Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Simulation of Charge Collection in Diamond Detectors Irradiated with Deuteron-Triton Neutron Sources

Diamond-based neutron spectrometers exhibit outstanding properties such as radiation hardness, low sensitivity to gamma rays, fast response and high-energy resolution. They represent a very promising application of diamonds for plasma diagnostics in fusion devices. The measured pulse height spectrum is obtained from the collection of helium and beryllium ions produced by the reactions on {sup 12}C. An original code is developed to simulate the production and the transport of charged particles inside the diamond detector. The ion transport methodology is based on the well-known TRIM code. The reactions of interest are triggered using the ENDF/B-VII.0 nuclear data for the neutron interactions on carbon. The model is implemented in the TALLYX subroutine of the MCNP5 and MCNPX codes. Measurements with diamond detectors in a {approx}14 MeV neutron field have been performed at the FNG (Rome, Italy) and IRMM (Geel, Belgium) facilities. The comparison of the experimental data with the simulations validates the proposed model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation tool for optical design of PET detector modules including scintillator material and sensor array

The appearance of single photon avalanche diodes (SPADs) in the field of PET detector modules made it necessary to apply more complex optical design methods to refine the performance of such assemblies. We developed a combined simulation tool that is capable to model complex detector structures including scintillation material, light guide, light collection optics and sensor, correctly taking into account the statistical behavior of emission of scintillation light and its absorbance in SPADs. As a validation we compared simulation results obtained by our software and another optical design program. Calculations were performed for a simple PET detector arrangement used for testing purposes. According to the results, deviation of center of gravity coordinates between the two simulations is 0.0195 mm, the average ratio of total counts 1.0052. We investigated the error resulting from finite sampling in wavelength space and we found that 20 nm pitch is sufficient for the simulation in case of the given spectral dependencies. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Energy Electromagnetic Particle Transportation on the GPU

We present massively parallel high energy electromagnetic particle transportation through a finely segmented detector on a Graphics Processing Unit (GPU). Simulating events of energetic particle decay in a general-purpose high energy physics (HEP) detector requires intensive computing resources, due to the complexity of the geometry as well as physics processes applied to particles copiously produced by primary collisions and secondary interactions. The recent advent of hardware architectures of many-core or accelerated processors provides the variety of concurrent programming models applicable not only for the high performance parallel computing, but also for the conventional computing intensive application such as the HEP detector simulation. The components of our prototype are a transportation process under a non-uniform magnetic field, geometry navigation with a set of solid shapes and materials, electromagnetic physics processes for electrons and photons, and an interface to a framework that dispatches bundles of tracks in a highly vectorized manner optimizing for spatial locality and throughput. Core algorithms and methods are excerpted from the Geant4 toolkit, and are modified and optimized for the GPU application. Program kernels written in C/C++ are designed to be compatible with CUDA and OpenCL and with the aim to be generic enough for easy porting to future programming models and hardware architectures. To improve throughput by overlapping data transfers with kernel execution, multiple CUDA streams are used. Issues with floating point accuracy, random numbers generation, data structure, kernel divergences and register spills are also considered. Performance evaluation for the relative speedup compared to the corresponding sequential execution on CPU is presented as well.

Canal, P.↗

TH-CD-201-02: A Monte Carlo Investigation of a Novel Detector Arrangement for the Energy Spectrum Measurement of a 6MV Linear Accelerator

Purpose: Direct measurement of the energy spectrum of a 6MV linear accelerator has not been successful due to the high fluence rate, high energy nature of these photon beams. Previous work used a Compton Scattering (CS) spectrometry setup with a shielded spectrometer for spectrum measurements. Despite substantial lead shielding, excessive pulse pile-up was seen. MCNP6 transport code was used to investigate the feasibility and effectiveness of performing measurements using a novel detector setup. Methods: Simulations were performed with a shielded high-purity germanium (HPGe) semiconductor detector placed in the accelerator vault’s maze, with a 2 cm diameter collimator through a 92 cm thick concrete wall. The detector was positioned 660 cm from a scattering rod (placed at isocenter) at an angle of 45° relative to the central axis. This setup was compared with the shielded detector positioned in the room, 200 cm from the scattering rod at the same CS angle. Simulations were used to determine fluence contributions from three sources: (1) CS photons traveling through the collimator aperture, the intended signal, (2) CS scatter photons penetrating the detector shield, and (3) room-scattered photons penetrating the detector shield. Variance reduction techniques including weight windows, DXTRAN spheres, forced collisions, and energy cutoffs were used. Results: Simulations showed that the number of pulses per starting particle from an F8 detector tally for the intended signal decreased by a factor of 10{sup 2} when moving the detector out of the vault. This reduction in signal was amplified for the unwanted scatter signal which decreased by up to a factor of 10{sup 9}. Conclusion: This work used MCNP6 to show that using a vault wall to shield unwanted scatter and increasing isocenter-to-detector distance reduces unwanted fluence to the detector. This study aimed to provide motivation for future experimental work using the proposed setup.

07 ISOTOPE AND RADIATION SOURCES↗

Simulation Validation for the DUNE Near Detector

DUNE will study neutrino oscillations as they are beamed from Fermilab in Batavia, Illinois, 1300 km away to Sanford Underground Research Facility in South Dakota. However, when preparing for an experiment of this scale, it is crucial that we run simulations to validate the geometry and overall design of the project. This poster is comprised of my work during a 2026 SULI internship at Fermilab, involving reading the simulated data and assessing its validity.

Vershaw, Andre [Unlisted, US, IL] (ORCID:000900084↗

Nuclear recoil scintillation linearity of a high pressure 4 He gas detector

We investigate scintillation linearity of a commercial high pressure 4 He gas detector using monoenergetic 2.8 MeV neutrons from a deuterium-deuterium fusion neutron generator. The scintillation response of the detector was measured for a range of recoil energies between 83 keV and 626 keV by tagging neutrons scattering into fixed angles with a far-side organic scintillator detector. Detailed Monte Carlo simulations were compared to experimental data to determine the linearity of the detector response by comparing the scaling of the energy deposits in the simulations to the detector output. In this analysis, a linear scintillation response corresponds to a consistent value for the scaling factor between simulated energy deposits and experimental data for several different scattering angles. Here we demonstrate that the detector can be used to detect fast neutron interactions down to 83 keV recoil energies and can be used to characterize low-energy neutron sources, one of its potential applications.

47 OTHER INSTRUMENTATION↗

SU-E-J-100: Reconstruction of Prompt Gamma Ray Three Dimensional SPECT Image From Boron Neutron Capture Therapy(BNCT)

Purpose: Purpose of paper is to confirm the feasibility of acquisition of three dimensional single photon emission computed tomography (SPECT) image from boron neutron capture therapy (BNCT) using Monte Carlo simulation. Methods: In case of simulation, the pixelated SPECT detector, collimator and phantom were simulated using Monte Carlo n particle extended (MCNPX) simulation tool. A thermal neutron source (<1 eV) was used to react with the boron uptake region (BUR) in the phantom. Each geometry had a spherical pattern, and three different BURs (A, B and C region, density: 2.08 g/cm3) were located in the middle of the brain phantom. The data from 128 projections for each sorting process were used to achieve image reconstruction. The ordered subset expectation maximization (OSEM) reconstruction algorithm was used to obtain a tomographic image with eight subsets and five iterations. The receiver operating characteristic (ROC) curve analysis was used to evaluate the geometric accuracy of reconstructed image. Results: The OSEM image was compared with the original phantom pattern image. The area under the curve (AUC) was calculated as the gross area under each ROC curve. The three calculated AUC values were 0.738 (A region), 0.623 (B region), and 0.817 (C region). The differences between length of centers of two boron regions and distance of maximum count points were 0.3 cm, 1.6 cm and 1.4 cm. Conclusion: The possibility of extracting a 3D BNCT SPECT image was confirmed using the Monte Carlo simulation and OSEM algorithm. The prospects for obtaining an actual BNCT SPECT image were estimated from the quality of the simulated image and the simulation conditions. When multiple tumor region should be treated using the BNCT, a reasonable model to determine how many useful images can be obtained from the SPECT could be provided to the BNCT facilities. This research was supported by the Leading Foreign Research Institute Recruitment Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, Information and Communication Technologies (ICT) and Future Planning (MSIP)(Grant No.200900420) and the Radiation Technology Research and Development program (Grant No.2013043498), Republic of Korea.

07 ISOTOPE AND RADIATION SOURCES↗

Impact of cross section uncertainties on NOvA oscillation analyses

The NOvA experiment is an off-axis long-baseline neutrino oscillation experiment measuring $\nu_{\mu}$ disappearance and $\nu_{e}$ appearance in a $\nu_{\mu}$ beam originating at Fermilab. Oscillations are observed in the far detector relative to measurements made in the near detector, with a full simulation of the beam line and detectors being used to perform extrapolation between them. The neutrino simulation uses the GENIE event generator, which contains implementations of numerous theoretical neutrino interaction models applied to a variety of nuclear targets. However, recent data, recent reanalysis of extant data, and continued development of theoretical models have brought to light deficiencies in the default GENIE cross section model, which informs the predicted spectra used to infer oscillation parameters. We explore how uncertainties in this model, together with modifications to GENIE version 2.12.2 based on external information and NOvA Near Detector (ND) data, affect NOvA's oscillation parameter inferences. We also discuss how these uncertainties can be mitigated by judicious analysis design, including usage of the ND data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Machine learning neutrino-nucleus cross sections

Neutrino-nucleus scattering cross sections are critical theoretical inputs for long-baseline neutrino oscillation experiments. However, robust modeling of these cross sections remains challenging. For a simple but physically motivated toy model of the DUNE experiment, we demonstrate that an accurate neural-network model of the cross section—leveraging only Standard-Model symmetries—can be learned from near-detector data. We perform a neutrino oscillation analysis with simulated far-detector events, finding that oscillation analysis results enabled by our data-driven cross-section model approach the theoretical limit achievable with perfect prior knowledge of the cross section. We further quantify the effects of flux shape and detector resolution uncertainties as well as systematics from cross-section mismodeling. This proof-of-principle study highlights the potential of future neutrino near-detector datasets and data-driven cross-section models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Machine Learning Neutrino-Nucleus Cross Sections

Neutrino-nucleus scattering cross sections are critical theoretical inputs for long-baseline neutrino oscillation experiments. However, robust modeling of these cross sections remains challenging. For a simple but physically motivated toy model of the DUNE experiment, we demonstrate that an accurate neural-network model of the cross section—leveraging only Standard-Model symmetries— can be learned from near-detector data. We perform a neutrino oscillation analysis with simulated far-detector events, finding that oscillation analysis results enabled by our data-driven cross-section model approach the theoretical limit achievable with perfect prior knowledge of the cross section. We further quantify the effects of flux shape and detector resolution uncertainties as well as systematics from cross-section mismodeling. This proof-of-principle study highlights the potential of future neutrino near-detector datasets and data-driven cross-section models.

Tame-Narvaez, Karla [Fermilab] (ORCID:000000022249↗

Simulation of gamma-ray spectra for a variety of user-specified detector designs

The gamma-ray spectrum simulation program BSIMUL was designed to allow the operator to follow the path of a gamma-ray through a detector, shield and collimator whose dimensions are entered by the operator. It can also be used to simulate spectra that would be generated by a detector. Several improvements have been made to the program within the last few months. The detector, shield and collimator dimensions can now be entered through an interactive menu whose options are discussed below. In addition, spectra containing more than one gamma-ray energy can now be generated with the menu - for isotopes listed in the program. Adding isotopes to the main routine is also quite easy. Subroutines have been added to enable the operator to specify the material and dimensions of a collimator. This report details the progress made in simulating gamma-ray spectra for a variety of user-specified detector designs. In addition, a short discussion of work done in the related areas of pulse shape analysis and the spectral analysis is included. The pulse shape analysis and spectral analysis work is being performed pursuant to the requirements of contract F-94-C-0006, for the Advanced Research Projects Agency and the U.S. Air Force.

Rester, A. C., Jr.↗

The BetaCage, an ultra-sensitive screener for surface contamination

Material screening for identifying low-energy electron emitters and alpha-decaying isotopes is now a prerequisite for rare-event searches (e.g., dark-matter direct detection and neutrinoless double-beta decay) for which surface radiocon-tamination has become an increasingly important background. The BetaCage, a gaseous neon time-projection chamber, is a proposed ultra-sensitive (and nondestructive) screener for alpha-and beta-emitting surface contaminants to which existing screening facilities are insufficiently sensitive. Sensitivity goals are 0.1 betas keV{sup −1} m{sup −2} day{sup −1} and 0.1 alphas m{sup −2} day{sup −1}, with the former limited by Compton scattering of photons in the screening samples and (thanks to tracking) the latter expected to be signal-limited; radioassays and simulations indicate backgrounds from detector materials and radon daughters should be subdominant. We report on details of the background simulations and detector design that provide the discrimination, shielding, and radiopurity necessary to reach our sensitivity goals for a chamber with a 95 × 95 cm{sup 2} sample area positioned below a 40 cm drift region and monitored by crisscrossed anode and cathode planes consisting of 151 wires each.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GEANT4 investigation of 40 K and 222 Rn interference effects on actinide detection sensitivities of CEMRC BEGe lung detectors

Internal dosimetry measurements of trans-uranic (TRU) radionuclides within the human body can be accomplished by γ-ray spectroscopy using high-purity germanium detectors. While measurements are typically conducted inside shielded chambers in order to minimize the background detector signal, the presence of radioactive 40 K within the body cannot be removed, which produces a high-energy γ ray at 1461 keV. The 40 K, in addition to airborne 222 Rn, contributes to the radiation field within the chamber that increases to the minimum detectable activity that can be achieved in practice. The objective of the present work is to estimate the contributions from 40 K internal to the human body and airborne 222 Rn to the background signal in a lung counter germanium detector array using GEANT4 simulations, with a focus on TRU isotope energy region (17–59 keV). The investigations consisted of three main simulations: 1. Simulating the γ-ray flux at the geometric center of the CEMRC counting chamber arising from a 25 nCi source of 40 K from (a) a point source, and (b) a source distributed throughout a BOMAB phantom. 2. Simulating the response of the CEMRC BEGe detectors arising from a 25 nCi source of 40 K from (a) a point source, and (b) a source distributed throughout a BOMAB phantom. 3. Simulating the response of the CEMRC BEGe detectors to the environmental background in the counting chamber, consisting of airborne 222 Rn (0–4 pCi/L) and 40 K (0–160 nCi) internal to the human body. The results are used to investigate the 40 K background contribution to a routine spectrum recorded by the lung detectors at the CEMRC Internal Dosimetry laboratory over a typical half hour counting interval used in the dosimetry of radiological workers. The minimum detectable activity was calculated for various 222 Rn and 40 K activities and compared to experimentally determined values. The contribution of cosmic rays was not included in this investigation.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Machine Learning Neutrino-Nucleus Cross Sections

Neutrino-nucleus scattering cross sections are critical theoretical inputs for long-baseline neutrino oscillation experiments. However, robust modeling of these cross sections remains challenging. For a simple but physically motivated toy model of the DUNE experiment, we demonstrate that an accurate neural-network model of the cross section -- leveraging Standard Model symmetries -- can be learned from near-detector data. We then perform a neutrino oscillation analysis with simulated far-detector events, finding that the modeled cross section achieves results consistent with what could be obtained if the true cross section were known exactly. This proof-of-principle study highlights the potential of future neutrino near-detector datasets and data-driven cross-section models.

Wagman, Michael L. [Fermilab] (ORCID:0000000176701↗

Monte Carlo simulation for the electron cascade due to gamma rays in semiconductor radiation detectors

A Monte Carlo code was developed for simulating the electron cascade in radiation detector materials. The electron differential scattering cross sections were derived from measured electron energy-loss and optical spectra, making the method applicable for a wide range of materials. The detector resolution in a simplified model system shows dependence on the bandgap, the plasmon strength and energy, and the valence band width. In principle, these parameters could be optimized to improve detector performance. The intrinsic energy resolution was calculated for three semiconductors: silicon (Si), gallium arsenide (GaAs), and zinc telluride (ZnTe). Setting the ionization thresholds for electrons and holes is identified as a critical issue, as this strongly affects both the average electron-hole pair energy w and the Fano factor F. Using an ionization threshold from impact ionization calculations as an effective bandgap yields pair energies that are well matched to measured values. Fano factors of 0.091 (Si), 0.100 (GaAs), and 0.075 (ZnTe) were calculated. The Fano factor calculated for silicon using this model was lower than some results from past simulations and experiments. This difference could be attributed to problems in simulating inter-band transitions and the scattering of low-energy electrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy response characterization of current-mode MeV Cherenkov aerogel detectors

Current-mode Cherenkov aerogel detectors have been used to measure time resolved spectra of MeV radiographic x-ray sources and have been considered to replace gas Cherenkov systems. The simulations of the Cherenkov response of aerogel detectors have uncertainties in how to model the complex structure of aerogels. Data from three sites—the Idaho electron beam, the Los Alamos Site electron beam and microtron sources at Los Alamos—have been used to calibrate the relative energy response of 15 aerogels, varying in density from 10 to 430 mg/cm 3 , from incident electrons with energies from 1 to 12 MeV. Detector simulations need to introduce density variation in the aerogels to match the collected data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of computed radiography with imaging plate detectors

Computed radiography (CR) using phosphor imaging plate detectors is taking an increasing place in Radiography Testing. CR uses similar equipment as conventional radiography except that the classical X-ray film is replaced by a numerical detector, called image plate (IP), which is made of a photostimulable layer and which is read by a scanning device through photostimulated luminescence. Such digital radiography has already demonstrated important benefits in terms of exposure time, decrease of source energies and thus reduction of radioprotection area besides being a solution without effluents. This paper presents a model for the simulation of radiography with image plate detectors in CIVA together with examples of validation of the model. The study consists in a cross comparison between experimental and simulation results obtained on a step wedge with a classical X-ray tube. Results are proposed in particular with wire Image quality Indicator (IQI) and duplex IQI.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Signal and background considerations for the MRSt on the National Ignition Facility (NIF)

A Magnetic Recoil Spectrometer (MRSt) has been conceptually designed for time-resolved measurements of the neutron spectrum at the National Ignition Facility. Using the MRSt, the goals are to measure the time-evolution of the spectrum with a time resolution of ∼20-ps and absolute accuracy better than 5%. To meet these goals, a detailed understanding and optimization of the signal and background characteristics are required. Through ion-optics, MCNP simulations, and detector-response calculations, it is demonstrated that the goals and a signal-to background >5–10 for the down-scattered neutron measurement are met if the background, consisting of ambient neutrons and gammas, at the MRSt is reduced 50–100 times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗