Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLOW REGULATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

DLMP of Competitive Markets in Active Distribution Networks: Models, Solutions, Applications, and Visions

Traditionally, the electric distribution system operates with uniform energy prices across all system nodes. However, as the adoption of distributed energy resources (DERs) propels a shift from passive to active distribution network (ADN) operation, a distribution-level electricity market has been proposed to manage new complexities efficiently. In addition, distribution locational marginal price (DLMP) has been established in the literature as the primary pricing mechanism. The DLMP inherits the LMP concept in the transmission-level wholesale market but incorporates characteristics of the distribution system, such as high $R/X$ ratios and power losses, system imbalance, and voltage regulation needs. The DLMP provides a solution that can be essential for competitive market operation in future distribution systems. This article first provides an overview of the current distribution-level market architectures and their early implementations. Next, the general clearing model, model relaxations, and DLMP formulation are comprehensively reviewed. The state-of-the-art solution methods for distribution market clearing are summarized and categorized into centralized, distributed, and decentralized methods. Then, DLMP applications for the operation and planning of DERs and distribution system operators (DSOs) are discussed in detail. Finally, visions of future research directions and possible barriers and challenges are presented.

42 ENGINEERING↗

Environmental Impacts of Closed-Loop Pumped Storage Hydropower

The goal of this report is to help license applicants, resource agencies, and other members of the hydropower community involved in closed-loop pumped storage hydropower permitting and licensing process, focus the scope of environmental reviews, and more quickly identify impacts with project nexus and potential mitigation measures for these impacts. Pumped storage hydropower (PSH) is an energy storage technology that uses energy to pump water up from a lower reservoir to an upper reservoir where water is stored until electricity is needed and the water is released to a lower reservoir passing through turbines. Closed-loop PSH—PSH that is not continuously connected to a naturally flowing water feature—is one of the lowest greenhouse gas emitting energy storage technologies and is therefore a critical part of the transition to renewable energy (Simon et al. 2023). Proposals for closed-loop PSH facilities in the United States currently account for more than 40% of original licenses and 99% of potential generation capacity in the Federal Energy Regulatory Commission (FERC) hydropower licensing pipeline (Johnson et al. 2023). While closed-loop PSH facilities can have lower environmental impacts than open-loop PSH facilities, no closed-loop facilities have been constructed in the United States to enable direct accounting of project impacts and efficacy of mitigations. Many proposals for closed-loop PSH submitted to FERC are abandoned early in the permitting and licensing process prior to license applications and environmental assessments, so there is little documentation describing potential project impacts and proposed mitigations. The newness of closed-loop PSH proposals in the United States may mean that tribal, federal, and state agencies with authorities for cultural and natural resources protection and management involved in the FERC licensing process may not have experience with closed-loop PSH regulation. Moreover, many proposed closed-loop PSH facilities are in areas that do not have high concentrations of conventional hydropower, so these agencies may also be unfamiliar with the FERC hydropower licensing process. The goal of this report is to help license applicants, resource agencies, and other members of the hydropower community focus the scope of environmental review for the closed-loop PSH development, licensing, and federal authorization process enabling quicker identification of potential impacts, mitigations, and situations where mitigation may not be possible. We found that environmental impacts of closed-loop PSH are highly site-specific, and generalizations about the types of environmental impacts across closed-loop PSH projects are difficult to make. Environmental impacts of closed-loop PSH are like those for open-loop PSH with a few exceptions including water sourcing, which can lead to delays and contention due to potential complexities with water rights, impacts to aquatic resources, and greenhouse gas emission potential. Cultural resource impacts were commonly reported in National Environmental Policy Act (NEPA) documents reviewed and discussed in interviews, but in many cases such impacts cannot be mitigated.

13 HYDRO ENERGY↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Multi-agent Deep Reinforcement Learning for Distribution System Decentralized Voltage Control with High Penetration of PVs

This paper proposes a novel model-free/data-driven centralized training and decentralized execution multi-agent deep reinforcement learning (MADRL) framework for distribution system voltage control with high penetration of PVs. The proposed MADRL can coordinate both the real and reactive power control of PVs with existing static var compensators and battery storage systems. Unlike the existing DRL-based voltage control methods, our proposed method does not rely on a system model during both the training and execution stages. This is achieved by developing a new interaction scheme between the surrogate modeling of the original system and the multi-agent soft actor critic (MASAC) MADRL algorithm. In particular, the sparse pseudo-Gaussian process with a few-shots of measurements is utilized to construct the surrogate model of the original environment, i.e., power flow model. This is a data-driven process and no model parameters are needed. Furthermore, the MASAC enabled MADRL allows to achieve better scalability by dividing the original system into different voltage control regions with the aid of real and reactive power sensitivities to voltage, where each region is treated as an agent. This also serves as the foundation for the centralized training and decentralized execution, thus significantly reducing the communication requirements as only local measurements are required for control. Comparative results with other alternatives on the IEEE 123-nodes and 342-nodes systems demonstrate the superiority of the proposed method.

14 SOLAR ENERGY↗

Fluctuation dynamo in a weakly collisional plasma

The turbulent amplification of cosmic magnetic fields depends upon the material properties of the host plasma. In many hot, dilute astrophysical systems, such as the intracluster medium (ICM) of galaxy clusters, the rarity of particle–particle collisions allows departures from local thermodynamic equilibrium. These departures – pressure anisotropies – exert anisotropic viscous stresses on the plasma motions that inhibit their ability to stretch magnetic-field lines. We present an extensive numerical study of the fluctuation dynamo in a weakly collisional plasma using magnetohydrodynamic (MHD) equations endowed with a field-parallel viscous (Braginskii) stress. When the stress is limited to values consistent with a pressure anisotropy regulated by firehose and mirror instabilities, the Braginskii-MHD dynamo largely resembles its MHD counterpart, particularly when the magnetic field is dynamically weak. If instead the parallel viscous stress is left unabated – a situation relevant to recent kinetic simulations of the fluctuation dynamo and, we argue, to the early stages of the dynamo in a magnetized ICM – the dynamo changes its character, amplifying the magnetic field while exhibiting many characteristics reminiscent of the saturated state of the large-Prandtl-number ( ${Pm}\gtrsim {1}$ ) MHD dynamo. We construct an analytic model for the Braginskii-MHD dynamo in this regime, which successfully matches simulated dynamo growth rates and magnetic-energy spectra. A prediction of this model, confirmed by our numerical simulations, is that a Braginskii-MHD plasma without pressure-anisotropy limiters will not support a dynamo if the ratio of perpendicular and parallel viscosities is too small. This ratio reflects the relative allowed rates of field-line stretching and mixing, the latter of which promotes resistive dissipation of the magnetic field. Finally, in all cases that do exhibit a viable dynamo, the generated magnetic field is organized into folds that persist into the saturated state and bias the chaotic flow to acquire a scale-dependent spectral anisotropy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Visual Tool for Assessing Stability of DER Configurations on Three-Phase Radial Networks

Here, we present a method and tool for evaluating the placement of Distributed Energy Resources (DER) on distribution circuits in order to control voltages and power flows. Our previous work described Phasor-Based Control (PBC), a novel control framework where DERs inject real and reactive power to track voltage magnitude and phase angle targets. Here, we employ linearized power flow equations and integral controllers to develop a linear state space model for PBC acting on a three-phase unbalanced network. We use this model to evaluate whether a given inverter-based DER configuration admits a stable set of controller gains, which cannot be done by analyzing controllability nor by using the Lyapunov equation. Instead, we sample over a parameter space to identify a stable set of controller gains. Our stability analysis requires only a line impedance model and does not entail simulating the system or solving an optimization problem. We incorporate this assessment into a publicly available visualization tool and demonstrate three processes for evaluating many control configurations on the IEEE 123-node test feeder (123NF).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nuclear Safety [Vol. 29, No. 1, January-March 1988]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. THE CHERNOBYL ACCIDENT: 1 Core History and Nuclide Inventory of the Chernobyl Core at the Time of Accident by Gerald Kirchner and Cornelius C. Noack; GENERAL SAFETY CONSIDERATIONS: 6 Nonprescriptive Nuclear Safety Regulation: The Example of Loss of Offsite Power by M. W. Golay, V. P. Manno, and C. Vlahoplus, Jr., 20 Nuclear Power Safety Goals in Light of the Chernobyl Accident by C. Whipple and C. Starr; ACCIDENT ANALYSIS: 29 Containment Loads from Severe Accidents—U.S. Program by W. Kerr and M. K. Dey; PLANT SAFETY FEATURES: 36 Safety Characteristics of Modern High-Temperature Reactors: Focus on German Designs by W. Kröger, H. Nickel, and R. Schulten; ENVIRONMENTAL EFFECTS: 49 Radiation Hormesis and Nuclear Safety by C. C. Congdon; OPERATING EXPERIENCES: 58 Evaluation of Nonradiological Water Chemistry at Power Reactors by Harvey Zibulsky, James J. Kottan, Walter J. Pasciak, Mary Ann Castrogivanni, and Sujit Banerjee, 64 Reactor Shutdown Experience Compiled by J. W. Cletcher, 67 Operating U.S. Power Reactors Compiled by E. G. Silver; RECENT DEVELOPMENTS: 85 General Administrative Activities Compiled by E. G. Silver, 94 Reports, Standards, and Safety Guides by D. S. Queener, 100 Status of Power-Reactor Projects Undergoing Licensing Review Compiled by E. G. Silver, 103 Proposed Rule Changes as of Sept. 30, 1987; ANNOUNCEMENTS: 5 Northwestern University Short Course on Radiation Safety, 28 International Approach to Nuclear Safety (After Three-Mile Island and Chernobyl), 57 RPI Short Course on Modern Developments in Boiling Heat Transfer and Two-Phase Flow, 107 20th DOE/NRC Nuclear Air Cleaning Conference, 110 Third International Topical Meeting on Nuclear Power Plant Thermal Hydraulics and Operations, 108 The Authors, 111 Indexes to Nuclear Safety, Volume 28.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

HERO CarbonSAFE Phase 2 Project in the Columbia River Basalt Group

The Hermiston, Oregon Basalt CarbonSAFE Phase II project (HERO CarbonSAFE) seeks to accelerate the deployment of commercial carbon dioxide (CO2) storage projects in basaltic rocks. Basalt CO2 storage has several advantages to conventional saline storage reservoirs including 1. The potential for rapid mineralization of CO2, 2. Associated decreases in pressure and CO2 migration risks, 3. Reduced long-term monitoring requirements with respect to plume tracking, 4. Widespread geographic distribution and, 5. Large storage potential due to thickness, porosity, and CO2 interactions with basalt. And for locations such as the Pacific Northwest, Hawaii, Iceland, India and Japan, basalts may offer the only economically feasible option for local CO2 storage. However, there are limited field-scale assessments of CO2 storage in basalt, and current carbon capture utilization and storage (CCUS) permitting and regulatory frameworks were developed for conventional saline reservoirs. HERO CarbonSAFE is designed to address research gaps and uncertainties associated with basalt storage. Specifically, the project will assess the feasibility of CO2 injection in the deep layered basalts, long-term storage (mineralization), practical approaches for large-scale implementation (50+ million metric tons of CO2 over 30 years), lithology-specific risks, and the technoeconomic potential for CO2 storage in basalts. The HERO CarbonSAFE project will assess feasibility of developing a commercial-scale (50+ million metric tons of CO2) geological storage complex within the Columbia River Basalt Group (CRBG), a layered continental flood basalt complex that underlies Calpine’s natural gas-fired Hermiston Power Project (HPP) in Hermiston, OR (Figure 1). Under this 2-year CarbonSAFE Phase II project, the HERO team will conduct a data acquisition campaign that includes drilling a stratigraphic well to a total depth of ~1,500 m into the thick layered basalts proximal to HPP. A comprehensive well logging and hydrologic testing program will be augmented with new core collected from flow zones and sealing units, and comprehensive laboratory testing to help refine the kinetic rates of mineralization. The newly acquired information will be integrated with existing data from regional wells to correlate basalt injection zone properties to develop storage hub/commercial-scale models. Using these models, the project team will evaluate injection scenarios to define the technical and economic potential for storing a minimum of 50 million metric tons of CO2 over a 30-year period, along with a robust sensitivity analysis on key parameters governing reservoir viability for sustainable injection over a commercial project lifetime. Specific technical objectives of HERO are: (1) assessing the reservoir response of a series of stacked layered reservoir flowtop sequences occurring in this area of the CRBG to commercial-scale injection volumes; (2) extending prior efforts by the project team to characterize the deep layered basalts encountered in regional studies, to leverage prior investments by U.S. Department of Energy’s (DOE) Carbon Storage program; (3) leveraging DOE’s mineralization characterization efforts to advance model parametrization for commercial scale injection of CO2 in basalts; (4) conducting risk assessments associated with scaling up to commercial storage hub injection goals, while validating DOE’s National Risk Assessment Partnership (NRAP) tools, to identify potential constraints that would prevent the CRBG from serving as a commercial-scale storage complex; (5) developing mitigation plans to address identified risks; (6) developing a commercial-scale injection and monitoring, verification and accounting (MVA) strategy; (7) utilizing computational models to define and minimize, if possible, the Area of Review (AoR) under Class VI regulations; and (8) developing a robust CO2 management strategy for CRBG that also considers a regional source/sink approach that is responsive to stakeholder needs and industrial demand. Specific institutional objectives are: (1) identifying and developing plans to mitigate the nontechnical challenges associated with the build-out of a commercial-scale storage complex within the CRBG with integrated CO2 sources; (2) implementing the community outreach plan; (3) conducting regulatory research, including a survey of issues related to pore space ownership, MVA and long-term assurance of mineralization-based storage, to support an eventual application for a UIC Class VI permit; (4) advancing the project’s plan for CO2 liability management; and (5) continuing to refine and update the project’s economic model. The final objective is the preparation of a comprehensive Site Characterization Plan that draws upon the technical and institutional feasibility assessments to prepare the project for future commercialization efforts.

58 GEOSCIENCES↗

Vadose and Saturated Zone Flow and Transport Calculations for the Active Trenches of the Low-Level Burial Grounds, Hanford Site, Washington

The purpose of the fate and transport modeling described in this environmental calculation file (ECF) is to evaluate the impacts to groundwater associated with waste disposal operations at Mixed Waste Low-Level Burial Ground (LLBG) Trenches 31 and 34 to satisfy requirements in DOE O 435.1, Radioactive Waste Management. The model integrates the flow and transport in the vadose zone beneath the active trenches with the saturated zone downgradient of the trenches to predict the radionuclide concentration at the point of assessment (POA). DOE M 435.1-1, Radioactive Waste Management Manual, defines the POA as the point of highest projected dose or concentration beyond a 100 m (328 ft) buffer zone surrounding the disposed waste. The modeling is conducted in accordance with the DOE G 435.1, Implementation Guide for Use with DOE M 435.1-1, performance assessment (PA) guidelines. The modeling involves evaluation of the groundwater concentrations and radionuclide arrival times during the 1,000-year compliance and 10,000-year sensitivity-uncertainty periods per DOE O 435.1 and DOE M 435.1. This analysis does not consider radionuclide release during facility operations, only the post-closure impacts of the radionuclides to the environment. The evaluation of potential radiological dose to groundwater receptors caused by releases from a closed facility containing radioactive waste typically includes the following: (1) Release of radionuclides from that facility (2) Transport of those radionuclides through the environment, and (3) Exposure to humans to environmental concentration levels of those radionuclides The fate and transport three-dimensional (3D) model analysis involves the post-closure impacts to the environment of the technetium-99, iodone-129, and uranium (all isotopes in the waste). The residual inventory estimates include several radionuclides, but technetium-99 is typically responsible for almost all of the beta-gamma dose equivalent associated with groundwater (water resources) protection per 40 CFR 141, “National Primary Drinking Water Regulations” (e.g., see the results in WCH-520, Performance Assessment of Environmental Restoration Disposal Facility, Hanford Site, Washington; hereinafter referred to as the ERDF PA), and iodone-129 can also be a significant dose contributor for some waste (e.g., RPP-RPT-59958, Performance Assessment for the Integrated Disposal Facility, Hanford Site, Washington; hereinafter referred to as the IDF PA). Uranium does not typically factor significantly into the impacts to groundwater, even during the 10,000-year sensitivity-uncertainty period, but always remains of interest as a contaminant. This ECF does not address vadose and saturated zone modeling for Trench 94 of the 200 East Area LLBG. Current information confirms the validity of the low corrosion rate of the naval reactor plant carbon steel (HY-80), and the even lower corrosion rate of the nickel-iron-chromium alloy reactor vessel (Inconel Alloy 600) presented in DOE/EIS-0259, Final Environmental Impact Statement on the Disposal of Decommissioned, Defueled Cruiser, Ohio Class, and Los Angeles Class Naval Reactor Plants. Based on these low corrosion rates, the time to breach the reactor vessel to allow release of radionuclides from the activated metal of the reactor vessel internal structure is at least 10,000 years. This time to breach precludes the need to evaluate the vadose and saturated zone transport of contaminants released from the reactor compartment disposal packages in the 200 East Area LLBGs PA (CP-63826, Waste Release Model Package Report for the Active Trenches of the Low-Level Burial Grounds, Hanford Site, Washington).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Environmental sensitivities of shallow-cumulus dilution – Part 1: Selected thermodynamic conditions

Cumulus entrainment, and its consequent dilution of buoyant cloud cores, strongly regulates the life cycle of shallow cumuli yet remains poorly understood. Herein, new insights into this problem are obtained through large-eddy simulations that systematically investigate the sensitivity of shallow-cumulus dilution to cloud-layer relative humidity (RH), cloud- and subcloud-layer depths, and continentality (i.e., the land–ocean contrast). The simulated cloud-core dilution is found to be strongly sensitive to continentality, with fractional dilution rates twice as large over the ocean as over land. Using a similarity theory based on the turbulent-kinetic-energy (TKE) budget, the reduced cloud-core dilution over land is attributed to larger cloud-base mass flux (mb), driven by stronger surface heating and subcloud turbulence. As mb increases, the fractional dilution rate must decrease to maintain energetic equilibrium. A positive sensitivity is also found to cloud-layer RH, with the core dilution increasing by 25 %–50 % for a 10 % enhancement in RH. This sensitivity is interpreted using the buoyancy-sorting hypothesis, in that mixtures of cloud and environmental air are more likely to become negatively buoyant and detrain (rather than diluting the cloud core) in drier cloud layers. By contrast, the sensitivities of (marine) shallow-cumulus dilution to cloud- and subcloud-layer depths are weak, with a 3 % decrease for a doubling for the former and a 4 % reduction in dilution for a 50 % deeper subcloud layer. These surprisingly weak sensitivities are readily explained by offsetting effects in the TKE similarity theory. Altogether, these experimental findings provide useful, though still incomplete, guidance for flow-dependent shallow-cumulus entrainment formulations in large-scale models.

54 ENVIRONMENTAL SCIENCES↗

Herbaceous Feedstock 2019 State of Technology Report

The U.S. Department of Energy (DOE) promotes the production of advanced liquid transportation fuels from lignocellulosic biomass by funding fundamental and applied research that advances the State of Technology (SOT). As part of its involvement with this mission, Idaho National Laboratory (INL) completes an annual SOT report for biomass feedstock logistics. This report summarizes supply system impacts of Bioenergy Technologies Office (BETO)-funded research and development efforts at INL and elsewhere (such as the High-Tonnage Feedstock Logistics projects (Webb et al. 2013a, Webb et al. 2013b, Webb et al. 2013c, Webb and Sokhansanj 2014, Sokhansanj et al. 2014)) that lead to improvements in feedstock supply systems. These include improvements to and observed performance of innovative harvest and collection methods, storage technologies, transportation and handling approaches, and advanced preprocessing technologies. Biomass quality and variability, and the interface between feedstock quality and conversion performance are key drivers in addition to delivered feedstock cost. In this report, we estimate the benefits of R&D improvements to individual supply system unit operations and present the status of feedstock logistics technology development for converting biomass into biofuels. These analyses are supported by experimental data where possible and help to align the SOT relative to the cost goals defined in the Multi-Year Program Plan. The 2019 Herbaceous SOT incorporates several technology changes in feedstock preprocessing and introduces opportunities from the integrated landscape management (ILM) strategy and increased grower participation to reduce biomass access costs, while maintaining or improving grower profitability. During FY18 uneven flow from the horizontal bale grinder was identified as a significant issue limiting preprocessing system throughput. Based on FSL-funded research at INL, the 2019 Herbaceous SOT replaces the horizontal bale grinder used in the first stage size reduction with a bale processor. The improved uniformity of biomass flow entering the PDU eliminated slugging flow from the first stage size reduction and improved the throughput of downstream operations. In order to achieve moisture reduction through frictional heating during grinding (which allowed elimination of the costly rotary drum dryer in previous SOTs), the second stage grinder was changed from a rotary shear, which does not remove moisture, back to a hammer mill. Finally, the 2019 Herbaceous SOT introduces modified three-pass and two-pass corn stover supply curves derived from the BT16 resource assessment, based on FY19 modeling results (WBS 4.2.1.20) quantifying economic benefits of ILM in the supply area, together with modeling results (WBS 1.2.1.5) identifying ILM strategies to increase grower participation. The 2019 Herbaceous SOT report documents the current modeled cost of an herbaceous feedstock supply system from harvest to the pretreatment reactor throat for hydrocarbon fuel production via biochemical conversion, based on equipment and processes now available or potentially available in the near term. The modeled cost also considers both the required quality and the availability of the biomass resources. The 2019 Herbaceous SOT predicts a modeled delivered feedstock cost of $81.37 /dry ton (2016$); this is a $2.30/dry ton (2016$) decrease from the 2018 Herbaceous SOT. Technology improvements that contributed to this modeled cost reduction include reduced cost for the new preprocessing design and quantification of the opportunities of the integrated landscape management (ILM) strategy and an increased grower participation rate to reduce the grower payment portion of biomass access costs, while maintaining or improving grower profitability. A greenhouse gas emissions (GHG) assessment was completed by Argonne National Laboratory using the 2019 Greenhouse Gases, Regulated Emissions, and Energy use in Transportation model, estimating an increase of 14.89 kg CO2e/ton from the 2018 SOT (69.27 kg CO2e/ton in 2018 to 84.16 kg CO2e/ton in 2019). The increase of energy consumption during preprocessing along with higher transportation distance to access low cost biomass from further distance contributed to the increase of GHG emissions in the 2019 Herbaceous SOT. The reason for the increased transportation distances was the cost tradeoff of going farther from the biorefinery to access the cheaper ILM-derived counties (the cheaper price outweighed the cost of increased supply radius).

09 BIOMASS FUELS↗

Overcoming the Technical Challenges of Coordinating Distributed Load Resources at Scale (Final Report)

Significant recent research has investigated the potential for loads to provide balancing services to the grid. However, this research has not addressed key issues that may arise when such schemes are applied at scale including: 1. Distribution Network Issues. Coordination of large numbers of loads could result in power flows that violate distribution network constraints; 2. Stability Issues. Certain strategies to control loads can exhibit nonlinearity in the form of period-adding bifurcations and chaos. Other control strategies can potentially synchronize the behavior of large numbers of loads. In both cases, the outcome can be power oscillations and instability; 3. Communication Network Issues. Bidirectional low-latency communication channels between a central controller (or several distributed controllers) and each resource are expensive and likely not necessary for effective coordination. Our research questions were: What network, stability, and communication issues might arise in practice when we coordinate large aggregations of loads? How can we coordinate loads to achieve performance objectives in a cost effective manner while avoiding these issues? The ultimate technical goal of the project was the development of network-aware, communication-constrained, non-disruptive load control strategies with stability guarantees that achieve the performance requirements of typical balancing services at a sufficiently low cost to enable the load aggregator and customer to profit. The overall goal was to establish credibility for load control at scale and contribute to U.S. energy security and environmental goals. The team succeeded in answering these research questions and developing these control strategies. The overall approach was based on the development of three testing environments: a simulation testbed, an experimental testbed (20 physical model houses with window-box air conditioners) coupled with the simulation testbed, and a field testbed (100 actual homes in Austin, TX) coupled with the simulation testbed, which enabled controller testing, identification of issues, controller development, and controller validation. The resulting controller was used to demonstrate fast timescale grid balancing (frequency regulation) by aggregations of physical and virtual air conditioners, with sufficient quality to participate in the electricity market. Cost benefit analysis showed overall benefits to the participating households, load aggregators, and the grid, especially if the control technology was integrated directly into existing programmable communicating thermostats. The project provides a variety of wider benefits. Our technology transfer and outreach activities lead us to choose an open-source licensing commercialization pathway, enabling the project results to be available to researchers, industry, and the public. Furthermore, new grid balancing technologies will increase grid flexibility and will enable higher penetrations of intermittent renewable energy resources, such as wind and solar, to be connected to the grid, reducing its environmental impact, and mitigating climate change to the benefit of society.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nuclear Safety [Vol. 30, No. 3, July-September 1989]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 325 Safety of Framatome Advanced Nuclear Steam Supply Systems Designs by J. A. Charles and D. Lange, 333 Book Review of Nuclear Accidents: Intervention Levels for the Protection of the Public by H. B. Piper; ACCIDENT ANALYSIS: 335 Living PRA Computer Systems by S. C. Dinsmore and H.-P. Balfanz, 343 Summary of ICAP Assessments of RELAP5/MOD2 by W. E. Driskell and R. G. Hanson; CONTROL AND INSTRUMENTATION: 352 Thermal Performance Monitoring System at Maanshan Nuclear Power Plant by H.-J. Chao, Y.-P. Lin, G.-H. Jou, L.-Y. Liao, and Y.-B. Chen; DESIGN FEATURES: 358 Warning Systems for Nuclear Power Plant Emergencies by J. H. Sorensen and D. S. Mileti; WASTE AND SPENT FUEL MANAGEMENT: 371 Activities Related to Waste Management Compiled by E G. Silver; OPERATING EXPERIENCES: 382 Steam Generator Tube Performance: Experience with Water-Cooled Nuclear Power Reactors During 1985 by O. S. Tatone and R. L. Tapping, 400 Systems Interaction Analyses: Concepts and Techniques (Part II) by M. D. Muhlheim and G. A. Murphy, 413 Reactor Shutdown Experience Compiled by J. W. Cletcher, 416 Operating U.S. Power Reactors Compiled by E G. Silver; RECENT DEVELOPMENTS: 440 General Administrative Activities Compiled by E G. Silver, 460 Reports, Standards, and Safety Guides by D. S. Queener, 466 Status of Power-Reactor Licensing Activities Compiled by E G. Silver, 470 Proposed Rule Changes as of Mar. 31, 1989; ANNOUNCEMENTS: 334 Proceedings Published, 351 CEC Seminar on Methods and Codes for Assessing the Off-Site Consequences of Nuclear Accidents, 357 Short Course on Multiphase Flow and Heat Transfer: Bases and Applications in A: The Nuclear Power Industry B: The Process Industries, 357 International Conference on Probabilistic Safety Assessment and Management, 478 International Topical Meeting on the Safety, Status, and Future of Non-Commercial Reactors and Irradiation Facilities, 475 The Authors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Biosensors for the detection of chorismate and cis,cis -muconic acid in Corynebacterium glutamicum

Abstract Corynebacterium glutamicum ATCC 13032 is a promising microbial chassis for industrial production of valuable compounds, including aromatic amino acids derived from the shikimate pathway. In this work, we developed two whole-cell, transcription factor based fluorescent biosensors to track cis,cis-muconic acid (ccMA) and chorismate in C. glutamicum. Chorismate is a key intermediate in the shikimate pathway from which value-added chemicals can be produced, and a shunt from the shikimate pathway can divert carbon to ccMA, a high value chemical. We transferred a ccMA-inducible transcription factor, CatM, from Acinetobacter baylyi ADP1 into C. glutamicum and screened a promoter library to isolate variants with high sensitivity and dynamic range to ccMA by providing benzoate, which is converted to ccMA intracellularly. The biosensor also detected exogenously supplied ccMA, suggesting the presence of a putative ccMA transporter in C. glutamicum, though the external ccMA concentration threshold to elicit a response was 100-fold higher than the concentration of benzoate required to do so through intracellular ccMA production. We then developed a chorismate biosensor, in which a chorismate inducible promoter regulated by natively expressed QsuR was optimized to exhibit a dose-dependent response to exogenously supplemented quinate (a chorismate precursor). A chorismate–pyruvate lyase encoding gene, ubiC, was introduced into C. glutamicum to lower the intracellular chorismate pool, which resulted in loss of dose dependence to quinate. Further, a knockout strain that blocked the conversion of quinate to chorismate also resulted in absence of dose dependence to quinate, validating that the chorismate biosensor is specific to intracellular chorismate pool. The ccMA and chorismate biosensors were dually inserted into C. glutamicum to simultaneously detect intracellularly produced chorismate and ccMA. Biosensors, such as those developed in this study, can be applied in C. glutamicum for multiplex sensing to expedite pathway design and optimization through metabolic engineering in this promising chassis organism. One-Sentence Summary High-throughput screening of promoter libraries in Corynebacterium glutamicum to establish transcription factor based biosensors for key metabolic intermediates in shikimate and β-ketoadipate pathways.

59 BASIC BIOLOGICAL SCIENCES↗

Modifying the resolving cysteine affects the structure and hydrogen peroxide reactivity of peroxiredoxin 2

Peroxiredoxin 2 (Prdx2) is a thiol peroxidase with an active site Cys (C52) that reacts rapidly with H 2 O 2 and other peroxides. The sulfenic acid product condenses with the resolving Cys (C172) to form a disulfide which is recycled by thioredoxin or GSH via mixed disulfide intermediates or undergoes hyperoxidation to the sulfinic acid. C172 lies near the C terminus, outside the active site. It is not established whether structural changes in this region, such as mixed disulfide formation, affect H 2 O 2 reactivity. To investigate, we designed mutants to cause minimal (C172S) or substantial (C172D and C172W) structural disruption. Stopped flow kinetics and mass spectrometry showed that mutation to Ser had minimal effect on rates of oxidation and hyperoxidation, whereas Asp and Trp decreased both by 100-fold. To relate to structural changes, we solved the crystal structures of reduced WT and C172S Prdx2. The WT structure is highly similar to that of the published hyperoxidized form. C172S is closely related but more flexible and as demonstrated by size exclusion chromatography and analytical ultracentrifugation, a weaker decamer. Size exclusion chromatography and analytical ultracentrifugation showed that the C172D and C172W mutants are also weaker decamers than WT, and small-angle X-ray scattering analysis indicated greater flexibility with partially unstructured regions consistent with C-terminal unfolding. We propose that these structural changes around C172 negatively impact the active site geometry to decrease reactivity with H 2 O 2 . This is relevant for Prdx turnover as intermediate mixed disulfides with C172 would also be disruptive and could potentially react with peroxides before resolution is complete.

59 BASIC BIOLOGICAL SCIENCES↗

Precision engineering of biological function with large-scale measurements and machine learning

As synthetic biology expands and accelerates into real-world applications, methods for quantitatively and precisely engineering biological function become increasingly relevant. This is particularly true for applications that require programmed sensing to dynamically regulate gene expression in response to stimuli. However, few methods have been described that can engineer biological sensing with any level of quantitative precision. Here, we present two complementary methods for precision engineering of genetic sensors: in silico selection and machine-learning-enabled forward engineering. Both methods use a large-scale genotype-phenotype dataset to identify DNA sequences that encode sensors with quantitatively specified dose response. First, we show that in silico selection can be used to engineer sensors with a wide range of dose-response curves. To demonstrate in silico selection for precise, multi-objective engineering, we simultaneously tune a genetic sensor’s sensitivity (EC 50 ) and saturating output to meet quantitative specifications. In addition, we engineer sensors with inverted dose-response and specified EC 50 . Second, we demonstrate a machine-learning-enabled approach to predictively engineer genetic sensors with mutation combinations that are not present in the large-scale dataset. We show that the interpretable machine learning results can be combined with a biophysical model to engineer sensors with improved inverted dose-response curves.

59 BASIC BIOLOGICAL SCIENCES↗

Completion of initial reduced-order model for flammable refrigerant dispersal in residential spaces

Environmental regulations aimed at reducing global warming impacts of HVAC&R refrigerants have resulted in the phase-out of chlorofluorocarbons (CFCs) in 2010 and hydrochlorofluorocarbons (HCFCs) by 2030 in developed countries with additional restrictions on the use of hydrofluorocarbons (HFCs) set to take effect in 2036. Many of the remaining alternative refrigerants that have lower global warming potential (GWP) and that are suitable for use in HVAC&R systems (e.g., propane, difluoromethane) are flammable to some degree. Flammable refrigerants introduce new challenges and hazards to property and personal safety related to potential deflagration during system maintenance or due to leakage of the refrigerant accumulating in the conditioned space. Standards have been developed to set maximum charge limits for flammable refrigerants in HVAC&R systems; however, existing safety standards and codes still restrict their use. The bodies that maintain and update these codes need publicly available, science-based information to enable credible guidelines for setting safe charge limits for different flammable refrigerants in different HVAC&R applications. In 2016, the Alliance for Responsible Atmospheric Policy, the Air-Conditioning Heating and Refrigeration Institute (AHRI), ASHRAE, the U.S. Department of Energy (DOE), and the State of California began efforts to develop such information. As part of this effort, Oak Ridge National Laboratory (ORNL) began the current, ongoing project to examine imposed charge limits for flammable refrigerants and identify reasonable adjustments to these limits when found appropriate. Past tasks under this project have included development of experimentally vetted, computational fluid dynamics (CFD) simulation approaches to study the results of leakage of flammable refrigerants from various HVAC&R systems into different types of commercial and residential spaces. In this report, we discuss recent efforts to develop a predictive model of the flammable volume fraction and accumulated refrigerant mass in a single-room residential space resulting from the leak of a flammable refrigerant from a small room air conditioning (RAC) unit. The eventual goal is development of a model suitable for public release which could simulate a range of scenarios. In discussions with the AHRTI Flammable Refrigerant Subcommittee (FRS) at the beginning of this effort, a total of 9 input parameters were chosen for consideration including room area, room/door opening area, ventilation fan flow rate, unit/leak height, leak area, leak rate, total refrigerant charge, refrigerant molecular weight, and state of the unit fan.

42 ENGINEERING↗