Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIAMONDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Short-pulse excitation of microwave plasma for efficient diamond growth

To realize a variety of potential applications of diamonds, particularly in the area of power electronics, it is indispensable to improve their growth efficiency. Most conventional approaches have tried to achieve this simply by increasing the gas temperature; however, this makes it difficult to grow large diamond crystals. To improve the growth efficiency while lowering the gas temperature, we propose that using a pulse-modulated microwave plasma with a sub-millisecond pulse width can enhance the power efficiency of the growth rate of single-crystal diamonds. We found that using a sub-millisecond pulse-mode discharge could almost double the growth rate obtained using continuous mode discharge for a fixed average microwave power and gas pressure. A comparison between experimental observations of the optical emission spectra of the discharge and a numerical simulation of the gas temperature suggests that a decrease in the gas temperature was achieved, and highlights the importance of electron-dominated reactions for obtaining the enhancement of the growth rate. This result will have a large impact in the area of diamond growth because it enables diamond growth to be more power efficient at reduced temperatures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modulation calorimetry in diamond anvil cells. II. Joule-heating design and prototypes

Here, Part I shows that quantitative measurements of heat capacity are theoretically possible inside diamond anvil cells via high-frequency Joule heating (100 kHz–10 MHz), opening up the possibility of new methods to detect and characterize transformations at high-pressure such as the glass transitions, melting, magnetic orderings, and the onset of superconductivity. Here, we test the possibility outlined in Part I, using prototypes and detailed numerical models. First, a coupled electrical-thermal numerical model shows that specific heat of metals inside diamond cells can be measured directly using ~1 MHz frequency, with <10% accuracy. Second, we test physical models of high-pressure experiments, i.e., diamond-cell mock-ups. Metal foils of 2–6 μm-thickness are clamped between glass insulation inside diamond anvil cells. Fitting data from 10 Hz to ~30 kHz, we infer the specific heat capacities of Fe, Pt, and Ni with ±20%–30% accuracy. The electrical test equipment generates -80 dBc spurious harmonics, which overwhelm the thermally induced harmonics at higher frequencies, disallowing the high precision expected from numerical models. An alternative Joule-heating calorimetry experiment, on the other hand, does allow absolute measurements with < 10% accuracy, despite the -80 dBc spurious harmonics: the measurement of thermal effusivity, $ \sqrt{ρck}$ (ρ, c , and k being density, specific heat, and thermal conductivity), of the insulation surrounding a thin-film heater. Using a ~50 nm-thick Pt heater surrounded by glass and 10 Hz–300 kHz frequency, we measure thermal effusivity with ±6% accuracy inside the sample chamber of a diamond anvil cell.

42 ENGINEERING↗

Reflectance of rhenium as a function of pressure in a diamond anvil cell

We have measured the reflectance of rhenium in the visible region to pressures up to 100 GPa in a diamond anvil cell (DAC). By photographing the reflecting surface, we visually show that there are challenges to obtaining accurate values in a DAC for several reasons, including cupping of the diamonds and roughening of the surface with the increase in pressure. We propose some useful procedures, such as careful alignment of the incident light and using thin gaskets to minimize cupping of the diamonds as well as measurement in the central region of the diamond culet. We also show that knowledge of the reflectance of rhenium can overcome the problem of absorption of light by diamonds when studying the reflectance of materials at high pressure in a DAC.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Excess noise in high-current diamond diodes

We report the results of an investigation of low-frequency excess noise in high-current diamond diodes. It was found that the electronic excess noise of the diamond diodes is dominated by the 1/f and generation-recombination noise, which reveals itself as Lorentzian spectral features (f is the frequency). The generation-recombination bulges are characteristic of diamond diodes with lower turn-on voltages. The noise spectral density dependence on forward current, I, reveals three distinctive regions in all examined devices—it scales as I 2 at the low (I < 10 μA) and high (I > 10 mA) currents and, rather unusually, remains nearly constant at the intermediate current range. The characteristic trap time constants, extracted from the noise data, show a uniquely strong dependence on current. Interestingly, the performance of the diamond diodes improves with the increasing temperature. The obtained results are important for the development of noise spectroscopy-based approaches for device reliability assessment for high-power diamond electronics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of optical absorption in polycrystalline CVD diamond plates by the phase photothermal method at a wavelength of 10.6 {mu}m

A highly-efficient phase photothermal method is developed for quantitative measurements of the small optical absorption coefficient in thin plates made of highly transparent materials in which bulk losses significantly exceed surface losses. The bulk absorption coefficient at 10.6 {mu}m is estimated in polycrystalline diamond plates grown from the vapour phase (a CVD diamond). The results are compared with those for natural and synthetic diamond single crystals and with the concentrations of nitrogen and hydrogen impurities. The absorption coefficient of the best samples of the CVD diamond did not exceed 0.06 cm{sup -1}, which, taking into account the high thermal conductivity of the CVD diamond (1800-2200 W mK{sup -1} at room temperature), makes this material attractive for fabricating output windows of high-power CO{sub 2} lasers, especially for manufacturing large-size optics. (laser applications and other topics in quantum electronics)

36 MATERIALS SCIENCE↗

Deformation of a laser beam in the fabrication of graphite microstructures inside a volume of diamond

We report a theoretical and experimental study of the energy profile deformation along the laser beam axis during the fabrication of graphite microstructures inside a diamond crystal. The numerical simulation shows that the use of a focusing lens with a numerical aperture NA < 0.1 at a focusing depth of up to 2 mm makes it possible to avoid a noticeable change in the energy profile of the beam due to the spherical aberration that occurs in the case of refraction of the focused laser beam at the air – diamond interface. The calculation results are confirmed by experimental data on the distribution of the laser intensity along the beam axis in front of its focal plane, derived from observations of graphitisation wave propagation in diamond. The effect of radiation self-focusing on laser-induced graphitisation of diamond is analysed. It is shown that if the wavefront distortion due to self-focusing can be neglected at a minimum pulse energy required for the optical breakdown of diamond, then an increase in the beam distortion with increasing pulse energy has no effect on the graphitisation process. (interaction of laser radiation with matter)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhanced Optical Properties of Chemical Vapor Deposited Single Crystal Diamond by Low-Pressure/High-Temperature Annealing

Single crystal diamond produced by chemical vapor deposition (CVD) at very high growth rates (up to 150 em/h) has been successfully annealed without graphitization at temperatures up to 2200 C and pressures <300 torr. Crystals were annealed in a hydrogen environment by using microwave plasma techniques for periods of time ranging from a fraction of minute to a few hours. This low-pressure/high-temperature (LPHT) annealing enhances the optical properties of this high-growth rate CVD single crystal diamond. Significant decreases are observed in UV, visible, and infrared absorption and photoluminescence spectra. The decrease in optical absorption after the LPHT annealing arises from the changes in defect structure associated with hydrogen incorporation during CVD growth. There is a decrease in sharp line spectral features indicating a reduction in nitrogen-vacancy-hydrogen (NVH-) defects. These measurements indicate an increase in relative concentration of nitrogen-vacancy (NV) centers in nitrogen-containing LPHT-annealed diamond as compared with as-grown CVD material. The large overall changes in optical properties and the specific types of alterations in defect structure induced by this facile LPHT processing of high-growth rate single-crystal CVD diamond will be useful in the creation of diamond for a variety of scientific and technological applications.

36 MATERIALS SCIENCE↗

Charge Collection and Propagation in Diamond X-ray Detectors

Diamond is a unique material for x-ray energy conversion. Its high thermal conductivity and low coefficient of thermal expansion make it ideal for high heat load environments. High material strength and x-ray transmission also are potentially useful features for certain applications in x-ray science. However, its large bandgap, while offering insensitivity to visible light, makes charge trapping more likely (thermal detrapping less likely) than in silicon; energy conversion efficiency is also 3-4 times less even under the best conditions. Limitations to charge collection efficiency such as recombination and charge trapping have been investigated quantitatively using quasi-continuous tunable synchrotron radiation under flexible biasing schemes as well using detailed Monte Carlo simulations. In the case of charge collection efficiency, the magnitude of the applied field, initial particle energy, and probe depth are adjusted. The diffusion and drift of photo-generated charge clouds are explicitly considered for the specific scattering behavior of diamond. While recombination loss at the entrance window of diamond diodes is qualitatively similar to a treatment for an additional 'dead' carbon window layer, the observed field and photon energy dependence implies that the more sophisticated model is more correct quantitatively. In addition, charge propagation in diamond is unique in that photoconductive gain is possible. Effectively, charge trapping of one carrier leads to screening of the applied field. In order to avoid photoconductive gain, either blocking contacts or explicit detrapping is required. Initial investigations of photoconductive gain as a function of applied field, waveform and photon energy have provided insight into the performance of state of the art single crystal diamond. Simple models are proposed to assist in extrapolating the observed behavior towards useful detector devices.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dosimetric characterization of a synthetic single crystal diamond detector in clinical radiation therapy small photon beams

Purpose: To determine the potentialities of synthetic single crystal diamond Schottky diodes for accurate dose measurements in radiation therapy small photon beams. Methods: The dosimetric properties of a diamond-based detector were assessed by comparison with a reference microionization chamber. The diamond device was operated at zero bias voltage under irradiation with high-energy radiotherapic photon beams. The stability of the detector response and its dose and dose rate dependence were measured. Different square field sizes ranging from 1 Multiplication-Sign 1 cm{sup 2} to 10 Multiplication-Sign 10 cm{sup 2} were used during comparative dose distribution measurements by means of percentage depth dose curves (PDDs), lateral beam profiles, and output factors. The angular and temperature dependence of the diamond detector response were also studied. Results: The detector response shows a deviation from linearity of less than {+-}0.5% in the 0.01-7 Gy range and dose rate dependence below {+-}0.5% in the 1-6 Gy/min range. PDDs and output factors are in good agreement with those measured by the reference ionization chamber within 1%. No angular dependence is observed by rotating the detector along its axis, while {approx}3.5% maximum difference is measured by varying the radiation incidence angle in the polar direction. The temperature dependence was investigated as well and a {+-}0.2% variation of the detector response is found in the 18-40 Degree-Sign C range. Conclusions: The obtained results indicate the investigated synthetic diamond-based detector as a candidate for small field clinical radiation dosimetry in advanced radiation therapy techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-BRE-02: Characterization of a New Commercial Single Crystal Diamond Detector in Photon, Electron and Proton Beams

Purpose: Diamond detectors even with superior characteristics have become obsolete due to poor design, selection of crystal and cost. Recently, microDiamond using synthetic single crystal diamond detector (SCDD) is commercially available which is characterized in various radiation beams in this study. Methods: The characteristics of a commercial SCDD model 60019 (PTW) to a 6- and 15-MV photon beams, 6- and 20-MeV electron beams, and 208 MeV proton beams were investigated and compared to the pre-characterized detectors: TN31010 (0.125 cm{sup 3}) and TN30006 (pinpoint) ionization chambers (PTW), EDGE detector (Sun Nuclear Corp), and SFD Stereotactic Dosimetry Diode Detector (IBA). The depth-dose and profiles data were collected for various field sizes and depths. The dose linearity and dose rate dependency were also evaluated. To evaluate the effects of the preirradiation, the diamond detector which had not been irradiated on the day was set up in the water tank and the response to 100 MU was measured every 20 s. The temperature dependency was tested for the range of 4–60 °C. Angular dependency was evaluated in water phantom by rotating the SCDD. Results: For all radiation types and field sizes, the depth-dose data of the diamond chamber showed identical curve to those of ionization chambers. The profile of the diamond detector was very similar to those of the Edge and SFD detectors, although the 0.125 cm{sup 3} and pinpoint chambers showed averaging effects in the penumbrae region. The temperature dependency was within 0.7% in the range of 4–41°C. A dose of 900 cGy and 1200 cGy were needed to stabilize the chamber to the level within 0.5% and 0.2%, respectively. Conclusion: The type 60019 SCDD detector showed suitable characteristics for depth-dose and profile measurements for wide range of field sizes. However, at least 1000 cGy of pre-irradiation is needed for accurate measurements.

07 ISOTOPE AND RADIATION SOURCES↗

Analysis of synthetic diamond single crystals by X-ray topography and double-crystal diffractometry

Structural features of diamond single crystals synthesized under high pressure and homoepitaxial films grown by chemical vapor deposition (CVD) have been analyzed by double-crystal X-ray diffractometry and topography. The conditions of a diffraction analysis of diamond crystals using Ge monochromators have been optimized. The main structural defects (dislocations, stacking faults, growth striations, second-phase inclusions, etc.) formed during crystal growth have been revealed. The nitrogen concentration in high-pressure/high-temperature (HPHT) diamond substrates is estimated based on X-ray diffraction data. The formation of dislocation bundles at the film-substrate interface in the epitaxial structures has been revealed by plane-wave topography; these dislocations are likely due to the relaxation of elastic macroscopic stresses caused by the lattice mismatch between the substrate and film. The critical thicknesses of plastic relaxation onset in CVD diamond films are calculated. The experimental techniques for studying the real diamond structure in optimizing crystal-growth technology are proven to be highly efficient.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structures of diamond-like phases

The diamond-like phases containing carbon atoms with the same degree of hybridization, which is close to sp{sup 3}, are classified. It is found that twenty such phases can exist, and ten of them are described for the first time. Molecular mechanics and semi-empirical quantum-mechanical methods are used to calculate the geometrically optimized structures of diamond-like phase clusters and to determine their structural parameters and properties, such as the density, the bulk modulus, and the sublimation energy. The difference between the properties of the diamond-like phases and those of diamond is found to be determined by the difference between the structures of these phases and diamond.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Self-Organization of Detonation-Diamond Particles on a Substrate in Carbon Condensation from the Vapor–Gas Phase

Processes in which the island structure is ordered occur in composite carbon films produced by preliminary population of an amorphous substrate with a detonation-diamond system and subsequent condensation of carbon from the vapor–gas phase. These processes, observed already upon filling of the substrate with diamond-growth centers, are manifested in that there appears a structural periodicity of the islands. It was found that the condensation of carbon on the populated substrate is accompanied by the evolution of the island structure of primary growth centers. This consists in that a hexagonal packing of the islands is formed, with the size of these islands increasing by two orders of magnitude. All these structural features of how a composite diamond-carbon film is formed indicate that self-organization processes occur in the system of diamond islands when carbon atoms are condensed and interact with primary diamond crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diamond x-ray optics: Transparent, resilient, high-resolution, and wavefront preserving

Diamond features a unique combination of outstanding physical properties perfect for numerous x-ray optics applications, where traditional materials such as silicon fail to perform. In the last two decades, impressive progress has been achieved in synthesizing diamond with high crystalline perfection, in manufacturing efficient, resilient, high-resolution, wavefront-preserving diamond optical components, and in implementing them in cutting-edge x-ray instruments. Diamond optics are essential for tailoring x-rays to the most challenging needs of x-ray research. Furthermore, they are becoming vital for the generation of fully coherent hard x-rays by seeded x-ray free-electron lasers. In this article, we review progress in manufacturing flawless diamond crystal components and their applications in diverse x-ray optical devices, such as x-ray monochromators, beam splitters, high-reflectance backscattering mirrors, lenses, phase plates, diffraction gratings, bent-crystal spectrographs, and windows.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Smaller Footprint Drilling System for Deep and Hard Rock Environments; Feasibility of Ultra-High-Speed Diamond Drilling

The two phase program addresses long-term developments in deep well and hard rock drilling. TerraTek believes that significant improvements in drilling deep hard rock will be obtained by applying ultra-high rotational speeds (greater than 10,000 rpm). The work includes a feasibility of concept research effort aimed at development that will ultimately result in the ability to reliably drill 'faster and deeper' possibly with smaller, more mobile rigs. The principle focus is on demonstration testing of diamond bits rotating at speeds in excess of 10,000 rpm to achieve high rate of penetration (ROP) rock cutting with substantially lower inputs of energy and loads. The significance of the 'ultra-high rotary speed drilling system' is the ability to drill into rock at very low weights on bit and possibly lower energy levels. The drilling and coring industry today does not practice this technology. The highest rotary speed systems in oil field and mining drilling and coring today run less than 10,000 rpm - usually well below 5,000 rpm. This document provides the progress through two phases of the program entitled 'Smaller Footprint Drilling System for Deep and Hard Rock Environments: Feasibility of Ultra-High-Speed Diamond Drilling' for the period starting 30 June 2003 and concluding 31 March 2009. The accomplishments of Phases 1 and 2 are summarized as follows: (1) TerraTek reviewed applicable literature and documentation and convened a project kick-off meeting with Industry Advisors in attendance (see Black and Judzis); (2) TerraTek designed and planned Phase I bench scale experiments (See Black and Judzis). Improvements were made to the loading mechanism and the rotational speed monitoring instrumentation. New drill bit designs were developed to provided a more consistent product with consistent performance. A test matrix for the final core bit testing program was completed; (3) TerraTek concluded small-scale cutting performance tests; (4) Analysis of Phase 1 data indicated that there is decreased specific energy as the rotational speed increases; (5) Technology transfer, as part of Phase 1, was accomplished with technical presentations to the industry (see Judzis, Boucher, McCammon, and Black); (6) TerraTek prepared a design concept for the high speed drilling test stand, which was planned around the proposed high speed mud motor concept. Alternative drives for the test stand were explored; a high speed hydraulic motor concept was finally used; (7) The high speed system was modified to accommodate larger drill bits than originally planned; (8) Prototype mud turbine motors and the high speed test stand were used to drive the drill bits at high speed; (9) Three different rock types were used during the testing: Sierra White granite, Crab Orchard sandstone, and Colton sandstone. The drill bits used included diamond impregnated bits, a polycrystalline diamond compact (PDC) bit, a thermally stable PDC (TSP) bit, and a hybrid TSP and natural diamond bit; and (10) The drill bits were run at rotary speeds up to 5500 rpm and weight on bit (WOB) to 8000 lbf. During Phase 2, the ROP as measured in depth of cut per bit revolution generally increased with increased WOB. The performance was mixed with increased rotary speed, with the depth cut with the impregnated drill bit generally increasing and the TSP and hybrid TSP drill bits generally decreasing. The ROP in ft/hr generally increased with all bits with increased WOB and rotary speed. The mechanical specific energy generally improved (decreased) with increased WOB and was mixed with increased rotary speed.

02 PETROLEUM↗

Development of Innovative Accident Tolerant High Thermal Conductivity UO 2 -Diamond Composite Fuel Pellets

The University of Florida (UF) evaluated a composite fuel consisting of UO 2 powder mixed with diamond micro particles as a candidate as an accident-tolerant fuel (ATF). The research group had previous extensive experience researching with diamond micro particles as an addition to reactor coolant for improved plant thermal performance. The purpose of this research work was to utilize diamond micro particles to develop UO 2 -Diamond composite fuel pellets with significantly enhanced thermal properties, beyond that already being measured in the previous UF research projects of UO 2 – SiC and UO 2 – Carbon Nanotube fuel pins. UF is proving with the current research results that the addition of diamond micro particles to UO 2 may greatly enhanced the thermal conductivity of the UO 2 pellets producing an accident-tolerant fuel. The Beginning of life benefits have been proven and fuel samples are being irradiated in the ATR reactor to confirm that the thermal conductivity improvements are still present under irradiation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nitridation of atomically smooth (111) diamond surfaces using a low temperature Penning plasma discharge

Diamond is a material with a wide band gap that can host a variety of isolated paramagnetic defects, called “color centers”1. These color centers have attractive optical and magnetic properties suitable for quantum applications including quantum computing, nanophotonics and quantum sensing. The most common one is the negatively charged nitrogen vacancy (NV) color center. For quantum sensing, it is desirable to reduce the distance between the NV center and the analyte by using shallow color centers in order to increase sensitivity. In this context, the diamond surface termination is especially critical. The appropriate surface termination is required to stabilize the color centers and mitigate surface magnetic noise. The nitrogen termination of diamond has been postulated as highly desirable for the NV color center. The goal of this project is to take advantage of an electron beam-generated ExB low temperature plasma developed by the Princeton Collaborative Low Temperature Plasma Research Facility (PCRF) at the Princeton Plasma Physics Laboratory (PPPL) to nitridate the surface of (100) diamond single crystals with minimal surface damage. In this reactor, the use of a magnetized plasma enables gentle processing of materials sensitive to ion damage. This is in strong contrast to radiofrequency plasma processing reactors which are known to etch and sputter the surface. XPS measurements indicate the incorporation of nitrogen and oxygen atoms at the surface in similar amounts. XAS measurements confirm the nitridation and indicate that the nitrogen termination is different from the nitrogen termination obtained using radiofrequency plasma treatment4. The combination of these results indicates the formation of amid species at the (100) diamond surface that are promising for the stabilization of NV centers for quantum sensing.

36 MATERIALS SCIENCE↗

Secondary-electron emission from hydrogen-terminated diamond

Diamond amplifiers demonstrably are an electron source with the potential to support high-brightness, high-average-current emission into a vacuum. We recently developed a reliable hydrogenation procedure for the diamond amplifier. The systematic study of hydrogenation resulted in the reproducible fabrication of high gain diamond amplifier. Furthermore, we measured the emission probability of diamond amplifier as a function of the external field and modelled the process with resulting changes in the vacuum level due to the Schottky effect. We demonstrated that the decrease in the secondary electrons average emission gain was a function of the pulse width and related this to the trapping of electrons by the effective NEA surface. The findings from the model agree well with our experimental measurements. As an application of the model, the energy spread of secondary electrons inside the diamond was estimated from the measured emission.

43 PARTICLE ACCELERATORS↗