Analyses of mean and turbulent motion in the tropics with the use of unequally spaced data

Wind velocities from 25 km to 60 km over Ascension Island, Fort Sherman and Kwajalein for the period January 1970 to December 1971 are analyzed in order to achieve a better understanding of the mean flow, the eddy kinetic energy and the Eulerian time spectra of the eddy kinetic energy. Since the data are unequally spaced in time, techniques of one-dimensional covariance theory were utilized and an unequally spaced time series analysis was accomplished. The theoretical equations for two-dimensional analysis or wavenumber frequency analysis of unequally spaced data were developed. Analysis of the turbulent winds and the average seasonal variance and eddy kinetic energy of the turbulent winds indicated that maximum total variance and energy is associated with the east-west velocity component. This is particularly true for long period seasonal waves which dominate the total energy spectrum. Additionally, there is an energy shift for the east-west component into the longer period waves with altitude increasing from 30 km to 50 km.

Kao, S. K.↗

Isotopic stack - measurement of heavy cosmic ray isotopes

Heavy cosmic ray nuclei with nuclear charge, Z, equal to or greater than 3 are to be measured using an isotopic stack consisting of passive visual track detectors which remain sensitive throughout the entire mission. The scientific data are stored in latent tracks which are produced by heavy ions and which can be revealed in the investigator's laboratory after recovery. During the mission, only housekeeping data have to be collected. The exposure onboard Spacelab 1 allows the study of the chemical composition and energy spectrum of articles which have energies in the range 20 to 100 million electron volts per atomic mass unit, as well as the isotopic composition of heavy galactic cosmic rays with energies in the range 100 to 1000 million electron volts per atomic mass unit.

Beaujean, R.↗

An Observatory to Study 10 (10) to 10 (17) EV Gamma Rays

A facility is described which incorporates many of the best features of existing gamma ray telescopes at a single site. In addition to reducing the flux sensitivity in some energy ranges, it permits the measurements of the energy spectrum over seven decades of energy.

Weekes, T. C.↗

AGC-4 As-Run Uncertainty Analysis

The concept of measuring neutron flux (or fluence rate) with activation foils has existed since the late 1940s and is a well-used methodology. Activation foils are selected for their unique isotopic cross sections that create reaction products with desirable properties: relatively simple radioactive decay scheme, measurable quantities of gamma-rays or betas, and half-lives appropriate for the irradiation and decay durations of the experiment. The activation materials, deemed flux wires, fluence wires, dosimeters, or flux foils, are fabricated to have a mass appropriate for the irradiation as well so the measurement using a radiation detector following the irradiation is sufficient but not overwhelming in terms of total activity. Activation measurement results are expressed in terms of reaction rate, which can then be used to “adjust” the neutron spectrum. The Advanced Graphite Creep (AGC)-4 experiment contained 26 flux wire packages, each containing an iron and a niobium wire inside a vanadium capsule. For all stackup positions, the value of fast to thermal neutrons is higher than expected, but the total neutron fluence is near the predicted value of ~2 x 1022 n/cm2. As compared to the predicted neutron spectrum, there are four takeaways in the results as compared to the predicted ATR irradiation: 1) Additional fast (fission) neutrons present, 2) Spectrum hardening due to temperature, 3) Spectrum hardening due to container attenuation, 4) Total neutron fluence is close to predicted values. Since the neutron energy spectrum is a key parameter when attributing neutron damage in materials, the adjusted energy-dependent spectrum and the total neutron fluence results from the dosimeters can be incorporated for future calculations.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High energy primary electron spectrum observed by the emulsion chamber

A detector of the emulsion chamber type is used to measure the energy spectrum of cosmic-ray electrons. Two large emulsion chambers, each having an area of 40 by 50 sq cm, are exposed for about 25.5 hr at an average pressure altitude of 3.9 mbar. About 500 high-energy cascades (no less than about 600 GeV) are detected by searching for dark spots on the X-ray films. A power-law energy dependence formula is derived for the spectrum of primary cosmic-ray electrons in the energy region over 100 GeV. The results are in good agreement with the transition curves obtained previously by theoretical and Monte Carlo calculations.

Nishimura, J.↗

Proton albedo spectrum observation in low latitude region at Hyderabad, India

The flux and the energy spectrum of low energy (30-100 MeV) proton albedos, have been observed for the first time in a low latitude region, over Hyderabad, India. The preliminary results, based on the quick look data acquisition and display system are presented. A charged particle telescope, capable of distinguishing singly charged particles such as electrons, muons, protons in low energy region, records the data of both upward as well as downward moving particles. Thus spectra of splash and re-entrant albedo protons have been recorded simultaneously in a high altitude Balloon flight carried out on 8th December, 1985, over Hyderabad, India. Balloon floated at an latitude of approx. 37 km (4 mb).

Verma, S. D.↗

Radar scattering from the sea

Stereo ocean profiles of height versus distance for rough sea conditions and energy spectrum for high frequencies

OCEANOGRAPHY↗

X-Ray Spectro-Polarimetry with Photoelectric Polarimeters

We derive a generalization of forward fitting for X-ray spectroscopy to include linear polarization of X-ray sources, appropriate for the anticipated next generation of space-based photoelectric polarimeters. We show that the inclusion of polarization sensitivity requires joint fitting to three observed spectra, one for each of the Stokes parameters, I(E), U(E), and Q(E). The equations for StokesI (E) (the total intensity spectrum) are identical to the familiar case with no polarization sensitivity, and for which the model-predicted spectrum is obtained by a convolution of the source spectrum, F (E), with the familiar energy response function,(E) R(E,E), where (E) and R(E,E) are the effective area and energy redistribution matrix, respectively. In addition to the energy spectrum, the two new relations for U(E) and Q(E) include the source polarization fraction and position angle versus energy, a(E), and 0(E), respectively, and the model-predicted spectra for these relations are obtained by a convolution with the modulated energy response function, (E)(E) R(E,E), where(E) is the energy-dependent modulation fraction that quantifies a polarimeters angular response to 100 polarized radiation. We present results of simulations with response parameters appropriate for the proposed PRAXyS Small Explorer observatory to illustrate the procedures and methods, and we discuss some aspects of photoelectric polarimeters with relevance to understanding their calibration and operation.

polarization↗

Improved spatial uniformity of beam-plane interaction by means of inverse rastering

An analysis is presented that shows the desirability and feasibility of conducting irradiations of large test objects by beams of penetrating radiation, by the method of moving the test object back and forth through the beam, rather than by sweeping the beam across the object. An extension of this method of inverse rastering allows the generation of composite beams with any desired intensity-vs-energy spectrum, obviating the need to determine equivalent damage factors for every energy in the spectrum.

Miller, C. G.↗