Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electron Beam Collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Conjugate echoes of artificially injected electron beams detected optically by means of new image processing

Artificial auroral streaks were detected following two upward injections of energetic electrons (38 keV and 26 keV) from the Echo 4 rocket-borne electron accelerator. Newly developed image processing techniques are used to detect and describe the streaks. It is found that the potential of the payload remained below 1 kV during 45 mA injections at an altitude of 210 km. The echo streaks show little dispersion in time or space, suggesting that the portion of the beam returning to the northern hemisphere loss cone remained collimated and nearly monoenergetic. There was, however, a 70 percent loss in the return flux. The causes of this loss are discussed.

Hallinan, Thomas J.↗

SU-E-T-291: Sensitivity of a Simple 2D EPID in Vivo Dosimetry

Purpose: As radiotherapy (RT) increases in complexity, so does motivation for in vivo dosimetry (IVD), which may detect errors such as: setup, beam shaping and dose delivered. We have recently developed an easy-toimplement method for two-dimensional IVD based on images taken with the electronic portal imaging device (EPID) in cine mode during treatment. The purpose of this work is to characterize its sensitivity to possible RT delivery errors. Methods: We introduced a series of modifications to a simple RT field (10×10, 100MU, 300RR, 20cm homogeneous phantom) to simulate errors. These modifications included multi-leaf collimator (MLC) position, number of MUs, and collimator angle. We quantified the sensitivity to inhomogeneities by inserting variable amounts of solid lung and bone. Finally we delivered realistic fields to an anthropomorphic phantom to estimate sensitivity to gantry angle and setup errors. Results: Our EPIDIVD is sensitive to MLC positioning errors of 1mm and 3mm in the closed and open directions respectively, and to 3% MU variations. Sensitivity to collimator angle depends on field shape irregularity; in the case of a 10x10 field, we are sensitive to errors of 0.8°. The sensitivity to inhomogeneities is limited by the nature of MV imaging: approximately 1% signal change is noted when switching 5cm of water to equal amounts of bone or lung. This suggests that the EPID-IVD is likely not sensitive to small setup or gantry angle errors, as confirmed by anthropomorphic tests. Conclusion: We have characterized a simple method of 2D dose reconstruction at isocenter depth inside the patient, which is sensitive to possible RT delivery errors. This method may be useful as a secondary safety check, to prevent large errors from being carried on to following fractions, and to record delivered dose. By using readily available hardware, it is easily implemented and may prove especially useful in centers with limited resources.

60 APPLIED LIFE SCIENCES↗

Common path point diffraction interferometer using liquid crystal phase shifting

A common path point diffraction interferometer uses dyed, parallel nematic liquid crystals which surround an optically transparent microsphere. Coherent, collimated and polarized light is focused on the microsphere at a diameter larger than that of the microsphere. A portion of the focused light passes through the microsphere to form a spherical wavefront reference beam and the rest of the light is attenuated by the dyed liquid crystals to form an object beam. The two beams form an interferogram which is imaged by a lens onto an electronic array sensor and into a computer which determines the wavefront of the object beam. The computer phase shifts the interferogram by stepping up an AC voltage applied across the liquid crystals without affecting the reference beam.

Mercer, Carolyn R.↗

Statistical simulation of multiple Compton backscattering process

A number of laboratories are currently developing monochromatic sources of X-rays and gamma quanta based on the Compton backscattering (CBS) of laser photons by relativistic electrons. Modern technologies are capable of providing a concentration of electrons and photons in the interaction point such that each primary electron can emit several hard photons. In contrast to the well-known nonlinear CBS process, in which an initial electron “absorbs” a few laser photons and emits a single hard one, the above-mentioned process can be called a multiple CBS process and is characterized by a mean number of emitted photons. The present paper is devoted to simulating the parameters of a beam of back scattered quanta based on the Monte Carlo technique. It is shown that, even in the case of strong collimation of a resulting photon beam, the radiation monochromaticity may deteriorate because of the contribution coming from the multiple photon emission, which is something that must be considered while designing new CBS sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Top-off Safety Analysis for XFP (17BM) Beamline

The purpose of this report is to analyze the top off safety of XFP beamline, which was not covered by the top off design report issued in 2014. XFP beamline has a mirror in front end (FE) to provide a vertical offset on the ratchet wall collimator aperture. This report will only be used as a basis to approve the topoff operation of XFP beamline. The topoff operation of new beamlines and the approval process is guarded by procedure PS-C-ASD-PRC-183. The primary radiological safety concern for the top-off injection, with the FE safety shutters open, is the scenario where injected electrons could be conveyed down to the beam line through the front end. With the mirror offset, the electrons can never escape FE to reach the first optical enclosure (FOE). So the worst scenario will be the electrons propagating to farthest downstream in FE, and the radiological effect of this fault condition is discussed in this note.

36 MATERIALS SCIENCE↗

Laser-driven collimated tens-GeV monoenergetic protons from mass-limited target plus preformed channel

Proton acceleration by ultra-intense laser pulse irradiating a target with cross-section smaller than the laser spot size and connected to a parabolic density channel is investigated. The target splits the laser into two parallel propagating parts, which snowplow the back-side plasma electrons along their paths, creating two adjacent parallel wakes and an intense return current in the gap between them. The radiation-pressure pre-accelerated target protons trapped in the wake fields now undergo acceleration as well as collimation by the quasistatic wake electrostatic and magnetic fields. Particle-in-cell simulations show that stable long-distance acceleration can be realized, and a 30 fs monoenergetic ion beam of >10 GeV peak energy and <2 Degree-Sign divergence can be produced by a circularly polarized laser pulse at an intensity of about 10{sup 22} W/cm{sup 2}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electronic Absolute Cartesian Autocollimator

An electronic absolute Cartesian autocollimator performs the same basic optical function as does a conventional all-optical or a conventional electronic autocollimator but differs in the nature of its optical target and the manner in which the position of the image of the target is measured. The term absolute in the name of this apparatus reflects the nature of the position measurement, which, unlike in a conventional electronic autocollimator, is based absolutely on the position of the image rather than on an assumed proportionality between the position and the levels of processed analog electronic signals. The term Cartesian in the name of this apparatus reflects the nature of its optical target. Figure 1 depicts the electronic functional blocks of an electronic absolute Cartesian autocollimator along with its basic optical layout, which is the same as that of a conventional autocollimator. Referring first to the optical layout and functions only, this or any autocollimator is used to measure the compound angular deviation of a flat datum mirror with respect to the optical axis of the autocollimator itself. The optical components include an illuminated target, a beam splitter, an objective or collimating lens, and a viewer or detector (described in more detail below) at a viewing plane. The target and the viewing planes are focal planes of the lens. Target light reflected by the datum mirror is imaged on the viewing plane at unit magnification by the collimating lens. If the normal to the datum mirror is parallel to the optical axis of the autocollimator, then the target image is centered on the viewing plane. Any angular deviation of the normal from the optical axis manifests itself as a lateral displacement of the target image from the center. The magnitude of the displacement is proportional to the focal length and to the magnitude (assumed to be small) of the angular deviation. The direction of the displacement is perpendicular to the axis about which the mirror is slightly tilted. Hence, one can determine the amount and direction of tilt from the coordinates of the target image on the viewing plane.

Leviton, Douglas B.↗

Collimated protons accelerated from an overdense gas jet irradiated by a 1 µm wavelength high-intensity short-pulse laser

We have investigated proton acceleration in the forward direction from a near-critical density hydrogen gas jet target irradiated by a high intensity (10 18 W/cm 2 ), short-pulse (5 ps) laser with wavelength of 1.054 μm. We observed the signature of the Collisionless Shock Acceleration mechanism, namely quasi-monoenergetic proton beams with small divergence in addition to the more commonly observed electron-sheath driven proton acceleration. The proton energies we obtained were modest (~MeV), but prospects for improvement are offered through further tailoring the gas jet density profile. Also, we observed that this mechanism is very robust in producing those beams and thus can be considered as a future candidate in laser-driven ion sources driven by the upcoming next generation of multi-PW near-infrared lasers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling the TrueBeam linac using a CAD to Geant4 geometry implementation: Dose and IAEA-compliant phase space calculations

Purpose: To create an accurate 6 MV Monte Carlo simulation phase space for the Varian TrueBeam treatment head geometry imported from cad (computer aided design) without adjusting the input electron phase space parameters. Methods: geant4 v4.9.2.p01 was employed to simulate the 6 MV beam treatment head geometry of the Varian TrueBeam linac. The electron tracks in the linear accelerator were simulated with Parmela, and the obtained electron phase space was used as an input to the Monte Carlo beam transport and dose calculations. The geometry components are tessellated solids included in geant4 as gdml (generalized dynamic markup language) files obtained via STEP (standard for the exchange of product) export from Pro/Engineering, followed by STEP import in Fastrad, a STEP-gdml converter. The linac has a compact treatment head and the small space between the shielding collimator and the divergent arc of the upper jaws forbids the implementation of a plane for storing the phase space. Instead, an IAEA (International Atomic Energy Agency) compliant phase space writer was implemented on a cylindrical surface. The simulation was run in parallel on a 1200 node Linux cluster. The 6 MV dose calculations were performed for field sizes varying from 4 x 4 to 40 x 40 cm{sup 2}. The voxel size for the 60x60x40 cm{sup 3} water phantom was 4x4x4 mm{sup 3}. For the 10x10 cm{sup 2} field, surface buildup calculations were performed using 4x4x2 mm{sup 3} voxels within 20 mm of the surface. Results: For the depth dose curves, 98% of the calculated data points agree within 2% with the experimental measurements for depths between 2 and 40 cm. For depths between 5 and 30 cm, agreement within 1% is obtained for 99% (4x4), 95% (10x10), 94% (20x20 and 30x30), and 89% (40x40) of the data points, respectively. In the buildup region, the agreement is within 2%, except at 1 mm depth where the deviation is 5% for the 10x10 cm{sup 2} open field. For the lateral dose profiles, within the field size for fields up to 30x30 cm{sup 2}, the agreement is within 2% for depths up to 10 cm. At 20 cm depth, the in-field maximum dose difference for the 30x30 cm{sup 2} open field is within 4%, while the smaller field sizes agree within 2%. Outside the field size, agreement within 1% of the maximum dose difference is obtained for all fields. The calculated output factors varied from 0.938{+-}0.015 for the 4x4 cm{sup 2} field to 1.088{+-}0.024 for the 40x40 cm{sup 2} field. Their agreement with the experimental output factors is within 1%. Conclusions: The authors have validated a geant4 simulated IAEA-compliant phase space of the TrueBeam linac for the 6 MV beam obtained using a high accuracy geometry implementation from cad. These files are publicly available and can be used for further research.

43 PARTICLE ACCELERATORS↗

Search for dark matter decaying to two displaced muons produced in proton-proton collisions at 13 TeV with the CMS detector, and for dark photons produced in electron-positron fixed-target collisions at 500 MeV with the PADME detector

Two novel searches for dark matter using particle accelerators are presented. The first is a search for inelastically-coupled dark matter with the CMS detector at CERN, relying on 137 fb$^{-1}$ of proton-proton collision data collected at 13 TeV center-of-mass energy between 2016 and 2018. The search strategy exploits the striking signature expected of inelastic dark matter: a pair of displaced, soft, and narrow muons collimated with missing transverse momentum and recoiled off an initial-state radiation jet. This is the first search for inelastic dark matter at a hadron collider. The second experiment is PADME, a small-scale detector to search for dark photons located in Frascati, Italy. PADME seeks to detect the production of dark photons in positron-electron collisions with a stationary diamond target and a 500 MeV positron beam. The missing-mass technique employed in the experiment relies on constraining all four-momenta in the system except for the dark photon and lookin g for a bump in the resulting invariant mass distribution corresponding to the dark photon's mass. The projected sensitivity for both experiments is compared in the context of highlighting the need for a comprehensive experimental search program for dark matter. Both analyses expect first public results by the end of 2020.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

HH 1158: THE LOWEST LUMINOSITY EXTERNALLY IRRADIATED HERBIG–HARO JET

We have identified a new externally irradiated Herbig–Haro (HH) jet, HH 1158, within ∼2 pc of the massive OB type stars in the σ Orionis cluster. At an L{sub bol} ∼ 0.1 L{sub ⊙}, HH 1158 is the lowest luminosity irradiated HH jet identified to date in any cluster. Results from the analysis of high-resolution optical spectra indicate asymmetries in the brightness, morphology, electron density, velocity, and the mass outflow rates for the blue and redshifted lobes. We constrain the position angle of the HH 1158 jet at 102° ± 5°. The mass outflow rate and the mean accretion rate for HH 1158 using multiple diagnostics are estimated to be (5.2 ± 2.6) × 10{sup −10} M{sub ⊙} yr{sup −1} and (3.0 ± 1.0) × 10{sup −10} M{sub ⊙} yr{sup −1}, respectively. The properties for HH 1158 are notably similar to the externally irradiated HH 444–HH 447 jets previously identified in σ Orionis. In particular, the morphology is such that the weaker jet beam is tilted toward the massive stars, indicating a higher extent of photo-evaporation. The high value for the Hα/[S ii] ratio is also consistent with the ratios measured in other irradiated jets, including HH 444–HH 447. The presence of an extended collimated jet that is bipolar and the evidence of shocked emission knots make HH 1158 the first unique case of irradiated HH jets at the very low-luminosity end, and provides an opportunity to learn the physical properties of very faint HH jet sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of fast electron jet produced from interaction of intense laser beam with solid target at oblique incidence

Fast electrons generated along target normal direction from the interaction of intense ultrashort Ti:sapphire laser pulses ({lambda}{sub 0} = 800 nm) with planar copper target at 45 Degree-Sign incidence angle have been experimentally studied under different interaction conditions. Angular spread and energy spectrum of the fast electrons was measured for both p- and s-polarized laser irradiation at intensities in the range 4 Multiplication-Sign 10{sup 16}- 4 Multiplication-Sign 10{sup 17} W/cm{sup 2} (for a fixed pulse duration of 45 fs) and for pulse duration in the range 45 fs-1.2 ps (for a fixed laser fluence of 1.8 Multiplication-Sign 10{sup 4} J/cm{sup 2}). The fast electrons were observed consistently along the target normal direction over the entire range of interaction conditions in the form of a collimated jet, within a half cone angle of 20 Degree-Sign . The fast electrons have continuous energy spectrum with effective temperature 290 keV and 160 keV, respectively, for p- and s-polarized 45 fs laser pulse irradiation at intensity 4 Multiplication-Sign 10{sup 17} W/cm{sup 2}. Scaling laws for temperature of fast electrons with laser intensity and pulse duration were obtained. The experimental results have been explained on the basis of laser absorption and fast electron generation through the resonance absorption mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance Verification of the Gravity and Extreme Magnetism Small Explorer GEMS X-Ray Polarimeter

olarimetry is a powerful tool for astrophysical observations that has yet to be exploited in the X-ray band. For satellite-borne and sounding rocket experiments, we have developed a photoelectric gas polarimeter to measure X-ray polarization in the 2-10 keV range utilizing a time projection chamber (TPC) and advanced micro-pattern gas electron multiplier (GEM) techniques. We carried out performance verification of a flight equivalent unit (1/4 model) which was planned to be launched on the NASA Gravity and Extreme Magnetism Small Explorer (GEMS) satellite. The test was performed at Brookhaven National Laboratory, National Synchrotron Light Source (NSLS) facility in April 2013. The polarimeter was irradiated with linearly-polarized monochromatic X-rays between 2.3 and 10.0 keV and scanned with a collimated beam at 5 different detector positions. After a systematic investigation of the detector response, a modulation factor greater than or equal to 35% above 4 keV was obtained with the expected polarization angle. At energies below 4 keV where the photoelectron track becomes short, diffusion in the region between the GEM and readout strips leaves an asymmetric photoelectron image. A correction method retrieves an expected modulation angle, and the expected modulation factor, approximately 20% at 2.7 keV. Folding the measured values of modulation through an instrument model gives sensitivity, parameterized by minimum detectable polarization (MDP), nearly identical to that assumed at the preliminary design review (PDR).

Time Projection↗

Geometry Survey of the Time-of-Flight Neutron-Elastic Scattering (Antonella) Experiment

The Antonella experiment is a measurement of the ionization efficiency of nuclear recoils in silicon at low energies [1]. It is a neutron elastic scattering experiment motivated by the search for dark matter particles. In this experiment, a proton beam hits a lithium target and neutrons are produced. The neutron shower passes through a collimator that produces a neutron beam. The beam illuminates a silicon detector. With a certain probability, a neutron interacts with a silicon nucleus of the detector producing elastic scattering. After the interaction, a fraction of the neutron energy is transferred to the silicon nucleus which acquires kinetic energy and recoils. This kinetic energy is then dissipated in the detector producing ionization and thermal energy. The ionization produced is measured with the silicon detector electronics. On the other hand, the neutron is scattered out of the beam. A neutron-detector array (made of scintillator bars) registers the neutron arrival time and the scattering angle to reconstruct the kinematics of the neutron-nucleus interaction with the time-of-flight technique [2]. In the reconstruction equations, the energy of the nuclear recoil is a function of the scattering angle with respect to the beam direction, the time-of-flight of the neutron and the geometric distances between components of the setup (neutron-production target, silicon detector, scintillator bars). This paper summarizes the survey of the different components of the experiment that made possible the off-line analysis of the collected data. Measurements were made with the API Radian Laser Tracker and I-360 Probe Wireless. The survey was completed at the University of Notre Dame, Indiana, USA in February 2015.

Oshinowo, Babatunde O.↗

Collimation study for LCLS

In this study we investigate the power deposition along the undulator section of the SLAC Linac Coherent Light Source (LCLS) due to the primary e¯ -beam but also due to potential secondary particles. The expected beam distribution after the LCLS injector is deliberately broadened as an approximated representation of the beam halo. Secondary particles, as e + , e¯ and photons, are generated as a result of tracking the intercepted beam through a dense material. This process is carried out by means of GEANT-4, which has been convoluted into our main tracking engine, LUCRETIA. Simulations show no losses along the undulator section when assuming the nominal primary beam and collimator gaps. However when opening the gaps of collimators located at the first collimator section, by 25%, the fattened beam is partially intercepted by the second collimator section, which is aligned to the undulators. Secondary particles, mostly photons generated at the second collimator section, deposit their energy along the undulator section, at a rate of the order of a milliwatt.

43 PARTICLE ACCELERATORS↗

CMS Pixel Telescope Addition to T-980 Bent Crystal Collimation Experiment at the Tevatron

An enhancement to the T-980 bent crystal collimation experiment at the Tevatron has been completed. The enhancement was the installation of a pixel telescope inside the vacuum-sealed beam pipe of the Tevatron. The telescope is comprised of six CMS PSI46 pixel plaquettes, arranged as three stations of horizontal and vertical planes, with the CAPTAN system for data acquisition and control. The purpose of the pixel telescope is to measure beam profiles produced by bent crystals under various conditions. The telescope electronics inside the beam pipe initially were not adequately shielded from the image current of the passing beams. A new shielding approach was devised and installed, which resolved the problem. The noise issues encountered and the mitigating techniques are presented herein, as well as some preliminary results from the telescope.

43 PARTICLE ACCELERATORS↗

Bulk and integrated acousto-optic spectrometers for molecular astronomy with heterodyne spectrometers

A survey of acousto-optic spectrometers for molecular astronomy is presented, noting a technique of combining the acoustic bending of a collimated coherent light beam with a Bragg cell followed by an array of sensitive photodetectors. This acousto-optic spectrometer has a large bandwidth, a large number of channels, high resolution, and is energy efficient. Receiver development has concentrated on high-frequency heterodyne systems for the study of the chemical composition of the interstellar medium. RF spectrometers employing acousto-optic diffraction cells are described. Acousto-optic techniques have been suggested for applications to electronic warfare, electronic countermeasures and electronic support systems. Plans to use integrated optics for the further miniaturization of acousto-optic spectrometers are described. Bulk acousto-optic spectrometers with 300 MHz and 1 GHz bandwidths are being developed for use in the back-end of high-frequency heterodyne receivers for astronomical research.

Chin, G.↗

Instruments for Reading Direct-Marked Data-Matrix Symbols

Improved optoelectronic instruments (specially configured digital cameras) for reading direct-marked data-matrix symbols on the surfaces of optically reflective objects (including specularly reflective ones) are undergoing development. Data-matrix symbols are two-dimensional binary patterns that are used, like common bar codes, for automated identification of objects. The first data-matrix symbols were checkerboard-like patterns of black-and-white rectangles, typically existing in the forms of paint, ink, or detachable labels. The major advantage of direct marking (the marks are more durable than are painted or printed symbols or detachable labels) is offset by a major disadvantage (the marks generated by some marking methods do not provide sufficient contrast to be readable by optoelectronic instruments designed to read black-and-white data-matrix symbols). Heretofore, elaborate lighting, lensing, and software schemes have been tried in efforts to solve the contrast problem in direct-mark matrix- symbol readers. In comparison with prior readers based on those schemes, the readers now undergoing development are expected to be more effective while costing less. All of the prior direct-mark matrix-symbol readers are designed to be aimed perpendicularly to marked target surfaces, and they tolerate very little angular offset. However, the reader now undergoing development not only tolerates angular offset but depends on angular offset as a means of obtaining the needed contrast, as described below. The prototype reader (see Figure 1) includes an electronic camera in the form of a charge-coupled-device (CCD) image detector equipped with a telecentric lens. It also includes a source of collimated visible light and a source of collimated infrared light for illuminating a target. The visible and infrared illumination complement each other: the visible illumination is more useful for aiming the reader toward a target, while the infrared illumination is more useful for reading symbols on highly reflective surfaces. By use of beam splitters, the visible and infrared collimated lights are introduced along the optical path of the telecentric lens, so that the target is illuminated and viewed from the same direction.

Schramm, Harry F.↗