Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diagnostic Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Impact of lossy compression on diagnostic accuracy of radiographs for periapical lesions

OBJECTIVES: The purpose of this study was to evaluate the lossy Joint Photographic Experts Group compression for endodontic pretreatment digital radiographs. STUDY DESIGN: Fifty clinical charge-coupled device-based, digital radiographs depicting periapical areas were selected. Each image was compressed at 2, 4, 8, 16, 32, 48, and 64 compression ratios. One root per image was marked for examination. Images were randomized and viewed by four clinical observers under standardized viewing conditions. Each observer read the image set three times, with at least two weeks between each reading. Three pre-selected sites per image (mesial, distal, apical) were scored on a five-scale score confidence scale. A panel of three examiners scored the uncompressed images, with a consensus score for each site. The consensus score was used as the baseline for assessing the impact of lossy compression on the diagnostic values of images. The mean absolute error between consensus and observer scores was computed for each observer, site, and reading session. RESULTS: Balanced one-way analysis of variance for all observers indicated that for compression ratios 48 and 64, there was significant difference between mean absolute error of uncompressed and compressed images (P <.05). After converting the five-scale score to two-level diagnostic values, the diagnostic accuracy was strongly correlated (R (2) = 0.91) with the compression ratio. CONCLUSION: The results of this study suggest that high compression ratios can have a severe impact on the diagnostic quality of the digital radiographs for detection of periapical lesions.

NASA Discipline Space Human Factors↗

Study of Coronal Heating in Solar Active Regions Using Wide-Field Imaging Spectroscopy: Hinode EIS Slot Observations

Understanding the frequency of heating events that keep the coronal plasma at several million Kelvin above the photospheric temperature of~ 6000K, is one of the most important problems in solar astrophysics. Spectroscopic observations of the Sun in the extreme ultraviolet (EUV) indicate that the coronal plasma reaches temperatures from 1 to 5 MK in active regions. It is also established that temperature in active regions can vary strongly with time and, moreover, contain sub-regions that evolve and develop separately. Tracking the spatio-temporal evolution of temperature requires continuous observation of the entire active region via imaging and spectroscopy. Traditional slit imaging spectroscopy probes plasma heating in solar active regions through observations of diagnostic emission lines and the resulting data are spectrally pure. Here, imaging is performed through rastering process, which severely limits co-temporal observations and often can be slow to miss events that evolve at other portions of the active region. In contrast, wide-field imaging spectroscopy offer simultaneous coverage of a large field of view as well as obtain spectral information in the same direction. This data suffers from spatial-spectral confusion, and are called spectroheliograms. Using the state-of-the-art inversion techniques that are developed recently, now spectroheliogram data can be unfolded to yield spectrally pure maps of large fields over long duration of observations. We use wide slit data, usually referred as ‘slot’, from the EUV Imaging Spectrometer (EIS) onboard Hinode satellite, focusing on active region observations. Here, we present our study of coronal heating in an active region using a long duration Hinode EIS slot observation.

Active region heating↗

Proposed framework for applying squeezed light to multi-photon absorption plasma diagnostics

We propose a quantum-enhanced plasma diagnostic based on squeezed states of light. Squeezed light can exhibit super-Poissonian photon statistics, leading to enhanced multiphoton absorption cross-sections compared to classical light. This effect enables improved sensitivity for two-photon excitation of high-energy atomic transitions such as ground-state excitation, and results in increased absorbed power and fluorescence in a plasma. We consider two methods of generating squeezed states and evaluate their advantages and limitations in the context of plasma absorption diagnostics. By comparing with and extending previous theoretical work, we predict an enhancement of the absorption signal by up to seven orders of magnitude at low intensities (10 1 W/m 2 ), with diminishing enhancement persisting up to high intensities (10 10 W/m 2 ). These results suggest that squeezed-light sources offer a viable pathway toward quantum-enhanced plasma diagnostics.

imaging↗

The infrared imaging video bolometer at Wendelstein 7-X

The radiated power distribution is a crucial aspect of heat transport, heat load mitigation, and plasma exhaust performance. An imaging video bolometer camera has been installed to measure the plasma radiated power in the divertor region of the Wendelstein 7-X (W7-X) stellarator. This diagnostic offers a wide-angle (40° × 68°) sampling of the plasma volume in both the poloidal and toroidal directions. The field-of-view is covered with a large number (> 500) of bolometer channels, providing imaging capability. The diagnostic design is introduced here together with its data analysis procedure. A set of laboratory experiments is performed to assess the thermal properties of the gold absorber foil and their spatial uniformity. Following installation, a heat source originating from the inertially cooled front of the diagnostic is identified and filtered out. The discharge data indicate a satisfactory signal-to-noise ratio as well as spatiotemporal resolution. These represent the first toroidally resolved images of the line-integrated radiated power in the W7-X island divertor. The diagnostic was then upgraded with a thinner platinum absorber and adjusted mirrors. Early data from the most recent experimental campaign employing the upgraded design show a considerable improvement in the diagnostic performance with more bolometer channels (> 1400), extended coverage, and increased spatial resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Computer processing of radiographic images

In the past 20 years, a substantial amount of effort has been expended on the development of computer techniques for enhancement of X-ray images and for automated extraction of quantitative diagnostic information. The historical development of these methods is described. Illustrative examples are presented and factors influencing the relative success or failure of various techniques are discussed. Some examples of current research in radiographic image processing is described.

Selzer, R. H.↗

Neutron radiation hardness of aluminum gallium nitride UV LEDs at various wavelengths

Radiation hard diagnostics are critical to the success of nuclear fusion at National Ignition Facility, Z, ITER, and prolonged space explorations. We have first demonstrated the exceptional proton radiation hardness of initial GaN devices and qualified their space flight and deployment for missions such as the Laser Interferometer Space Antenna and International Space Station. We have further conducted neutron radiation hardness experiments at Los Alamos Neutron Science Center by opening a new high fluence beam station. During 2014–2016, we irradiated multiple Aluminum Gallium Nitride (AlGaN) LEDs with a maximum fluence of 2.4 × 1013 neutrons/cm2 in 3 years and generated 54 161 current–voltage (I–V) scan traces. Our data processing program analyzes each and all I–V traces. In addition, we retrieved local temperature records to analyze and remove temperature effects in the outdoor environment. The I–V curve families of AlGaN UV LEDs with emitting wavelengths of 265, 275, and 310 nm were compared. The I–V curves of 265 nm AlGaN UV LEDs have the smallest deviations from the average value, while the I–V curves for 310 nm AlGaN LEDs showed the largest deviations from the average value. We have reached another important recommendation for the optimal use of multiple AlGaN optoelectronic devices or imaging arrays for inertially confined fusion diagnostics: Shorter wavelength devices at 265 nm exhibit more consistent radiation hardness performance than the 310 nm devices. Higher aluminum content LEDs or AlxGa1–xN devices with higher mole fraction x for generating shorter wavelengths have better radiation hardness for fusion diagnostics.

Sun, K. -X. (ORCID:0000000224659235)↗

Survey of Machine Learning-Based Rotating Detonation Engine Diagnostics: Evaluation for Broad Application in Experimental Facilities

This work evaluates and compares various convolutional neural networks (CNNs) trained in previous NETL studies according to metrics effecting diagnostic feasibility, external applicability, and performance. Each CNN surveyed, including image classification, object detection, and time series classification, is used to develop total RDE diagnostics and evaluated alongside conventional techniques with respect to real-time capabilities. Real-time capable diagnostics are deployed and evaluated in the laboratory environment using an altered experimental setup, which is outlined herein for possible adaptations in external experimental facilities.

Johnson, Kristyn↗

Survey of Machine Learning-Based Rotating Detonation Engine Diagnostics: Evaluation for Broad Application in Experimental Facilities

This work evaluates and compares various convolutional neural networks (CNNs) trained in previous NETL studies according to metrics effecting diagnostic feasibility, external applicability, and performance. Each CNN surveyed, including image classification, object detection, and time series classification, is used to develop total RDE diagnostics and evaluated alongside conventional techniques with respect to real-time capabilities. Real-time capable diagnostics are deployed and evaluated in the laboratory environment using an altered experimental setup, which is outlined herein for possible adaptations in external experimental facilities.

Johnson, Kristyn↗

Synthesis and Characterization of Radio-Halogenated Talazoparib Analogues for Imaging and Radioligand Therapy

Abstract Talazoparib (TZ) is a potent poly(ADP-ribose) polymerase 1/2 (PARP1/2) inhibitor that uniquely traps PARP complexes at sites of single-strand DNA damage thereby offering opportunities for targeted radioligand therapy. Radiolabeled halogenated TZ derivatives were synthesized using boronic ester precursors to enable incorporation of diagnostic and therapeutic radionuclides: 18F for PET imaging, 77Br for Auger electron radiotherapy, and 211At for targeted alpha radiotherapy. Copper-mediated radio-halogenation afforded racemic 18F-TZ, 77Br-TZ, and 211At-TZ in sufficient radiochemical yields (4.3 ± 2.6%, n = 33; 29.0 ± 12.0%, n = 4; 3.6 ± 3.8%, n = 9, respectively), ∼99% radiochemical purity and proven stability under formulation conditions. Molecular dynamics simulations of halo-TZ derivatives predicted an inverse relationship between halogen size and PARP1 binding affinity. Indeed, cell uptake of radio-halogenated TZ analogues indicated selective uptake in a panel of cell types that correlated with PARP1 levels but was inversely related to the atomic radii of the halogen series. Despite modest specific activity and specific uptake, 77Br-TZ showed significant cytotoxicity. Further investigation of 18F-TZ with 77Br-TZ as a radiotheranostic pair will be facilitated by the synthetic schemes herein.

Muzzioli, Riccardo [The University of Texas MD And↗

Development and characterization of a laser-gated, high resolution x-ray radiography platform for high energy density experiments using toroidally bent crystals

Bent crystal x-ray imagers are a well-established diagnostic tool to study high energy density (HED) objects by acquiring two-dimensional x-ray radiographs. Often, studying these HED objects requires very high spatial resolution, which is limited by astigmatism when using spherically bent crystals. By using toroidal-shaped crystals instead, astigmatism can be reduced and the overall spatial resolution of the instrument improved. Here, the development and characterization of a laser-gated x-ray radiography platform at the National Ignition Facility using a toroidal crystal is presented. This includes measurements of the spatial and temporal profile, which is determined by the x-ray source. In conclusion, to properly validate the reduced astigmatism, a new multi-plane grid approach was implemented, which, for the first time, allows a depth of field measurement, alignment verification and x-ray source size estimate in a single shot, demonstrating the current platform’s capability to provide sub-10 μm resolution over a 0.9 mm depth of field with a temporal resolution of 110 ps.

Crystal optics↗

First measurement of the 10B(α,n)13N reaction in an inertial confinement fusion implosion at the National Ignition Facility: Initial steps toward the development of a radiochemistry mix diagnostic

We report the first measurement of the 10B(α,n)13N reaction in a polar-direct-drive exploding pusher (PDXP) at the National Ignition Facility (NIF). This work is motivated by the need to develop alternative mix diagnostics, radiochemistry being the focus here. The target is composed of a 65/35 at. % deuterium–tritium (DT) fill surrounded by a roughly 30 μm thick beryllium ablator. The inner portion of the beryllium ablator is doped with 10 at. % of 10B. Radiation-hydrodynamics calculations were performed in 1D to optimize both the remaining boron rho-R and the DT neutron yield. A charged-particle transport post-processor has been developed to study α-induced reactions on the ablator material. Results indicate a large 13N production from α-induced reactions on 10B, measurable by the radiochemical analysis of a gaseous samples system at the NIF. The PDXP target N201115-001 was successfully fielded on the NIF, and nitrogen from the 10B(α,n)13N reaction was measured. The 13N production yield, as well as the DT neutron yield, was, however, lower than expected. Some of the reduced yields can be explained by the oblate shape, but the ratios of the various radiochemical signals are not commensurate with expectations based on a simple reduction of the 1D results. Preliminary 2D radiation-hydrodynamics computations are consistent with the experimental measurements, and work is ongoing to extend the radiochemistry analysis into higher dimensions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis and mitigation of an oscillating background on hybrid complementary metal-oxide semiconductor (hCMOS) imaging sensors at the National Ignition Facility

Nanosecond-gated hybrid complementary metal-oxide semiconductor imaging sensors are a powerful tool for temporally gated and spatially resolved measurements in high energy density science, including inertial confinement fusion, and in laser diagnostics. However, a significant oscillating background excited by photocurrent has been observed in image sequences during testing and in experiments at the National Ignition Facility (NIF). Characterization measurements and simulation results are used to explain the oscillations as the convolution of the pixel-level sensor response with a sensor-wide RLC circuit ringing. Finally, data correction techniques are discussed for NIF diagnostics, and for diagnostics where these techniques cannot be used, a proof-of-principle image correction algorithm is presented.

42 ENGINEERING↗

Auroral Boundaries: Comparison Between UV Images, In Situ Precipitation, and Groundbased Optical Observations

The location of poleward and equatorward boundaries are used as diagnostics of substorm phase and energy storage in the magnetosphere. Boundaries are estimated from groundbased observations (all sky imagers, meridian scanning photometers, and magnetometers), from in situ particle observations, and from spacebased global auroral observations. Each observational technique has relative advantages. Based on recent studies, different observing techniques can give differing boundary locations. Understanding any differences in the boundaries from each observing technique is important when using the data as a diagnostic for the magnetosphere. In this study, FUV auroral images from the POLAR Ultraviolet Imager are used to estimate auroral boundaries. These boundaries are then compared with similar boundaries derived from DMSP in situ particle precipitation observations and from groundbased meridian scanning photometers. The goal is to see how well the boundaries from these three dissimilar observations correlate, to estimate dependences on instrumental capabilities, i.e. imager resolution, and to serve as a potential first step to derive an algorithm for finding oval boundaries from groundbased optical data.

Germany, G. A.↗

Multiscale Modeling Meets Machine Learning: What Can We Learn?

Machine learning is increasingly recognized as a promising technology in the biological, biomedical, and behavioral sciences. There can be no argument that this technique is incredibly successful in image recognition with immediate applications in diagnostics including electrophysiology, radiology, or pathology, where we have access to massive amounts of annotated data. However, machine learning often performs poorly in prognosis, especially when dealing with sparse data. This is a field where classical physics-based simulation seems to remain irreplaceable. In this review, we identify areas in the biomedical sciences where machine learning and multiscale modeling can mutually benefit from one another: Machine learning can integrate physics-based knowledge in the form of governing equations, boundary conditions, or constraints to manage ill-posted problems and robustly handle sparse and noisy data; multiscale modeling can integrate machine learn- ing to create surrogate models, identify system dynamics and parameters, analyze sensitivities, and quantify uncertainty to bridge the scales and understand the emergence of function. With a view towards applications in the life sciences, we discuss the state of the art of combining machine learning and multiscale modeling, identify applications and opportunities, raise open questions, and address potential challenges and limitations. We anticipate that it will stimulate discussion within the community of computational mechanics and reach out to other disciplines including mathematics, statistics, computer science, artificial intelligence, biomedicine, systems biology, and precision medicine to join forces towards creating robust and efficient models for biological systems.

machine learning, multiscale modeling, physics-bas↗

Laser-metal interaction dynamics during additive manufacturing resolved by detection of thermally-induced electron emission

In situ monitoring is required to improve the understanding and increase the reliability of additive manufacturing methods such as laser powder bed fusion (LPBF). Current diagnostic methods for LPBF capture optical images, X-ray radiographs, or measure the emission of thermal or acoustic signals from the component. Herein, a methodology based on the thermal emission of electrons - thermionic emission - from the metal surface during LPBF is proposed which can resolve laser-material interaction dynamics. The high sensitivity of thermionic emission to surface temperature and surface morphology is revealed to enable precise determination of the transition between conduction and keyhole mode melting regimes. Increases in thermionic emission are correlated to laser scanning conditions that give rise to pore formation and regions where surface defects are pronounced. The information presented here is a critical step in furthering our understanding and validation of laser-based metal additive manufacturing.

36 MATERIALS SCIENCE↗

Experimental evaluation of the vapor box divertor concept with an open vapor box module in Magnum-PSI

A promising approach to handle the intense plasma heat flux in the divertor region of a tokamak is the Vapor Box Divertor (VBD). Here plasma-lithium interaction creates a dense lithium vapor cloud which interacts with the incoming plasma, effectively shielding the tungsten surface beneath, therefore preventing overheating and sputtering of the tungsten and increasing the component’s lifetime. Two key steps must be addressed to validate this concept: investigating plasma-Li interactions and the transport mechanism of the latter in the presence of plasma. To explore this, a Vapor Box Module (VBM) has been designed for use with the linear plasma generator Magnum-PSI. The VBM consists of a series of three cylindrical boxes, with Li being evaporated at a controlled temperature in the central box (CB). Divertor-like plasma enters the VBM from an upstream aperture, interacts with the Li vapor cloud and exits through a downstream aperture ultimately impacting a target equipped with a calorimetry system. Optical diagnostics Thomson scattering, Filtered fast camera Imaging and optical emission spectroscopy provided information on plasma parameters in terms of electron density n e , temperature T e and plasma composition before and after this interaction. A significant reduction in plasma power was observed upon the establishment of lithium vaporization determined via cooling water calorimetry and embedded thermocouples at the downstream target. This resulted in a drop of the target temperature from ∼800 °C to ∼350 °C (57%) at the highest applied power (11.1 MW m −2 ) and CB temperature (∼700 °C). Lithium condensation at the side boxes of the VBM in combination with strong plasma momentum transfer effectively prevented upstream migration of lithium, while enhancing Li transport toward the target. The achievement of the two main goals of reducing plasma power and confining the Li in the VBM, are consistent with earlier published preliminary SOLPS-ITER simulations. This study shows that the presence of lithium in a VBD-like configuration can result in a strong reduction of power to the target surface, while at the same time the lithium vapor is effectively confined by the VBM, aided by the incoming plasma, preventing its escape from the VBM geometry. This represents a valuable step toward validating the feasibility of the VBD configuration in future fusion reactors.

Magnum-PSI↗

In situ chamber for studying battery failure using high-speed synchrotron radiography

The investigation of lithium-ion battery failures is a major challenge for personnel and equipment due to the associated hazards (thermal reaction, toxic gases and explosions). To perform such experiments safely, a battery abuse-test chamber has been developed and installed at the microtomography beamline ID19 of the European Synchrotron Radiation Facility (ESRF). The chamber provides the capability to robustly perform in situ abuse tests through the heat-resistant and gas-tight design for flexible battery geometries and configurations, including single-cell and multi-cell assemblies. High-speed X-ray imaging can be complemented by supplementary equipment, including additional probes (voltage, pressure and temperature) and thermal imaging. Together with the test chamber, a synchronization graphical user interface was developed, which allows an initial interpretation by time-synchronous visualization of the acquired data. Enabled by this setup, new meaningful insights can be gained into the internal processes of a thermal runaway of current and future energy-storage devices such as lithium-ion cells.

25 ENERGY STORAGE↗

CSEM, Bottomhole Pressure, Salinity, and Flow-Rate Data Collected in Sep. 2020 for Proj. DE-FE0031785

This dataset consists of two directories: first directory named as EM for the controlled source electromagnetic (CSEM) survey data that are zipped per day for September 22, 23, 24, 25, and 27, 2020, and second directory named as "Bottomhole Pressure, Salinity, and Flow-Rate" for the simultaneous collection of bottomhole pressure and salinity and pump flow rate during the CSEM surveys.

CSEM↗