Search NASA⌕ Search

SEARCH · Search NASA

Results for “Enhanced Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A fiber optic sensor for noncontact measurement of shaft speed, torque, and power

A fiber optic sensor which enables noncontact measurement of the speed, torque and power of a rotating shaft was fabricated and tested. The sensor provides a direct measurement of shaft rotational speed and shaft angular twist, from which torque and power can be determined. Angles of twist between 0.005 and 10 degrees were measured. Sensor resolution is limited by the sampling rate of the analog to digital converter, while accuracy is dependent on the spot size of the focused beam on the shaft. Increasing the sampling rate improves measurement resolution, and decreasing the focused spot size increases accuracy. Digital processing allows for enhancement of an electronically or optically degraded signal.

Madzsar, George C.↗

A fiber optic sensor for noncontact measurement of shaft speed, torque and power

A fiber optic sensor which enables noncontact measurement of the speed, torque and power of a rotating shaft was fabricated and tested. The sensor provides a direct measurement of shaft rotational speed and shaft angular twist, from which torque and power can be determined. Angles of twist between 0.005 and 10 degrees were measured. Sensor resolution is limited by the sampling rate of the analog to digital converter, while accuracy is dependent on the spot size of the focused beam on the shaft. Increasing the sampling rate improves measurement resolution, and decreasing the focused spot size increases accuracy. Digital processing allows for enhancement of an electronically or optically degraded signal.

Madzsar, George C.↗

Free-volume characteristics of epoxies

Positron annihilation spectroscopy was used to measure free-volume characteristics of selected epoxies. Fluorene resins, a new family of high-temperature thermosetting resins, were selected as the test medium. Experimental results indicate that the free-volume cell size V sub f varies with the molecular weight between the cross-links M sub c according to an equation of the form V sub f = AM sub c sup B, where A and B are structural constants. In two of the samples, the concentration of bulky fluorene groups was increased in the network backbone by replacement of some of the conventional bisphenol A epoxy resin with fluorene-derived epoxy resin. This resulted in an increase in their glass transition temperature for a given level of cross-linking. It was found that in these samples, the Doppler broadening of the annihilation peak decreases with the increasing fluorene content, presumably due to enhanced damping of the chain motions.

Singh, Jag J.↗

Real-time qualitative reasoning for telerobotic systems

This paper discusses the sensor-based telerobotic driving of a car in a-priori unknown environments using 'human-like' reasoning schemes implemented on custom-designed VLSI fuzzy inferencing boards. These boards use the Fuzzy Set theoretic framework to allow very vast (30 kHz) processing of full sets of information that are expressed in qualitative form using membership functions. The sensor-based and fuzzy inferencing system was incorporated on an outdoor test-bed platform to investigate two control modes for driving a car on the basis of very sparse and imprecise range data. In the first mode, the car navigates fully autonomously to a goal specified by the operator, while in the second mode, the system acts as a telerobotic driver's aid providing the driver with linguistic (fuzzy) commands to turn left or right, speed up, slow down, stop, or back up depending on the obstacles perceived by the sensors. Indoor and outdoor experiments with both modes of control are described in which the system uses only three acoustic range (sonar) sensor channels to perceive the environment. Sample results are presented that illustrate the feasibility of developing autonomous navigation modules and robust, safety-enhancing driver's aids for telerobotic systems using the new fuzzy inferencing VLSI hardware and 'human-like' reasoning schemes.

Pin, Eancois G.↗

Flame trench analysis of NLS vehicles

The present study takes the initial steps of establishing a better flame trench design criteria for future National Launch System vehicles. A three-dimensional finite element computer model for predicting the transient thermal and structural behavior of the flame trench walls was developed using both I-DEAS and MSC/NASTRAN software packages. The results of JANNAF Standardized Plume flowfield calculations of sea-level exhaust plume of the Space Shuttle Main Engine (SSME), Space Transportation Main Engine (STME), and Advanced Solid Rocket Motors (ASRM) were analyzed for different axial distances. The results of sample calculations, using the developed finite element model, are included. The further suggestions are also reported for enhancing the overall analysis of the flame trench model.

Zeytinoglu, Nuri↗

Microbial detection with low molecular weight RNA

The need to monitor microorganisms in the environment has increased interest in assays based on hybridization probes that target nucleic acids (e.g., rRNA). We report the development of liquid-phase assays for specific bacterial 5S rRNA sequences or similarly sized artificial RNAs (aRNAs) using molecular beacon technology. These beacons fluoresce only in the presence of specific target sequences, rendering as much as a 27-fold fluorescence enhancement. The assays can be used with both crude cell lysates and purified total RNA preparations. Minimal sample preparation (e.g., heating to promote leakage from cells) is sufficient to detect many Gram-negative bacteria. Using this approach it was possible to detect an aRNA-labeled Escherichia coli strain in the presence of a large background of an otherwise identical E. coli strain. Finally, by using a longer wavelength carboxytetramethylrhodamine beacon it was possible to reduce the fraction of the signal due to cellular autofluorescence to below 0.5%.

NASA Discipline Life Sciences Technologies↗

OVOC (Oxygenated Volatile Organic Chemicals) in the Global Atmosphere: Atmospheric Budgets, Oceanic Concentrations, and Uncertainties

Airborne measurements of oxygenated volatile organic chemicals (OVOC), OH free radicals, and tracers of pollution were performed over the Pacific during Winter/Spring of 2001. Large concentrations of OVOC are present in the global troposphere and are expected to play an important role in atmospheric chemistry. Their total abundance (SIGMAOVOC) was nearly twice that of non-methane hydrocarbons (SIGMAC2-C8 NMHC). Throughout the troposphere, the OH reactivity of OVOC is comparable to that of methane and far exceeds that of NHMC. A comparison of these data with western Pacific observations collected some seven years earlier (Feb.-March, 1994) did not reveal significant differences. Analysis of the relative enhancement of selected OVOC with respect to CH3Cl and CO in twelve plumes originating from fires and sampled in the free troposphere (3-11 km) is used to assess their primary and secondary emissions from biomass combustion. The composition of these plumes also indicates a large shift of reactive nitrogen into the PAN reservoir thereby limiting ozone formation. These data are combined with other observations and interpreted with the help of a global 3-D model to assess OVOC global sources and sinks. We further interpret atmospheric observations with the help of an air-sea exchange model io show that oceans can be both net so~rces and sinks. An extremely large oceanic reservoir of OVOC, that exceeds the atmospheric reservoir by more than an order of magnitude, can be inferred to be present. We conclude that OVOC sources are extremely large (150-500 TgC y-1) but remain poorly quantified. In many cases, measured concentrations are uncertain and incompatible with our present knowledge of atmospheric chemistry. Results based on observations from several field studies and critical gaps will be discussed.

Singh, Hanwant B.↗

Extracting trends from two decades of microgravity macromolecular crystallization history

Since the 1980s hundreds of macromolecular crystal growth experiments have been performed in the reduced acceleration environment of an orbiting spacecraft. Significant enhancements in structural knowledge have resulted from X-ray diffraction of the crystals grown. Similarly, many samples have shown no improvement or degradation in comparison to those grown on the ground. A complex series of interrelated factors affect these experiments and by building a comprehensive archive of the results it was aimed to identify factors that result in success and those that result in failure. Specifically, it was found that dedicated microgravity missions increase the chance of success when compared with those where crystallization took place as a parasitic aspect of the mission. It was also found that the chance of success could not be predicted based on any discernible property of the macromolecule available to us.

Review↗

Analysis of the Atmospheric Distribution, Sources, and Sinks of Oxygenated Volatile Organic Chemicals Based on Measurements over the Pacific during TRACE-P

Airborne measurements of a large number of oxygenated volatile organic chemicals (OVOC) were carried out in the Pacific troposphere (0.1-12 km) in winter/spring of 2001 (24 February to 10 April). Specifically, these measurements included acetone (CH3COCH3), methylethyl ketone (CH3COC2H5, MEK), methanol (CH3OH), ethanol (C2H5OH), acetaldehyde (CH3CHO), propionaldehyde (C2H5CHO), peroxyacylnitrates (PANs) (C(sub n)H(sub 2n+1)COO2NO2), and organic nitrates (C(sub n)H(sub 2n+1)ONO2). Complementary measurements of formaldehyde (HCHO), methyl hydroperoxide (CH3OOH), and selected tracers were also available. OVOC were abundant in the clean troposphere and were greatly enhanced in the outflow regions from Asia. Background mixing ratios were typically highest in the lower troposphere and declined toward the upper troposphere and the lowermost stratosphere. Their total abundance (Summation of OVOC) was nearly twice that of nonmethane hydrocarbons (Summation of C2-C8 NMHC). Throughout the troposphere, the OH reactivity of OVOC is comparable to that of methane and far exceeds that of NMHC. A comparison of these data with western Pacific observations collected some 7 years earlier (February-March 1994) did not reveal significant differences. Mixing ratios of OVOC were strongly correlated with each other as well as with tracers of fossil and biomass/biofuel combustion. Analysis of the relative enhancement of selected OVOC with respect to CH3Cl and CO in 12 plumes originating from fires and sampled in the free troposphere (3-11 km) is used to assess their primary and secondary emissions from biomass combustion. The composition of these plumes also indicates a large shift of reactive nitrogen into the PAN reservoir thereby limiting ozone formation. A three-dimensional global model that uses state of the art chemistry and source information is used to compare measured and simulated mixing ratios of selected OVOC. While there is reasonable agreement in many cases, measured aldehyde concentrations are significantly larger than predicted. At their observed levels, acetaldehyde mixing ratios are shown to be an important source of HCHO (and HO x ) and PAN in the troposphere. On the basis of presently known chemistry, measured mixing ratios of aldehydes and PANs are mutually incompatible. We provide rough estimates of the global sources of several OVOC and conclude that collectively these are extremely large (150-500 Tg C / yr) but remain poorly quantified.

Singh, H. B.↗

Nanoscale Subsurface Imaging via Resonant Difference-Frequency Atomic Force Ultrasonic Microscopy

A novel scanning probe microscope methodology has been developed that employs an ultrasonic wave launched from the bottom of a sample while the cantilever of an atomic force microscope, driven at a frequency differing from the ultrasonic frequency by the fundamental resonance frequency of the cantilever, engages the sample top surface. The nonlinear mixing of the oscillating cantilever and the ultrasonic wave in the region defined by the cantilever tip-sample surface interaction force generates difference-frequency oscillations at the cantilever fundamental resonance. The resonance-enhanced difference-frequency signals are used to create images of embedded nanoscale features.

Cantrell, Sean A.↗

Process to Selectively Distinguish Viable from Non-Viable Bacterial Cells

The combination of ethidium monoazide (EMA) and post-fragmentation, randomly primed DNA amplification technologies will enhance the analytical capability to discern viable from non-viable bacterial cells in spacecraft-related samples. Intercalating agents have been widely used since the inception of molecular biology to stain and visualize nucleic acids. Only recently, intercalating agents such as EMA have been exploited to selectively distinguish viable from dead bacterial cells. Intercalating dyes can only penetrate the membranes of dead cells. Once through the membrane and actually inside the cell, they intercalate DNA and, upon photolysis with visible light, produce stable DNA monoadducts. Once the DNA is crosslinked, it becomes insoluble and unable to be fragmented for post-fragmentation, randomly primed DNA library formation. Viable organisms DNA remains unaffected by the intercalating agents, allowing for amplification via post-fragmentation, randomly primed technologies. This results in the ability to carry out downstream nucleic acid-based analyses on viable microbes to the exclusion of all non-viable cells.

LaDuc, Myron T.↗

Resonant difference-frequency atomic force ultrasonic microscope

A scanning probe microscope and methodology called resonant difference-frequency atomic force ultrasonic microscopy (RDF-AFUM), employs an ultrasonic wave launched from the bottom of a sample while the cantilever of an atomic force microscope, driven at a frequency differing from the ultrasonic frequency by one of the contact resonance frequencies of the cantilever, engages the sample top surface. The nonlinear mixing of the oscillating cantilever and the ultrasonic wave in the region defined by the cantilever tip-sample surface interaction force generates difference-frequency oscillations at the cantilever contact resonance. The resonance-enhanced difference-frequency signals are used to create images of nanoscale near-surface and subsurface features.

Cantrell, John H.↗

Surface-Enhanced X-Ray Fluorescence

Surface-enhanced x-ray fluorescence (SEn-XRF) spectroscopy is a form of surface- enhanced spectroscopy that was conceived as a means of obtaining greater sensitivity in x-ray fluorescence (XRF) spectroscopy. As such, SEn-XRF spectroscopy joins the ranks of such other, longer-wavelength surface-enhanced spectroscopies as those based on surface-enhanced Raman scattering (SERS), surface-enhanced resonance Raman scattering (SERRS), and surfaceenhanced infrared Raman absorption (SEIRA), which have been described in previous NASA Tech Briefs articles. XRF spectroscopy has been used in analytical chemistry for determining the elemental compositions of small samples. XRF spectroscopy is rapid and quantitative and has been applied to a variety of metal and mineralogical samples. The main drawback of XRF spectroscopy as practiced heretofore is that sensitivity has not been as high as required for some applications. In SEn-XRF as in the other surface-enhanced spectroscopies, one exploits several interacting near-field phenomena, occurring on nanotextured surfaces, that give rise to local concentrations of incident far-field illumination. In this case, the far-field illumination comes from an x-ray source. Depending on the chemical composition and the geometry of a given nanotextured surface, these phenomena could include the lightning-rod effect (concentration of electric fields at the sharpest points on needlelike surface features), surface plasmon resonances, and grazing incidence geometric effects. In the far field, the observable effect of these phenomena is an increase in the intensity of the spectrum of interest - in this case, the x-ray fluorescence spectrum of chemical elements of interest that may be present within a surface layer at distances no more than a few nanometers from the surface.

Anderson, Mark↗

Enhanced Fuel-Optimal Trajectory-Generation Algorithm for Planetary Pinpoint Landing

An enhanced algorithm is developed that builds on a previous innovation of fuel-optimal powered-descent guidance (PDG) for planetary pinpoint landing. The PDG problem is to compute constrained, fuel-optimal trajectories to land a craft at a prescribed target on a planetary surface, starting from a parachute cut-off point and using a throttleable descent engine. The previous innovation showed the minimal-fuel PDG problem can be posed as a convex optimization problem, in particular, as a Second-Order Cone Program, which can be solved to global optimality with deterministic convergence properties, and hence is a candidate for onboard implementation. To increase the speed and robustness of this convex PDG algorithm for possible onboard implementation, the following enhancements are incorporated: 1) Fast detection of infeasibility (i.e., control authority is not sufficient for soft-landing) for subsequent fault response. 2) The use of a piecewise-linear control parameterization, providing smooth solution trajectories and increasing computational efficiency. 3) An enhanced line-search algorithm for optimal time-of-flight, providing quicker convergence and bounding the number of path-planning iterations needed. 4) An additional constraint that analytically guarantees inter-sample satisfaction of glide-slope and non-sub-surface flight constraints, allowing larger discretizations and, hence, faster optimization. 5) Explicit incorporation of Mars rotation rate into the trajectory computation for improved targeting accuracy. These enhancements allow faster convergence to the fuel-optimal solution and, more importantly, remove the need for a "human-in-the-loop," as constraints will be satisfied over the entire path-planning interval independent of step-size (as opposed to just at the discrete time points) and infeasible initial conditions are immediately detected. Finally, while the PDG stage is typically only a few minutes, ignoring the rotation rate of Mars can introduce 10s of meters of error. By incorporating it, the enhanced PDG algorithm becomes capable of pinpoint targeting.

Acikmese, Behcet↗

Potential Challenges in Near-Field Scanning Optical Microscopy for Space Applications

Near-field scanning optical microscopy (NSOM) also called scanning near-field optical microscopy (SNOM) is now well accepted as a powerful tool for sub-wavelength (nanoscale in the optical region) spatial resolution microscopy and a large number of related tasks. The importance lies in the fact of strategic advantages of standard microscopy but with significantly enhanced resolution. Since many modern optical diagnostic techniques have found useful applications in space, it is logical to consider the future role of NSOM in such situations. For example, protein crystal growth study under microgravity conditions is a valid candidate. If applied successfully, processes at molecular level can be studied during the growth. NSOM has already been demonstrated to be useful for the study of such crystals here on earth. The basic principle of NSOM can be illustrated. The illumination-collection mode is shown although several other possible approaches exist. In this, the sample is illuminated and the light from the sample is collected through the same tiny aperture opening. A tapered optical fiber is scanned near the sample surface. The tip is coated generally with a metal with a sub-wavelength aperture opening. The tip-sample distance is maintained constant while scanning. Thus, the optical signal available for collection is generally a function of the optical properties of the sample surface. Since the aperture is sub-wavelength in diameter and the tip is held very close (again in the sub-wavelength domain) to the surface, the lateral resolution in the sub-wavelength domain is obtained. Thus, the typical wavelength- order resolution of ordinary microscopy can be significantly enhanced while maintaining the strategic advantages (no need of sample in vacuum chamber, electron beams, etc). Commercial NSOM systems play a key role in the success and widespread acceptance of the tool. These commercial systems work fairly well in laboratory conditions on earth. However, they may not be deployed on a space mission as such with comparable outcome. In this communication we discuss several potential problems and some possible solutions.

Vikram, Chandra S.↗

The Physics of Hard Spheres Experiment on MSL-1: Required Measurements and Instrument Performance

The Physics of HArd Spheres Experiment (PHaSE), one of NASA Lewis Research Center's first major light scattering experiments for microgravity research on complex fluids, flew on board the Space Shuttle's Microgravity Science Laboratory (MSL-1) in 1997. Using colloidal systems of various concentrations of micron-sized plastic spheres in a refractive index-matching fluid as test samples, illuminated by laser light during and after crystallization, investigations were conducted to measure the nucleation and growth rate of colloidal crystals as well as the structure, rheology, and dynamics of the equilibrium crystal. Together, these measurements support an enhanced understanding of the nature of the liquid-to-solid transition. Achievement of the science objectives required an accurate experimental determination of eight fundamental properties for the hard sphere colloidal samples. The instrument design met almost all of the original measurement requirements, but with compromise on the number of samples on which data were taken. The instrument performs 2-D Bragg and low angle scattering from 0.4 deg. to 60 deg., dynamic and single-channel static scattering from 10 deg. to 170 deg., rheology using fiber optics, and white light imaging of the sample. As a result, PHaSE provided a timely microgravity demonstration of critical light scattering measurement techniques and hardware concepts, while generating data already showing promise of interesting new scientific findings in the field of condensed matter physics.

Doherty, Michael P.↗

The Collection, Usage, and Preliminary Examination of the Apollo Sample Suite: Lessons for Artemis

Apollo Sample Collection and Usage: From 1969 to 1972 there were six Apollo missions to the surface of the Moon during which the astronauts collected 382 kg of rock and regolith (~2200 samples). The samples collected fall into these general categories: rocks (~66% by mass), rake samples (~4%), bulk regolith (~24%), and specialty regolith (deep drill cores, drive tubes, sealed bulk regolith) samples (~6%). In each category there are a variety of different subtypes available for study, e.g., among the bulk regolith samples there are also skim, trench, and (partially) shaded regolith samples each sampling unique types or depths of regolith. This variety of subsamples has enabled a multitude of different studies over the past 55 years (>3400 individual requests). We are still averaging ~50 unique requests and have allocated >500 individual Apollo samples annually for the past 10 years (2020 excepted). Looking at the 4,675 non-ANGSA (Apollo Next Generation Sample Analysis) samples allocated over the past 10 years, the proportions of allocated samples do not precisely align with the abundance (by mass) of those samples withing the collection: Rock (69.4 %); Rake (10.8 %); Bulk Regolith (15.5 %); Drive Tube (3.3 %); Core/Specialty (1.0 %). Apollo Preliminary Examination (PE): The PE process differs significantly for the various sample types enumerated above; we focus on regolith and rock samples here. During the Apollo mission era, the PE process evolved over the course of the missions; below is what was done for the Apollo 17 mission. For regolith samples, the PE process was: (1) documented bags containing regolith are opened, photographed, and described; (2) large rocks are removed and treated separately; (3) 25% to 33% of the bulk soil is scooped out, weighed, and stored in reserve; (4) the remaining sample is sieved to produce the size fractions <1, 1- 2, 2-4, and 4-10 mm, all of which are weighed. For rock samples, the process is: (1) removing rocks from the container(s) it came back from the Moon in; (2) rematching any materials that spalled off the rock to their original location; (3) numbering, weighing, and basic photographic documentation; (4) dusting with a gentle N2 gas jet; (5) Orthogonal photography; (6) detailed description of the textures and features of the rock; (7) rock modelling and measurement; (8) stereophotography; (9) determination of the orientation of the rock on the lunar surface. Drive tubes and deep drill cores were not characterized during PE beyond an initial weight and a sketch of the interior tube materials derived from 2D medical X-ray images. Catalogs: The ongoing utility of the Apollo samples is enabled by the robust cataloguing process for the samples [3-5], which allows the scientific community to accurately request samples uniquely suited to their proposed studies. A common misconception, however, is the amount of detail that goes into the initial catalog (e.g., [6]) for a collection from the preliminary examination (PE) period, versus what goes into the catalogs that come later in the life cycle of the samples from that mission (e.g., [7]). The only required data for a PE catalog is a weight, a basic photograph, and a description of the nature of the sample. Artemis PE: Over the past few years, the ongoing ANGSA project studied previously unopened Apollo 17 double drive tube samples 73001/2 [1], and a PE of the drive tubes was done. The PE took the existing core dissection process (developed during PE of Apollo cores in the 1970s, 1980s), and modernized it [7]. The main lesson from the ANGSA PE relative to future missions was that the physical work done during PE of lunar samples has not changed much over the past 5 decades. The use of “modern” technology during PE (e.g., XCT; multispectral analyses) resulted in an enhanced initial understanding of the 73001 and 73002 drive tubes, but greatly increased the time required. The lessons learned from recent astromaterial PEs (e.g., ANGSA and OREx) are important to consider when planning for Artemis, but the unique nature of the Artemis Campaign means many lessons learned from these mission will not be applicable. Given the time constraints (6 months) and likely number of samples that will be returned by Artemis (>200), the Artemis PE catalog will necessarily look much more like [4] than [6].

J Gross↗

Enhanced ultrasonic attenuation of Tl-Ca-Ba-Cu-O at the superconducting transition

Temperature-dependent ultrasonic attenuation measurements have been performed on polycrystalline samples of Tl-Ca-Ba-Cu-O at various frequencies. An attenuation anomaly was observed close to the superconducting transition temperature T(c) (103 K) whose temperature position was frequency-independent. The attenuation decreased exponentially with temperature in the superconducting state for both transverse and longitudinal waves. It was also found that the temperature-dependent sound velocity showed a slope change around T(c).

Sun, K. J.↗