Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fast Neutron detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Fast neutron background characterization of the future Ricochet experiment at the ILL research nuclear reactor

Abstract The future Ricochet experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 m away from the 58 MW research nuclear reactor core of the Institut Laue Langevin (ILL) in Grenoble, France. Currently, the Ricochet Collaboration is characterizing the backgrounds at its future experimental site in order to optimize the experiment’s shielding design. The most threatening background component, which cannot be actively rejected by particle identification, consists of keV-scale neutron-induced nuclear recoils. These initial fast neutrons are generated by the reactor core and surrounding experiments (reactogenics), and by the cosmic rays producing primary neutrons and muon-induced neutrons in the surrounding materials. In this paper, we present the Ricochet neutron background characterization using $$^3$$ 3 He proportional counters which exhibit a high sensitivity to thermal, epithermal and fast neutrons. We compare these measurements to the Ricochet Geant4 simulations to validate our reactogenic and cosmogenic neutron background estimations. Eventually, we present our estimated neutron background for the future Ricochet experiment and the resulting CENNS detection significance. Our results show that depending on the effectiveness of the muon veto, we expect a total nuclear recoil background rate between 44 ± 3 and 9 ± 2 events/day/kg in the CENNS region of interest, i.e. between 50 eV and 1 keV. We therefore found that the Ricochet experiment should reach a statistical significance of 4.6 to 13.6 $$\sigma $$ σ for the detection of CENNS after one reactor cycle, when only the limiting neutron background is considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identifying Neutron Irradiation in Space to Mitigate Bio-Medical Effects

One of the primary challenges to interplanetary human travel is mitigation of radiation expo-sure. As fast transit with LENR driven or conventional nuclear electric (NEP) or thermal propulsion (NTP) may be imminent, time and level of radiation exposure composingALARA (As Low as Rea-sonably Achievable) must be ascertained rapidly and precisely. Since acute physiological effects are difficult to detect, and chronic effects on crew health are delayed and potentially trans-generational, improved detection technologies will be game-changing and an essential element of the crew health monitoring and environmental protection toolkit.Secondary Galactic Cosmic Ray (GCR) induced neutrons are an additional hazard.

space medicine↗

The Psyche Gamma-Ray and Neutron Spectrometer

A Gamma-Ray and Neutron Spectrometer (GRNS) instrument has been developed as part of the science payload for NASA’s Discovery Program Psyche mission to the M-class asteroid (16) Psyche. The GRNS instrument is designed to measure the elemental composition of Psyche with the goal to understand the origin of this mysterious, potentially metal-rich planetary body. The GRNS will measure the near-surface abundances for the elements Ni, Fe, Si, K, S, Al, and Ca, as well as the spatial distribution of Psyche’s metal-to-silicate fraction (or metal fraction). These measurements address three of the five Psyche mission science objectives: determine if Psyche is a core; determine whether small metal bodies incorporate light elements into the metal phase; and determine whether Psyche was formed under reducing conditions. The Gamma-Ray Spectrometer (GRS) uses a cryocooled, high-purity Ge (HPGe) sensor to detect cosmic-ray generated gamma rays in the 60 to 9000-keV energy range. The HPGe sensor is surrounded by a borated plastic anticoincidence shield that provides three functions: active background rejection from charged particle interactions in the HPGe sensor; fast neutron measurements; and direct measurements of the incident galactic cosmic ray flux. The Neutron Spectrometer (NS) uses three 3 He gas proportional sensors, each with different material wraps to measure thermal (<0.4 eV), low-energy epithermal (0.4 eV to 1 keV), and high-energy epithermal (up to 100 keV) neutrons. This paper provides an overview of the Psyche GRNS, including: its science and measurement objectives; the design of the instrument hardware, software, and operation; pre-launch performance measurements and its initial performance in space; and an overview of its data products and expected operation for different Psyche mission phases.

Engineering - Instrumentation related to nuclear s↗

Time encoded radiation imaging

The various technologies presented herein relate to detecting nuclear material at a large stand-off distance. An imaging system is presented which can detect nuclear material by utilizing time encoded imaging relating to maximum and minimum radiation particle counts rates. The imaging system is integrated with a data acquisition system that can utilize variations in photon pulse shape to discriminate between neutron and gamma-ray interactions. Modulation in the detected neutron count rates as a function of the angular orientation of the detector due to attenuation of neighboring detectors is utilized to reconstruct the neutron source distribution over 360 degrees around the imaging system. Neutrons (e.g., fast neutrons) and/or gamma-rays are incident upon scintillation material in the imager, the photons generated by the scintillation material are converted to electrical energy from which the respective neutrons/gamma rays can be determined and, accordingly, a direction to, and the location of, a radiation source identified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-modal characterization of the B2 phase in the Ta-Re binary system

The energy and transportation industries demand materials that retain their mechanical property at high temperatures. Refractory complex concentrated alloys (RCCAs) with a BCC + B2 microstructure offer a potential solution, where maintaining the high temperature mechanical properties can be achieved by precipitation strengthening. This depends on the B2 phase in RCCAs being thermodynamically stable with a high solvus temperature. Recently, we predicted the high temperature stability of the B2 structure in the Ta-Re binary system, using density functional theory. Here, in this study, we provide experimental evidence for the existence of this phase for the first time, using a Ta 65 Re 35 alloy. Despite Ta-Re binary phase diagrams predicting a single-phase BCC microstructure for Ta 65 Re 35 , we show that a high Z nanoscale secondary phase appears after heat treatment at 1550 °C and 1100 °C. Scanning transmission electron microscopy (STEM) revealed that this phase has a cubic structure and is equiatomic TaRe though B2 superlattice reflections were absent in fast Fourier transforms (FFT) and diffraction patterns (DPs). DP simulations indicate that the B2 TaRe superlattice reflections are up to two orders of magnitude weaker than their fundamental reflections, making their detection challenging via electron microscopy. Neutron diffraction confirmed the second phase had a B2 structure. This study identified a previously unobserved high temperature stable B2 phase in the Ta-Re system, enabling the development of new high temperature BCC + B2 RCCAs.

36 MATERIALS SCIENCE↗

DEVELOPMENT OF A NUCLEAR FUEL SAFEGUARDS VERIFICATION TECHNOLOGY FOR NEW FACILITY TYPES: Use of fast neutron emission tomography for spent fuel verification

With the buildup of spent fuel inventories around the world from decommissioning activities, a tool for the efficient and effective verification of a variety of fuel types for long-term disposition is needed. Fast neutron emission tomography is a promising imaging technology that can address this problem and has been under development at Oak Ridge National Laboratory for the past two years. The goal of this capability is to detect the removal or substitution of individual fuel pins in spent nuclear fuel assemblies for international safeguards applications. The present imaging technique is based on neutron emissions originating primarily from curium-244, which is produced predominantly at the end of the exposure cycle. As a result, this technique may be sensitive not only to fuel pins that are removed or substituted subsequent to all irradiation, but also to fuel pins that are substituted and subsequently irradiated. At present, a laboratory prototype imager is under construction. The purpose of the prototype is to demonstrate an imaging capabilitysufficient to resolve individual fuel pins using commercially available boron straw detectors that can withstand the high gamma ray dose from a typical spent fuel assembly. To achieve both practical measurement durations and sufficient resolution to discern individual pins, the prototype imager employs a novel collimator design where the slits of a parallel-slit collimator are rearranged to distribute them around a ring surrounding the target fuel assembly. This paper will report on simulations and experimental results undertaken to converge on a final design, image reconstruction of sample fuel types of interest, and challenges associated.

Iyengar, Anagha↗

Characterization of a double-sided silicon strip detector autoradiography system

Purpose: The most commonly used technology currently used for autoradiography is storage phosphor screens, which has many benefits such as a large field of view but lacks particle-counting detection of the time and energy of each detected radionuclide decay. A number of alternative designs, using either solid state or scintillator detectors, have been developed to address these issues. The aim of this study is to characterize the imaging performance of one such instrument, a double-sided silicon strip detector (DSSD) system for digital autoradiography. A novel aspect of this work is that the instrument, in contrast to previous prototype systems using the same detector type, provides the ability for user accessible imaging with higher throughput. Studies were performed to compare its spatial resolution to that of storage phosphor screens and test the implementation of multiradionuclide ex vivo imaging in a mouse preclinical animal study. Methods: Detector background counts were determined by measuring a nonradioactive sample slide for 52 h. Energy spectra and detection efficiency were measured for seven commonly used radionuclides under representative conditions for tissue imaging. System dead time was measured by imaging {sup 18}F samples of at least 5 kBq and studying the changes in count rate over time. A line source of {sup 58}Co was manufactured by irradiating a 10 μm nickel wire with fast neutrons in a research reactor. Samples of this wire were imaged in both the DSSD and storage phosphor screen systems and the full width at half maximum (FWHM) measured for the line profiles. Multiradionuclide imaging was employed in a two animal study to examine the intratumoral distribution of a {sup 125}I-labeled monoclonal antibody and a {sup 131}I-labeled engineered fragment (diabody) injected in the same mouse, both targeting carcinoembryonic antigen. Results: Detector background was 1.81 × 10{sup −6} counts per second per 50 × 50 μm pixel. Energy spectra and detection efficiency were successfully measured for seven radionuclides. The system dead time was measured to be 59 μs, and FWHM for a {sup 58}Co line source was 154 ± 14 μm for the DSSD system and 343 ± 15 μm for the storage phosphor system. Separation of the contributions from {sup 125}I and {sup 131}I was performed on autoradiography images of tumor sections. Conclusions: This study has shown that a DSSD system can be beneficially applied for digital autoradiography with simultaneous multiradionuclide imaging capability. The system has a low background signal, ability to image both low and high activity samples, and a good energy resolution.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Ion Dynamics in Ionic-Liquid-Based Li-Ion Electrolytes Investigated by Neutron Scattering and Dielectric Spectroscopy

A detailed understanding of the diffusion mechanisms of ions in pure and doped ionic liquids remains an important aspect in the design of new ionic-liquid electrolytes for energy storage. Here, to gain more insight into the widely used imidazolium-based ionic liquids, the relationship between viscosity, ionic conductivity, diffusion coefficients, and reorientational dynamics in the ionic liquid 3-methyl-1-methylimidazolium bis(trifluoromethanesulfonyl)imide (DMIM-TFSI) with and without lithium bis(trifluoromethanesulfonyl)imide (Li-TFSI) was examined. The diffusion coefficients for the DMIM + cation and the role of ion aggregates were investigated by using the quasielastic neutron scattering (QENS) and neutron spin echo techniques. Two diffusion mechanisms are observed for the DMIM + cation with and without Li-TFSI, that is, translational and local. The data additionally suggest that Li + ion transport along with ion aggregates, known as the vehicle mechanism, may play a significant role in the ion diffusion process. These dielectric-spectroscopy investigations in a broad temperature and frequency range reveal a typical α–β-relaxation scenario. The α relaxation mirrors the glassy freezing of the dipolar ions, and the β relaxation exhibits the signatures of a Johari–Goldstein relaxation. In contrast to the translational mode detected by neutron scattering, arising from the decoupled faster motion of the DMIM + ions, the α relaxation is well coupled to the dc charge transport, that is, the average translational motion of all three ion species in the material. Finally, the local diffusion process detected by QENS is only weakly dependent on temperature and viscosity and can be ascribed to the typical fast dynamics of glass-forming liquids.

25 ENERGY STORAGE↗

Materials characterisation with the associated particle technique

Since the last past years, the Nuclear Measurement Laboratory of CEA Cadarache, France, together with Partners from European and National projects, has been studying the application of fast neutron interrogation with the Associated Particle Technique for material identification in different areas of homeland and maritime security, and for the characterisation of the materials constituting radioactive waste. Fast 14 MeV neutrons are produced from the H-3(H-2,n)alpha fusion reaction in a sealed tube neutron generator embedding an alpha detector. The alpha particle is used to tag neutron direction and emission time, thus allowing the electronic selection of neutron-induced gamma spectra in the voxels of interest. Gamma rays emitted by tagged neutron interactions on the present nuclei (C, O, N, Fe, Al, Si, Cl, etc.) are recorded with spectroscopic detectors and analysed to determine elemental proportions, thus allowing material identification. Investigations have been conducted for the detection of explosives, illicit drugs and contraband materials in cargo containers, for the inspection of objects lying on the sea floor suspected to contain explosives like mines, bombs, torpedoes, etc., for the recognition of an improvised chemical device, and for material identification in radioactive waste packages. Recently the detection of special nuclear materials is being investigated using time correlation analysis between induced fission particles, instead of gamma-ray spectroscopy. The paper presents an overview of these studies and last results. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MIGDAL experiment: Measuring a rare atomic process to aid the search for dark matter

We present the Migdal In Galactic Dark mAtter expLoration (MIGDAL) experiment aiming at the unambiguous observation and study of the so-called Migdal effect induced by fast-neutron scattering. It is hoped that this elusive atomic process can be exploited to enhance the reach of direct dark matter search experiments to lower masses, but it is still lacking experimental confirmation. Our goal is to detect the predicted atomic electron emission which is thought to accompany nuclear scattering with low, but calculable, probability, by deploying an Optical Time Projection Chamber filled with a low-pressure gas based on CF 4 . Initially, pure CF 4 will be used, and then in mixtures containing other elements employed by leading dark matter search technologies — including noble species, plus Si and Ge. High resolution track images generated by a Gas Electron Multiplier stack, together with timing information from scintillation and ionisation readout, will be used for 3D reconstruction of the characteristic event topology expected for this process — an arrangement of two tracks sharing a common vertex, with one belonging to a Migdal electron and the other to a nuclear recoil. Different energy-loss rate distributions along both tracks will be used as a powerful discrimination tool against background events. In this article we present the design of the experiment, informed by extensive particle and track simulations and detailed estimations of signal and background rates. In pure CF 4 we expect to observe 8.9 (29.3) Migdal events per calendar day of exposure to an intense D–D (D–T) neutron generator beam at the NILE facility located at the Rutherford Appleton Laboratory (UK). With our nominal assumptions, 5σ median discovery significance can be achieved in under one day with either generator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of neutron measurement in high gamma field using new nuclear emulsion

To precisely measure the neutron emissions from a spent fuel assembly of a fast breeder reactor, we formed nuclear emulsions based on a non-sensitized Oscillation Project with Emulsion tracking Apparatus (OPERA) film with AgBr grain sizes of 60, 90, and 160 nm. The efficiency for {sup 252}Cf neutron detection of the new emulsion was calculated to be 0.7 x 10{sup -4}, which corresponded to an energy range from 0.3 to 2 MeV and was consistent with a preliminary estimate based on experimental results. The sensitivity of the new emulsion was also experimentally estimated by irradiating with 565 keV and 14 MeV neutrons. The emulsion with an AgBr grain size of 60 nm had the lowest sensitivity among the above three emulsions but was still sensitive enough to detect protons. Furthermore, the experimental data suggested that there was a threshold linear energy transfer of 15 keV/{mu}m for the new emulsion, below which no silver clusters developed. Further development of nuclear emulsion with an AgBr grain size of a few tens of nanometers will be the next stage of the present study. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge-Injection-Device Performance in the High-Energy-Neutron Environment of Laser-Fusion Experiments

Charge-injection devices (CIDs) are being used to image x rays in laser-fusion experiments on the University of Rochester’s OMEGA Laser System. The CID cameras are routinely used up to the maximum neutron yields generated (~10^14 DT). The detectors are deployed in x-ray pinhole cameras and Kirkpatrick–Baez microscopes. The neutron fluences ranged from ~10^7 to ~10^9 neutrons/cm^2 and useful x-ray images were obtained even at the highest fluences. It is intended to use CID cameras at the National Ignition Facility (NIF) as a supporting means of recording x-ray images. The results of this work predict that x-ray images should be obtainable on the NIF at yields up to ~10^15, depending on distance and shielding.

Marshall, F J↗

Correlated Signal Analysis for Nuclear Emergency Response

In the context of nuclear emergency response (NER) scenarios, the critical task is to quickly identify a "black box" as a potential threat, as failing to do so could have catastrophic consequences. Techniques for passive assay of a “black box” typically include gamma-ray spectroscopy and neutron coincidence/multiplicity counting. However, there are significant challenges associated with these type of measurements. First, the presence of intervening materials can obstruct the detection of relevant signatures. Second, the presence of strong non-fission neutron sources, like (α, n) emitters, can add uncertainties to the neutron multiplicity analysis. In our LDRD-MFR Phase II work, a portable neutron spectrometer, called the Compact Fast Neutron Spectrometer (CFNS), was developed for NER applications. The CFNS system leverages information-rich neutron energy spectra to derive actionable information. This work investigates the use of correlated signals in the CFNS from special nuclear material (SNM) to characterize physical properties, such as intervening shielding material and fission to non-fission neutron contributions. In this report, the Phase II results from bulk SNM measurements at the National Criticality Experiments Research Center (NCERC) are briefly discussed along with the motivation for this work. Afterwards, simulations using the MCNPX-PoliMi transport code are discussed, which were used to expand our correlated signal study. Signal triggered analysis for neutron multiplicity extraction will also be discussed. Lastly, the use neutron-photon correlations for intervening material identification are shown, along with the use of correlated neutron energy spectra for α-ratio extraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of uranium-photofission neutrons with a 4 He scintillation detector

The use of photon active interrogation to detect special nuclear material has held significant theoretical promise, as the interrogating source particles, photons, are fundamentally different from one of the main signatures of special nuclear material: neutrons produced in nuclear fission. However, neutrons produced by photonuclear reactions in the accelerator target, collimator, and environment can obscure the fission neutron signal. These (γ, n) neutrons could be discriminated from fission neutrons by their energy spectrum, but common detectors sensitive to the neutron spectrum, like organic scintillators, are typically hampered by the intense photon background characteristic of photon-based active interrogation. In contrast, high-pressure 4 ⁢He-based scintillation detectors are well-suited to photon active interrogation, as they are similarly sensitive to fast neutrons and can measure their spectrum, but show little response to gamma rays. Here, in this work, a photon active interrogation system utilizing a 4 ⁢He scintillation detector and a 9 MeV linac-bremsstrahlung x-ray source was experimentally evaluated. The detector was shown to be capable of operating in intense gamma-ray environments and detecting photofission neutrons from 238 ⁢U when interrogated by this x-ray source. The photofission neutrons show clear spectral separation from (γ, n) neutrons produced in lead, a common shielding material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual Gamma Neutron Directional Elpasolite Detector

Some applications, particularly in homeland security, require detection of both neutron and gamma radiation. Typically, this is accomplished with a combination of two detectors registering neutrons and gammas separately. We have investigated a new type of neutron/gamma (n/γ) directional detection capability. We explored a new class of scintillator, cerium (Ce)-doped Elpasolites such as Cs2LiYCl6:Ce (CLYC), Cs2LiLaCl6 (CLLC), Cs2LiLaBr6:Ce (CLLB), or Cs2LiYBr6:Ce (CLYB). These materials are capable of providing energy resolution as good as 2.9% at 662 keV (FWHM), which is better than that of NaI:Tl. Because they contain 6Li, Elpasolites can also detect thermal neutrons. In the energy spectra, the full energy thermal neutron peak appears near or above 3 GEEn MeV. Thus, very effective pulse height discrimination is possible. In addition, the core-to-valence luminescence (CVL) provides Elpasolites with different temporal responses under gamma and neutron excitation, and, therefore, may be exploited for effective pulse shape discrimination. For instance, the CLLC emission consists of two main components: (1) CVL spanning from 220 nm to 320 nm and (2) Ce emission found in the range of 350 to 500 nm. The former emission is of particular interest because it appears only under gamma excitation. It is also very fast, decaying with a 2 ns time constant. The n/γ discrimination capability of Elpasolite detectors may be optimized by tuning the cerium doping content for maximum effect on n/γ pulse shape differences. The resulting Elpasolite detectors have the ability to collect neutron and gamma data simultaneously, with excellent discrimination. Further, an array of four of these Elpasolites detectors will perform directional detection in both the neutron and gamma channels simultaneously.

radiation detectors, neutron detectors, scintillat↗

XMM-NEWTON X-RAY DETECTION OF THE HIGH-MAGNETIC-FIELD RADIO PULSAR PSR B1916+14

Using observations made with the XMM-Newton Observatory, we report the first X-ray detection of the high-magnetic-field radio pulsar PSR B1916+14. We show that the X-ray spectrum of the pulsar can be well fitted with an absorbed blackbody with temperature in the range of 0.08-0.23 keV, or a neutron-star hydrogen atmosphere model with best-fit effective temperature of approx0.10 keV, higher than expected from fast cooling models. The origin of the likely thermal emission is not well constrained by our short observation and is consistent with initial cooling or return-current heating. We found no pulsations in these data and set a 1sigma upper limit on the pulsed fraction in the 0.1-2 keV band of approx0.7. Implications of these results for our understanding of the different observational properties of isolated neutron stars are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Gamma and neutron detection modeling in the nuclear detection figure of merit (NDFOM) portal

The Nuclear Detection Figure Of Merit (NDFOM) portal is a database of objects and algorithms for evaluating the performance of radiation detectors to detect nuclear material. This paper describes the algorithms used to model the physics and mathematics of radiation detection. As a first-principles end-to-end analysis system, it starts with the representation of the gamma and neutron spectral fluxes, which are computed with the particle and radiation transport code MCNPX. The gamma spectra emitted by uranium, plutonium, and several other materials of interest are described. The impact of shielding and other intervening material is computed by the method of build-up factors. The interaction of radiation with the detector material is computed by a detector response function approach. The construction of detector response function matrices based on MCNPX simulation runs is described in detail. Neutron fluxes are represented in a three group formulation to treat differences in detector sensitivities to thermal, epithermal, and fast neutrons.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fission neutron spectra measurements at LANSCE - status and plans

A program to measure fission neutron spectra from neutron-induced fission of actinides is underway at the Los Alamos Neutron Science Center (LANSCE) in a collaboration among the CEA laboratory at Bruyeres-le-Chatel, Lawrence Livermore National Laboratory and Los Alamos National Laboratory. The spallation source of fast neutrons at LANSCE is used to provide incident neutron energies from less than 1 MeV to 100 MeV or higher. The fission events take place in a gas-ionization fission chamber, and the time of flight from the neutron source to that chamber gives the energy of the incident neutron. Outgoing neutrons are detected by an array of organic liquid scintillator neutron detectors, and their energies are deduced from the time of flight from the fission chamber to the neutron detector. Measurements have been made of the fission neutrons from fission of {sup 235}U, {sup 238}U, {sup 237}Np and {sup 239}Pu. The range of outgoing energies measured so far is from 1 MeV to approximately 8 MeV. These partial spectra and average fission neutron energies are compared with evaluated data and with models of fission neutron emission. Results to date will be presented and a discussion of uncertainties will be given in this presentation. Future plans are to make significant improvements in the fission chambers, neutron detectors, signal processing, data acquisition and the experimental environment to provide high fidelity data including mea urements of fission neutrons below 1 MeV and improvements in the data above 8 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗