Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRON PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Differentiating Between H and F or H and CN on C(III) or Si(III) Surfaces

A Sc tipped probe molecule yields a larger difference for the probe-H vs probe-F interaction energies than our previously studied, electron-rich pyridine (C5H5N) and (CH3)3PO probes. However, the electron-deficient Sc tipped probe does not eliminate the probe-nearest data neighbor interaction problem associated with the C(III) surface. The difference in the probe-H and probe-F interaction energies is smaller for Si(III) than C(III), making it more difficult to differentiate between these two atoms on Si(III). The larger lattice constant for Si(III) significantly reduces the data atom-data atom interaction energy as well as the probe-neighbor interaction energies. This means that the H/CN system which is not practical for C(III) due to the CN-CN repulsion, is possible for Si(III). The difference in the probe-H and probe-CN interaction energies is very large for the H/CN data storage system, making this the best system studied to date. This system could be used on C(III) if a hydrogen 'fence' is built around each data site, which corresponds to using only one quarter of the surface sites for data storage.

Bauschlicher, Charles W.↗

Rocket radio measurement of electron density in the nighttime ionosphere

One experimental technique based on the Faraday rotation effect of radio waves is presented for measuring electron density in the nighttime ionosphere at midlatitudes. High frequency linearly-polarized radio signals were transmitted to a linearly-polarized receiving system located in a spinning rocket moving through the ionosphere. Faraday rotation was observed in the reference plane of the rocket as a change in frequency of the detected receiver output. The frequency change was measured and the information was used to obtain electron density data. System performance was evaluated and some sources of error were identified. The data obtained was useful in calibrating a Langmuir probe experiment for electron density values of 100/cu cm and greater. Data from two rocket flights are presented to illustrate the experiment.

Gilchrist, B. E.↗

Electron collection theory for a D-region subsonic blunt electrostatic probe

Blunt probe theory for subsonic flow in a weakly ionized and collisional gas is reviewed, and an electron collection theory for the relatively unexplored case, Deybye length approximately 1, which occurs in the lower ionosphere (D-region), is developed. It is found that the dimensionless Debye length is no longer an electric field screening parameter, and the space charge field effect can be negelected. For ion collection, Hoult-Sonin theory is recognized as a correct description of the thin, ion density-perturbed layer adjacent the blunt probe surface. The large volume with electron density perturbed by a positively biased probe renders the usual thin boundary layer analysis inapplicable. Theories relating free stream conditions to the electron collection rate for both stationary and moving blunt probes are obtained. A model based on experimental nonlinear electron drift velocity data is proposed. For a subsonically moving probe, it is found that the perturbed region can be divided into four regions with distinct collection mechanisms.

Wai-Kwong Lai, T.↗

A determination of the current density in electron beams

Current gathering rotating probe techniques were used to examine the envelope shape and power density profile of electron beams used in electron beam welding devices. The electron power density contours which determine the shape of the weld vapor cavity, penetration, and local heat distribution were considered. A mathematical analysis consistent with a rotating probe technique necessary to determine the current density distribution (assumed symmetrically radial) in a cross-section of the beam is provided. An explanation of the experimental technique for obtaining data, a BASIC language computer program to determine the current density from the data, and a study indicating the level of confidence to be associated with results obtained are also provided. An example of the application of the analysis to some experimental electron beam data is included.

Beil, R. J.↗

Comparison of probe and radar ionosphere temperatures

The discrepancy in temperature measurements of ionospheric electrons by Langmuir electrostatic probes, and radar backscatter are discussed. The discrepancy occurs at altitudes from 350 to 800km, and the probe temperatures are consistantly higher than the radar temperatures. It is concluded that the non-Maxwellian energy distribution provides an explanation for the altitude and the lower radar temperatures.

Hoegy, W. R.↗

Results of rocket measurements of D-region ionization over Thumba in MAP

Under MAP, two rockets were launched from Thumba (8.5 N, 76.8 E) around 1030 hrs Lt with identical payloads on 7 and 10 March 1986 for D region studies. Positive ion densities were measured by spherical probe and Gerdien condenser and electron densities were measured by Langmuir probe and propagation experiments. In both flights a valley in ionization height profile was noticed around 83 km. The density of ionization at this altitude was about 4 x 10(2) cu cm. A detailed positive ion-chemical scheme was used to reproduce the measured ionization height profiles. The density of NO needed to reproduce the valley in ionization at 83 km came around 5 x 10(5) cu cm. A photochemical treatment without diffusion process was found inadequate to explain this value of NO. Calculations showed that the value of vertical eddy diffusion needed to reproduce the value of NO was around 10(6)sq cm/s. Interestingly, the same value of eddy diffusion coefficient was obtained when derived in the manner described by Thrane and his coworkers using only the positive ion current data of spherical probes.

Chakrabarty, D. K.↗

Farfield Plume Measurement and Analysis on the NASA-300M

NASA is developing a 15-kW Hall thruster to support future NASA missions. This activity is funded under the Space Technology Mission Directorate Solar Electric Propulsion Technology Demonstration project. As a part of the development process, the far-field plume characteristics of the NASA-300M, a 20-kW Hall thruster, were studied. The results will be used to study how various aspects of the operation of this thruster affect the overall performance. This data will be used to guide future design work and serve as a baseline for comparison to a magnetically shielded version of the NASA-300M that will be tested in the future. For this study, a far-field Faraday probe was swept in a polar fashion to map the ion current density. An ExB probe (Wien filter), two retarding potential analyzers, and a Langmuir probe were mounted at a fixed location on the thruster axis in the far-field plume. The data reduction method followed recommendations in recent studies by Brown, Reid, and Shastry with modifications that are tailored to the plasma plume environment of high-power Hall thrusters. Results from this and prior testing show that the plume is richer in doubly-charged ions, larger in spatial extent, and capable of greater probe heating than lower power thrusters. These characteristics require special treatment in experimental setup and data analysis, which will be the main focus of this paper. In particular, covered topics will include a new, more accurate, method of integration for analysis of the ExB probe data and effect of secondary electron emission on the Faraday probe data.

Huang, Wensheng↗

Investigation of the arcjet plume near field using electrostatic probes

The near field plum of a 1 kW class arcjet thruster was investigated using electrostatic probes of various geometries. The electron number densities and temperatures were determined in a simulated hydrazine plume at axial distances between 3 cm (1.2 in) and 15 cm (5.9 in) and radial distances extending to 10 cm (3.9 in) off centerline. Values of electron number densities obtained using cylindrical and spherical probes of different geometries agreed very well. The electron density on centerline followed a source flow approximation for axial distances as near as 3 cm (1.2 in) from the nozzle exit plane. The model agreed well with previously obtained data in the far field. The effects of propellant mass flow rate and input power level were also studied. Cylindrical probes were used to obtain ion streamlines by changing the probe orientation with respect to the flow. The effects of electrical configuration on the plasma characteristics of the plume were also investigated by using a segmented anode/nozzle thruster. The results showed that the electrical configuration in the nozzle affected the distribution of electrons in the plume.

Sankovic, John M.↗

Investigation of the Arcjet near Field Plume Using Electrostatic Probes

The near field plume of a 1 kW class arcjet thruster was investigated using electrostatic probes of various geometries. The electron number densities and temperatures were determined in a simulated hydrazine plume at axial distances between 3 cm (1.2 in.) and 15 cm (5.9 in.) and radial distances extending to 10 cm (3.9 in.) off centerline. Values of electron number densities obtained using cylindrical and spherical probes of different geometries agreed very well. The electron density on centerline followed a source flow approximation for axial distances as near as 3 cm (1.2 in.) from the nozzle exit plane. The model agreed well with previously obtained data in the far field. The effects of propellant mass flow rate and input power level were also studied. Cylindrical probes were used to obtain ion streamlines by changing the probe orientation with respect to the flow. The effects of electrical configuration on the plasma characteristics of the plume were also investigated by using a segmented anode/nozzle thruster. The results showed that the electrical configuration in the nozzle affected the distribution of electrons in the plume.

Sankovic, John M.↗

The behavior of the plasmapause at mid-latitudes: ISIS-1 Langmuir probe measurements

Observations of the electron concentration, N sub e, and temperature, T sub e, from the electrostatic probes on the ISIS-1 satellite were used to examine the location and behavior of the plasmapause at about 3000 kilometers altitude in the vicinity of L = 4. At these altitudes, the N sub e measurements are equivalent to measurements of H(+) since the satellite is well into the protonosphere. The plasmapause as is evident as a sharp drop in N sub e by a factor of 10 to 100 as the satellite passes into the polar cap, and a corresponding increase is observed as it enters the plasmasphere on the opposite side of the Earth. An enhancement of T sub e is also observed at the plasmapause, an effect that is most visible at night when the temperatures at latitudes above and below the plasmapause are usually very low. The position of the plasmapause decreases with magnetic activity but is found to be somewhat less sensitive to K sub p than is the equatorial plasmapause. Also unlike its equatorial behavior, the mid-latitude plasmapause exhibits no detectable late afternoon bulge. These differences imply rather complex coupling of the thermal plasma along the field lines that link these two regions of the plasmasphere. An additional factor may be the recently observed axial asymmetry in the geomagnetic field at high altitudes.

Brace, L. H.↗

An RF heated tandem mirror plasma propulsion study

Experimental results on a tandem mirror hybrid plume rocket involving a three-stage system of plasma injection, heating, and subsequent injection through a magnetic nozzle are presented. In the experiments, a plasma is created by breaking down the gas with electron cyclotron resonance heating at 2 kW in the central cell, and the ion species is then heated to high temperatures with ion cyclotron resonance heating at 10 kW in the end cell. A Langmuir probe measured an electron density of 2.5 x 10 to the 16th/cu m and a temperature of 100 eV in the central cell and an ion density of 1.25 x 10 to the 17th/cu m and a temperature of 500 eV in the end cell.

Yang, T. F.↗

Spaceflight KID Readout Electronics Development for PRIMA

We present the design and testing of spaceflight multiplexing kinetic inductance detector (KID) readout electronics for the PRobe far-Infrared Mission for Astrophysics (PRIMA). PRIMA is a mission proposed to the 2023 NASA Astrophysics Probe Explorer (APEX) Announcement of Opportunity that will answer fundamental questions about the formation of planetary systems, as well as the formation and evolution of stars, supermassive black holes, and dust over cosmic time. The readout electronics for PRIMA must be compatible with operation at Earth-Sun L2 and capable of multiplexing more than 1000 detectors over 2 GHz bandwidth while consuming around 30 W per readout chain. The electronics must also be capable of switching between the two instruments, which have different readout bands,: the hyperspectral imager (PRIMAger, 2.5-5.0 GHz) and the spectrometer (FIRESS, 0.4-2.4 GHz). We present the driving requirements, design, and measured performance of a laboratory brassboard system.

Sumit Dahal↗

Evidence for two different structuring and scattering mechanisms and the associated role of aerosols in the polar summer mesosphere

A Super Arcas rocket, MISTI B, was launched as part of the Polar Mesospheric Summer Echoes (PMSE) salvo to measure electron density irregularities using rf and dc probes. Large and small scale structures in the electron density were measured on rocket ascent and descent at the altitudes of 86.5 and 88.5 +/- .5 km. Since the rocket apogee was 89 km, the rocket was in the height range 88.5 +/- .5 km for 30 seconds giving us an unusual measurement of horizontal structure over a distance of 5.5 km. A power spectrum of the fluctuations for the upper layer gives further evidence that turbulent mixing is an important process in PMSE. The power spectrum of the lower layer, however, gives evidence that this layer is characterized by a form of partial or Fresnel scattering. Both spectra are in excellent agreement with similar analysis of electron fluctuation spectra measured in the same layers on the TURBO-B rocket flown 12 minutes later and the analysis of Cornell University Portable Radar Interferometer (CUPRI) data by Cho et al., 1993A. Thus two different structuring and scattering mechanisms exist at altitudes only 1 km apart. Using the simultaneous dc and rf probe measurements of electron depletions and sharp gradients in the lower layer, we speculate on the role of aerosols in creating these depletions and gradients.

Ulwick, J. C.↗

A measurement technique of time-dependent dielectric breakdown in MOS capacitors

The statistical nature of time-dependent dielectric breakdown characteristics in MOS capacitors was evidenced by testing large numbers of capacitors fabricated on single wafers. A multipoint probe and automatic electronic visual display technique are introduced that will yield statistical results which are necessary for the investigation of temperature, electric field, thermal annealing, and radiation effects in the breakdown characteristics, and an interpretation of the physical mechanisms involved. It is shown that capacitors of area greater than 0.002 sq cm may yield worst-case results, and that a multipoint probe of capacitors of smaller sizes can be used to obtain a profile of nonuniformities in the SiO2 films.

Li, S. P.↗

Electron temperature and concentration in a thermal atomic oxygen source

A thermal atomic oxygen source for materials screening was built for NASA by Boeing Aerospace. The objective here was to use a microwave interferometer and Langmuir probe to characterize the electron concentration in this thermal atomic oxygen source. Typical operating conditions in the thermal atomic oxygen source were found to produce electron concentrations that were well below the detection threshold of the interferometer (10(exp 8) cm (sup -3)). The researchers calibrated (with the interferometer) the Langmuir probe at an artificially high plasma density and then used the circular and the square Langmuir probes to measure the low electron concentrations that exist during materials exposure tests. Electron concentration was measured as a function of power and position. The electrons were lost to the walls through ambipolar diffusion, and their concentration was accurately described by an equation. The electron concentration was proportional to power squared and decayed exponentially with distance.

Pedrow, Patrick Dennis↗