the most appropriate control-law gain for the neighboring initial state. The mechanization of the neighboring control law described is closed loop in that the concept of time-to-go is utilized in the determination of the control-law gains appropriate for each neighboring state. The gains are chosen such that the time-to-go until the next predicted switch time or predicted final time is the same for both the neighboring and nominal trajectories. The procedure described is utilized to solve the minimum-time satellite attitude-acquisition problem.

Foerster, R. E.↗

Solid state controller three axes controller

The reported flight controller features a handle grip which is mounted on a longitudinally extending control element. The handle grip is pivotally mounted on the control element about a pitch axis which is perpendicular to the longitudinal axis through the control element. The pivotal mounting includes a resilient force mounting mechanism which centers the grip relative to the control element. Rotation of the handle grip produces a direct rotation of a transducer element in a transducer which provides an electrical indication of the rotative movement about three mutually perpendicular axes.

Bailey, C. L., Jr.↗

Simulator evaluation of display concepts for pilot monitoring and control of space shuttle approach and landing. Phase 2: Manual flight control

A study of the display requirements for final approach management of the space shuttle orbiter vehicle is presented. An experimental display concept, providing a more direct, pictorial representation of the vehicle's movement relative to the selected approach path and aiming points, was developed and assessed as an aid to manual flight path control. Both head-up, windshield projections and head-down, panel mounted presentations of the experimental display were evaluated in a series of simulated orbiter approach sequence. Data obtained indicate that the experimental display would enable orbiter pilots to exercise greater flexibility in implementing alternative final approach control strategies. Touchdown position and airspeed dispersion criteria were satisfied on 91 percent of the approach sequences, representing various profile and wind effect conditions. Flight path control and airspeed management satisfied operationally-relevant criteria for the two-segment, power-off orbiter approach and were consistently more accurate and less variable when the full set of experimental display elements was available to the pilot. Approach control tended to be more precise when the head-up display was used; however, the data also indicate that the head-down display would provide adequate support for the manual control task.

Gartner, W. B.↗

Model-reference attitude control and reaction control jet engine placement for space shuttle

Analytical studies on the theoretical aspects of thrust vector control of large space vehicles were conducted. A system for attitude control of the space shuttle vehicle was developed. Major accomplishments of the project are: (1) investigation of a model-reference adaptive control scheme for controlling the space shuttle attitude and (2) determination of optimum placement of reaction control jet engines on space shuttles.

Boland, J. S., III↗

Development of electrical feedback controlled heat pipes and the advanced thermal control flight experiment

The development and characteristics of electrical feedback controlled heat pipes (FCHP) are discussed. An analytical model was produced to describe the performance of the FCHP under steady state and transient conditions. An advanced thermal control flight experiment was designed to demonstrate the performance of the thermal control component in a space environment. The thermal control equipment was evaluated on the ATS-F satellite to provide performance data for the components and to act as a thermal control system which can be used to provide temperature stability of spacecraft components in future applications.

Bienert, W. B.↗