Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector Readout”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Rydberg-atom-based single-photon detection for haloscope axion searches

We propose a Rydberg-atom-based single-photon detector for signal readout in dark matter haloscope experiments between 40 μ eV and 200 μ eV (10 GHz and 50 GHz). At these frequencies, standard haloscope readout using linear amplifiers is limited by quantum measurement noise, which can be avoided by using a single-photon detector. Our single-photon detection scheme can offer scan rate enhancements up to a factor of 10 4 over traditional linear amplifier readout, and is compatible with many different haloscope cavities. We identify multiple haloscope designs that could use our Rydberg-atom-based single-photon detector to search for QCD axions with masses above 40 μ eV (10 GHz), currently a minimally explored parameter space. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enabling Large Focal Plane Arrays through Mosaic Hybridization

We have demonstrated the hybridization of large mosaics of far-infrared detectors, joining separately fabricated sub-units into a single unit on a single, large substrate. We produced a single detector mockup on a 100mm diameter wafer and four mockup readout quadrant chips from a separate 100mm wafer. The individually fabricated parts were hybridized using a Suss FC150 flip chip bonder to assemble the detector-readout stack. Once all of the hybridized readouts were in place, a single, large and thick silicon substrate was placed on the stack and attached with permanent epoxy to provide strength and a Coefficient of Thermal Expansion (CTE) match to the silicon components underneath. Wirebond pads on the readout chips connect circuits to warm readout electronics; and were used to validate the successful superconducting electrical interconnection of the mockup mosaic-hybridized detector. This demonstration is directly scalable to 150 mm diameter wafers, enabling pixel areas over ten times the area currently demonstrated.

Miller, Timothy M.↗

Background reduction of a spherical gaseous detector

The Spherical gaseous detector (or Spherical Proportional Counter, SPC) is a novel type of detector. It consists of a large spherical volume filled with gas, using a single detection readout channel. The detector allows 100 % detection efficiency. SEDINE is a low background version of SPC installed at the Laboratoire Souterrain de Modane (LSM) underground laboratory (4800 m.w.e) looking for rare events at very low energy threshold, below 100 eV. This work presents the details on the chemical cleaning to reduce internal {sup 210}Pb surface contamination on the copper vessel and the external radon reduction achieved via circulation of pure air inside anti-radon tent. It will be also show the radon measurement of pure gases (Ar, N, Ne, etc) which are used in the underground laboratory for the low background experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A flexible event reconstruction based on machine learning and likelihood principles

Event reconstruction is a central step in many particle physics experiments, turning detector observables into parameter estimates; for example estimating the energy of an interaction given the sensor readout of a detector. A corresponding likelihood function is often intractable, and approximations need to be constructed. Here, in our work, we first show how the full likelihood for a many-sensor detector can be broken apart into smaller terms, and secondly how we can train neural networks to approximate all terms solely based on forward simulation. Our technique results in a fast, flexible, and close-to-optimal surrogate model proportional to the likelihood and can be used in conjunction with standard inference techniques allowing for a consistent treatment of uncertainties. We illustrate our technique for parameter inference in neutrino telescopes based on maximum likelihood and Bayesian posterior sampling. Given its great flexibility, we also showcase our method for geometry optimization enabling to learn optimal detector designs. Lastly, we apply our method to realistic simulation of a ton-scale water-based liquid scintillator detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of readout electronics for the CMS ME0 muon detector

The Large Hadron Collider (LHC) in the High Luminosity (HL-LHC) era will be upgraded to deliver instantaneous luminosities up to 5 X 10 34 cm -2 s -1 , five times more than the original design value. In order to maintain performance of the Compact Muon Solenoid (CMS) Experiment under these conditions, ME0 is one of the new muon detectors to be added, along with GE1/1, GE2/1, RE3/1 and RE4/1. ME0 uses the triple Gas Electron Multiplier (GEM) technology and is designed to cover the far-forward region of 2.0 < |η| < 2.8. Further, the readout electronics for ME0 must be designed to deal with high data rates and be sufficiently radiation hard to operate very close to the beamline. The design and development status of the readout electronics for ME0 are presented, along with recent results from integration tests performed using the latest electronics prototypes with GEM chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Readout of Large Capacitance SiPMs by Weak Coupling to Charge Sensitive Amplifier

Large area and large capacitance silicon photomultiplier (SiPM) arrays are employed to collect scintillation light in noble liquid time projection chambers (TPC) such as DarkSide, nEXO, MEGII, protoDUNE and DUNE. Light readout using ASICs designed for operation in noble liquids is a solution for large meter-scale photon detectors. However, conventional readout requires a high voltage decoupling capacitor larger than SiPM capacitance (in the range of tens of nF) to achieve full charge transfer to the preamplifier. Here, we demonstrate a readout concept by weakly coupling (via a capacitor lower by an order of magnitude than SiPM capacitance) to a charge sensitive amplifier, LArASIC in this case, without any loss in the signal to noise ratio (S/N). The single-photoelectron detection, signal-to-noise ratio, timing resolution, and coincidence detection are experimentally characterized.

47 OTHER INSTRUMENTATION↗

Enabling Large Focal Plane Arrays Through Mosaic Hybridization

We have demonstrated advances in mosaic hybridization that will enable very large format far-infrared detectors. Specifically we have produced electrical detector models via mosaic hybridization yielding superconducting circuit paths by hybridizing separately fabricated sub-units onto a single detector unit. The detector model was made on a 100mm diameter wafer while four model readout quadrant chips were made from a separate 100mm wafer. The individually fabricated parts were hybridized using a flip-chip bonder to assemble the detector-readout stack. Once all of the hybridized readouts were in place, a single, large and thick silicon substrate was placed on the stack and attached with permanent epoxy to provide strength and a Coefficient of Thermal Expansion match to the silicon components underneath. Wirebond pads on the readout chips connect circuits to warm readout electronics; and were used to validate the successful superconducting electrical interconnection of the model mosaic-hybrid detector. This demonstration is directly scalable to 150 mm diameter wafers, enabling pixel areas over ten times the area currently available.

Miller, TImothy M.↗

Enabling Large Focal Plane Arrays Through Mosaic Hybridization

We have demonstrated advances in mosaic hybridization that will enable very large format far-infrared detectors. Specifically we have produced electrical detector models via mosaic hybridization yielding superconducting circuit paths by hybridizing separately fabricated sub-units onto a single detector unit. The detector model was made on a 100mm diameter wafer while four model readout quadrant chips were made from a separate 100mm wafer. The individually fabricated parts were hybridized using a flip-chip bonder to assemble the detector-readout stack. Once all of the hybridized readouts were in place, a single, large and thick silicon substrate was placed on the stack and attached with permanent epoxy to provide strength and a Coefficient of Thermal Expansion match to the silicon components underneath. Wirebond pads on the readout chips connect circuits to warm readout electronics; and were used to validate the successful superconducting electrical interconnection of the model mosaic-hybrid detector. This demonstration is directly scalable to 150 mm diameter wafers, enabling pixel areas over ten times the area currently available.

Miller, Timothy M.↗

Hybrid analog/digital, large format, photon counting detectors for astronomy

The development of a new microchannel plate photon-counting detector with an analog readout method based on a resistive anode is reported. This detector exhibits extremely high, stable electron gains of 10 to the 8th. At this gain, the spatial resolution is no longer primarily limited by the noise of the resistive anode, so that digital methods of readout, such as discrete conductors, lose their advantage. These detectors can be readily scaled to 40 mm and 70 mm formats to match plate scales of 2-m (and larger) telescopes. New, high speed digital electronics fully exploit the high spatial and time resolution made possible by gains of this level. Analysis of the theoretical performance of this detector shows that the major limitation to the spatial resolution is the proximity focus of the photocathode and the first microchannel plate. The detector has been mated to an echelle spectrograph developed.

Crocker, J.↗

Enabling Large Focal Plane Arrays Through Mosaic Hybridization

We have demonstrated advances in mosaic hybridization that will enable very large format far-infrared detectors. Specifically we have produced electrical detector models via mosaic hybridization yielding superconducting circuit patbs by hybridizing separately fabricated sub-units onto a single detector unit. The detector model was made on a 100mm diameter wafer while four model readout quadrant chips were made from a separate 100mm wafer. The individually fabric.ted parts were hybridized using a Suss FCI50 flip chip bonder to assemble the detector-readout stack. Once all of the hybridized readouts were in place, a single, large and thick silicon substrate was placed on the stack and attached with permanent epoxy to provide strength and a Coefficient of Thermal Expansion match to the silicon components underneath. Wirebond pads on the readout chips connect circuits to warm readout electronics; and were used to validate the successful superconducting electrical interconnection of the model mosaic-hybrid detector. This demonstration is directly scalable to 150 mm diameter wafers, enabling pixel areas over ten times the area currently available.

Miller, Timothy M.↗

OVERVIEW OF THE KEPLER SCIENCE PROCESSING PIPELINE

The Kepler Mission Science Operations Center (SOC) performs several critical functions including managing the {approx}156,000 target stars, associated target tables, science data compression tables and parameters, as well as processing the raw photometric data downlinked from the spacecraft each month. The raw data are first calibrated at the pixel level to correct for bias, smear induced by a shutterless readout, and other detector and electronic effects. A background sky flux is estimated from {approx}4500 pixels on each of the 84 CCD readout channels, and simple aperture photometry is performed on an optimal aperture for each star. Ancillary engineering data and diagnostic information extracted from the science data are used to remove systematic errors in the flux time series that are correlated with these data prior to searching for signatures of transiting planets with a wavelet-based, adaptive matched filter. Stars with signatures exceeding 7.1{sigma} are subjected to a suite of statistical tests including an examination of each star's centroid motion to reject false positives caused by background eclipsing binaries. Physical parameters for each planetary candidate are fitted to the transit signature, and signatures of additional transiting planets are sought in the residual light curve. The pipeline is operational, finding planetary signatures and providing robust eliminations of false positives.

79 ASTRONOMY AND ASTROPHYSICS↗

Readout Noise of Digital Frequency Multiplexed TES Detectors for CUPID

The superconducting transition-edge sensor (TES) detectors have been the standard in cosmic microwave background (CMB) experiments for almost two decades and are now being adapted for use in nuclear physics, such as neutrinoless double beta decay searches. In this article, we focus on a new high-bandwidth frequency multiplexed TES readout system developed for CUPID, a neutrinoless double beta decay experiment that will replace CUORE. In order to achieve the high energy resolution requirements for CUPID, the readout noise of the system must be kept to a minimum. Low TES operating resistance and long wiring between the readout SQUID and the warm electronics are needed for CUPID, prompting a careful consideration of the design parameters of this application of frequency multiplexing. In this work, we characterize the readout noise of the newly designed frequency multiplexed TES readout system for CUPID and construct a noise model to understand it. Here, we find that current sharing between the SQUID coil impedance and other branches of the circuit, as well as the long output wiring, worsen the readout noise of the system. To meet noise requirements, a SQUID with a low input inductance, high transimpedance, and/or low dynamic impedance is needed, and the wiring capacitance should be kept as small as possible. Alternatively, the option of adding a cryogenic low-noise amplifier at the output of the SQUID should be explored.

CUPID↗

Synchronization of the 14 kTon NO$\nu$A neutrino detector with the Fermilab NuMI beam

The NOνA experiment is a neutrino oscillation experiment designed to measure parameters related to the neutrino mixing matrix, mass hierarchy and CP violation. The experiment measures neutrino and anti-neutrino interactions from the NuMI beam line at Fermilab in a Near Detector and a Far Detector located 810 kilometers away. Making these measurements requires precise synchronization of 344,064 channels in the Far Detector to an absolute wall time with a channel to channel variation of less then 10 ns. The experiment must correlate the presence of the relatively narrow neutrino beam in the detector with data readout. This paper will discuss the performance of the NOνA timing system during the first few months of operation at the Far Detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A first look at AS-ROC: a Si-Ge integrated chip readout for fast timing

Abstract Advances in timing detector technology require new specialized readout electronics. Applications demand below 10 ps time of arrival resolution and low power for a low repetition rate. A possible path to achieve O(10 ps) time resolution is an integrated chip using Silicon Germanium (SiGe) technology. Using DoE SBIR funding, Anadyne, Inc., in collaboration with UC Santa Cruz, has developed a prototype SiGe front-end readout chip optimized for low power and timing resolution. Two versions of the chip were produced with performance in simulation: a more power version with 10 ps resolution at 5 fC with 1.1 mW/channel, and a less power version with 10 ps resolution at 8 fC with 0.6 mW/channel.The chip was produced at Tower Semiconductor with 350 nm technology. The ASIC from the prototype run shows good performance: a rise time of 0.7–1 ns and 25 mV per fC response with RMS noise <1 mV. Simulation and results from the prototype will be reported in this paper.

Instruments & Instrumentation↗

Prototype Performance of Novel Muon Telescope Detector at STAR.

Research on a large-area, cost-effective Muon Telescope Detector (MTD) has been carried out for RHIC and for next generation detectors at future QCD Lab. We utilize state-of-the-art multi-gap resistive plate chambers with large modules and long readout strips in detector design. The results from cosmic ray and beam test will be presented to address intrinsic timing and spatial resolution for a Long-MRPC. The prototype performance of a novel muon telescope detector at STAR will be reported, including muon identification capability, timing and spatial resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prototype performance of novel muon telescope detector at STAR

Research on a large-area, cost-effective Muon Telescope Detector has been carried out for RHIC and for next generation detectors at future QCD Lab. We utilize state-of-the-art multi-gap resistive plate chambers with large modules and long readout strips in detector design [l]. The results from cosmic ray and beam test will be presented to address intrinsic timing and spatial resolution for a Long-MRF'C. The prototype performance of a novel muon telescope detector at STAR will be reported, including muon identification capability, timing and spatial resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Commissioning of the CMS Forward Pixel Detector

The Compact Muon Solenoid (CMS) experiment is scheduled for physics data taking in summer 2009 after the commissioning of high energy proton-proton collisions at Large Hadron Collider (LHC). At the core of the CMS all-silicon tracker is the silicon pixel detector, comprising three barrel layers and two pixel disks in the forward and backward regions, accounting for a total of 66 million channels. The pixel detector will provide high-resolution, 3D tracking points, essential for pattern recognition and precise vertexing, while being embedded in a hostile radiation environment. The end disks of the pixel detector, known as the Forward Pixel detector, has been assembled and tested at Fermilab, USA. It has 18 million pixel cells with dimension 100 x 150 {micro}m{sup 2}. The complete forward pixel detector was shipped to CERN in December 2007, where it underwent extensive system tests for commissioning prior to the installation. The pixel system was put in its final place inside the CMS following the installation and bake out of the LHC beam pipe in July 2008. It has been integrated with other sub-detectors in the readout since September 2008 and participated in the cosmic data taking. This report covers the strategy and results from commissioning of CMS forward pixel detector at CERN.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gated truncated readout system

A gated truncated readout system for position sensitive or imaging detectors that improves resolution over traditional readout systems. The readout system includes two or more amplifiers that receive a multichannel output analog data from the detector. Analog gates control circuitry, included in the readout circuit, receives the signals from the amplifiers, determines a fractional value of the sum-integral of the signals, and enables analog gates operation around an area of interest, disabling all other channels where noise dominates the signal value and thereby improving interpolation accuracy of the signals centroid position and the detector resolution. Filtered signals are transmitted to a centroid interpolation signal processing device for computation of the centroid position. As a result disabling all channels where noise dominates the signal value, the gated truncated readout system provides better accuracy improved detector resolution.

Popov, Vladimir↗