Search NASA⌕ Search

SEARCH · Search NASA

Results for “Follow the Water”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A simple model of fluid flow and electrolyte balance in the body

The model is basically a three-compartment model, the three compartments being the plasma, interstitial fluid and cellular fluid. Sodium, potassium, chloride and urea are the only major solutes considered explicitly. The control of body water and electrolyte distribution is affected via drinking and hormone levels. Basically, the model follows the effect of various oral input water loads on solute and water distribution throughout the body.

White, R. J.↗

Test results of a shower water recovery system

A shower test was conducted recently at NASA-JSC in which waste water was reclaimed and reused. Test subjects showered in a prototype whole body shower following a protocol similar to that anticipated for Space Station. The waste water was purified using reverse osmosis followed by filtration through activated carbon and ion exchange resin beds. The reclaimed waste water was maintained free of microorganisms by using both heat and iodine. This paper discusses the test results, including the limited effectiveness of using iodine as a disinfectant and the evaluation of a Space Station candidate soap for showering. In addition, results are presented on chemical and microbial impurity content of water samples obtained from various locations in the water recovery process.

Verostko, Charles E.↗

Using Resin to Reduce Silica in Borated Fluid - 20072

The Electric Power Research Institute (EPRI) strongly recommends the concentration of silica in the reactor coolant be limited, potential ingress be carefully controlled, and frequently monitored to assess potential silica deposits on fuel cladding surfaces. Boraflex is a product with silicone rubber encasing a neutron absorber for criticality control, and it was installed in the majority of nuclear power plant spent fuel pools. Over time and in the presence of radiation, the silicone rubber lining degrades into silica (SiO{sub 2}) and hydrogen gas. Silica is somewhat soluble in water and spent fuel pool water communicates with other plant systems during refueling outages, leading to a buildup of silica in the reactor coolant and connected systems. Due to the prevalence of Boraflex racks in spent fuel pools, the presence of silica is a chronic nuclear industry concern. To address this concern, many nuclear plants have installed reverse osmosis skid systems to remove the silica from their spent fuel pools and, by extension, from reactor coolant. These skids are expensive to install and maintain. Arcadis personnel demonstrated that an iron-impregnated resin could be used to remove silica from borated systems without impacting the water quality. The resin was readily available, inexpensive, and easy to install in existing plant equipment. During a nuclear power plant's refueling outage the iron-impregnated resin proved to be effective in reducing the need for feed and bleed operations, with concurrent cost savings and reduction in required outage water management activities. Thus, the following savings were realized: - Eliminated the need to purchase, install, and maintain a reverse osmosis system avoiding more than $10 million in up-front capital cost and ongoing operating and maintenance costs. - Removed 9.57 kilograms (21 pounds) of silica dioxide from the primary system fluid. - Reduced the volume of feed and bleed from 70,000 gallons (2.65 E+05 liters) to 35,000 gallons (1.32 E+05 liters). - Saved $380,000 in water production and disposal costs. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Land use change detection with LANDSAT-2 data for monitoring and predicting regional water quality degradation

The author has identified the following significant results. Comparison between LANDSAT 1 and 2 imagery of Arkansas provided evidence of significant land use changes during the 1972-75 time period. Analysis of Arkansas historical water quality information has shown conclusively that whereas point source pollution generally can be detected by use of water quality data collected by state and federal agencies, sampling methodologies for nonpoint source contamination attributable to surface runoff are totally inadequate. The expensive undertaking of monitoring all nonpoint sources for numerous watersheds can be lessened by implementing LANDSAT change detection analyses.

Macdonald, H.↗

Capillary Liquid Acquisition Device Heat Entrapment

Cryogenic liquid acquisition devices (LADs) for space-based propulsion interface directly with the feed system, which can be a significant heat leak source. Further, the accumulation of thermal energy within LAD channels can lead to the loss of subcooled propellant conditions and result in feed system cavitation during propellant outflow. Therefore, the fundamental question addressed by this program was: To what degree is natural convection in a cryogenic liquid constrained by the capillary screen meshes envisioned for LADs? Testing was first conducted with water as the test fluid, followed by LN2 tests. In either case, the basic experimental approach was to heat the bottom of a cylindrical column of test fluid to establish stratification patterns measured by temperature sensors located above and below a horizontal screen barrier position. Experimentation was performed without barriers, with screens, and with a solid barrier. The two screen meshes tested were those typically used by LAD designers, 200x1400 and 325x2300, both with Twill Dutch Weave. Upon consideration of both the water and LN2 data, it was concluded that heat transfer across the screen meshes was dependent upon barrier thermal conductivity and that the capillary screen meshes were impervious to natural convection currents.

Bolshinskiy, L. G.↗

Cryogenic Capillary Screen Heat Entrapment

Cryogenic liquid acquisition devices (LADs) for space-based propulsion interface directly with the feed system, which can be a significant heat leak source. Further, the accumulation of thermal energy within LAD channels can lead to the loss of sub-cooled propellant conditions and result in feed system cavitation during propellant outflow. Therefore, the fundamental question addressed by this program was: "To what degree is natural convection in a cryogenic liquid constrained by the capillary screen meshes envisioned for LADs.?"Testing was first conducted with water as the test fluid, followed by LN2 tests. In either case, the basic experimental approach was to heat the bottom of a cylindrical column of test fluid to establish stratification patterns measured by temperature sensors located above and below a horizontal screen barrier position. Experimentation was performed without barriers, with screens, and with a solid barrier. The two screen meshes tested were those typically used by LAD designers, "200x1400" and "325x2300", both with Twill Dutch Weave. Upon consideration of both the water and LN2 data it was concluded that heat transfer across the screen meshes was dependent upon barrier thermal conductivity and that the capillary screen meshes were impervious to natural convection currents.

Bolshinskiy, L.G.↗

Amino acid precursors in lunar samples.

The use of hot water to extract lunar samples, followed by the hydrolysis of the aqueous extract, appears to be the method of choice for identification and quantitation of amino acid precursors in extraterrestrial sources. The net inferences from the analyses to date are (1) that amino acid precursors are verifiably present in lunar dust, and (2) that they are quite certainly not the consequence of contamination by terrestrial organisms, including man. It is suggested that prebiotic evolutionary pathways such as have been traversed on the earth were terminated on the moon for lack of sufficient water. Although some or all of the amino acid precursors may be indigenous, the low level observed suggests that they may also result from onfall of organic compounds from interstellar matter, comets, tails, solar wind, or meteorites.

Fox, S. W.↗

Zeolite Membrane Reactor for Pre-Combustion Carbon Dioxide Capture (Final Scientific/Technical Report)

Water-gas shift (WGS) reaction followed by carbon dioxide (CO 2 ) separation is a critical step in the integrated gasification combined cycle (IGCC) process for fossil-fuel-fired electrical power generation with CO 2 capture. To intensify the IGCC process hydrogen-permselective zeolite membrane reactor offers promise to replace the conventional energy-intensive fixed-bed reactors and solvent-based CO 2 capture units. The objectives of this project were to develop a bench-scale zeolite membrane reactor (total membrane area: 932 cm 2 for a 21-tube membrane bundle) for the water-gas-shift reaction of raw syngas from an oxygen-blown coal-gasifier for H 2 production with simultaneous CO 2 separation at the capability of about 2 kilograms H 2 per day (equivalent to 2 kW IGCC power plant) and to demonstrate significant progress toward achieving overall performance goal of 90% CO 2 capture rate with 95% CO 2 purity at the cost of electricity 30% less than the baseline carbon capture approaches. This report summarizes results obtained in this project on scaling up the zeolite membrane reactor by a factor of 200 in membrane area, tests of the bench-scale zeolite membrane reactor for the water-gas-shift reaction at high temperature and high-pressure, and techno-economic analysis of the integration of the zeolite membrane reactor in IGCC power plant for the electrical generation with CO 2 capture. With effective pore modification by catalytic cracking deposition of MDES (methyldiethoxysilane), fabrication of MFI-type zeolite membranes was successfully scaled-up from a lab-scale disk type to bench-scale multiple-tube bundles on low-cost alumina supports. A Co-Mo based sour shift catalyst was evaluated and used in the zeolite membrane reactors for water-gas-shift reaction. The reaction kinetic and gas-permeation equations were developed and employed in mathematic models to guide/predict experiments/performance of zeolite membrane reactors for water-gas shift reaction. Multiple-tube zeolite membrane bundles and reactors were designed, fabricated and tested for gas separation and water-gas-shift reactions with real raw syngas from a coal-fired gasifier operated at high temperature and pressure. The zeolite membrane reactors demonstrated good long-term thermal and chemical stability and constant H 2 permeance (>300 GPU) together with a Knudsen selectivity (~4.7) for H 2 over CO 2 in the field test (cumulative time >28 hours) with high-sulfur coal-derived syngas. The zeolite-membrane-reactor integrated IGCC process was designed using the performance experimentally measured by the University of Cincinnati team with a single-tube zeolite membrane reactor that offers a CO conversion >98% with more than 90% of CO 2 and H 2 captured. With the above integrative approaches, a techno-economic analysis for a cost-benefit comparison was performed to uncover features that determine the power output, capital expenditure, operating expenditure, cost of electricity and cost of CO 2 capture in a 550-MW zeolite-membrane-reactor integrated IGCC process. The integration of the zeolite membrane reactor in IGCC could provide a significant reduction of 80% and 27% in the power consumption for Selexol™ Acid Gas Removal and CO 2 compression, respectively, which lowers the total auxiliary power consumption by 12.5%. However, the low pressure required at permeate stream for maintaining the driving force of hydrogen permeation through the zeolite membrane costs a huge power in permeate compressor, compensating the power consumption reduction achieved with the membrane reactor. Thus, for coal-fired IGCC for electricity generation with 90% CO 2 captured, the integration of the membrane reactor could provide a CO conversion ~99% and a significant drop in cost-of-electricity using zeolite membrane with H 2 permeance >600 GPU and the H 2 /CO 2 selectivity over 70.

01 COAL, LIGNITE, AND PEAT↗

Zeolite Membrane Reactor for Pre-Combustion Carbon Dioxide Capture

Water-gas shift (WGS) reaction followed by carbon dioxide (CO 2 ) separation is a critical step in the integrated gasification combined cycle (IGCC) process for fossil-fuel-fired electrical power generation with CO 2 capture. To intensify the IGCC process hydrogen-permselective zeolite membrane reactor offers promise to replace the conventional energy-intensive fixed-bed reactors and solvent-based CO 2 capture units. The objectives of this project were to develop a bench-scale zeolite membrane reactor (total membrane area: 932 cm 2 for a 21-tube membrane bundle) for the water-gas-shift reaction of raw syngas from an oxygen-blown coal-gasifier for H 2 production with simultaneous CO 2 separation at the capability of about 2 kilograms H 2 per day (equivalent to 2 kW IGCC power plant) and to demonstrate significant progress toward achieving overall performance goal of 90% CO 2 capture rate with 95% CO 2 purity at the cost of electricity 30% less than the baseline carbon capture approaches. This report summarizes results obtained in this project on scaling up the zeolite membrane reactor by a factor of 200 in membrane area, tests of the bench-scale zeolite membrane reactor for the water-gas-shift reaction at high temperature and high-pressure, and techno-economic analysis of the integration of the zeolite membrane reactor in IGCC power plant for the electrical generation with CO 2 capture.

20 FOSSIL-FUELED POWER PLANTS↗

Skylab study of water quality

The author has identified the following significant results. Analysis of S-190A imagery from 1 EREP pass over 3 reservoirs in Kansas establishes a strong linear correlation between the red/green radiance ratio and suspended solids. This result compares quite favorably to ERTS MSS CCT results. The linear fits RMS for Skylab is 6 ppm as compared to 12 ppm for ERTS. All of the ERTS satellite passes yielded fairly linear results with typical RMS values of 12 ppm. However, a few of the individual passes did yield RMS values of 5 or 6 ppm which is comparable to the one Skylab pass analyzed. In view of the cloudy conditions in the Skylab photos, yet good results, the indications are that S-190A may do somewhat better than the ERTS MSS in determining suspended load. More S-190A data is needed to confirm this. As was the case with the ERTS MSS, the Skylab S-190A showed no strong correlation with other water quality parameters. S-190B photos because of their high resolution can provide much first look information regarding relative degrees of turbidity within various parts of large lakes and among smaller bodies of water.

Yarger, H. L.↗

Microbial Challenge Testing of Single Liquid Cathode Feed Water Electrolysis Cells for the International Space Station (ISS) Oxygen Generator Assembly (OGA)

The International Space Station (ISS) Oxygen Generator Assembly (OGA) operational performance may be adversely impacted by microbiological growth and biofilm formation over the electrolysis cell membranes. Biofilms could hinder the transport of water from the bulk fluid stream to the membranes and increase the cell resistance resulting in higher cell voltages and a shorter cell life. A microbial challenge test was performed on duplicate single liquid cathode feed electrolyzer cells to evaluate operational performance with increasing levels of a mixture of five bacteria isolated from ISS and Space Shuttle potable water systems. Baseline performance of the single water electrolysis cells was determined for approximately one month with deionized water. Monthly performance was also determined following each inoculation of the feed tank with 100, 1000, 10,000 and 100,000 cells/ml of the mixed suspension of test bacteria. Water samples from the feed tank and recirculating water loops for each cell were periodically analyzed for enumeration and speciation of bacteria and total organic carbon. While initially a concern, this test program has demonstrated that the performance of the electrolysis cell is not adversely impacted by feed water containing the five species of bacteria tested at a concentration measured as high as 1,000,000 colony forming units (CFU)/ml. This paper presents the methodologies used in the conduct of this test program along with the performance test results at each level of bacteria concentration.

Diderich, Greg S.↗

Microbial Challenge Testing of Single Liquid Cathode Feed Water Electrolysis Cells for the International Space Station (ISS) Oxygen Generator Assembly (OGA)

The International Space Station (ISS) Oxygen Generator Assembly (OGA) operational performance may be adversely impacted by microbiological growth and biofilm formation over the electrolysis cell membranes. Biofilms could hinder the transport of water from the bulk fluid stream to the membranes and increase the cell concentration overpotential resulting in higher cell voltages and a shorter cell life. A microbial challenge test was performed on duplicate single liquid-cathode feed water electrolysis cells to evaluate operational performance with increasing levels of a mixture of five bacteria isolated from ISS and Space Shuttle potable water systems. Baseline performance of the single water electrolysis cells was determined for approximately one month with deionized water. Monthly performance was also determined following each inoculation of the feed tank with 100, 1000, 10,000 and 100,000 cells/ml of the mixed suspension of test bacteria. Water samples from the feed tank and recirculating water loops for each cell were periodically analyzed for enumeration and speciation of bacteria and total organic carbon. While initially a concern, this test program has demonstrated that the performance of the electrolysis cell is not adversely impacted by feed water containing the five species of bacteria tested at a concentration measured as high as 1,000,000 colony forming units (CFU)/ml. This paper presents the methodologies used in the conduct of this test program along with the performance test results at each level of bacteria concentration.

Roy, Robert J.↗

Soil pore network response to freeze-thaw cycles in permafrost aggregates

This dataset contains data used for the paper "Pore network response to freeze-thaw cycles in permafrost aggregates". The Related References field will be updated with a full citation when available.Climate change in Arctic landscapes may increase freeze-thaw frequency within the active layer as well as newly thawed permafrost. A highly disruptive process, freeze-thaw can deform soil pores and alter the architecture of the soil pore network with varied impacts to water transport and retention, redox conditions, and microbial activity. Our objective was to investigate how freeze-thaw cycles impacted the pore network of newly thawed permafrost aggregates to improve understanding of what type of transformations can be expected from warming Arctic landscapes. We measured the impact of freeze-thaw on pore morphology, pore throat diameter distribution, and pore connectivity with X-ray computed tomography (XCT) using six permafrost aggregates with sizes of 2.5 cm3 from a mineral soil horizon (Bw; 28-50 cm depths) in Toolik, Alaska. Freeze-thaw cycles were performed using a laboratory incubation consisting of five freeze-thaw cycles (-10˚C to 20˚C) over five weeks. Our findings indicated decreasing spatial connectivity of the pore network across all aggregates with higher frequencies of singly connected pores following freeze-thaw. Water-filled pores that were connected to the pore network decreased in volume while the overall connected pore volumetric fraction was not affected. Shifts in the pore throat diameter distribution were mostly observed in pore throats ranges of 100 microns or less with no corresponding changes to the pore shape factor of pore throats. Responses of the pore network to freeze-thaw varied with aggregate, suggesting that initial pore morphology may play a role in driving freeze-thaw response. Our research suggests that freeze-thaw alters the microenvironment of permafrost aggregates during the incipient stage of deformation following permafrost thaw, impacting soil properties and function in Arctic landscapes undergoing transition. This dataset contains a compressed (.zip) archive of the data and R scripts used for this manuscript. The dataset includes files in .csv format, which can be accessed and processed using MS Excel or R. This archive can also be accessed on GitHub at https://github.com/Erin-Rooney/XCT-freezethaw (DOI: 10.5281/zenodo.5816355).

54 ENVIRONMENTAL SCIENCES↗

A study of Minnesota land and water resources using remote sensing

The author has identified the following significant results. Both LANDSAT imagery and digital data were studied for usefulness in surveying water conditions of Minnesota lakes. Initial consideration was given to analysis of LANDSAT image densities because of the low technologic and cost requirements. The techniques employed, however, yield inconsistent and unreliable results. A set of criteria are given for using LANDSAT data in identification of three categories of particulate contaminants in Lake Superior. A linear transformation giving the relationship between the residual LANDSAT intensities and concentrations of three contaminants was obtained from correlation of remote sensing data with insitu measurements. LANDSAT imagery was found useful in placing peat bogs and fens in their respective geologic settings. Artificial disturbances and drainageways in peatlands could be recognized and classified.

Shepherd, W. G.↗

Subcritical crack growth in two titanium alloys.

Measurement of subcritical crack growth during static loading of precracked titanium alloys in salt water using samples too thin for plane strain loading to predominate was examined as a method for determining the critical stress intensity for crack propagation in salt water. Significant internal crack growth followed by arrest was found at quite low stress intensities, but crack growth rates were relatively low. Assuming these techniques provided a reliable measurement of the critical stress intensity, the value for annealed Ti-4Al-1.5Mo-0.5V alloy was apparently about 35 ksi-in. to the 1/2 power, while that for annealed Ti-4Al-3Mo-1V was below 45 ksi-in. to the 1/2 power. Crack growth was also observed in tests conducted in both alloys in an air environment. At 65 ksi-in. to the 1/2 power, the extent of crack growth was greater in air than in salt water. Ti-4Al-3Mo-1V showed arrested crack growth in air at a stress intensity of 45 ksi-in. to the 1/2 power.

Williams, D. N.↗

Water survey of Canada: Application for use of ERTS-A for retransmission of water resources data

The author has identified the following significant results. Over 7000 transmissions were received from six operating DCPs in 1972. Of these, only two were incorrect. One had the wrong date and the other had an invalid digit in the water level reading. Extensive checks have indicated that DCP data are accurate. The maximum number of transmissions received each day varies from 26 to 12 and the minimum from 10 to 3 depending on the site. Data has been received on as many as seven orbits in a day. The number of transmissions received from the two DCPs located in mountainous areas of southern B.C. is lower than the number received from more northerly but more open sites. The unheated DCPs have survived temperatures of -40 F and antenna loadings of two feet of snow and wind speeds over 50 mph. Two DCPs have indicated sensor malfunctions thus alerting field staff to the fact that repairs will be necessary on their next visit to the site. Also in another case, DCP data were used to fill in a period of missing record when a water level recorder malfunctioned for a few days.

Halliday, R. A.↗

Liquid Water on Early Mars

We have used a simple climate model to determine the duration of liquid water habitats on early Mars following up on the previous work of McKay and Davis. We used the weathering model of Pollack et al. to compute the pressure and temperature evolution of the atmosphere. We included the variability of the solar luminosity. Recent results which have considered the influence of CO2 condensation suggest that Mars could not have been kept warm (above 0 C) with only a dense CO2 atmosphere. New stellar evolution theories have suggested a more massive early sun to explain the lithium depletion in the sun and predict a warmer climate for early Mars. We have therefore modified the model of McKay and Davis to include the effects of CO2 condensation and the effect of a more massive early sun. Here we present the results of these additional effects on the duration of liquid water habitats on early Mars. We find that the increased luminosity suggested for the early sun when mass loss is taken into account can provide a climate on early Mars that results in fluvial features existing over 500 million years.

Davis, Wanda L.↗

The water factor in harvest-sprouting of hard red spring wheat

Sprouting in unthreshed, ripe, hard red spring wheat (Triticum aestivum L.) is induced by rain, but sprouting does not necessarily occur because the crop is wetted. The spike and grain water conditions conducive to sprouting were determined in a series of laboratory experiments. Sprouting did not occur in field growing wheat wetted to 110% water concentration until the spike water concentration was reduced to 12% and maintained at this concentration for 2 days before wetting. When cut at growth stage 11.3, Feekes scale, Saratovskaya 20 (USSR) sprouted after 4 days drying, Olaf and Alex between 7 and 15 days drying and Columbus, recognized for its resistance to harvest time sprouting, after more than 15 days drying. Sprouting potential was enhanced after 4 wetting drying cycles in which any wetted interval was too brief to permit sufficient water imbibition to initiate sprouting. At harvest ripeness, grain water concentration exceeded spike water concentration by 0.7 percentage units. Following 6 months storage, 20% of the kernels in 300 spike bundles (simulating windrows) sprouted within 28 hrs after initiation of wetting to saturation (150% water concentration). Ninety percent sprouting occurred within 8 days in bundles maintained at 75% water concentration and higher, but less sprouting occurred in bundles dried to 50% water concentration before resaturation.

Bauer, A.↗