Search NASA⌕ Search

SEARCH · Search NASA

Results for “ENERGY DISTRIBUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

State Regulatory Opportunities to Advance Distributed Energy Resource Aggregations in Wholesale Markets

The report discusses how state regulators can promote the participation of DERs in wholesale markets, including complementary actions that they can take to support Federal Energy Regulatory Commission Order 2222 implementation. It also summarizes wholesale market operators’ Order 2222 compliance and associated compliance challenges along with potential state regulator roles. The report identifies actions that state regulators can take to accelerate DER aggregations providing grid services.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Secure Distributed Energy Resource Communications (sDERC)

The slides will be presented at a DOE CESER Peer Review for the Risk Management Tools and Technology (RMT) that provide an overview of the sDERC project. The slides discuss the project plan for this new project and how the results will be demonstrated at the conclusion of this project. The peer review is scheduled for August 27-29.

Chavez, Adrian R.↗

Hydrogen Transportation and Distributed Energy Systems Seismic Risk Assessment for Cascadia Subduction Zone Airport Facilities

Portland International Airport in Oregon is exploring operating a fleet of 28 fuel cell electric buses to support airport operations and possibly provide backup power during outages. In this report, we evaluate the risk of hydrogen deployment at an airport considering the potential for seismic activity. We present a seismic risk assessment for pressurized piping for a generic hydrogen refueling station at the airport. Only pressurized piping was considered in the risk analysis because of its vulnerability and availability of fragility information unlike the other components. Seismic capacity of other components should be included as more information becomes available.

08 HYDROGEN↗

​​Hydrogen Transportation and Distributed Energy Systems Seismic Risk Assessment for Cascadia Subduction Zone Airport Facilities​

Portland International Airport in Oregon is exploring operating a fleet of 28 fuel cell electric buses to support airport operations and possibly provide backup power during outages. In this report, we evaluate the risk of hydrogen deployment at an airport considering the potential for seismic activity. We present a seismic risk assessment for pressurized piping for a generic hydrogen refueling station at the airport. Only pressurized piping was considered in the risk analysis because of its vulnerability and availability of fragility information unlike the other components. Seismic capacity of other components should be included as more information becomes available. To characterize the seismic hazard, we considered the initiating event frequency of a Cascadia Subduction Zone earthquake event based on data from the literature. Seismic stressors that translate to the site from an earthquake event are expressed as peak ground acceleration. Site disturbance is characterized as a function of soil conditions, represented by different shear wave velocity values, which affect how seismic waves propagate and impact structures. Pipe fragility curves as a function of seismic capacity were used to correlate ground acceleration and failure probability. These fragility characteristics were combined with site-specific soil conditions to calculate the probability of pipe rupture during a seismic event. It should be noted that multiple simultaneous failures due to an earthquake event as a common cause are not considered. Some epistemic uncertainties such as self-exciting shocks, aftershocks, and the time variant nature of the ground motion are not considered either.

08 HYDROGEN↗

Evaluate Distributed Energy Technologies for Cost Savings and Resilience With REopt Lite

NREL's REopt Lite TM web tool evaluates the economics of grid connected photovoltaics (PV), wind, and battery storage at a site. It allows users to identify the system sizes and battery dispatch strategy that minimize a site's life cycle cost of energy, and it estimates the amount of time a PV, wind, battery, and diesel generator system can sustain the site's critical load during a grid outage.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Real time feedback-based optimization of distributed energy resources

An example device includes a processor configured to receive a plurality of voltage values representing respective voltage magnitudes at voltage nodes in a first portion of a power system and determine, for each voltage node, a respective value of first and second voltage-constraint coefficients. The processor is also configured to receive a power value corresponding to a connection point of the first portion of the power system with a second portion of the power system and determine for the connection point, a respective value of first and second power-constraint coefficients. The processor is also configured to cause at least one energy resource connected to the first portion of the power system to modify an output power of the at least one energy resource based on the value of the first and second voltage-constraint coefficients for each voltage node and the value of the first and second power-constraint coefficients.

Dall'Anese, Emiliano↗

Power system restoration incorporating diverse distributed energy resources

An example system includes an aggregator configured to receive a service collaboration request and iteratively determine, based on minimum and maximum power values for DERs under its management, an optimized operation schedule. The aggregator may also be configured to iteratively determine, based on the optimized operation schedule, an estimated flexibility range for devices under its management and output an indication thereof. The system may also include a power management unit (PMU) configured to iteratively receive the indication and determine, based on a network model that includes the estimated flexibility range, a reconfiguration plan and an overall optimized operation schedule for the network. The PMU may also be configured to iteratively cause reconfiguration of the network based on the plan. The PMU and aggregator may also be configured to iteratively, at a fast timescale, cause energy resources under their management to modify operation based on the overall optimized operation schedule.

Ding, Fei↗

Real time feedback-based optimization of distributed energy resources

An example device includes a processor configured to receive a plurality of voltage values representing respective voltage magnitudes at voltage nodes in a first portion of a power system and determine, for each voltage node, a respective value of first and second voltage-constraint coefficients. The processor is also configured to receive a power value corresponding to a connection point of the first portion of the power system with a second portion of the power system and determine for the connection point, a respective value of first and second power-constraint coefficients. The processor is also configured to cause at least one energy resource connected to the first portion of the power system to modify an output power of the at least one energy resource based on the value of the first and second voltage-constraint coefficients for each voltage node and the value of the first and second power-constraint coefficients.

Dall'Anese, Emiliano↗

Modifications to the Thermal Energy Distribution System (TEDS)

INL installed a new controls system and a flame detection system on TEDS as part of upgrades that will eventually allow unattended operation and integration with accessory systems, such as digital twins, or facilities in other locations. These upgrades resolve some corrective actions that came about when oil was spilled from a high-point vent during system startup testing.

42 ENGINEERING↗

Techno-Economic Assessment of Data Center Load Demand Powered by Small Modular Reactors and Distributed Energy Resources

The rapid increase in data center energy demand, driven by AI and large-scale data processing, poses significant challenges to global energy infrastructure. Data centers require substantial and reliable energy for continuous operations and high-performance computing. Current electrical grids face issues such as transmission bottlenecks and aging infrastructure, making it difficult to meet these demands. Integrating inverter-based-resources (IBRs) like solar and wind presents both opportunities and challenges due to their intermittent nature. Small Modular Reactors (SMRs) offer a promising solution with their enhanced safety, modularity, reliability, and scalability, providing consistent base load power ideal for data center operations. This study presents a comprehensive techno-economic assessment of powering data center load demand using a combination of SMRs and IBRs with grid-connected and islanded mode. This study utilized Idaho National Laboratory’s (INL) HPC data center hourly load profiles and Xendee microgrid optimization platform to conduct the analysis. In this configuration, SMRs serves as the primary base load power source, consistently providing a steady supply of electricity necessary to meet the minimum load demand of the data center with support from the IBRs. Key performance indicators such as Levelized Cost of Electricity (LCOE), Net Present Value (NPV) has been calculated to assess the economic feasibility. The findings from this research will underscore the strategic benefits of integrating SMR plant with DERs – particularly for critical infrastructure load such as data centers.

14 - SOLAR ENERGY↗