Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dark photon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Direct stimulation of the retina by the method of virtual-quanta for heavy cosmic-ray nuclei

The contribution to the frequency of visual sensations induced in the dark-adapted eye by the virtual photon field was calculated, this field is associated with the heavy nuclei that exist in space beyond the geomagnetic field. In order to determine the probability that the virtual photon field induces a light flash, only the portion of the virtual photon spectrum that corresponds to the known frequency dependence of the sensitivity of human rods to visible light was utilized. The results can be expressed as a curve of the mean frequency of light flashes induced by the absorption of at least R virtual photons versus the threshold number R. The contribution to the light flash frequency from the virtual photon field of heavy cosmic ray nuclei is smaller than that from Cerenkov photons. The flux and energy spectra of galactic cosmic ray nuclei helium to iron were used.

Mcnulty, P. J.↗

Proton Radiation Effects on HgCdTe Avalanche Photodiode Detectors

Space radiation damage and proton induced transient effects were evaluated on 4.4 μm cutoff HgCdTe avalanche photodiode (APD) arrays developed by Leonardo DRS. Device performances as a function of total dose up to 100 krad (Si) were measured with ~60 MeV protons on 3 types of APD samples: 4x4 pixel APD fanout arrays with and without connection to a read-out integrated circuit (ROIC), and a 2x8 pixel photon counting APD focal plane array (FPA). A gamma-ray test was also conducted to study ionization effects. Both APD arrays exhibited a small decrease in the quantum efficiency and a linear increase in the dark current with the proton fluence. The 2x8 pixel photon counting FPA also exhibited an increase in the dark count rate with proton dose. After the proton irradiation and an overnight room temperature warm-up, the APD dark currents at 80 K increased significantly in both types of APD arrays. All radiation damage to these HgCdTe APD arrays annealed out after baking them at >85 °C for several hours. Transient protons through the devices were found to cause large pulses at the detector output but recover within 1 μs.

Xiaoli Sun↗

Focusing Optics for Axion Detection: Simulating Sensing Enhancements of Photons in InfraBREAD

The Broadband Reflector Experiment for Axion Detection (BREAD) will search for axions, a promising particle candidate for dark matter, in the high mass range of [$10^{-3}$,1]eV. BREAD acts like a telescope for dark matter, using a parabolic reflector to direct axion-induced photons onto a precise focal spot. InfraBREAD is the experimental version designed to detect photons resulting from axions with infrared frequency using a 1mm × 1mm Superconducting Nanowire Singe Photon Detector (SNSPD). However, at this frequency scale two problems arise: 1) the focal spot becomes smeared across an area larger than the size of the SNSPD detector; 2) any millimeter-scale misalignment shifts in the SNSPD can greatly diminish photon signal. This study performed simulations of novel optical configurations of lenses and reflectors placed around the SNSPD to achieve a greater efficiency than the SNSPD alone through both of these effects. One optical setup was identified called the “Parabolo id to Winston Cone (PTW) Configuration,” which exploits the optics of parabolic reflectors to focus incoming photons from the larger area of the smeared focal spot onto the smaller 1mm 2 area of the detector. The PTW configuration demonstrated overall improvements in efficiency by around 10% through misalignment shifts, with a maximal improvement of 55% in one region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of Transition Edge Sensor Detectors Optimized for Single-Photon Spectroscopy in the Optical and Near-Infrared

The search for biosignatures in the atmospheres of exoplanets will be a key focus of future space telescopes that operate in the ultraviolet, visible, and near-infrared bands. Detection of biosignatures requires an instrument with moderate spectral resolving power ($R \sim 100$) and a large bandwidth ($\sim 400$ nm -- $\sim 1.8$ $\mu$m). Additionally, biosignature detection is a photon-starved science; instruments designed for these measurements would ideally combine high optical efficiency with quantum-limited photon detectors (i.e., detectors that exhibit zero dark current). In this work, we report on our efforts to develop energy resolving transition edge sensor (TES)-based detectors designed for biosignature detection. TESs operated as microcalorimeters are compelling detectors for this application. Unlike semiconductor detectors, TESs eliminate the need for dispersive optics and are truly single photon detectors -- fundamental TES noise yields uncertainty in the energies of detected photons, not in the number of detected photons. We introduce TESs designed for this application and discuss the path toward realizing a TES-based dispersionless spectrometer optimized for biosignature detection.

Instrumentation and Photography↗

Development of Transition Edge Sensor Detectors Optimized for Single-Photon Spectroscopy in the Optical and Near-Infrared

The search for biosignatures in the atmospheres of exoplanets will be a key focus of future space telescopes that operate in the ultraviolet, visible, and near-infrared bands. Detection of biosignatures requires an instrument with moderate spectral resolving power (R ~ 100) and a large bandwidth (~ 400 nm – ~ 1.8 µm). Additionally, biosignature detection is a photon-starved science; instruments designed for these measurements would ideally combine high optical efficiency with quantum-limited photon detectors (i.e., detectors that exhibit zero dark current). In this work, we report on our efforts to develop energy resolving transition edge sensor (TES)-based detectors designed for biosignature detection. TESs operated as microcalorimeters are compelling detectors for this application. Unlike semiconductor detectors, TESs eliminate the need for dispersive optics and are truly single photon detectors – fundamental TES noise yields uncertainty in the energies of detected photons, not in the number of detected photons. We introduce TESs designed for this application and discuss the path toward realizing a TES-based dispersionless spectrometer optimized for biosignature detection.

Instrumentation and Photography↗

Assessment of Near-Angle Scatter on Exo-Earth Coronagraphy

Near-Angle Scatter (NAS) of the host star’s light into the coronagraph dark hole may limit the ability of a potential Habitable Worlds Observatory (HWO) to detect and characterize an Earth-like planet around a Sun-like star. This paper summarizes a 5-year investigation of the impact of NAS on high-contrast coronagraphy. Science requirements were flowed down to a draft flux ratio noise ratio (FRN) error budget with allocations for NAS. The modeled sources of NAS include correlated (low and mid-spatial) surface structure, uncorrelated surface microroughness and coating structure, particulate contamination, micrometeoroid impacts and polarization leakage. The paper develops specifications for these sources of scattered light that meet their FRN error budget allocations, distinguishing between scatter that can and cannot be modulated. The development process utilizes an analytical expression that predicts scatter throughput into the dark hole based on BRDF/BSDF. Using this relationship, Photon Engineering performed a FRED® straylight analysis of the HWO EAC-1 (Exploratory Analytical Case #1) coronagraph to parametrically study predicted scattered light contrast in the dark hole. The model revealed that primary mirror microroughness or contamination is not a significant source of scattered light; the most critical surfaces are the smallest and those located closest to the coronagraph focal plane mask. The assessment found that uncorrelated microstructure, contamination, and micrometeoroid impacts require more investigation and potential significant sources of unmodulated scattered light, and highlights that slow thermal wavefront drift is an order of magnitude more impactful than fast mechanical jitter.

coronagraphy↗

Dark states of electrons in a quantum system with two pairs of sublattices

A quantum state of matter that is forbidden to interact with photons and is therefore undetectable by spectroscopic means is called a dark state. This basic concept can be applied to condensed matter where it suggests that a whole band of quantum states could be undetectable across a full Brillouin zone. Here we report the discovery of such condensed-matter dark states in palladium diselenide as a model system that has two pairs of sublattices in the primitive cell. By using angle-resolved photoemission spectroscopy, we find valence bands that are practically unobservable over the whole Brillouin zone at any photon energy, polarization and scattering plane. Our model shows that two pairs of sublattices located at half-translation positions and related by multiple glide-mirror symmetries make their relative quantum phases polarized into only four kinds, three of which become dark due to double destructive interference. This mechanism is generic to other systems with two pairs of sublattices, and we show how the phenomena observed in cuprates, lead halide perovskites and density wave systems can be resolved by the mechanism of dark states. Our results suggest that the sublattice degree of freedom, which has been overlooked so far, should be considered in the study of correlated phenomena and optoelectronic characteristics.

electronic properties and materials↗

Photon-counting detector arrays based on microchannel array plates

The recent development of the channel electron multiplier (CEM) and its miniaturization into the microchannel array plate (MCP) offers the possibility of fully combining the advantages of the photographic and photoelectric detection systems. The MCP has an image-intensifying capability and the potential of being developed to yield signal outputs superior to those of conventional photomultipliers. In particular, the MCP has a photon-counting capability with a negligible dark-count rate. Furthermore, the MCP can operate stably and efficiently at extreme-ultraviolet and soft X-ray wavelengths in a windowless configuration or can be integrated with a photo-cathode in a sealed tube for use at ultraviolet and visible wavelengths. The operation of one- and two-dimensional photon-counting detector arrays based on the MCP at extreme-ultraviolet wavelengths is described, and the design of sealed arrays for use at ultraviolet and visible wavelengths is briefly discussed.

Timothy, J. G.↗

Temperature-dependent characterization of large-area superconducting microwire array with single-photon sensitivity in the near-infrared

Superconducting nanowire single photon detectors (SNSPDs) are a leading detector technology for time-resolved single-photon counting from the ultraviolet to the near-infrared regime. The recent advancement in single-photon sensitivity in micrometer-scale superconducting wires opens up promising opportunities to develop large area SNSPDs with applications in low background dark matter detection experiments. Here, we present the first detailed temperature-dependent study of a 4-channel 1×1 mm 2 WSi superconducting microwire single photon detector (SMSPD) array, including the internal detection efficiency, dark count rate, and importantly the coincident dark counts across pixels. The detector shows saturated internal detection efficiency for photon wavelengths ranging from 635 nm to 1650 nm, time jitter of about 160 ps for 1060 nm photons, and a low dark count rate of about 10 -2 Hz. Additionally, the coincidences of dark count rate across pixels are studied for the first time in detail, where we observed an excess of correlated dark counts, which has important implications for low background dark matter experiments. The results presented is the first step towards characterizing and developing SMSPD array systems and associated background for low background dark matter detection experiments.

47 OTHER INSTRUMENTATION↗

FLArE up dark sectors with EM form factors at the LHC forward physics facility

Despite being mostly secluded, dark sector particles may feebly interact with photons via a small mass-dimension 4 millicharge, a mass-dimension 5 magnetic and electric dipole moment, or a mass-dimension 6 anapole moment and charge radius. If sufficiently light, the LHC may produce an intense and collimated beam of these particles in the far forward direction. We study the prospects of searching for such dark sector particles with electromagnetic form factors via their electron scattering signature in the Forward Liquid Argon Experiment (FLArE) at the Forward Physics Facility (FPF). We find that FLArE can provide new probes of sub-GeV dark particles with dipole moments and strong sensitivities for millicharged particles in the 100 MeV to 100 GeV region. This complements other search strategies using scintillation signatures or dark matter direct detection and allows for probing strongly interacting dark matter motivated by the EDGES anomaly. Along with the FORMOSA detector, this leads to a very versatile and leading experimental program in the search for millicharged particles in the FPF.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark matter from anomaly cancellation at the LHC

We discuss a class of theories that predict a fermionic dark matter candidate from gauge anomaly cancellation. As an explicit example, we study the predictions in theories where the global symmetry associated with baryon number is promoted to a local gauge symmetry. In this context, the symmetry-breaking scale has to be below the multi-TeV scale in order to be in agreement with the cosmological constraints on the dark matter relic density. The new physical “Cucuyo” Higgs boson in the theory has very interesting properties, decaying mainly into two photons in the low mass region, and mainly into dark matter in the intermediate mass region. We study the most important signatures at the Large Hadron Collider, evaluating the experimental bounds. We discuss the correlation between the dark matter relic density, direct detection, and collider constraints. We find that these theories are still viable and are susceptible to being probed in current, and future high-luminosity, running. Published by the American Physical Society 2024

Butterworth, Jon (ORCID:0000000259055394)↗

Near-Infrared Photon-Counting Camera for High-Sensitivity Observations

The dark current of a transferred-electron photocathode with an InGaAs absorber, responsive over the 0.9-to-1.7- micron range, must be reduced to an ultralow level suitable for low signal spectral astrophysical measurements by lowering the temperature of the sensor incorporating the cathode. However, photocathode quantum efficiency (QE) is known to reduce to zero at such low temperatures. Moreover, it has not been demonstrated that the target dark current can be reached at any temperature using existing photocathodes. Changes in the transferred-electron photocathode epistructure (with an In- GaAs absorber lattice-matched to InP and exhibiting responsivity over the 0.9- to-1.7- m range) and fabrication processes were developed and implemented that resulted in a demonstrated >13x reduction in dark current at -40 C while retaining >95% of the approximately equal to 25% saturated room-temperature QE. Further testing at lower temperature is needed to confirm a >25 C predicted reduction in cooling required to achieve an ultralow dark-current target suitable for faint spectral astronomical observations that are not otherwise possible. This reduction in dark current makes it possible to increase the integration time of the imaging sensor, thus enabling a much higher near-infrared (NIR) sensitivity than is possible with current technology. As a result, extremely faint phenomena and NIR signals emitted from distant celestial objects can be now observed and imaged (such as the dynamics of redshifting galaxies, and spectral measurements on extra-solar planets in search of water and bio-markers) that were not previously possible. In addition, the enhanced NIR sensitivity also directly benefits other NIR imaging applications, including drug and bomb detection, stand-off detection of improvised explosive devices (IED's), Raman spectroscopy and microscopy for life/physical science applications, and semiconductor product defect detection.

Jurkovic, Michael↗

Cosmological implications of photon-flux upper limits at ultrahigh energies in scenarios of Planckian-interacting massive particles for dark matter

Here using the data of the Pierre Auger Observatory, we report on a search for signatures that would be suggestive of super-heavy particles decaying in the Galactic halo. From the lack of signal, we present upper limits for different energy thresholds above ≳10 8 GeV on the secondary by-product fluxes expected from the decay of the particles. Assuming that the energy density of these super-heavy particles matches that of dark matter observed today, we translate the upper bounds on the particle fluxes into tight constraints on the couplings governing the decay process as a function of the particle mass. Instantons, which are nonperturbative solutions to Yang-Mills equations, can give rise to decay channels otherwise forbidden and transform stable particles into metastable ones. Assuming such instanton-induced decay processes, we derive a bound on the reduced coupling constant of gauge interactions in the dark sector: α X ≲ 0.09, for 10 9 ≲ M X /GeV < 10 19 . Conversely, we obtain that, for instance, a reduced coupling constant α X = 0.09 excludes masses M X ≳ 3 x 10 13 GeV . In the context of dark matter production from gravitational interactions alone during the reheating epoch, we derive constraints on the parameter space that involves, in addition to M X and α X , the Hubble rate at the end of inflation, the reheating efficiency, and the nonminimal coupling of the Higgs with curvature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First displaced vertex search for electroproduced dark-sector strongly interacting massive particles by the HPS experiment

The Heavy Photon Search experiment (HPS) is a fixed-target, electron beam experiment designed to search for 𝑒 + ⁢𝑒 − mass resonances and displaced decays using a forward acceptance spectrometer. This paper details the search for naturally long-lived “dark” vector mesons (𝑉 𝐷 ) arising from a dark sector of beyond-Standard-Model strongly interacting massive particles, characterized by a QCD-like 𝑆⁢𝑈⁢(3) 𝐷 symmetry and coupled to the Standard Model photon via a new 𝑈⁢(1) 𝐷 gauge interaction mediated by the “heavy photon,” or 𝐴′. The results are based on an integrated luminosity of 10 608 nb −1 collected during the 2016 HPS engineering run. The displaced vertex search for 𝑉 𝐷 → 𝑒 +⁢ 𝑒 − in the 𝑒 +⁢ 𝑒 − invariant mass range 39–179 MeV showed no statistically significant evidence for signal above the QED background.

extensions of gauge sector↗

Ultralight millicharged dark matter via misalignment

We explore the cosmology and phenomenology of millicharged and millicharge-like dark matter with masses from 1 eV to 10 keV and charges of 10 -18 to 10 -14 . Dark matter in this mass range cannot be thermally produced, but can arise from non-thermal mechanisms. We propose a concrete model employing a spontaneously broken approximate global symmetry, in which millicharged dark matter is produced via the misalignment mechanism. We show that this production mechanism is cosmologically consistent and compatible with the observed dark matter abundance. This model can be implemented using either fundamental scalars or hidden-sector quarks, and coupled either to the Standard Model photon or to a hidden photon. We then consider the phenomenology of light millicharged dark matter, regardless of its cosmological origin, and determine the parameter space consistent with existing experiments and observations. A significant part of the new parameter space we consider may be accessible in the near future through direct deflection experiments, measurements of the cosmic microwave background blackbody spectrum, and future constraints on plasma instabilities due to dark matter self-interaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An improved synthetic signal injection routine for the Haloscope At Yale Sensitive To Axion Cold dark matter (HAYSTAC)

Microwave cavity haloscopes are among the most sensitive direct detection experiments searching for dark matter axions via their coupling to photons. When the power of the expected microwave signal due to axion–photon conversion is on the order of 10 −24 W, having the ability to validate the detector response and analysis procedure by injecting realistic synthetic axion signals becomes helpful. Here, we present a method based on frequency hopping spread spectrum for synthesizing axion signals in a microwave cavity haloscope experiment. It allows us to generate a narrow and asymmetric shape in frequency space that mimics an axion’s spectral distribution, which is derived from a Maxwell–Boltzmann distribution. In addition, we show that the synthetic axion’s power can be calibrated with reference to the system noise. Further, compared to the synthetic axion injection in the Haloscope At Yale Sensitive to Axion Cold dark matter (HAYSTAC) Phase I, we demonstrated synthetic signal injection with a more realistic line shape and calibrated power.

47 OTHER INSTRUMENTATION↗

Searching for axionlike time-dependent cosmic birefringence with data from SPT-3G

Ultralight axionlike particles (ALPs) are compelling dark matter candidates because of their potential to resolve small-scale discrepancies between Λ CDM predictions and cosmological observations. Axion-photon coupling induces a polarization rotation in linearly polarized photons traveling through an ALP field; thus, as the local ALP dark matter field oscillates in time, distant static polarized sources will appear to oscillate with a frequency proportional to the ALP mass. We use observations of the cosmic microwave background from SPT-3G, the current receiver on the South Pole Telescope, to set upper limits on the value of the axion-photon coupling constant g φ γ over the approximate mass range 10 - 22 – 10 - 19 eV , corresponding to oscillation periods from 12 hours to 100 days. For periods between 1 and 100 days ( 4.7 × 10 - 22 eV ≤ m φ ≤ 4.7 × 10 - 20 eV ), where the limit is approximately constant, we set a median 95% C.L. upper limit on the amplitude of on-sky polarization rotation of 0.071 deg. Assuming that dark matter comprises a single ALP species with a local dark matter density of 0.3 GeV / cm 3 , this corresponds to g φ γ < 1.18 × 10 - 12 GeV - 1 × ( m φ 1.0 × 10 - 21 eV ) . These new limits represent an improvement over the previous strongest limits set using the same effect by a factor of ~ 3.8 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A SiPM-based optical readout system for the EIC dual-radiator RICH

Silicon photomultipliers (SiPM) are candidates selected as the potential photodetector technology for the dual-radiator Ring-Imaging Cherenkov (dRICH) detector at the future Electron-Ion Collider (EIC). SiPM are cheap devices, highly efficient and insensitive to the high magnetic field at the expected location of the sensors in the experiment. Here, on the other hand, SiPM are not radiation tolerant. Despite the integrated radiation level is expected to be moderate it should be tested whether single photon-counting capabilities and the increase in dark count rate can be kept under control to maintain the optimal dRICH detector performance across the years. The current status of the research for the EIC dRICH application and the first results on studies performed on a sample of commercial and prototype SiPM sensors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗