Search NASA⌕ Search

SEARCH · Search NASA

Results for “EVAPORATION MODEL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Evaporation-driven instability of the precorneal tear film

Tear-film instability is widely believed to be a signature of eye health. When an interblink is prolonged, randomly distributed ruptures occur in the tear film. "Black spots" and/or "black streaks" appear in 15 to 40 s for normal individuals. For people who suffer from dry eye, tear-film breakup time (BUT) is typically less than a few seconds. To date, however, there is no satisfactory quantitative explanation for the origin of tear rupture. It was proposed recently that tear-film breakup is related to locally high evaporative thinning. A spatial variation in the thickness of the tear-film lipid layer (TFLL) may lead to locally elevated evaporation and subsequent tear-film breakup. We examine the local-evaporation-driven tear-film-rupture hypothesis in a one-dimensional (1-D) model for the evolution of a thin aqueous tear film overriding the cornea subject to locally elevated evaporation at its anterior surface and osmotic water influx at its posterior surface. Evaporation rate depends on mass transfer both through the coating lipid layer and through ambient air. We establish that evaporation-driven tear-film breakup can occur under normal conditions but only for higher aqueous evaporation rates. Predicted roles of environmental conditions, such as wind speed and relative humidity, on tear-film stability agree with clinical observations. More importantly, locally elevated evaporation leads to hyperosmolar spots in the tear film and, hence, vulnerability to epithelial irritation. In addition to evaporation rate, tear-film instability depends on the strength of healing flow from the neighboring region outside the breakup region, which is determined by the surface tension at the tear-film surface and by the repulsive thin-film disjoining pressure. This study provides a physically consistent and quantitative explanation for the formation of black streaks and spots in the human tear film during an interblink.

dry eye↗

A conceptual geochemical model of the geothermal system at Surprise Valley, CA

Characterizing the geothermal system at Surprise Valley (SV), northeastern California, is important for determining the sustainability of the energy resource, and mitigating hazards associated with hydrothermal eruptions that last occurred in 1951. Previous geochemical studies of the area attempted to reconcile different hot spring compositions on the western and eastern sides of the valley using scenarios of dilution, equilibration at low temperatures, surface evaporation, and differences in rock type along flow paths. These models were primarily supported using classical geothermometry methods, and generally assumed that fluids in the Lake City mud volcano area on the western side of the valley best reflect the composition of a deep geothermal fluid. In this contribution, we address controls on hot spring compositions using a different suite of geochemical tools, including optimized multicomponent geochemistry (GeoT) models, hot spring fluid major and trace element measurements, mineralogical observations, and stable isotope measurements of hot spring fluids and precipitated carbonates. We synthesize the results into a conceptual geochemical model of the Surprise Valley geothermal system, and show that high-temperature (quartz, Na/K, Na/K/Ca) classical geothermometers fail to predict maximum subsurface temperatures because fluids re-equilibrated at progressively lower temperatures during outflow, including in the Lake City area. We propose a model where hot spring fluids originate as a mixture between a deep thermal brine and modern meteoric fluids, with a seasonally variable mixing ratio. The deep brine has deuterium values at least 3 to 4‰ lighter than any known groundwater or high-elevation snow previously measured in and adjacent to SV, suggesting it was recharged during the Pleistocene when meteoric fluids had lower deuterium values. The deuterium values and compositional characteristics of the deep brine have only been identified in thermal springs and groundwater samples collected in proximity to structures that transmit thermal fluids, suggesting the brine may be thermal in nature. On the western side of the valley at the Lake City mud volcano, the deep brine-meteoric water mixture subsequently boils in the shallow subsurface, precipitates calcite, and re-equilibrates at about 130 °C. On the eastern side of the valley, meteoric fluid mixes to a greater extent with the deep brine, cools conductively without boiling, and the composition is modified as dissolved elements are sequestered by secondary minerals that form along the cooling and outflow path at temperatures <130 °C. Re-equilibration of geothermal fluids at lower temperatures during outflow explains why subsurface temperature estimates based on classical geothermometry methods are highly variable, and fail to agree with temperature estimates based on dissolved sulfate-oxygen isotopes and results of classical and multicomponent geothermometry applied to reconstructed deep well fluids. Furthermore, the proposed model is compatible with the idea suggested by others that thermal fluids on the western and eastern side of the valley have a common source, and supports the hypothesis that low temperature re-equilibration during west to east flow is the major control on hot spring fluid compositions, rather than dilution, evaporation, or differences in rock type.

15 GEOTHERMAL ENERGY↗

Optimization of lithium vapor box divertor evaporator location on NSTX-U using SOLPS-ITER

Commercial fusion reactors will be faced with extremely high divertor target heat fluxes that will require mitigation. Simulations of detachment in an NSTX-U scenario projected to have 92 MW/m 2 unmitigated peak target heat flux are presented, which reaches sub-10 MW/m 2 target heat flux using a highly dissipating lithium vapor box divertor design. The lithium vapor box is a detached divertor design which employs lithium vapor evaporation and condensation to contain lithium below the X-point. Previous SOLPS modeling has indicated a lithium vapor box can reduce the heat flux down to 10 MW/m 2 via simultaneous evaporation from the Private Flux Region (PFR) and the Common Flux Region (CFR) sides of the vapor box. It is found here that PFR evaporation has improved access to the separatrix leading to significantly more efficient power dissipation than CFR evaporation. Simulations of target evaporation with an evaporation distribution that is self-consistent with the temperature of a Capillary Porous System with Fast flowing liquid lithium (CPSF) could reach n Li / n e ~ 0.025-0.030 at the Last Closed Flux Surface (LCFS) depending on the liquid metal flow speeds and lithium sputtering yield, while PFR-side evaporation can reach acceptable heat fluxes with n Li / n e ~ 0.038 at the LCFS. However, PFR evaporator performance can be improved if the target is allowed to be hot enough such that it reflects lithium, reaching n Li / n e ~ 0.028 and reducing required lithium evaporation. Ultimately PFR evaporation and target evaporation are found to have similar ability to produce acceptable heat flux solutions with minimal upstream concentration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a thermosyphon-based thermal valve for controlled high-temperature heat extraction

Conventional concentrated solar power (CSP) is a reliable alternative energy source that uses the sun’s heat to drive a heat engine to produce electrical power. An advantage of CSP is its ability to store thermal energy for use during off-sun hours which is typically done by storing sensible heat in molten salts. Alternatively, thermal energy may be stored as latent heat in a phase-change material (PCM), which stores large quantities of thermal energy in an isothermal process. On-sun, the PCM melts, storing energy. Off-sun, the latent heat is extracted to produce dispatchable electrical power. Here, this paper presents the design of a thermosyphon-based device with sodium working fluid that is able to extract heat from a source as demand requires. A prototype has been designed to transfer 37 kW of thermal energy from a 600°C molten PCM tank to an array of 9% efficient thermoelectric generators (TEGs) to produce 3 kW of usable electrical energy for 5 h. This “thermal valve” design incorporates a funnel to collect condensate and a central shut-off valve to control condensate gravity return to the evaporator. Three circumferential tubes allow vapour transport up to the condenser. Pressure and a thermal resistance models were developed to predict the performance of the thermal valve. The pressure model predicts that the thermal valve will function as designed. The thermal resistance model predicts a 5500× difference in total thermal resistance between “on” and “off” states. The evaporator and condenser walls comprise 96% of the “on” thermal resistance, while the small parasitic heat transfer in the “off” state is primarily (77%) due to radiation losses. Lastly, this simple and effective technology can have a strong impact on the feasibility, scalability, and dispatchability of CSP latent storage. In addition, other industrial and commercial applications can benefit from this thermal valve concept.

14 SOLAR ENERGY↗

A hierarchical gray-box dynamic modeling methodology for direct-expansion cooling systems to support control stability analysis; Méthodologie de modélisation dynamique hiérarchique de type boîte grise pour les systèmes de refroidissement à détente directe afin de soutenir l'analyse de stabilité de la commande

In this paper, a gray-box dynamic modeling approach for direct-expansion cooling systems is presented. The overall approach incorporates a multi-stage training procedure that consists of 1) identification of component sub-models from quasi-steady-state performance data, 2) system model integration with estimation of refrigerant charge and 3) fine tuning of thermal capacitances of the evaporator and condenser to capture the system dynamic responses. Compared to traditional physics-based models, the proposed modeling approach has advantages including reduced engineering efforts in the model development phase, improved computational efficiency and enhanced prediction accuracy. The modeling method was validated using a 3-ton variable-speed heat pump and proved to be capable of accurately predicting the system transient behaviors over a wide range of operating conditions. The established dynamic model was then applied for control stability analysis, with a specific goal of determining a proper control execution time step. The case study results showed that the stable control execution time step could change significantly, from 3 sec to 19 sec, as the operating conditions and control settings vary, and a proper selection of the execution time step is critical to ensure stable and reliable operations.

42 ENGINEERING↗

High Level Waste in Salt Repositories: Experiments and Simulations of Evaporation in the Underground - 17167

Advances in simulation of coupled heat and mass transfer in granular salt using the Finite Element Heat and Mass Transfer Code (FEHM) is presented in this paper. The modeling focuses on reproducing the results of an in-situ subsurface evaporation experiment beginning during the summer of 2015 carried out in the underground at the Waste Isolation Pilot Plant (WIPP). Run-of-mine (granular) salt was placed in a metal pan, and sample mass, as well as ambient temperature and humidity, were measured continuously on a data logger through May 2016. Changes in moisture content of the salt are interpreted from the change in mass, and these data provide insight into evaporation and water retention characteristics from salt in the WIPP underground. To allow simulation of the experimental data, FEHM was modified to include a variable humidity boundary condition. The new humidity boundary condition can adjust streams of inflowing air to reflect fractions of air and water at prescribed temperature and pressure conditions that in turn represent relative humidity. Attributes for the flow such as temperature, air mass fraction, and humidity can be specified for inflowing air. The in-situ experiment provided data for validation of FEHM code development to accurately compute water-vapor pressure lowering due to dissolved salt and capillary pressure for pore water stored granular WIPP salt. Using this new boundary condition capabilities, a numerical representation of the pan experiment was created. The numerical domain is a 2-dimensional square grid of 30 by 30 cm axes. Salt and air properties are assigned based on measured values. A low flow rate of air is specified across the pile of salt to represent drift ventilation airflow. Humidity and temperature of the flowing air are fixed to measured values, and the simulated pile of salt is allowed to take up or release water based only on gradients in humidity and water-vapor pressure. Mass changes of the modeled salt pan were compared to measured mass changes in the bench-scale experiment. Directionality of the modeled changes tracks well with measured values, with good correlation between peak and valley inflection points. This shows that in situations with airflow where the relative humidity boundary can apply, FEHM can produce accurate values if humidity, air flow, and initial conditions are well established. Finally, this work supports phased-field-thermal testing in salt planned for the underground at WIPP that is expected to begin in early 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ground heat flux: An analytical review of 6 models evaluated at 88 sites and globally

Uncertainty in ground heat flux (G) means that evaluation of the other terms in the surface energy balance (e.g., latent and sensible heat fluxes (LE and H)) remains problematic. Algorithms that calculate LE and H require available energy, the difference between net radiation, R NET , and G. There are a wide range of approaches to model G for large-scale applications, with a subsequent wide range of estimates and accuracies. Here, we provide the largest review of these methods to date (N = 6), evaluating modeled G against measured G from 88 FLUXNET sites. The instantaneous midday variability in G is best captured by models forced with net radiation, while models forced by temperature show the least error at both instantaneous and daily time scales. We produce global decadal data sets of G to illustrate regional and seasonal sensitivities, as well as uncertainty. Global model mean midmorning instantaneous G is highest during September, October, and November at 63.42 (±16.84) Wm -2 , while over December, January, and February G is lowest at 53.86 (±18.09) Wm -2 but shows greater intermodel uncertainty. Results from this work have the potential to improve evapotranspiration estimates and guide appropriate G model selection and development for various land uses.

58 GEOSCIENCES↗

A Numerical Analysis of The Pool Boiling Process in Flooded Evaporators Using Different Refrigerants

The pool boiling process can be observed in several energy conversion processes including commercial and industrial refrigeration, industrial air-cooling operations, and power generation. The process becomes more involved when pool boiling in a tube bundle is considered. In the current study, a numerical model is developed to predict the key performance parameters of a flooded evaporator while considering a range of working fluids. A kettle reboiler configuration was considered, and a performance model was developed to account for boiling on individual tubes, merging of vapor bubbles, and movement under gravity. A volume of fluid (VOF) model was used to deal with the different phases in the simulation. Various fluids were considered in this study including HFE-7000, HFE-7300, and water. The trajectories of the bubbles were tracked, and the resulting information has been summarized in physical measurable quantities.

Zhang, Mingkan↗

Determination of the 60 Zn level density from neutron evaporation spectra

Nuclear reactions of interest for astrophysics and applications often rely on statistical model calculations for nuclear reaction rates, particularly for nuclei far from β stability. However, statistical model parameters are often poorly constrained, where experimental constraints are particularly sparse for exotic nuclides. For example, our understanding of the breakout from the NiCu cycle in the astrophysical rp-process is currently limited by uncertainties in the statistical properties of the proton-rich nucleus 60 Zn. We have determined the nuclear level density of 60 Zn using neutron evaporation spectra from 58 Ni( 3 He,n) measured at the Edwards Accelerator Laboratory. We compare our results to a number of theoretical predictions, including phenomenological, microscopic, and shell-model-based approaches. Notably, we find the 60 Zn level density is somewhat lower than expected for excitation energies populated in the 59 Cu(p,γ) 60 Zn reaction under rp-process conditions. This includes a level density plateau from roughly 5 to 6 MeV excitation energy, which is counter to the usual expectation of exponential growth and all theoretical predictions that we explore. Here, a determination of the spin distribution at the relevant excitation energies in 60 Zn is needed to confirm that the Hauser-Feshbach formalism is appropriate for the 59 Cu(p,γ) 60 Zn reaction rate at x-ray burst temperatures

59 ≤ A ≤ 89↗

Microstructure in matrix elements

We investigate the simple model of Pennington, Shenker, Stanford and Yang for modeling the density matrix of Hawking radiation, but further include dynamics for EOW branes behind the horizon. This allows interactions that scatter one interior state to another, and also allows EOW loops. At strong coupling, we find that EOW states are no longer random; the ensemble has collapsed, and coupling constants encode the microscopic matrix elements of Hawking radiation. This suggests strong interior dynamics are important for understanding evaporating black holes, without any ensemble average. In this concrete model the density matrix of the radiation deviates from the thermal state, small off-diagonal fluctuations encode equivalences between naively orthogonal states, and bound the entropy from above. For almost evaporated black holes the off-diagonal terms become as large as the diagonal ones, eventually giving a pure state. We also find the unique analytic formula for all Renyi entropies.

2D gravity↗

Super-Maxwellian helium evaporation from pure and salty water

Helium atoms evaporate from pure water and salty solutions in super-Maxwellian speed distributions, as observed experimentally and modeled theoretically. The experiments are performed by monitoring the velocities of dissolved He atoms that evaporate from microjets of pure water at 252 K and 4–8.5 molal LiCl and LiBr at 232–252 K. The average He atom energies exceed the flux-weighted Maxwell-Boltzmann average of 2RT by 30% for pure water and 70% for 8.5m LiBr. Classical molecular dynamics simulations closely reproduce the observed speed distributions and provide microscopic insight into the forces that eject the He atoms from solution. Comparisons of the density profile and He kinetic energies across the water-vacuum interface indicate that the He atoms are accelerated by He–water collisions within the top 1-2 layers of the liquid. We also find that the average He atom kinetic energy scales with the free energy of solvation of this sparingly soluble gas. This free-energy difference reflects the steeply decreasing potential of mean force on the He atoms in the interfacial region, whose gradient is the repulsive force that tends to expel the atoms. The accompanying sharp decrease in water density suppresses the He–water collisions that would otherwise maintain a Maxwell-Boltzmann distribution, allowing the He atom to escape at high energies. Helium is especially affected by this reduction in collisions because its weak interactions make energy transfer inefficient.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaporative cooling of microscopic water droplets in vacuo : Molecular dynamics simulations and kinetic gas theory

In the present study, we investigate the process of evaporative cooling of nanometer-sized droplets in vacuum using molecular dynamics simulations with the TIP4P/2005 water model. The results are compared to the temperature evolution calculated from the Knudsen theory of evaporation which is derived from kinetic gas theory. The calculated and simulation results are found to be in very good agreement for an evaporation coefficient equal to unity. Lastly, our results are of interest to experiments utilizing droplet dispensers as well as to cloud micro-physics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MEASUREMENTS OF NON-THERMAL LINE WIDTHS IN SOLAR ACTIVE REGIONS

Spectral line widths are often observed to be larger than can be accounted for by thermal and instrumental broadening alone. This excess broadening is a key observational constraint for both nanoflare and wave dissipation models of coronal heating. Here we present a survey of non-thermal velocities measured in the high temperature loops (1–4 MK) often found in the cores of solar active regions. This survey of Hinode Extreme Ultraviolet Imaging Spectrometer (EIS) observations covers 15 non-flaring active regions that span a wide range of solar conditions. We find relatively small non-thermal velocities, with a mean value of 17.6 ± 5.3 km s{sup −1}, and no significant trend with temperature or active region magnetic flux. These measurements appear to be inconsistent with those expected from reconnection jets in the corona, chromospheric evaporation induced by coronal nanoflares, and Alfvén wave turbulence models. Furthermore, because the observed non-thermal widths are generally small, such measurements are difficult and susceptible to systematic effects.

79 ASTRONOMY AND ASTROPHYSICS↗

Observational limits on Gauss-Bonnet and Randall-Sundrum gravities

We discuss the possibilities of experimental search for the new physics predicted by the Gauss-Bonnet and the Randall-Sundrum theories of gravity. The effective four-dimensional spherically symmetrical solutions of these theories are analyzed. We consider these solutions in the weak-field limit and in the process of the primordial black hole evaporation. We show that the predictions of the discussed models are the same as of general relativity. Hence, current experiments are not applicable for such search, and therefore different methods of observation and higher accuracy are required.

79 ASTRONOMY AND ASTROPHYSICS↗

The origin of water vapor rings in tropical oceanic cold pools

Tropical deep convection over the ocean is found to grow preferentially from thermodynamically preconditioned regions of high specific humidity and, thus, high moist static energy. Because of this, rings of enhanced specific humidity at the leading edges of evaporatively driven cold pools have recently received considerable attention. The prevailing theory explains these rings by the water vapor source from the evaporation of rain drops below cloud base. Their origin is reported on in this letter using large-eddy simulations of individual cumulus clouds that rise into a tropical atmosphere over ocean. It is demonstrated that - in contrast to this theory - water vapor rings are primarily explained by surface latent heat fluxes rather than by the evaporation of rain. This result implies that conceptual models used in subgrid-scale parameterizations of deep convection should consider the formation of rings of increased specific humidity by the cold-pool-induced enhancement of surface fluxes.

54 ENVIRONMENTAL SCIENCES↗

Simple device modification simultaneously enhances indoor passive evaporative cooling power and duration

Passive evaporative cooling from a damp cloth or vessel can be used for localized cooling of perishables such as food and medicine, drinking water, and even people. Such applications have two key objectives, which are normally in tension with each other: minimizing the water consumption rate and maximizing the cooling (steady-state temperature swing between the cool cloth and the warm surroundings). Here, we present a simple device that delivers higher performance in both metrics simultaneously by adding a perforated aluminum foil sheet suspended over a stagnant air layer to thermally shield the evaporating surface while also facilitating mass transfer. Experimental results demonstrate a simultaneous 10%–25% increase in temperature swing and 2–3× reduction in water consumption rate as compared to conventional evaporative cooling. This improvement is achieved through careful modeling to optimize the coupled heat and mass transfer through the airgap (thermally insulating and vapor permeable) and perforated foil (infrared reflective and vapor permeable).

Chen, Sarah Mizuno↗

Floods of Egypt’s Nile in the 21st century

Extreme precipitation and flooding events are rising globally, necessitating a thorough understanding and sustainable management of water resources. One such setting is the Nile River’s source areas, where high precipitation has led to the filling of Lake Nasser (LN) twice (1998–2003; 2019–2022) in the last two decades and the diversion of overflow to depressions west of the Nile, where it is lost mainly to evaporation. Using temporal satellite-based data, climate models, and continuous rainfall-runoff models, we identified the primary contributor to increased runoff that reached LN in the past two decades and assessed the impact of climate change on the LN’s runoff throughout the twenty-first century. Findings include: (1) the Blue Nile subbasin (BNS) is the primary contributor to increased downstream runoff, (2) the BNS runoff was simulated in the twenty-first century using a calibrated (1965–1992) rainfall-runoff model with global circulation models (GCMs), CCSM4, HadGEM3, and GFDL-CM4.0, projections as model inputs, (3) the extreme value analysis for projected runoff driven by GCMs’ output indicates extreme floods are more severe in the twenty-first century, (4) one adaptation for the projected twenty-first century increase in precipitation (25–39%) and flood (2%-20%) extremes is to recharge Egypt’s fossil aquifers during high flood years.

Climate change↗

The implications of future climate change on the blue water footprint of hydropower in the contiguous US

As the largest renewable energy source, hydropower is essential to the sustainability of the global energy market. However, a considerable amount of water can be lost in the form of evaporation from the associated multipurpose reservoirs, and hence enlarge the blue water footprint (BWF) of hydropower in a warming climate. To facilitate the sustainable management of both water and energy resources under the impact of climate change in the contiguous United States (CONUS), the BWF values of 143 major multipurpose reservoirs were evaluated during the historical period (1985–2014) and two future periods (2020–2049 and 2070–2099). The historical reservoir evaporation loss was calculated using the Landsat-based reservoir surface area and a new evaporation rate algorithm that considers the heat storage effect. Future projections of runoff availability, hydropower generation, and reservoir evaporation were estimated based on the downscaled climate model ensemble from phase 5 of the Coupled Model Intercomparison Project (CMIP5). It was found that the BWF for the CONUS is highly spatially heterogeneous, with an average value of 26.2 m 3 /MWh in the historical period. In the future, the BWF values are projected to increase under both Representative Concentration Pathway (RCP) 4.5 and 8.5 scenarios. This is especially noticeable under RCP 8.5, which has an average BWF value of 30.2 m 3 /MWh for 2070–2099 (increasing by 15.3% from 26.2 m 3 /MWh). The uncertainty ranges increase even more, from 3.4 m 3 /MWh during 2020–2049 to 5.7 m 3 /MWh during 2070–2099. These findings can benefit water and energy resources management in identifying suitable environmental, economic, operational, and investment strategies for multipurpose reservoirs in a changing environment.

13 HYDRO ENERGY↗