Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Wavelength Division Multiplexing Scheme for Radio-Frequency Single Electron Transistors

We describe work on a wavelength division multiplexing scheme for radio-frequency single electron transistors. We use a network of resonant impedance matching circuits to direct applied rf carrier waves to different transistors depending on carrier frequency. Using discrete components, we made a two-channel demonstration of this concept and successfully reconstructed input signals with small levels of cross coupling. A lithographic version of the rf circuits had measured parameters in agreement with electromagnetic modeling, with reduced cross capacitance and inductance, and should allow 20 to 50 channels to be multiplexed.

Stevenson, Thomas R.↗

Multiplexing of Radio-Frequency Single Electron Transistors

We present results on wavelength division multiplexing of radio-frequency single electron transistors. We use a network of resonant impedance matching circuits to direct applied rf carrier waves to different transistors depending on carrier frequency. A two-channel demonstration of this concept using discrete components successfully reconstructed input signals with small levels of cross coupling. A lithographic version of the rf circuits had measured parameters in agreement with electromagnetic modeling, with reduced cross capacitance and inductance, and should allow 20 to 50 channels to be multiplexed.

Stevenson, Thomas R.↗

Improved Position Sensor for Feedback Control of Levitation

An improved optoelectronic apparatus has been developed to provide the position feedback needed for controlling the levitation subsystem of a containerless-processing system. As explained, the advantage of this apparatus over prior optoelectronic apparatuses that have served this purpose stems from the use of an incandescent lamp, instead of a laser, to illuminate the levitated object. In containerless processing, a small object to be processed is levitated (e.g., by use of a microwave, low-frequency electromagnetic, electrostatic, or acoustic field) so that it is not in contact with the wall of the processing chamber or with any other solid object during processing. In the case of electrostatic or low-frequency electromagnetic levitation, real-time measurement of the displacement of the levitated object from its nominal levitation position along the vertical axis (and, in some cases, along one or two horizontal axes) is needed for feedback control of the levitating field.

Hyers, Robert↗

Electromagnetic Flow Meter Having a Driver Circuit Including a Current Transducer

An electromagnetic flow meter (EMFM) accurately measures both the complete flow rate and the dynamically fluctuating flow rate of a fluid by applying a unipolar DC voltage to excitation coils for a predetermined period of time, measuring the electric potential at a pair of electrodes, determining a complete flow rate and independently measuring the dynamic flow rate during the "on" cycle of the DC excitation, and correcting the measurements for errors resulting from galvanic drift and other effects on the electric potential. The EMFM can also correct for effects from the excitation circuit induced during operation of the EMFM.

Karon, David M.↗

Toward Muon Neutrino Charged-Current Neutral Pion Cross Section Measurements at ICARUS

At ICARUS and the broader Short-Baseline Neutrino Program, few neutrino interaction channels offer as much utility as those producing neutral pions, which are an important background to electron neutrino searches and provide a standard candle for calibrating the electromagnetic shower energy scale. Beyond this, measurements of neutrino-induced neutral pions offer a probe of resonant interactions that are relevant to future accelerator neutrino experiments like the Deep Underground Neutrino Experiment. In this document, a measurement of charged-current muon neutrino interactions in liquid argon with a single neutral pion in the final state is presented, making use of neutrino interaction events recorded with the ICARUS T600 detector at Fermilab while exposed to the Booster Neutrino Beam. Event selection is carried out with a fully-automated machine learning reconstruction framework, allowing for the extraction of single-differential cross section measurements as a function of muon and neutral pion kinematic observables.

Carber, Dan [Colorado State U.]↗

Non-contact temperature measurement

Three methods for noncontact temperature measurement are presented. Ideal gas thermometry is realized by using laser-induced fluorescence to measure the concentration of mercury atoms in a Hg-Ar mixture in the vicinity of hot specimens. Emission polarimetry is investigated by measuring the spatially resolved intensities of polarized light from a hot tungsten sphere. Laser polarimetry is used to measure the optical properties, emissivity, and, in combination with optical pyrometry, the temperature of electromagnetically levitated liquid aluminum. The precision of temperature measurements based on the ideal gas law is + or - 2.6 percent at 1500-2000 K. The polarized emission technique is found to have the capability to determine optical properties and/or spectral emissivities of specimens over a wide range of wavelengths with quite simple instruments.

Nordine, Paul C.↗

Collection of in situ forest canopy spectra using a helicopter - A discussion of methodology and preliminary results

An important part of fundamental remote sensing research is based on the measurement and analysis of spectral reflectance from earth surface materials in situ. It has been found that for an effective analysis of the target of interest, different applications of remotely sensed data require spectral measurements from different portions of the electromagnetic spectrum. It is pointed out that the detailed spectral reflectance characteristics of forest vegetation are currently not well understood, particularly in the middle infrared wavelength region. Details regarding the need for in situ forest canopy measurements are examined, taking into account certain difficulties arising in the case of satellite observations. Because of these difficulties, the present paper provides a discussion of methodology and preliminary spectra based on an experiment to use a helicopter as an observing platform for in situ forest canopy spectra measurement.

Williams, D. L.↗

Performance Evaluation of the SPT-140

As part of an on-going cooperative program with industry, an engineering model SPT-140 Hall thruster, which may be suitable for orbit insertion and station-keeping of geosynchronous communication satellites, was evaluated with respect to thrust and radiated electromagnetic interference at the NASA Lewis Research Center. Performance measurements were made using a laboratory model propellant feed system and commercial power supplies. The engine was operated in a space simulation chamber capable of providing background pressures of 4 x 10(exp -6) Torr or less during thruster operation. Thrust was measured at input powers ranging from 1.5 to 5 kilowatts with two different output filter configurations. The broadband electromagnetic emission spectra generated by the engine was also measured for a range of frequencies from 0.01 to 18,000 Mhz. These results are compared to the noise threshold of the measurement system and MIL-STD-461C where appropriate.

Manzella, David↗

Five degree-of-freedom control of an ultra-precision magnetically-suspended linear bearing

The authors constructed a high precision linear bearing. A 10.7 kg platen measuring 125 mm by 125 mm by 350 mm is suspended and controlled in five degrees of freedom by seven electromagnets. The position of the platen is measured by five capacitive probes which have nanometer resolution. The suspension acts as a linear bearing, allowing linear travel of 50 mm in the sixth degree of freedom. In the laboratory, this bearing system has demonstrated position stability of 5 nm peak-to-peak. This is believed to be the highest position stability yet demonstrated in a magnetic suspension system. Performance at this level confirms that magnetic suspensions can address motion control requirements at the nanometer level. The experimental effort associated with this linear bearing system is described. Major topics are the development of models for the suspension, implementation of control algorithms, and measurement of the actual bearing performance. Suggestions for the future improvement of the bearing system are given.

Trumper, David L.↗

Spectral emissivities and optical constants of electromagnetically levitated liquid metals as functions of temperature and wavelength

The development of a noncontact temperature measurement device utilizing rotating analyzer ellipsometry is described. The technique circumvents the necessity of spectral emissivity estimation by direct measurement concomittant with radiance brightness. Using this approach, the optical properties of electromagnetically levitated liquid metals Cu, Ag, Au, Ni, Pd, Pt, and Zr were measured in situ at four wavelengths and up to 600 K superheat in the liquid. The data suggest an increase in the emissivity of the liquid compared with the incandescent solid. The data also show moderate temperature dependence of the spectral emissivity. A few measurements of the optical properties of undercooled liquid metals were also conducted. The data for both solids and liquids show excellent agreement with available values in the literature for the spectral emissivities as well as the optical constants.

Krishnan, S.↗

Semiannual Status Report

During the last six months, we have continued our study of the excitation of electromagnetic waves in the whistler frequency range and the role that these waves will play in the acceleration of electrons and ions in the auroral region. A paper entitled 'Electron Beam Excitation of Upstream Waves in the Whistler Mode Frequency Range' was listed in the Journal of Geophysical Research. In this paper, we have shown that an anisotropic electron beam (or gyrating electron beam) is capable of generating both left-hand and right-hand polarized electromagnetic waves in the whistler frequency range. Since right-hand polarized electromagnetic waves can interact with background electrons and left-hand polarized waves can interact with background ions through cyclotron resonance, it is possible that these beam generated left-hand and right-hand polarized electromagnetic waves can accelerate either ions or electrons (or both), depending on the physical parameters under consideration. We are currently carrying out a comprehensive study of the electromagnetic whistler and lower hybrid like waves observed in the auroral zone using both wave and particle data. Our first task is to identify these wave modes and compare it with particle observations. Using both the DE-1 particle and wave measurements, we can positively identify those electromagnetics lower hybrid like waves as fast magnetosonic waves and the upper cutoff of these waves is the local lower hybrid frequency. From the upper cutoff of the frequency spectrum, one can infer the particle density and the result is in very good agreement with the particle data. Since these electromagnetic lower hybrid like waves can have frequencies extended down to the local ion cyclotron frequency, it practically confirms that they are not whistler waves.

Source record↗

Directional emittance surface measurement system and process

Apparatus and process for measuring the variation of directional emittance of surfaces at various temperatures using a radiometric infrared imaging system. A surface test sample is coated onto a copper target plate provided with selective heating within the desired incremental temperature range to be tested and positioned onto a precision rotator to present selected inclination angles of the sample relative to the fixed positioned and optically aligned infrared imager. A thermal insulator holder maintains the target plate on the precision rotator. A screen display of the temperature obtained by the infrared imager, and inclination readings are provided with computer calculations of directional emittance being performed automatically according to equations provided to convert selected incremental target temperatures and inclination angles to relative target directional emittance values. The directional emittance of flat black lacquer and an epoxy resin measurements obtained are in agreement with the predictions of the electromagnetic theory and with directional emittance data inferred from directional reflectance measurements made on a spectrophotometer.

Puram, Chith K.↗

Thermophysical Properties Measurement of High-Temperature Liquids Under Microgravity Conditions in Controlled Atmospheric Conditions

Microgravity conditions have advantages of measurement of surface tension and viscosity of metallic liquids by the oscillating drop method with an electromagnetic levitation (EML) device. Thus, we are preparing the experiments of thermophysical properties measurements using the Materials-Science Laboratories ElectroMagnetic-Levitator (MSL-EML) facilities in the international Space station (ISS). Recently, it has been identified that dependence of surface tension on oxygen partial pressure (Po2) must be considered for industrial application of surface tension values. Effect of Po2 on surface tension would apparently change viscosity from the damping oscillation model. Therefore, surface tension and viscosity must be measured simultaneously in the same atmospheric conditions. Moreover, effect of the electromagnetic force (EMF) on the surface oscillations must be clarified to obtain the ideal surface oscillation because the EMF works as the external force on the oscillating liquid droplets, so extensive EMF makes apparently the viscosity values large. In our group, using the parabolic flight levitation experimental facilities (PFLEX) the effect of Po2 and external EMF on surface oscillation of levitated liquid droplets was systematically investigated for the precise measurements of surface tension and viscosity of high temperature liquids for future ISS experiments. We performed the observation of surface oscillations of levitated liquid alloys using PFLEX on board flight experiments by Gulfstream II (G-II) airplane operated by DAS. These observations were performed under the controlled Po2 and also under the suitable EMF conditions. In these experiments, we obtained the density, the viscosity and the surface tension values of liquid Cu. From these results, we discuss about as same as reported data, and also obtained the difference of surface oscillations with the change of the EMF conditions.

Watanabe, Masahito↗

Starprobe - The science opportunities

The scientific objectives of the NASA Starprobe mission for an unmanned spacecraft to pass within three solar radii of the sun's surface are reviewed. Fundamental observations of gravitation, relativity, and factors related to the solar interior, measurements of the static and dynamic electromagnetic fields and the particle populations close to the sun, and observations of the solar atmosphere from the photosphere to the corona with high spatial resolution would be possible with the Starprobe. A determination of the quadrupole coefficient in the expansion of the gravitational potential field of the sun is noted to be possible by measuring the departure from a Keplerian orbit of the Starprobe as it passes perihelion, yielding data on the rate of revolution of the interior of the sun. Further information on shock acceleration, energy losses, radio bursts, interplanetary propagation, and diffusion will be available at 10-60 solar radii.

Underwood, J. H.↗

Review of measurements of the RF spectrum of radiation from lightning

A review is presented of the measurements reported in the literature of the spectrum of electromagnetic radiation from lightning in the frequency range from 1 kHz to 1 GHz. Measurements have been made either by monitoring the power received at individual frequencies using a narrow bandwidth recording device tuned to the frequencies under investigation or by recording the transient (time dependent) radiation with a wide bandwidth device and then Fourier transforming the waveform to obtain a spectrum. Measurements of the first type were made extensively in the 1950’s and 1960’s and several composite spectra have been deduced by normalizing the data of different investigators to common units of bandwidth and distance. The composite spectra tend to peak near 5 kHz and then decrease roughly as (frequency).’ upto nearly 100 MHz where scatter in the data make the behaviour uncertain. Measurements of the second type have been reported for return strokes, the stepped leader and for some intracloud processes. The spectrum of first return strokes obtained in this manner is very similar to the composite spectra obtained from the narrowband measurements.

Lightning Spectrum↗

Review of measurements of the RF spectrum of radiation from lightning

A review is presented of the measurements reported in the literature of the spectrum of electromagnetic radiation from lightning in the frequency range from 1 kHz to 1 GHz. Measurements have been made either by monitoring the power received at individual frequencies using a narrow bandwidth recording device or by recording the transient (time dependent) radiation with a wide bandwidth device and then Fourier transforming the waveform to obtain a spectrum. Measurements of the first type were made extensively in the 1950's and 1960's and several composite spectra have been deduced by normalizing the data of different investigators to common units of bandwidth and distance. The composite spectra tend to peak near 5 kHz and then decrease roughly as 1/(frequency) up to nearly 100 MHz where scatter in the data make the behaviour uncertain. The spectrum obtained with measurements of the second type is similar. Recent experiments have extended the frequency range covered to several 10's of MHz and include spectra for return strokes, the stepped leader and for some intracloud processes. The spectrum of first return strokes obtained in this manner is very similar to the spectrum of the composite flash obtained from the narrowband measurements.

Radiation↗

Preliminary Development and Testing of a Self-Injecting Gallium MPD Thruster

Discharge current and terminal voltage measurements were performed on a gallium electromagnetic thruster at discharge currents in the range of 20-54 kA. It was found that the arc impedance has a value of 6-7 m(Omega) at peak current. The absence of high-frequency oscillations in the terminal voltage trace indicates lack of the "onset" condition often seen in MPD arcs, suggesting that a sufficient number of charge carriers are present for current conduction. The mass ablated per pulse was not measured experimentally; however the mass flow rate was calculated using an ion current assumption and an anode power balance. Measurement of arc impedance predicts a temperature of 3.5 eV which from Saha equilibrium corresponds to Z = 2.0 - 3.5, and assuming Z = 2 yields an Isp of 3000 s and thrust efficiency of 50%.

Thomas, Robert E.↗

Determining the Hubble constant through cross-correlation of galaxies and gravitational waves

Gravitational-wave (GW) standard sirens have the potential to measure the Hubble constant 𝐻 0 in the local Universe independent of the distance ladder and thus offer unique insights into the Hubble tension. A key challenge with standard sirens is detecting their electromagnetic counterparts and therefore assigning redshifts to the measured distances. One promising way to proceed is to utilize GW dark sirens—events without an identified electromagnetic counterpart—and cross-correlate their angular distribution with that of galaxies. We present a quantitative study of how precisely the Hubble constant can be measured using tomographic cross-correlation between galaxies and GW sources. Altogether, we find that the constraints on 𝐻 0 will be limited by the quality and quantity of GW data. We find that percent-level constraints on 𝐻 0 will primarily depend on achieving small distance uncertainties (𝜎 𝑑𝐿 = 0.1⁢𝑑 𝐿 ), obtaining a large number of GW dark sirens (≳ 5⁢000) and accurate sky localization in the tomographic analysis.

Cosmological parameters↗