Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Diamond Photodetectors for X-Ray Absorption Spectroscopy Applications

Synchrotron radiation (SR) is a fundamental tool for X-ray research. In particular, X-ray absorption spectroscopy (XAS) accesses information as electronic properties, local structure or chemical-physical state in condensed-matter studies. Ionization chambers (ICs) are the most widely used XAS detectors for transmission measurements because of their reliability, high linearity and good stability. Recently, solid-state detectors have been considered and Si p-i-n has been applied to high fluxes (10{sup 11} ph/s), where the linearity of ICs is no longer guaranteed. Silicon photodiodes exhibit an extremely linear response in at least 5 decades but show diffraction peaks. Diamond is an ideal substrate to produce radiation-hard, low dark current (<1 pA/cm{sup 2}), visible-blind and fast-response X-ray detectors with a high S/N ratio. Diamond detectors were tested as SR monitor capable to withstand the high photon flux density of the 3{sup rd} generation SR sources. Being the lowest X-ray-absorbing solid-state dielectric material, diamond maximizes the flux through thin self-standing devices with minimal spectral effect down to the soft x-ray range. We will present results of X-ray tests of photoconductors based on different diamond substrates. The results will be compared to standard ICs for XAS applications in terms of spectral quality, noise and linearity in the 4-13 keV energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The HPS electromagnetic calorimeter

The Heavy Photon Search experiment (HPS) is searching for a new gauge boson, the so-called "heavy photon". Through its kinetic mixing with the Standard Model photon, this particle could decay into an electron-positron pair. It would then be detectable as a narrow peak in the invariant mass spectrum of such pairs, or, depending on its lifetime, by a decay downstream of the production target. The HPS experiment is installed in Hall-B of Jefferson Lab. This article presents the design and performance of one of the two detectors of the experiment, the electromagnetic calorimeter, during the runs performed in 2015-2016. The calorimeter's main purpose is to provide a fast trigger and reduce the copious background from electromagnetic processes through matching with a tracking detector. Finally, the detector is a homogeneous calorimeter, made of 442 lead-tungsten (PbWO$_4$) scintillating crystals, each read-out by an avalanche photodiode coupled to a custom trans-impedance amplifier.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-to-electron magnetic spectrometer (GEMS): An energy-resolved {gamma}-ray diagnostic for the National Ignition Facility

The gamma-to-electron magnetic spectrometer, having better than 5% energy resolution, is proposed to resolve {gamma}-rays in the range of E{sub o}{+-} 20% in single shot, where E{sub o} is the central energy and is tunable from 2 to 25 MeV. Gamma-rays from inertial confinement fusion implosions interact with a thin Compton converter (e.g., beryllium) located at approximately 300 cm from the target chamber center (TCC). Scattered electrons out of the Compton converter enter an electromagnet placed outside the NIF chamber (approximately 600 cm from TCC) where energy selection takes place. The electromagnet provides tunable E{sub o} over a broad range in a compact manner. Energy resolved electrons are measured by an array of quartz Cherenkov converters coupled to photomultipliers. Given 100 detectable electrons in the energy bins of interest, 3 Multiplication-Sign 10{sup 14} minimum deuterium/tritium (DT) neutrons will be required to measure the 4.44 MeV {sup 12}C {gamma}-rays assuming 200 mg/cm{sup 2} plastic ablator areal density and 3 Multiplication-Sign 10{sup 15} minimum DT neutrons to measure the 16.75 MeV DT {gamma}-ray line.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarization effects in thallium bromide x-ray detectors

We present the results of a detailed experimental study of polarization effects in thallium bromide planar x-ray detectors. Measurements were carried out in the range 10-100 keV by scanning a highly focused x-ray beam, 50 {mu}m in diameter, from a synchrotron source across the detector. Above a certain radiation threshold the detector response showed a systematic degradation of its spectroscopic characteristics, peak channel position, peak height, and energy resolution. Using a pump-and-probe technique, we studied the dynamics of spectral degradation, the spatial extent and relaxation of the polarized region, and the dependence of the detector response on bias voltage and temperature. For comparison, we modeled polarization effects induced by the charging of traps by both electrons and holes using a model based on recent theoretical work of Bale and Szeles. We calculated the charge collection efficiency and spectral line shapes as functions of exposure time, beam position, count rate, and photon energy, and obtained credible agreement with experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing the diverse hydrogeology underlying rivers and estuaries using new floating transient electromagnetic methodology

We report the hydrogeology below large surface water features such as rivers and estuaries is universally under-informed at the long reach to basin scales (tens of km+). This challenge inhibits the accurate modeling of fresh/saline groundwater interfaces and groundwater/surface water exchange patterns at management-relevant spatial extents. Here we introduce a towed, floating transient electromagnetic (TEM) system (i.e. FloaTEM) for rapid (up to 15 km/h) high resolution electrical mapping of the subsurface below large water bodies to depths often a factor of 10 greater than other towed instruments. The novel FloaTEM system is demonstrated at a range of diverse 4th through 6th-order riverine settings across the United States including 1) the Farmington River, near Hartford, Connecticut; 2) the Upper Delaware River near Barryville, New York; 3) the Tallahatchie River near Shellmound, Mississippi; and, 4) the Eel River estuary, on Cape Cod, near Falmouth, Massachusetts. Airborne frequency-domain electromagnetic and land-based towed TEM data are also compared at the Tallahatchie River site, and streambed geologic scenarios are explored with forward modeling. A range of geologic structures and pore water salinity interfaces were identified. Process-based interpretation of the case study data indicated FloaTEM can resolve varied sediment-water interface materials, such as the accumulation of fines at the bottom of a reservoir and permeable sand/gravel riverbed sediments that focus groundwater discharge. Bedrock layers were mapped at several sites, and aquifer confining units were defined at comparable resolution to airborne methods. Terrestrial fresh groundwater discharge with flowpaths extending hundreds of meters from shore was also imaged below the Eel River estuary, improving on previous hydrogeological characterizations of that nutrient-rich coastal exchange zone. In summary, the novel FloaTEM system fills a critical gap in our ability to characterize the hydrogeology below surface water features and will support more accurate prediction of groundwater/surface water exchange dynamics and fresh-saline groundwater interfaces.

54 ENVIRONMENTAL SCIENCES↗

Development and calibration of a Thomson parabola with microchannel plate for the detection of laser-accelerated MeV ions

This article reports on the development and application of a Thomson parabola (TP) equipped with a (90x70) mm{sup 2} microchannel-plate (MCP) for the analysis of laser-accelerated ions, produced by a high-energy, high-intensity laser system. The MCP allows an online measurement of the produced ions in every single laser shot. An electromagnet instead of permanent magnets is used that allows the tuning of the magnetic field to adapt the field strength to the analyzed ion species and energy. We describe recent experiments at the 100 TW laser facility at the Laboratoire d'Utilization des Lasers Intenses (LULI) in Palaiseau, France, where we have observed multiple ion species and charge states with ions accelerated up to 5 MeV/u (O{sup +6}), emitted from the rear surface of a laser-irradiated 50 {mu}m Au foil. Within the experiment the TP was calibrated for protons and for the first time conversion efficiencies of MeV protons (2-13 MeV) to primary electrons (electrons immediately generated by an ion impact onto a surface) in the MCP are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wireless Monitoring Study in the Meuse / Haute-Marne Underground Research Laboratory, France - 12046

Two types of wireless transmission systems using ultra low frequency (8.5 kHz) were developed and used in the Callovo-Oxfordian argillites layer in the Meuse / Haute-Marne Underground Research Laboratory (CMHM URL) in France. Short-range and mid-range transmission antennas received data transmitted from 25 m to 50 m away. From the results of two series of tests, it is clear that transmission is practical when the received voltage is larger than the received noise. However, it is also clear that wireless transmission in the CMHM URL gallery is affected by the electromagnetic noise level and steel components, and the maximum transmission distance depends on the S/N ratio. The mid-range transmission antenna achieved a transmission distance of 240 m in the surface test, where the electromagnetic noise level was small and there was no environmental attenuation. The short-range transmission antenna achieved a transmission distance of 25 m in the surface test and in the CMHM URL gallery. As the clay layer of the CMHM URL had little effect on the attenuation of the electromagnetic field, transmission over 200 m might be possible in the CMHM URL when the electromagnetic noise level is small enough and there are no significant factors enhancing attenuation. But in reality, the possible transmission distance was around 50 m. In order to show the transmitter's ability, it is preferable to keep some distance between steel components and the transmitter. The most effective way to use this transmitter is to put it in a borehole drilled from a gallery to outside of a gallery around 10 m length. In this way, it might be possible to avoid almost of all the influence of steel components. For the position of receiver, the recommendation is the same as for the transmitter. That is, place the receiver where the incoming signal from the transmitter suffers little attenuation from steel components. Therefore, the option of implementing a receiving antenna in a borehole is required. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Highly Efficient Neutron Veto Using Boron-Loaded Liquid Scintillator

By surrounding a dark matter detector with a layer of boron-loaded liquid scintillator, a highly efficient neutron veto can be produced. In Monte Carlo studies, a one meter thick layer of scintillator has a veto efficiency greater than 99.5% for nuclear recoil events induced by radiogenic neutrons, and a veto efficiency of more than 95% for nuclear recoil events produced by cosmogenic neutrons. The use of boron-loaded scintillator both reduces the veto-induced dead time by decreasing the neutron capture time and allows high neutron detection efficiency to be achieved in a relatively compact geometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Picosecond timing of microwave Cherenkov impulses from high-energy particle showers using dielectric-loaded waveguides

Here, we report on the first measurements of coherent microwave impulses from high-energy particle-induced electromagnetic showers generated via the Askaryan effect in a dielectric-loaded waveguide. Bunches of 12.16 GeV electrons with total bunch energy of ∼10 3 – 10 4 GeV were preshowered in tungsten, and then measured with WR-51 rectangular (12.6 mm by 6.3 mm) waveguide elements loaded with solid alumina (Al 2⁢ O 3 ) bars. In the 5–8 GHz 𝑇⁢𝐸 10 single-mode band determined by the presence of the dielectric in the waveguide, we observed band-limited microwave impulses with amplitude proportional to bunch energy. Signals in different waveguide elements measuring the same shower were used to estimate relative time differences with 2.3 ps precision. These measurements establish a basis for using arrays of alumina-loaded waveguide elements, with exceptional radiation hardness, as very high precision timing planes for high-energy physics detectors.

43 PARTICLE ACCELERATORS↗

FPGA-based Upgrade to RITS-6 Control System, Designed with EMP Considerations

The existing control system for the RITS-6, a 20-MA 3-MV pulsed-power accelerator located at Sandia National Laboratories, was built as a system of analog switches because the operators needed to be close enough to the machine to hear pulsed-power breakdowns, yet the electromagnetic pulse (EMP) emitted would disable any processor-based solutions. The resulting system requires operators to activate and deactivate a series of 110-V relays manually in a complex order. The machine is sensitive to both the order of operation and the time taken between steps. A mistake in either case would cause a misfire and possible machine damage. Based on these constraints, a field-programmable gate array (FPGA) was chosen as the core of a proposed upgrade to the control system. An FPGA is a series of logic elements connected during programming. Based on their connections, the elements can mimic primitive logic elements, a process called synthesis. The circuit is static; all paths exist simultaneously and do not depend on a processor. This should make it less sensitive to EMP. By shielding it and using good electromagnetic interference-reduction practices, it should continue to operate well in the electrically noisy environment. The FPGA has two advantages over the existing system. In manual operation mode, the synthesized logic gates keep the operators in sequence. In addition, a clock signal and synthesized countdown circuit provides an automated sequence, with adjustable delays, for quickly executing the time-critical portions of charging and firing. The FPGA is modeled as a set of states, each state being a unique set of values for the output signals. The state is determined by the input signals, and in the automated segment by the value of the synthesized countdown timer, with the default mode placing the system in a safe configuration. Unlike a processor-based system, any system stimulus that results in an abort situation immediately executes a shutdown, with only a tens-of-nanoseconds delay to propagate across the FPGA. This paper discusses the design, installation, and testing of the proposed system upgrade, including failure statistics and modifications to the original design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A More Efficient, Radiation-Free Alternative to Systematic Chest X-Ray for the Detection of Embolized Seeds to the Lung

Purpose: To evaluate the efficacy of a seed-migration detector and to compare its performance to fluoroscopy and postoperative chest radiographs. Methods and Materials: A gamma scintillation survey meter was converted to a seed-migration detector by adding a shield on the probe detection window. The detector response to three {sup 125}I seed activities was characterized for different source-to-detector distances in water. The detector was used to perform a chest evaluation on 737 patients at their first postoperative visit. When the detector showed positive activity, seed migration was confirmed by taking a chest radiograph and by looking at the region with fluoroscopy. Results: One hundred and three patients (14.0%) presented at least one embolized seed. This accounts for 123 of the 39,887 seeds. Eighty-seven, 12, and 4 patients had respectively one, two, and three seed embolization. Compared with the seed-migration detector, detection based on fluoroscopy would have led to 13 false-negative detections (of 103, or 12.6%), and the radiograph would have resulted in 31 or 30.1%. More important, standard chest X-ray would have required a survey and extra radiation dose to lung to 100% of the patients, rather than the 14% who required it. Conclusions: The usual recommendation to perform chest radiographs at the first follow-up visit to scan lungs for embolized seeds should be revised because of the high false-negative rate. Scintillator-based gamma counter detector provides superior detection sensitivity and should be adopted as a standard of practice. Chest X-ray could be limited to documenting cases of positive migration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantum cascade laser investigations of CH{sub 4} and C{sub 2}H{sub 2} interconversion in hydrocarbon/H{sub 2} gas mixtures during microwave plasma enhanced chemical vapor deposition of diamond

CH{sub 4} and C{sub 2}H{sub 2} molecules (and their interconversion) in hydrocarbon/rare gas/H{sub 2} gas mixtures in a microwave reactor used for plasma enhanced diamond chemical vapor deposition (CVD) have been investigated by line-of-sight infrared absorption spectroscopy in the wavenumber range of 1276.5-1273.1 cm{sup -1} using a quantum cascade laser spectrometer. Parameters explored include process conditions [pressure, input power, source hydrocarbon, rare gas (Ar or Ne), input gas mixing ratio], height (z) above the substrate, and time (t) after addition of hydrocarbon to a pre-existing Ar/H{sub 2} plasma. The line integrated absorptions so obtained have been converted to species number densities by reference to the companion two-dimensional (r,z) modeling of the CVD reactor described in Mankelevich et al. [J. Appl. Phys. 104, 113304 (2008)]. The gas temperature distribution within the reactor ensures that the measured absorptions are dominated by CH{sub 4} and C{sub 2}H{sub 2} molecules in the cool periphery of the reactor. Nonetheless, the measurements prove to be of enormous value in testing, tensioning, and confirming the model predictions. Under standard process conditions, the study confirms that all hydrocarbon source gases investigated (methane, acetylene, ethane, propyne, propane, and butane) are converted into a mixture dominated by CH{sub 4} and C{sub 2}H{sub 2}. The interconversion between these two species is highly dependent on the local gas temperature and the H atom number density, and thus on position within the reactor. CH{sub 4}->C{sub 2}H{sub 2} conversion occurs most efficiently in an annular shell around the central plasma (characterized by 1400<T{sub gas}<2200 K), while the reverse transformation C{sub 2}H{sub 2}->CH{sub 4} is favored in the more distant regions where T{sub gas}<1400 K. Analysis of the multistep interconversion mechanism reveals substantial net consumption of H atoms accompanying the CH{sub 4}->C{sub 2}H{sub 2} conversion, whereas the reverse C{sub 2}H{sub 2}->CH{sub 4} process only requires H atoms to drive the reactions; H atoms are not consumed by the overall conversion.

36 MATERIALS SCIENCE↗

A Software Tool for Processing the Displacement Time Series Extracted from Raw Radar Data

The application of high-resolution radar waveform and interferometric principles recently led to the development of a microwave interferometer, suitable to simultaneously measuring the (static or dynamic) deflection of several points on a large structure. From the technical standpoint, the sensor is a Stepped Frequency Continuous Wave (SF-CW), coherent radar, operating in the K{sub u} frequency band.In the paper, the main procedures adopted to extract the deflection time series from raw radar data and to assess the quality of data are addressed, and the MATLAB toolbox developed is described. Subsequently, other functions implemented in the software tool (e.g. evaluation of the spectral matrix of the deflection time-histories, identification of natural frequencies and operational mode shapes evaluation) are described and the application to data recorded on full-scale bridges is exemplified.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Full-Automatic XAFS Measurement System of the Engineering Science Research II beamline BL14B2 at SPring-8

The Engineering Science Research II beamline BL14B2 at SPring-8 is a hard X-ray bending magnet beamline covering the wide energy range from 3.8 to 72 keV, and has been open to XAFS users since September 2007. The gas distribution and exhaust gas treatment systems have been installed for the in-situ XAFS measurements. Recent improvements in the speed of XAFS measurements have increased the demand for automated measurements. We have developed such a system, in which the adjustment of X-ray optics and the XAFS measurement in transmission mode can be performed automatically.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Speed X-ray Phase Imaging with Grating Interferometer and White Synchrotron Light

Taking advantage of the fact that an X-ray Talbot interferometer functions with X-rays of a broad energy band width, high-speed X-ray phase imaging and tomography have been achieved by using white synchrotron light. An X-ray phase tomogram could be measured with a 0.25 s exposure. Furthermore, a series of X-ray phase tomograms, in other words, a four-dimensional X-ray phase tomogram, could be reconstructed with a tomogram frame rate of 25.5 fps. This achievement advances X-ray phase imaging/tomography from a technique for static imaging to one for dynamic imaging of weakly absorbing objects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improvement in Stability of SPring-8 Standard X-Ray Monochromators with Water-Cooled Crystals

SPring-8 standard double-crystal monochromators containing water-cooled crystals were stabilized to a sufficient level to function as a part of optics components to supply stable microfocused x-ray beams, by determining causes of the instability and then removing them. The instability was caused by two factors--thermal deformation of fine stepper stages in the monochromator, which resulted in reduction in beam intensity with time, and vibrations of coolant supply units and vacuum pumps, which resulted in fluctuation in beam intensity. We remodeled the crystal holders to maintain the stage temperatures constant with water, attached x-ray and electron shields to the stages in order to prevent their warming up, introduced accumulators in the water circuits to absorb pressure pulsation, used polyurethane tubes to stabilize water flow, and placed rubber cushions under scroll vacuum pumps. As a result, the intensity reduction rate of the beam decreased from 26% to 1% per hour and the intensity fluctuation from 13% to 1%. The monochromators were also modified to prevent radiation damage to the crystals, materials used as a water seal, and motor cables.

43 PARTICLE ACCELERATORS↗