Search NASA⌕ Search

SEARCH · Search NASA

Results for “DATA READOUT SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Spectrally Dependent Radiometric Measurement Errors Due to Ccd Serial Pixel-to-Pixel Readout Interference in the Ocean Color Instrument of the NASA PACE Mission

The Ocean Color Instrument on NASA’s PACE mission is a 322 887 nm hyperspectral imager with 1 km x 1 km nadir spatial resolution and 5 nm spectral resolution utilizing charge-coupled devices (CCDs) operating in Time Delay Integration (TDI) mode where each TDI column represents a different wavelength in 0.625 nm increments. After TDI, the charge is moved into serial output pixels and read out. The spatial resolution requires an 8.5 MHz readout rate. This only allows 59 ns for the CCD reset and video to be asserted and settled before sampling. The response exhibits serial pixel-to-pixel readout interference due to the lack of full settling. Each serial pixel value has a dependence on the value of the preceding pixel value. This leads to a spectrally dependent radiometric measurement error of up to 0.3 %. We explain the operation of the detection system, the behavior of the interference, and show the resulting measurement error based on data from both ground testing and on-orbit characterization.

Remote Sensing↗

Spectrally Dependent Radiometric Measurement Errors Due to CCD Serial Pixel-to-Pixel Readout Interference in the Ocean Color Instrument of the NASA PACE Mission

The Ocean Color Instrument on NASA’s PACE mission is a 322 887 nm hyperspectral imager with 1 km x 1 km nadir spatial resolution and 5 nm spectral resolution utilizing charge-coupled devices (CCDs) operating in Time Delay Integration (TDI) mode where each TDI column represents a different wavelength in 0.625 nm increments. After TDI, the charge is moved into serial output pixels and read out. The spatial resolution requires an 8.5 MHz readout rate. This only allows 59 ns for the CCD reset and video to be asserted and settled before sampling. The response exhibits serial pixel-to-pixel readout interference due to the lack of full settling. Each serial pixel value has a dependence on the value of the preceding pixel value. This leads to a spectrally dependent radiometric measurement error of up to 0.3 %. We explain the operation of the detection system, the behavior of the interference, and show the resulting measurement error based on data from both ground testing and on-orbit characterization.

Remote Sensing↗

The GlueX Start Counter and Beam Asymmetry$\Sigma$ in Single $\pi^{0}$ Photoproduction

The GlueX experiment aims to study meson photoproduction while utilizing the coherent bremsstrahlung technique to produce a 9 GeV linearly polarized photon beam incident on a liquid H 2 target. A Start Counter detector was fabricated to properly identify the accelerator electron beam buckets and to provide accurate timing information. The Start Counter detector was designed to operate at photon intensities of up to 10 8 γ/s in the coherent peak and provides a timing resolution ~300 ps so as to provide successful identification of the electron beam buckets to within 99% accuracy. Furthermore, the Start Counter detector provides excellent solid angle coverage, ~ 90% of 4π hermeticity, and a high degree of segmentation for background rejection. It consists of a cylindrical array of 30 scintillators with pointed ends that bend towards the beam at the downstream end. Magnetic field insensitive silicon photomultiplier detectors were selected as the readout system. An initial measurement of the beam asymmetry Sigma in the exclusive reaction γ$\vec{p}$→ π 0 p, where π 0 → γ has been carried out utilizing the GlueX spectrometer during the Spring 2015 commissioning run. The tagged photon energies ranged from 2.5≤ Eγ ≤ 3.0 GeV in the coherent peak. These measurements were then compared to the world data set and show remarkable agreement with only two hours of physics production running.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nucleon structure studies: DVCS on polarised protons with the CLAS12 experiment, and development of Micromegas detectors for EIC

The quark and gluon structure of nucleons is crucial for understanding the origin of their mass and spin. This information is encoded in structure function such as Generalised Parton Distributions (GPDs), which provide a three-dimensional picture of the nucleon in terms of its constituents. Deeply Virtual Compton Scattering (DVCS) offers the most direct access to GPDs, but their extraction requires high-precision measurements of multiple observables over a wide kinematic range. In 2022 and 2023 the CLAS12 experiment at Jefferson Lab (JLab) collected data from polarised electron scattering on a longitudinally polarised proton target, enabling the first measurement of polarised DVCS asymmetries at JLab 12GeV kinematics. This thesis will present preliminary measurement of the beam, target and double spin DVCS asymmetries from the CLAS12 polarised proton target data. Nucleon structure studies will also constitute a major part of the physics program at the future Electron Ion Collider (EIC). The development of the first detector at the EIC is ongoing and it requires light Micro-Pattern Gaseous Detectors (MPGDs) for its tracking system. This thesis further reports initial tests of Micromegas MPGDs with a two-dimensional readout developed for EIC.

Polcher, Samy [Univ. Paris-Saclay, Gif-sur-Yvette ↗

Single photon detection with the multi-anode CLAS12 RICH detector

Recently, the first module of the hybrid-optics large-area CLAS12 RICH at JLab has been put into operation using for the first time the well known Hamamatsu H8500 MAPMT and the new single-photon dedicated H12700, for a total of about 400 MAPMTs and 25000 pixels. The photon detector must efficiently detect single photons in the visible and near-UV light region, provide a fast response for background rejection and pattern recognition, and have a spatial resolution of less than 1 cm over an area of ≈1 m 2 . Each front-end readout unit is composed of three electronic boards with specific tasks directly connected to groups of 2 or 3 sensors. The core of the readout is composed of MAROC3 and FPGA chips. The MAROC3 chip is able to discriminate the 64 signals from one MAPMT and to produce 64 corresponding binary outputs with 100% efficiency starting at a small fraction of the single-photon signal, while the FPGA chip provides 1 ns TDC capability with 8 μs maximum latency and acts as a DAQ controller. The system is created to be almost dead-time free at the foreseen 20 kHz CLAS12 trigger rate. The best working conditions for single-photon detection have been studied at laser stands, test beams, and with the JLab electron beam data. A report of the photon detector preparation, commissioning and operation is here discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation and performance of the CMS silicon strip tracker with proton-proton collisions at the CERN LHC

Salient aspects of the commissioning, calibration, and performance of the CMS silicon strip tracker are discussed, drawing on experience during operation with proton-proton collisions delivered by the CERN LHC. The data were obtained with a variety of luminosities. The operating temperature of the strip tracker was changed several times during this period and results are shown as a function of temperature in several cases. Details of the system performance are presented, including occupancy, signal-to-noise ratio, Lorentz angle, and single-hit spatial resolution. Saturation effects in the APV25 readout chip preamplifier observed during early Run 2 are presented, showing the effect on various observables and the subsequent remedy. Studies of radiation effects on the strip tracker are presented both for the optical readout links and the silicon sensors. The observed effects are compared to simulation, where available, and they generally agree well with expectations.

47 OTHER INSTRUMENTATION↗

Determining Optimal Running Conditions for TinyTPC Detector

Liquid argon time projection chambers, (LArTPCs), are particle detectors used to collect ionization charge information from particle trajectories, facilitating detailed particle track analysis. They are currently used as particle detectors in major physics projects such as the deep underground neutrino experiment (DUNE), to detect and study the nature of the elusive neutrino particle. TinyTPC is a small scale LArTPC featuring a pixelated readout system (LArPix) that we will use to study liquid argon doping. We expect this doping to enhance the resolution of LAr detectors, especially for low energy particles below 10 MeV which would expand the capabilities of currently running experiments. Housed within a cryostat filled with liquid argon, the TinyTPC will rely on a high and a low voltage system to collect data. In preparation for deployment we found and resolved issues in the HV and LV systems and we determined optimal running conditions in a test vessel. This presentation will go over the detector commissioning process that enabled data taking with the TinyTPC.

Gonzalez, Rebecca↗

Planetary investigation utilizing an imaging spectrometer system based upon charge injection technology

An intrinsic silicon charge injection device (CID) television sensor array has been used in conjunction with a CaMoO4 colinear tunable acousto optic filter, a 61 inch reflector, a sophisticated computer system, and a digital color TV scan converter/computer to produce near IR images of Saturn and Jupiter with 10A spectral resolution and approximately 3 inch spatial resolution. The CID camera has successfully obtained digitized 100 x 100 array images with 5 minutes of exposure time, and slow-scanned readout to a computer. Details of the equipment setup, innovations, problems, experience, data and final equipment performance limits are given.

Wattson, R. B.↗

Online and Offline Data Quality Monitoring for the Mu2e Calorimeter

This thesis presents the design, implementation, and validation of a calorimeter Data Quality Monitoring (DQM) toolchain for the Mu2e experiment at Fermilab. Mu2e searches for charged lepton flavor violation via coherent muon-to-electron conversion in the field of an aluminum nucleus, $\mu^- Al \rightarrow e^-Al$, a process whose observation would constitute clear evidence of physics beyond the Standard Model. Achieving target sensitivity requires stringent control of detector performance and data integrity during acquisition, as subtle issues in readout configuration, data formatting, or electronics behavior can compromise reconstruction and bias downstream analyzes. To address these challenges, this work develops a multi-layer DQM approach spanning both raw data validation and reconstructed digi-level diagnostics. At the low level, a fragment analysis component performs word- and bit-field decoding of calorimeter readout blocks, enabling sanity checks of the expected structure and producing detailed error and integrity statistics useful for commissioning and troubleshooting. At the digi level, the CaloDigiDQM analyzer is implemented within the art framework and transforms each CaloDigiCollection into a structured hierarchy of ROOT histograms designed for fast drill-down diagnostics. The module generates coherent monitoring views at global, disk, board, and channel granularity, including occupancy, waveform-derived features (baseline, RMS, peak amplitude and position), and left-right sensor consistency metrics. Detector-aware channel-to-electronics mapping is performed through the conditions system (CaloDAQMap), ensuring that diagnostics remain aligned with hardware identifiers used in operations. For end-to-end testing without reliance on live DAQ data, a synthetic CaloDigi producer is developed to generate realistic waveforms with controlled noise and pulse shapes. The resulting system supports both offline ROOT-file production and online operation, including optional histogram streaming through otsdaq via ots::HistoSender. This toolchain provides a practical and scalable foundation for calorimeter commissioning and stable data collection, enabling early detection of anomalies and reducing operational risk for Mu2e.

Vakulenko, Mark [Drew U.] (ORCID:0009000276197818)↗

Real Time implementation of Artificial Intelligence compression algorithm for High-Speed Streaming Readout signals

The new generation of high-energy physics experiments plans to acquire data in streaming mode. With this approach, it is possible to access the information of the whole detector (organized in time slices) for optimal and lossless triggering of data acquisitions. With this approach, data rates, especially in large detectors, are often very high, and the network is likely to be the bottleneck for the entire Streaming Read Out system. The aim of this work is to study the implementation of a lossy compression algorithm based on Artificial Intelligence: an Autoencoder. With Machine Learning it is possible to achieve a high compression ratio and fast inference time with only a small degradation of the signals, almost negligible for the specific application. This work explores different configurations of the Autoencoder and the implementation on different hardware. Different Autoencoder configurations are explored to find the best trade-off between compression ratio and reconstruction loss, both for signals and energy spectrum. Different hardware implementations are also explored to find the best platform to achieve real-time performance for the specific application.

Rossi, Fabio (ORCID:0009000385713885)↗

SU-E-J-207: Effect of Pulse Sequence Parameters On Geometric Distortions Induced by a Titanium Brachytherapy Applicator

Purpose: To investigate the effect of readout bandwidth and voxel size on the appearance of distortion artifacts caused by a titanium brachytherapy applicator. Methods: An acrylic phantom was constructed to rigidly hold a MR conditional, titanium Fletcher-Suit-Delclos-style applicator set (Varian Medical Systems) for imaging on CT (Philips Brilliance) and 1.5T MRI (Siemens Magnetom Aera). Several variants of MRI parameters were tried for 2D T2-weighted turbo spin echo imaging in comparison against the standard clinical protocol with the criteria to keep relative SNR loss less than 20% and imaging time as short as possible. Two 3D sequences were also used for comparison with similar parameters. The applicator tandem was segmented on axial CT images (0.4×0.4×1.5mm {sup 3} resolution) and the CT images were registered to the 3D MR images in Eclipse (Varian). The applicator volume was then overlaid on all MRI sets in 3D-Slicer and distances were measured from the tandem tip to the MRI artifact edge in right/left/superior and anterior/posterior/superior directions from coronal and sagittal 2D acquisitions, respectively, or 3D data reformats. Artifact regions were also manually contoured in coronal/sagittal orientations for area measurements. Results: As would be expected, reductions in voxel size and increases in readout bandwidth reduced artifact size (average max artifact length decreased by 0.95 mm and average max area decrease by 0.27 cm{sup 2}). Interestingly, bandwidth increases yielded reductions in area (0.19 cm{sup 2}) and in distance measurements (1 mm) even with voxel increases, as compared to a standard protocol. This could be useful when high performance protocols are not feasible due to long imaging times. Conclusion: We have characterized artifacts caused by cervical brachytherapy applicator across multiple sequence parameters at 1.5T. Future work will focus on finalizing an optimal protocol that balances artifact reduction with imaging time and then testing this new protocol in patients.

60 APPLIED LIFE SCIENCES↗

L1 track triggers for ATLAS in the HL-LHC

The HL-LHC, the planned high luminosity upgrade for the LHC, will increase the collision rate in the ATLAS detector approximately a factor of 5 beyond the luminosity for which the detectors were designed, while also increasing the number of pile-up collisions in each event by a similar factor. This means that the level-1 trigger must achieve a higher rejection factor in a more difficult environment. This presentation discusses the challenges that arise in this environment and strategies being considered by ATLAS to include information from the tracking systems in the level-1 decision. The main challenges involve reducing the data volume exported from the tracking system for which two options are under consideration: a region of interest based system and an intelligent sensor method which filters on hits likely to come from higher transverse momentum tracks.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Multi-Layer Phoswich Radioxenon Detection System (7th Qtr Report), Reporting Period 10/01/07 - 12/31/07

Description of activities conducted this report period: (1) Electronics Development--To improve the overall performance of the two-channel digital pulse processor (DPP2), the PCB has been redesigned and the new printed board is now under assembly. The system is enhanced with two new fast ADCs from Analog Devices (AD9230-250), each with a sampling rate of 250 MHz and a resolution of 12 bits. The data bus uses a high performance Low Voltage Differential Signaling (LVDS) standard. The offset and gain of each channel are separately controlled digitally by the GUI software. (2) GUI Software Development--A GUI is being developed using the Python programming language. All functions from the preceding MATLAB code have been re-implemented including basic waveform readout, pulse shape discrimination, and plotting of energy spectra. In addition, the GUI can be used to control sampling runs based on the number of pulses captured, either in real or live time. Calibration coefficients and pulse shape discrimination boundaries can be changed on the fly so that the detector may be characterized experimentally. Plots generated by the GUI can be exported as graphic data. At present, the software has only been tested using one channel, pending availability of the new DPP board (DPP2). However, the functions have been written to allow easy expansion to two channels. (3) Light Collection Modeling--The XEPHWICH design has been modeled to determine its light capture efficiency. Research in the 7th quarter includes additional simulations representing significant increase in data resolution, well over an order of magnitude greater than previous simulations. The final data set represents approximately 11 billion visible photons divided equally among 110 thousand data points. A laboratory experiment is being designed and executed to experimentally determine light capture efficiency as a function of position within the scintillators. (4) Radioxenon Fission Source--We have designed and constructed a fission chamber to be used for the collection of radioxenon gases following neutron bombardment of HEU in the Oregon State University TRIGA reactor. The aluminum housing and all vacuum fittings have been assembled, awaiting an HEU transfer from PNNL. Students have worked closely with PNNL and OSU Radiation Safety personnel to facilitate transfer of the HEU. The OSU TRIGA Reactor Operations Committee has approved the experiment. (5) Spectral (beta) Recognition--Spectral identification by a neural network developed in our laboratory was compared to that of solvers of a linear system of equations. Data indicate that our neural network is capable of identifying three beta emission sources ({sup 14}C, {sup 36}Cl, and {sup 99}Tc) simultaneously with reliability to within 3%.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

First Beam Test of UT Sensors with the SALT 3.0 Readout ASIC

This note presents the results of a beam test conducted at the Fermilab test beam facility in March 2019. The beam test represents the first such test of the UT readout ASIC, SALT 3.0, in a beam with production UT sensors. Two sensors were tested, one an unirradiated p-in-n sensor, and the second a n-in-p sensor irradiated to twice the maximum expected uence. The beam test demonstrates that the SALT 3.0 ASIC meets our specifications, and can be used for the production. Due to specific issues with the data acquisition system that will not be present in the system in LHCb, a higher threshold was used in the beam test, corresponding to about $6 \sigma$ on the noise. With this higher threshold, the signal-to-noise ratio (S/N) and efficiency are measured. For the unirradiated sensor, a S/N of about 12 is achieved, with a single-hit effciency of at least 99.5%. For the irradiated sensor, a S/N of about 11 is obtained, with a single-hit effciency of about 94%. In the final system in LHCb with a proper threshold of about $3-4 \sigma$ of the noise, we expect to achieve a single-hit effciency of at least 99.5%.

43 PARTICLE ACCELERATORS↗

Implementing machine learning methods on QICK hardware for qubit readout & control

Quantum readout and control is a fundamental aspect of quantum computing that requires accurate measurement of qubit states. Errors emerge in all stages, from initialization to readout, and identifying errors in post-processing necessitates resource-intensive statistical analysis. In our work, we use a lightweight fully-connected neural network (NN) to classify states of a transmon system with no prior processing. Our NN accelerator yields higher fidelities (92%) than the classical matched filter method (84%). By exploiting the natural parallelism of NNs and their placement near the source of data on field-programmable gate arrays (FPGAs), we can achieve ultra-low latency on the Quantum Instrumentation Control Kit (QICK). Integrating machine learning methods on QICK opens several pathways for efficient real-time processing of quantum circuits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of direct readout Si:Sb and Si:Ga infrared detector arrays for space-based astronomy

Preliminary test results from the evaluation of Si:Sb and Si:Ga 58 x 62-element infrared detector arrays are presented. These devices are being characterized under background conditions and readout rates representative of operation in orbiting, crogenically-cooled infrared observatories. The arrays are hybridized to silicon direct-readout multiplexers which allow random-access and nondestructive readout. Array performance optimization is being conducted with a flexible microcomputer-based drive and readoaut electronics system. Preliminary Si:Sb measurements indicate a sense node capacitance of 0.06 pF, peak (28-micron) responsivity above 3 A/W at 2V bias, read noise of 130 rms e(-), dark current approximately 10 e(-)/s, and a well capacity greater than 10 to the 5th e(-). The limited test data available on the performance of the Si:Ga array are also discussed.

Mckelvey, Mark E.↗

First Operation of TES Microcalorimeters in Space with the Micro-X Sounding Rocket

Micro-X is a sounding rocket-borne instrument that uses a microcalorimeter array to perform high-resolution X-ray spectroscopy. This instrument flew for the first time on July 22nd, 2018, from the White Sands Missile Range, USA. This flight marks the first successful operation of a transition-edge sensor array and its time-division multiplexing readout system in space. This launch was dedicated to the observation of the supernova remnant Cassiopeia A. A failure in the attitude control system prevented the rocket from pointing and led to no time on target. The onboard calibration source provided X-rays in flight, and it is used to compare detector performance during preflight integration, flight, and after the successful post-flight recovery. This calibration data demonstrate the capabilities of the detector in a space environment as well as its potential for future flight.

TES↗

Reducing the Read Noise of HAWAII-2RG Detector Systems with Improved Reference Sampling and Subtraction (IRS2)

IRS2 is a Wiener-optimal approach to using all of the reference information that Teledyne's HAWAII-2RG detector arrays provide. Using a new readout pattern, IRS2 regularly interleaves reference pixels with the normal pixels during readout. This differs from conventional clocking, in which the reference pixels are read out infrequently, and only in a few rows and columns around the outside edges of the detector array. During calibration, the data are processed in Fourier space, which is <;:lose to the noise's eigenspace. Using IRS2, we have reduced the read noise of the James Webb Space Telescope Near Infrared Spectrograph by 15% compared to conventional readout. We are attempting to achieve further gains by calibrating out recently recognized non-stationary noise that appears at the frame rate.

Rauscher, Bernard J.↗