At least 397 records · Page 22

Sustainable Energy Solutions for Thermal Load in Buildings—Role of Heat Pumps, Solar Thermal, and Hydrogen-Based Cogeneration Systems

Economic and population growth is leading to increased energy demand across all sectors—buildings, transportation, and industry. Adoption of new energy consumers such as electric vehicles could further increase this growth. Sensible utilization of clean renewable energy resources is necessary to sustain this growth. Thermal needs in a building pose a significant challenge to the energy infrastructure. Potential technological solutions to address growing energy demand while simultaneously lowering the carbon footprint and enhancing the grid flexibility are presented in this study. Performance assessment of heat pumps, solar thermal collectors, nonfossil fuel-based cogeneration systems, and their hybrid configurations is reported in this study. The impact of design configuration, coefficient of performance (COP), electric grid’s primary energy efficiency on the key attributes of total carbon footprint, life cycle costs, operational energy savings, and site-specific primary energy efficiency are analyzed and discussed in detail. In conclusion, heat pumps and hydrogen-fueled solid oxide fuel cells (SOFCs) are highly effective building energy resources compared to traditional approaches; however, the carbon intensity of electrical energy and hydrogen production are keys to the overall environmental benefit.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Kiana RACEE Reductions Template v2

Energy savings data from Remote Alaska Communities Energy Efficiency (RACEE) competition

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Load Profiles for the U.S. Building Stock: Practical Guidance on Accessing and Using the Data

End-use load profiles (EULP), which quantify how and when energy is used, are critically important to utilities, public utility commissions, state energy offices, and other stakeholders. Applications of EULPs focus on understanding how efficiency, demand response, and other distributed energy resources are valued and used in R&D prioritization, utility resource and distribution system planning, and state and local energy planning and regulations. Consequently, high-quality EULPs are critical for widespread adoption of electrification, demand flexibility, and grid-interactive efficient buildings. For example, EULPs can be used to forecast energy savings in buildings or to identify energy using activities that can be shifted to different times of the day.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Retrofitting Buildings with Solar-Reflective Roofs and Walls and its Impact on Peak Power Demand

Buildings are a major consumer of electricity in the United States and a significant portion of the consumption comes from heating, ventilation, and air-conditioning (HVAC) applications. Passive cooling strategies in the building envelope help to reduce the energy consumption for HVAC as well as peak electricity demand. Although being one of the most cost-effective passive cooling strategies, modern reflective roofing and reflective exterior wall technology is not well documented for its impact on peak demand. This study utilized whole building energy simulations on residential and commercial building prototype models to quantify the impact of cool roofs and cool exterior walls. The analysis was performed in three climate zones with varying insulation levels and solar reflectances for roofs and exterior walls. For both the residential and commercial buildings, the baseline building had a roof solar reflectance value of 0.10 and an exterior wall solar reflectance value of 0.25. The results from the simulations show that roofs and exterior walls with higher reflectance values increase cooling energy savings but can also increase heating energy consumption. The impact of changes in solar reflectances was greater in buildings with low roof/wall insulation levels compared to roofs/walls with higher insulation levels. A baseline for the simulations was set with the roof and exterior wall solar reflectances set at 0.1 and 0.25, respectively and simulations having varying roof and exterior wall thermal resistances were compared to the baselines.

14 SOLAR ENERGY↗

Determining Price Reasonableness in Energy Performance Contracts

Report provides recommendations and best practices concerning fair and reasonable price determination in federal energy performance contracts (EPCs), which include energy savings performance contracts (ESPCs) and utility energy service contracts (UESCs). It reflects the experiences, lessons learned, and best practices of agencies implementing EPCs, and is consistent with FEMP’s training on this subject. This is an update to the 2015 revision.

Dominy, Russ [Boston Government Services (BGS)]↗

Exploring the Limits of Cooling for Extreme Heat Flux Applications: Data Centers and Power Electronic

We developed an Extreme Heat Flux Micro-cooler (EHFµ-C) capable of removing heat flux of ~1 kW/cm 2 with a small temperature rise ~10°C. This represents greater than 10× reduction in thermal resistance compared to the state-of-the-art single-phase cooling technologies (~0.5 cm 2 -°C/W) that greatly increases the efficiency, resulting in improved performance and reliability for microprocessors and power electronics. The EHFµ-Cooler utilizes liquid wicking (no pump) and thin-film evaporation in a 30 µm thick wick porous microstructure such as copper inverse opal (CIO), silicon and AlN pin fins along with a 3D manifold (copper wiremesh and silicon) with liquid routing and vapor extraction channels achieving an unprecedented vapor quality ~ >0.9. The proposed EHFµ-Cooler significantly reduces device temperature, resulting in 25-50% improvement in reliability and device performance. Based on very conservative estimates, the total energy saving for data centers due to improved performance can be 6 billion kWh/year (>$300M). Better cooling, leading to more efficient, higher performance and more reliable power electronics, would save the nation 3 Quad of primary energy in 2030. Just for automotive application, a 10% increase in fuel efficiency for SiC-based power electronics equates to >20 million gallons of fuel savings annually. The proposed EHFµ-Cooler technology ensures the United States maintains its technological lead in high-performance computing and high-power electronics, while at the same time improving the energy efficiency, and as a result reducing energy-related emissions such as greenhouse gases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The value of integrating a geothermal district heating system into a microgrid

As electrical grids increasingly rely on variable renewable energy, maintaining reliability and cost efficiency becomes more complex. To address these challenges, this study analyzed the integration of geothermal district heating as a grid-responsive thermal resource within a microgrid in Tuttle, Oklahoma. Building energy modeling using EnergyPlus estimated annual district heating demand at 2.9 GWh, with a peak load of 2.8 MW th . Techno-economic analyses were conducted to meet the heating demand under three geothermal scenarios, varying by production depth, flow rate, and thermal output, each supplemented by natural gas peaking boilers. In parallel, equivalent electrical load profiles were developed using typical coefficients of performance (COPs) for air-source heat pumps and electric boilers to establish an electrified baseline scenario. A complete end-use electrical load profile was also developed for the microgrid using Cambium dataset. The modeling results demonstrated reliable and economic operation of the geothermal systems over 30 years, with COPs ranging from 2.6 to 8.9 and the lowest levelized heating cost at $\$$54.6/MWh. Geothermal integration reduced electricity consumption by up to 94.7 % compared to the non-geothermal base case, yielding annual energy savings of up to $\$$803 k. Avoided grid costs ranged from $\$$65 k–$\$$147 k per year, with individual events avoiding up to $\$$4,863 per hour. Grid-responsive operation further reduced wholesale energy costs by 53–56 %. These findings demonstrate geothermal heating, traditionally treated as a non-grid-responsive thermal resource, can be reconfigured to support dynamic grid services, offering a scalable pathway to enhance reliability and reduce costs in renewable-rich microgrids and district heating networks.

15 GEOTHERMAL ENERGY↗

Cloud-based implementation of white-box model predictive control for a GEOTABS office building: A field test demonstration

Model predictive control (MPC) has been proven in simulations and pilot case studies to be a superior control strategy for large buildings. MPC can utilize the weather and occupancy schedule forecasts, together with the system model, to predict the future thermal behavior of the building and minimize the overall energy use and maximize thermal comfort. However, these advantages come with the cost of increased modeling effort, computational demands, communication infrastructure, and commissioning efforts. Thus a typical approach is to, often rapidly, simplify the building modeling and MPC optimization problem while paying a price of not reaching the full performance potential. It has been shown that by employing accurate physics-based models, MPC performance can be notably increased closer to its theoretical performance bound. However, implementation of such high-fidelity MPC in real buildings remains a challenge, resulting in a lack of successful field test studies. This work presents the methodology and field test demonstration of a computationally efficient implementation of the white-box MPC in an office building in Belgium. The detailed model of the building is based on first-principle physical equations. The deployment and supervision of MPC operation in a practical setting are supported by an automated cloud-based communication infrastructure. The motivating factor behind the cloud-based architecture is its compatibility with a commercially appealing control as a service concept. The building is equipped with a ground source heat pump (GSHP) and thermally activated building structures (TABS), where the combination of both is also known as GEOTABS. From a control perspective, GEOTABS buildings are particularly challenging systems due to large scale, complex heating, ventilation and air conditioning (HVAC) system, and slow dynamics with time delays. On the other hand, there is an increased potential for energy savings due to the high thermal mass, which acts as thermal storage. The MPC operation is demonstrated during the challenging transient seasons (switching between heating and cooling), and its performance is compared to a traditional rule-based controller (RBC). We provide a proof of concept of real MPC operation for the most difficult seasons with notable GSHP energy use savings equal to 53.5% and thermal comfort improvement by 36.9%. Other MPC applications found in the literature describe tests for only cooling or only heating, and up to now only for a black-box or a grey-box approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long and Winding Road to Higher Efficiency-The RTU Story: Preprint

Rooftop units (RTUs) and other packaged heating, ventilating, and air-conditioning (HVAC) equipment consume more than four quads of energy annually while conditioning more than 50% of the commercial building floor area in the United States. Historically, these systems have low operating efficiencies and receive infrequent maintenance. In addition, the market has a low first cost, run-to-failure, like-for-like replacement mentality and has been slow to adopt change. This paper explores the broad market transformation that has resulted in higher efficiencies and tremendous energy savings. Although there are many factors in this market transformation, this paper highlights: research behind advancements in components and controls; adoption of an operational efficiency metric; raising the bar for high efficiency with the RTU Challenge; market barriers overcome through the Advanced RTU Campaign; upstream and midstream incentive programs and HVAC distribution networks; alignment of the market efficiency drivers of ASHRAE Standard 90.1, federal minimum efficiency standards, the ENERGY STAR® program, and the Consortium for Energy Efficiency's (CEE's) efficiency tiers. Measures of the market transformation include more than 50% increase in RTU efficiencies, more than 1 billion kWh saved and 160,000 RTUs upgraded with high-efficiency measures by the Advanced RTU Campaign partners, large increases of high-efficiency RTUs purchased through incentive programs, and the largest energy savings from any federal minimum standards action. Although these results are impressive, the market transformation is just beginning, and there remain exciting opportunities for improvements in equipment efficiencies and improved operating performance with advanced controls and fault detection and diagnostics.

30 DIRECT ENERGY CONVERSION↗

The Cost of Decarbonization and Energy Upgrade Retrofits for US Homes

Cost is a major barrier when upgrading homes to reduce carbon emissions required to meet DOE’s climate-related goals. This report summarizes a nationwide effort to gather home energy upgrade project cost data along with household energy performance data. The goal was to develop cost benchmarks and to guide future R&D efforts aimed at cost compression and scaling of the residential upgrade market. The cost data were compiled for both total project costs and costs of individual measures. The majority of energy savings were modeled, with some models using measured site data for calibration. The database was analyzed using clustering techniques to find common energy and CO2 reduction approaches. The individual measures were combined into archetypal solutions to determine least-cost approaches to maximizing energy and carbon savings. Several financial analyses were preformed to examine other cost metrics beyond first cost. Project data was obtained for 1,739 projects, from 15 states and 12 energy programs, with a total of 10,512 individual measures. The database includes a wide-array of projects, ranging from single-measure HVAC upgrades to net-zero energy whole home remodels. Projects were predominantly single-family detached dwellings with wood frame construction. Most of the data was obtained from energy programs because they had recorded the necessary information and were willing to share with this study. This sample of convenience can provide broad guidance and national cost benchmarks, but lacks sufficient detail to draw more disaggregated conclusions, such as geographical trends. The majority of data contributions were obtained without compensation from sources where the required data was already in some sort of structured format. We compensated sources to enter data from individual projects into a structured data format for about 500 projects, with an average cost of about $40 per project. The database was highly skewed to lower cost, lower impact projects due to the nature of the sample of convenience. Less than 10% of projects had savings greater than 50%. The cost data for individual measures in the database are being used in other DOE efforts on residential energy use/decarbonization. This data collection effort should continue in order to provide the best-informed guidance for DOE and industry R&D, as well as deployment efforts (including policy and program planning).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Investigation of Remanufacturing Methods Utilizing Mechanically-Generated and Gas-Atomized Feedstock Production for Directed Energy Deposition Processing Through Specific Energy Consumption Modeling

The goal of this work was to assess the energy consumption of a novel remanufacturing method that utilizes mechanically-generated feedstock for directed energy deposition. Gas-atomization is the state-of-the-art production process for directed energy deposition feedstock, and for this work was incorporated into a remanufacturing process path to provide a comparison method. Specific energy consumption models of remanufacturing utilizing both of these proposed process paths were developed and applied to a case study to investigate energy saving opportunities for future manufacturing paradigms. The energy modelling was done in three stages. First, the mechanically-generated feedstock production energy consumption model was generated from experimental observation. Second, the gas-atomized feedstock production energy consumption model was generated from a combination of experimental observation, reported estimates from the manufacturer, and data found in the literature. Lastly, the energy consumption model of directed energy deposition was derived from experimental observation and compares favorably with reported estimates in the literature. With the models, the specific energy consumption in the two process paths were compared and their application was demonstrated by estimating the energy consumption to remanufacture a bracket. The two feedstock production methods had similar specific energy consumptions. The specific energy consumption of the directed energy deposition process was the greatest component in the respective remanufacturing paths by an order of magnitude; increasing deposition rate is the most important factor for lowering the overall specific energy consumption. The analyzed remanufacturing technologies were estimated to consume less energy than replacement when repairing up to approximately 15% of the original part’s mass.

42 ENGINEERING↗

Leveraging inter-firm influence in the diffusion of energy efficiency technologies: An agent-based model

Energy efficiency technologies (EETs) are crucial for saving energy and reducing carbon dioxide emissions. However, the diffusion of EETs in small and medium-sized enterprises is rather slow. Literature shows the interactions between innovation adopters and potential adopters have significant impacts on innovation diffusion. Enterprises lack the motivation to share information, and EETs usually lack observability, which suppress the inter-firm influence. Thus, an information platform, together with proper policies encouraging or forcing enterprises to disclose EET-related information, should help harness inter-firm influence to accelerate EETs' diffusion. To explore whether and how such an information platform affects EETs' diffusion in small and medium-sized enterprises, this report builds an agent-based model to mimic EET diffusion processes. Based on a series of controlled numerical experiments, some counter-intuitive phenomena are discovered and explained. The results show that the information platform is a double-edged sword that notably accelerates EETs' diffusion by approximately 47% but may also boost negative information to diffuse even faster and delay massive adoption of EETs. Increasing network density and the intensity of inter-firm influence are effective to speed EET diffusion, but their impacts diminish drastically after reaching some critical values (0.05 and 0.15 respectively) and eventually harm the stability of the system. Ultimately, the findings implicate that EET suppliers should carefully launch their promising but immature products; policies that can reduce the perceived risk by enterprises and the effort to maintain an informative rather than judgmental information platform can prominently mitigate the negative side effects brought by high fluidity of information.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modelica-based modeling and simulation of district cooling systems: A case study

While equation-based object-oriented modeling language Modelica can evaluate practical energy improvements for district cooling systems, few have adopted Modelica for this type of large-scale thermo-fluid system. Further, to our best knowledge, district cooling modeling studies have yet to include hydraulics in piping networks alongside plant models featuring realistic mechanical systems and controls. These are critical details to include when looking to make energy and control improvements in many physical system installations. To fill these gaps, this study released new open-source district cooling models at the Modelica Buildings Library and leveraged these models for a real-world case study at the University of Colorado Boulder. Here, the site includes six buildings connected to a central chiller plant featuring a waterside economizer. Several energy saving strategies are pursued based on the validated model, including control setpoint optimization, equipment modification, and pump setpoint adjustments. Results indicate that a combination of the studied measures can save the campus annually 84.6 MWh of energy, 8.9% of electricity costs, 58.0 metric tons of carbon dioxide emissions, while the waterside economizer cuts down chillers’ run times by 201 days/year, reducing maintenance costs and extending chiller life.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating cross-sectoral impacts of climate change and adaptations on the energy-water nexus: a framework and California case study

Abstract Electricity and water systems are inextricably linked through water demands for energy generation, and through energy demands for using, moving, and treating water and wastewater. Climate change may stress these interdependencies, together referred to as the energy-water nexus, by reducing water availability for hydropower generation and by increasing irrigation and electricity demand for groundwater pumping, among other feedbacks. Further, many climate adaptation measures to augment water supplies—such as water recycling and desalination—are energy-intensive. However, water and electricity system climate vulnerabilities and adaptations are often studied in isolation, without considering how multiple interactive risks may compound. This paper reviews the fragmented literature and develops a generalized framework for understanding these implications of climate change on the energy-water nexus. We apply this framework in a case study to quantify end-century direct climate impacts on California’s water and electricity resources and estimate the magnitude of the indirect cross-sectoral feedback of electricity demand from various water adaptation strategies. Our results show that increased space cooling demand and decreased hydropower generation are the most significant direct climate change impacts on California’s electricity sector by end-century. In California’s water sector, climate change impacts directly on surface water availability exceed demand changes, but have considerable uncertainty, both in direction and magnitude. Additionally, we find that the energy demands of water sector climate adaptations could significantly affect California’s future electricity system needs. If the worst-case water shortage occurs under climate change, water-conserving adaptation measures can provide large energy savings co-benefits, but other energy-intensive water adaptations may double the direct impacts of climate change on the state’s electricity resource requirement. These results highlight the value of coordinated adaptation planning between the energy and water sectors to achieve mutually beneficial solutions for climate resilience.

54 ENVIRONMENTAL SCIENCES↗

Accelerator Physics Lessons From CBETA, the First Multi-turn SRF ERL

The Cornell-BNL ERL Test Accelerator (CBETA) has been designed, constructed, and commissioned in a collaboration between Cornell and Brookhaven National Laboratory (BNL). It focuses on energy-saving measures in accelerators, including permanent magnets, energy recovery, and superconductors; it has thus been referred to as a green accelerator. CBETA has become the world's first Energy Recovery Linac (ERL) that accelerates through multiple turns and then recovers the energy in superconducting radiofrequency (SRF) cavities though multiple decelerating turns. The energy is then available to accelerate more beam. It has also become the first accelerator that operates 7 beams in the same large-energy aperture Fixed Field Alternating-gradient (FFA) lattice. The FFA is constructed of permanent combined function magnets and transports energies of 42, 78, 114, and 150 MeV simultaneously. Accelerator physics lessons from the commissioning period will be described and applications of such an accelerator from hadron cooling to EUV lithography and from nuclear physics to a compact Compton source will be discussed.

Deitrick, K. E.↗

Best practices for building energy codes compliance

Building energy codes are a proven policy mechanism to achieve economy-wide energy savings in buildings. In 2021, the International Energy Agency Energy in Buildings and Communities Programme (IEA EBC) Building Energy Codes Working Group (BECWG) set out to survey the diverse codes compliance practices across BECWG member countries. While codes vary in format and approach, attaining the energy reduction potential of building energy codes requires effective implementation and compliance. This is a large undertaking for countries, as effective compliance checking requires adequate resources, technical knowledge, capacity, and strong institutions. Many nations face the same compliance issues, such as requiring faster and easier methods to verify codes and coordinating among numerous stakeholders and levels of government. This paper explores the need for stronger institutional approaches to enforce building energy codes that will lead to code compliance. Specifically, this report sets out to address the question of what practices result in effective building energy code compliance in selected BECWG member countries.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An innovative approach for atrazine electrochemical oxidation modelling: Process parameter effect, intermediate formation and kinetic constant assessment

Water reuse for irrigation activities is becoming a crucial worldwide challenge due to the depletion of water sources. Anyway, agricultural drainage can potentially contain dangerous contaminants such as metals, pesticides, and herbicides, including atrazine. To address the need for agriculture wastewater purification, we investigated atrazine removal from simulated wastewater by electro-oxidation using platinum-coated titanium electrodes on a lab-scale experimental apparatus. The effects of electrolyte composition and concentration, i.e. ionic strength and applied current density on atrazine removal, were investigated. The results demonstrated that the electrochemical oxidation of the herbicide occurred through two routes, depending on the presence or absence of oxidizing chlorine species. The generation of intermediates during the treatment was monitored and quantified by evaluating the effect of an inert electrolyte (NaClO 4 ) versus an oxidizable chlorine species (NaCl). In both experimental conditions, five intermediates were identified, including desethyl-atrazine (DEA), hydroxyatrazine (ATZ-OH), desisopropyl-atrazine (DIA) and desethyl-desisopropyl-atrazine (DEDIA). A degradation mechanism and a model for describing hydroxyl radicals and active chlorine species contributions at ATZ oxidation were also proposed. Intermediate evolution profiles suggest that ATZ degradation can be considered as a series–parallel reaction system. Finally, the energy requirement assessment for ATZ removal was carried out. The highest ATZ removal (≅98%) was achieved with NaCl = 0.08 M, J = 60 A/m −2 , and E C = 5.83 kWh m −3 . Results highlight that atrazine removal was improved when an active chlorine species (NaCl) was present in the water solution. Moreover, the addition of chlorine species during electro-oxidation is an energy-saving strategy. Collectively, electro-oxidation technique can be efficiently applied to treat polluted water in order to meet the needs of recycling water quality and reduce resource consumption.

Electro-chemical oxidation↗

Retrofit-ability: A supplementary metric to inform energy efficiency policies and programs

Building Energy Use Intensity (EUI) has been commonly used to facilitate policy makers and utilities to design energy efficacy programs and help building managers prioritize investment in building upgrades. Buildings with higher EUIs are usually chosen as better candidates for retrofit. Our study of nearly one hundred buildings in Seattle’s Building Tune Up Accelerator program and thousands of buildings in the Asset Score database reveals that EUI (after weather/location/use type normalization) alone is not the best indicator of a building’s potential to save energy, especially for those buildings in the mid-range (30-70 percentile EUI). In this paper, we introduce the concept of “retrofit-ability” — a building’s real potential to reduce its energy use cost-effectively — as a supplementary metric to inform energy efficiency policy and investment. Currently, such potential analyses are predicted for a building stock using prototypical building models or statistical data. However, typical buildings or general historical data may not sufficiently represent building configurations in a portfolio and predict their saving potentials. We utilized machine learning to investigate how key building characteristics (such as envelope attributes, HVAC type, location, use type, etc.) affect a building’s improvement potentials and developed a low-cost method to quantify such potentials for a portfolio of buildings. The supplementary perspective provided by “retrofit-ability” highlights which building assets correlate most with a building’s energy savings potential across region, building use type and more.