Search NASA⌕ Search

SEARCH · Search NASA

Results for “Filtering techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Methods for detection and characterization of signals in noisy data with the Hilbert-Huang transform

The Hilbert-Huang transform is a novel, adaptive approach to time series analysis that does not make assumptions about the data form. Its adaptive, local character allows the decomposition of nonstationary signals with high time-frequency resolution but also renders it susceptible to degradation from noise. We show that complementing the Hilbert-Huang transform with techniques such as zero-phase filtering, kernel density estimation and Fourier analysis allows it to be used effectively to detect and characterize signals with low signal-to-noise ratios.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bayesian network ensemble as a multivariate strategy to predict radiation pneumonitis risk

Purpose: Prediction of radiation pneumonitis (RP) has been shown to be challenging due to the involvement of a variety of factors including dose–volume metrics and radiosensitivity biomarkers. Some of these factors are highly correlated and might affect prediction results when combined. Bayesian network (BN) provides a probabilistic framework to represent variable dependencies in a directed acyclic graph. The aim of this study is to integrate the BN framework and a systems’ biology approach to detect possible interactions among RP risk factors and exploit these relationships to enhance both the understanding and prediction of RP. Methods: The authors studied 54 nonsmall-cell lung cancer patients who received curative 3D-conformal radiotherapy. Nineteen RP events were observed (common toxicity criteria for adverse events grade 2 or higher). Serum concentration of the following four candidate biomarkers were measured at baseline and midtreatment: alpha-2-macroglobulin, angiotensin converting enzyme (ACE), transforming growth factor, interleukin-6. Dose-volumetric and clinical parameters were also included as covariates. Feature selection was performed using a Markov blanket approach based on the Koller–Sahami filter. The Markov chain Monte Carlo technique estimated the posterior distribution of BN graphs built from the observed data of the selected variables and causality constraints. RP probability was estimated using a limited number of high posterior graphs (ensemble) and was averaged for the final RP estimate using Bayes’ rule. A resampling method based on bootstrapping was applied to model training and validation in order to control under- and overfit pitfalls. Results: RP prediction power of the BN ensemble approach reached its optimum at a size of 200. The optimized performance of the BN model recorded an area under the receiver operating characteristic curve (AUC) of 0.83, which was significantly higher than multivariate logistic regression (0.77), mean heart dose (0.69), and a pre-to-midtreatment change in ACE (0.66). When RP prediction was made only with pretreatment information, the AUC ranged from 0.76 to 0.81 depending on the ensemble size. Bootstrap validation of graph features in the ensemble quantified confidence of association between variables in the graphs where ten interactions were statistically significant. Conclusions: The presented BN methodology provides the flexibility to model hierarchical interactions between RP covariates, which is applied to probabilistic inference on RP. The authors’ preliminary results demonstrate that such framework combined with an ensemble method can possibly improve prediction of RP under real-life clinical circumstances such as missing data or treatment plan adaptation.

60 APPLIED LIFE SCIENCES↗

Improved accuracy of quantitative parameter estimates in dynamic contrast-enhanced CT study with low temporal resolution

Purpose: A previously proposed method to reduce radiation dose to patient in dynamic contrast-enhanced (DCE) CT is enhanced by principal component analysis (PCA) filtering which improves the signal-to-noise ratio (SNR) of time-concentration curves in the DCE-CT study. The efficacy of the combined method to maintain the accuracy of kinetic parameter estimates at low temporal resolution is investigated with pixel-by-pixel kinetic analysis of DCE-CT data. Methods: The method is based on DCE-CT scanning performed with low temporal resolution to reduce the radiation dose to the patient. The arterial input function (AIF) with high temporal resolution can be generated with a coarsely sampled AIF through a previously published method of AIF estimation. To increase the SNR of time-concentration curves (tissue curves), first, a region-of-interest is segmented into squares composed of 3 × 3 pixels in size. Subsequently, the PCA filtering combined with a fraction of residual information criterion is applied to all the segmented squares for further improvement of their SNRs. The proposed method was applied to each DCE-CT data set of a cohort of 14 patients at varying levels of down-sampling. The kinetic analyses using the modified Tofts’ model and singular value decomposition method, then, were carried out for each of the down-sampling schemes between the intervals from 2 to 15 s. The results were compared with analyses done with the measured data in high temporal resolution (i.e., original scanning frequency) as the reference. Results: The patients’ AIFs were estimated to high accuracy based on the 11 orthonormal bases of arterial impulse responses established in the previous paper. In addition, noise in the images was effectively reduced by using five principal components of the tissue curves for filtering. Kinetic analyses using the proposed method showed superior results compared to those with down-sampling alone; they were able to maintain the accuracy in the quantitative histogram parameters of volume transfer constant [standard deviation (SD), 98th percentile, and range], rate constant (SD), blood volume fraction (mean, SD, 98th percentile, and range), and blood flow (mean, SD, median, 98th percentile, and range) for sampling intervals between 10 and 15 s. Conclusions: The proposed method of PCA filtering combined with the AIF estimation technique allows low frequency scanning for DCE-CT study to reduce patient radiation dose. The results indicate that the method is useful in pixel-by-pixel kinetic analysis of DCE-CT data for patients with cervical cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-502: FFF Beams, Jaw-Tracking and Treatment Techniques: Out of Field Dose Considerations for Pediatric Radiation Therapy Delivery

Purpose: To compare the extended dose profile delivered by 3DCRT and VMAT techniques for flattened and flattening-filter-free(FFF) photon beams (6X, 6XFFF,10XFFF), with and without jaw-tracking (JT) on Varian TrueBeam linac. The goal is to determine which treatment technique/modality will minimize the peripheral photon dose exposure (and ultimately minimize the risk of second malignant neoplasms (SMN)) in pediatric patients. Methods: 3DCRT, VMAT, and jaw tracking VMAT (JTVMAT) plans with 6X, 6XFFF and 10XFFF x-ray beams were created on a 30×60×22.5cm solid water phantom with a 551 cc PTV. The 3DCRT plans consisted of a 4FLD arrangement. The optimization objectives for the single-arc VMAT plans was V95%Rx=98% to PTV and minimize dose to a 5cm diameter organ at risk (OAR). The OAR to PTV distance varied from 0–30cm along the long axis at 7.5cm depth. The dose to the center of the OAR was measured using a 0.6cc ion chamber. Results: Relative to the 6X flattened beam, the 10XFFF photon beam had the lowest dose in the penumbra and peripheral region (>15 cm) region by up to 20% and 40%, respectively for all modalities (3DCRT, VMAT, JTVMAT). The 6XFFF beams only showed a dose reduction in the peripheral region (by up to 20%). JT did not significantly affect the peripheral dose for all modalities and energies. Conclusion: Treating pediatric patients with a 10XFFF beam is the most effective way to reduce photon scatter dose in both the penumbra and peripheral regions. However, the neutron dose contribution resulting from the 10MV beam still needs to be considered. For all modalities, 6XFFF was the next effective method to reduce peripheral photon doses. 3DCRT beams had the lowest peripheral doses for all energies compared to VMAT and JTVMAT, however previous publications have shown that this comes at the expense of PTV conformity and OAR sparing.

60 APPLIED LIFE SCIENCES↗

Modeling, sensor design, and performance predictions for gas filter correlation radiometers

Gas filter correlation (GFC) radiometry is a technique for detecting and measuring a specific gas or a small suite of gases. The GFC approach combines extremely high spectral resolution with high optical throughput (or etendue) while avoiding the stringent alignment and mechanical stability requirements imposed by interferometric measurements. The GFC approach is well matched to staring imagers and is very efficient in terms of data volume and bandwidth. A primary limitation to GFC for atmospheric remote sensing is the fact that it works best with gases that have strong absorption features but that are present in small concentrations. This report describes a software model that was developed to predict the performance of GFC sensors. This report presents a design for an airborne GFC sensor and predicts the ability of this sensor and a hypothetical satellite sensor to measure methane in the atmosphere.

Mercier, Jeffrey Alan↗

Quantitative chemical assay of nanogram-level particulate matter using aerosol mass spectrometry: characterization of particles collected from uncrewed atmospheric measurement platforms

Abstract. Aerosol generation techniques have expanded the utility of aerosol mass spectrometry (AMS) for offline chemical analysis of airborne particles and droplets. However, standard aerosolization techniques require relatively large liquid volumes (e.g., several milliliters) and high sample masses that limit their utility. Here we report the development and characterization of a micronebulization AMS (MN-AMS) technique that requires as low as 10 µL of sample and can provide the quantification of the nanogram level of organic and inorganic substances via the usage of an isotopically labeled internal standard (34SO42-). Using standard solutions, the detection limits for this technique were determined at 0.19, 0.75, and 2.2 ng for sulfate, nitrate, and organics, respectively. The analytical recoveries for these species are 104 %, 87 %, and 94 %, respectively. This MN-AMS technique was applied successfully to analyze filter and impactor samples collected using miniature particulate matter (PM) samplers deployable on uncrewed atmospheric measurement platforms, such as uncrewed aerial systems (UASs) and tethered balloon systems (TBSs). Chemical composition of PM samples collected from a UAS field campaign conducted at the Department of Energy's (DOE) Southern Great Plains (SGP) observatory was characterized. The offline MN-AMS data compared well with the in situ PM composition measured by a co-located aerosol chemical speciation monitor (ACSM). In addition, the MN-AMS and ion chromatography (IC) agreed well for measurements of sulfate and nitrate concentrations in the PM extracts. This study demonstrates the utility of combining MN-AMS with uncrewed measurement platforms to provide quantitative measurements of ambient PM composition.

54 ENVIRONMENTAL SCIENCES↗

A Method of Estimating Sparse and Doubly-Dispersive Channels

The large delay and Doppler spreads of skywave high-frequency (HF) channels complicates channel acquisition, especially in low-SNR conditions. Using pilot-symbol assisted modulation, we develop a robust method to acquire channel information by first estimating the power-delay profile (PDP) of the channel, then applying that estimate to obtain the channel coefficients only where the PDP is nonzero. We find the presented approach to be robust at low-SNRs, making it suitable for spread-spectrum and underlay waveforms. We show that this two-stage channel acquisition procedure has three advantages: i),the channel is estimated with fewer terms, reducing complexity; ii), the MSE of the channel estimate is lower than assuming a fixed channel length; and iii), each propagation mode is reliably recovered in high-Doppler conditions. We conclude this paper by presenting results of the developed techniques as applied to a filter-bank multicarrier spread-spectrum (FBMC-SS) waveform.

42 ENGINEERING↗

A model-based framework for the detection of spiculated masses on mammography

The detection of lesions on mammography is a repetitive and fatiguing task. Thus, computer-aided detection systems have been developed to aid radiologists. The detection accuracy of current systems is much higher for clusters of microcalcifications than for spiculated masses. In this article, the authors present a new model-based framework for the detection of spiculated masses. The authors have invented a new class of linear filters, spiculated lesion filters, for the detection of converging lines or spiculations. These filters are highly specific narrowband filters, which are designed to match the expected structures of spiculated masses. As a part of this algorithm, the authors have also invented a novel technique to enhance spicules on mammograms. This entails filtering in the radon domain. They have also developed models to reduce the false positives due to normal linear structures. A key contribution of this work is that the parameters of the detection algorithm are based on measurements of physical properties of spiculated masses. The results of the detection algorithm are presented in the form of free-response receiver operating characteristic curves on images from the Mammographic Image Analysis Society and Digital Database for Screening Mammography databases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nanoscale Energy-Filtered Scanning Confocal Electron Microscopy Using a Double-Aberration-Corrected Transmission Electron Microscope

We demonstrate that a transmission electron microscope fitted with two spherical-aberration correctors can be operated as an energy-filtered scanning confocal electron microscope. A method for establishing this mode is described and initial results showing 3D chemical mapping with nanoscale sensitivity to height and thickness changes in a carbon film are presented. Importantly, uncorrected chromatic aberration does not limit the depth resolution of this technique and moreover performs an energy-filtering role, which is explained in terms of a combined depth and energy-loss response function.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a low-power, low-cost front end electronics module for large scale distributed neutrino detectors

A number of concepts have been presented for distributed neutrino detectors formed of large numbers of autonomous detectors. Examples include the Antarctic Ross Ice Shelf Antenna Neutrino Array (ARIANNA) [Barwick 2006], as well as proposed radio extensions to the IceCube detector at South Pole Station such as AURA and IceRay. [Besson 2008]. We have focused on key enabling technical developments required by this class of experiments. The radio Cherenkov signal, generated by the Askaryan mechanism [Askaryan 1962, 1965], is impulsive and coherent up to above 1 GHz. In the frequency domain, the impulsive character of the emission results in simultaneous increase of the power detected in multiple frequency bands. This multiband triggering approach has proven fruitful, especially as anthropogenic interference often results from narrowband communications signals. A typical distributed experiment of this type consists of a station responsible for the readout of a cluster of antennas either near the surface of the ice or deployed in boreholes. Each antenna is instrumented with a broadband low-noise amplifier, followed by an array of filters to facilitate multi-band coincidence trigger schemes at the antenna level. The power in each band is detected at the output of each band filter, using either square-law diode detectors or log-power detectors developed for the cellular telephone market. The use of multiple antennas per station allows a local coincidence among antennas to be used as the next stage of the trigger. Station triggers can then be combined into an array trigger by comparing timestamps of triggers among stations and identifying space-time clusters of station triggers. Data from each station is buffered and can be requested from the individual stations when a multi-station coincidence occurs. This approach has been successfully used in distributed experiments such as the Pierre Auger Observatory. [Abraham et al. 2004] We identified the filters as being especially critical. The frequency range of interest, {approx}200 MHz to {approx}1.2 GHz, is a transitional region where the lumped circuit element approach taken at low frequencies begins to reach limitations due to component tolerances, component losses, and parasitic effects. Active circuits can help to mitigate against these effects at the cost of added power consumption that becomes prohibitive for distributed experiments across the band of interest. At higher frequency microstrip, stripline, and other microwave techniques come to the fore. We have developed designs and design tools for passive filters extending the high frequency techniques to the frequency range of interest. Microstrip and stripline techniques are not usually attractive here because of the large physical dimensions of the resulting circuits, but in this application the tradeoff of size against power consumption favors this choice. These techniques are also intrinsically low-cost, as the filter is built into the circuit boards and the cost of components and their assembly onto the board is avoided. The basic element of the filter tree is an impedance matched wideband diplexer. This consists of a pair of low pass and high pass filters with a shared cutoff frequency and complementary frequency responses. These are designing the lowpass filter as a high order LC filter, which can be implemented as a series of transmission line segments of varying width. This can be transformed in to a CL high pass filter with a complementary frequency response. When the two filters are coupled to a common input, the input impedances of the networks add in parallel to give a constant input impedance as a function of frequency, with power flowing into one leg or the other of the filter pair. These filters can be cascaded to divide the band into the frequency ranges of interest; the broadband impedance matching at the inputs makes coupling of successive stages straightforward. These circuits can be produced in quantity at low cost using standard PCB fabrication techniques. We have determined that to achieve best performance the circuits should be built on a low loss-tangent RF substrate. We are working in cooperation with our colleagues in condensed matter who also have a need for this capability to purchase the equipment for in-house fabrication of prototype quantities of these circuits. We plan to continue the work on these filtersusing internal funds, and produce and characterize the performance of prototypes. We also participated in deployment of a prototype detector station near McMurdo Station, Antarctica in collaboration with colleagues at UCLA and UC-Irvine. The prototype station includes a single-board computer, GPS receiver, ADC board, and Iridium satellite modem powered by an omnidirectional solar array. We operated this station in the austral summer of 2006-2007, and used the Iridium SMS mode to transmit the status of the station until the end of the daylight season.

47 OTHER INSTRUMENTATION↗

DETECTING ACTIVE GALACTIC NUCLEI USING MULTI-FILTER IMAGING DATA. II. INCORPORATING ARTIFICIAL NEURAL NETWORKS

This is the second paper of the series Detecting Active Galactic Nuclei Using Multi-filter Imaging Data. In this paper we review shapelets, an image manipulation algorithm, which we employ to adjust the point-spread function (PSF) of galaxy images. This technique is used to ensure the image in each filter has the same and sharpest PSF, which is the preferred condition for detecting AGNs using multi-filter imaging data as we demonstrated in Paper I of this series. We apply shapelets on Canada-France-Hawaii Telescope Legacy Survey Wide Survey ugriz images. Photometric parameters such as effective radii, integrated fluxes within certain radii, and color gradients are measured on the shapelets-reconstructed images. These parameters are used by artificial neural networks (ANNs) which yield: photometric redshift with an rms of 0.026 and a regression R-value of 0.92; galaxy morphological types with an uncertainty less than 2 T types for z ≤ 0.1; and identification of galaxies as AGNs with 70% confidence, star-forming/starburst (SF/SB) galaxies with 90% confidence, and passive galaxies with 70% confidence for z ≤ 0.1. The incorporation of ANNs provides a more reliable technique for identifying AGN or SF/SB candidates, which could be very useful for large-scale multi-filter optical surveys that also include a modest set of spectroscopic data sufficient to train neural networks.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensitivity of Inferred Electron Temperature from X-ray Emission of NIF Cryogenic DT Implosions

The National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory seeks to achieve thermonuclear ignition through inertial confinement fusion. The accurate assessment of the performance of each implosion experiment is a crucial step. Here we report on work to derive a reliable electron temperature for the cryogenic deuteriumtritium implosions completed on the NIF using the xray signal from the Ross filter diagnostic. These Xrays are dominated by bremsstrahlung emission. By fitting the xray signal measured through each of the individual Ross filters, the source bremsstrahlung spectrum can be inferred, and an electron temperature of the implosion hot spot inferred. Currently, each filter is weighted equally in this analysis. We present work quantifying the errors with such a technique and the results from investigating the contribution of each filter to the overall accuracy of the temperature inference. Using this research, we also compare the inferred electron temperature against other measured implosion quantities to develop a more complete understanding of the hotspot physics.

42 ENGINEERING↗

Difficult OptEase Filter Retrievals After Prolonged Indwelling Times

PurposeThe OptEase vena cave filter (Cordis, Piscataway, NJ) is commercially available as a retrievable or permanent filter with short recommended indwelling time, presumably due to extensive contact of the filter side struts with the inferior vena cava wall and subsequent neointimal hyperplasia leading to incorporation. Our purpose was to evaluate OptEase filter retrievals with a long indwelling time period that required unconventional retrieval techniques.Materials and MethodsWe retrospectively reviewed patients who underwent OptEase filter retrieval with long undwelling times requiring additional maneuvers for retrieval. Techniques used included rigid endobronchial forceps dissection and wire-through-loop snare. Each patient underwent postretrieval venogram to evaluate for possible complications. In addition, patients had clinical follow-up 2 weeks after the retrieval procedure.ResultsThere were three patients (2 women, 1 man; average age 64 years) who underwent OptEase filter retrieval. The mean indwelling time was 6.4 months. The indwelling filters were successfully retrieved. There were no complications. Postprocedural follow-up showed no clinical pathology.ConclusionUnconventional techniques aided in the retrieval of OptEase filters with long indwelling times.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Series Resistance Measurements of Perovskite Solar Cells Using J sc – V oc Measurements

The fill factor (FF) of perovskite solar cells is considerably lower than that of gallium arsenide and silicon cells, though they have similar open–circuit voltage deficits. To probe the FF loss, which mainly comes from series resistance, the J sc –V oc characterization technique is applied to perovskite solar cells. A continuous–lamp solar simulator with an array of neutral density filters is used instead of the quasi–steady–state photoconductance technique commonly employed for silicon cells, which allows us to tune sweep parameters to accommodate the complex behavior of perovskites such as hysteresis. It is found that, for Cs 0.25 FA 0.75 Pb(Br 0.2 I 0.8 ) 3 (CsFA) perovskite cells, sweeping from positive to negative voltage yields the same series resistance regardless of sweep speed, whereas this is not the case if the sweep is reversed. However, for CH 3 NH 3 PbI 3 perovskite cells, the series resistance is independent of the sweep speed in both sweep directions. Furthermore, it is also found that, for a poly[bis(4–phenyl)(2,4,6–trimethylphenyl)amine] (PTAA) hole contact, increasing the PTAA thickness barely changes the recombination–limited pseudo–FF, but reduces the FF due to increased series resistance. A maximum FF of 80.9% was achieved with the PTAA hole contact on a CsFA perovskite absorber.

14 SOLAR ENERGY↗

Time-windows-based filtering method for near-surface detection of leakage from geologic carbon sequestration sites

We use process-based modeling techniques to characterize the temporal features of natural biologically controlled surface CO{sub 2} fluxes and the relationships between the assimilation and respiration fluxes. Based on these analyses, we develop a signal-enhancing technique that combines a novel time-window splitting scheme, a simple median filtering, and an appropriate scaling method to detect potential signals of leakage of CO{sub 2} from geologic carbon sequestration sites from within datasets of net near-surface CO{sub 2} flux measurements. The technique can be directly applied to measured data and does not require subjective gap filling or data-smoothing preprocessing. Preliminary application of the new method to flux measurements from a CO{sub 2} shallow-release experiment appears promising for detecting a leakage signal relative to background variability. The leakage index of ?2 was found to span the range of biological variability for various ecosystems as determined by observing CO{sub 2} flux data at various control sites for a number of years.

54 ENVIRONMENTAL SCIENCES↗

Covariance Spectroscopy for Fissile Material Detection

Nuclear fission produces multiple prompt neutrons and gammas at each fission event. The resulting daughter nuclei continue to emit delayed radiation as neutrons boil off, beta decay occurs, etc. All of the radiations are causally connected, and therefore correlated. The correlations are generally positive, but when different decay channels compete, so that some radiations tend to exclude others, negative correlations could also be observed. A similar problem of reduced complexity is that of cascades radiation, whereby a simple radioactive decay produces two or more correlated gamma rays at each decay. Covariance is the usual means for measuring correlation, and techniques of covariance mapping may be useful to produce distinct signatures of special nuclear materials (SNM). A covariance measurement can also be used to filter data streams because uncorrelated signals are largely rejected. The technique is generally more effective than a coincidence measurement. In this poster, we concentrate on cascades and the covariance filtering problem.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing x-ray transmission through filters used in high energy density physics diagnostics

We report on the design and implementation of a new system used to characterize the energy-dependent x-ray transmission curve, Θ(E), through filters used in high-energy density physics diagnostics. Using an Amptek X-123-CdTe x-ray spectrometer together with a partially depleted silicon surface barrier detector, both the energy spectrum and total emission of an x-ray source have been accurately measured. By coupling these detectors with a custom PROTO-XRD x-ray source with interchangeable cathodes, accurate characterizations of Θ(E) for filters of varying materials and thicknesses have been obtained. The validity of the technique has been confirmed by accurately reproducing areal densities for high-purity filters with known x-ray transmission properties. In this paper, the experimental setup is described and the results of absorption calibrations performed on a variety of different filters are presented.

47 OTHER INSTRUMENTATION↗

Characterizing x-ray transmission through filters used in high energy density physics diagnostics

We report on the design and implementation of a new system used to characterize the energy-dependent x-ray transmission curve, Θ(E), through filters used in high-energy density physics diagnostics. Using an Amptek X-123-CdTe x-ray spectrometer together with a partially depleted silicon surface barrier detector, both the energy spectrum and total emission of an x-ray source have been accurately measured. By coupling these detectors with a custom PROTO-XRD x-ray source with interchangeable cathodes, accurate characterizations of Θ(E) for filters of varying materials and thicknesses have been obtained. The validity of the technique has been confirmed by accurately reproducing areal densities for high-purity filters with known x-ray transmission properties. In this paper, the experimental setup is described and the results of absorption calibrations performed on a variety of different filters are presented.

Pearcy, J.↗