Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA CAMERAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A Behavioral Robotics Approach to Radiation Mapping Using Adaptive Sampling

Radiation mapping is a desirable task to automate because of the inherent risks involved and its tedious nature. A novel system was designed to address this by combining various existing technologies, utilizing behavior-based robotics and Bayesian optimization. The system uses a quadruped robot equipped with a manipulator and gamma detector to take measurements at locations that are selected based on the uncertainty of a surrogate model used to estimate the true radiation field. The robot uses input from the world with depth cameras to avoid collisions with the robot’s body, and unreachable points for the end effector are addressed by both allowing for a soft collision with the environment to occur, prompting the system to abandon that point, and varying the exploration tendency of the optimization based on consecutive collisions. This approach provides unique traversability and adaptability over other strategies in the literature. Experiments were performed by placing a Cesium-137 source on the ground and varying geometric setups and an optimization parameter demonstrating the adaptability to diverse environments and the increased robustness resulting from the designed behavior. The results additionally demonstrate that dynamically adjusting the optimization algorithm’s exploration tendency based on the arm’s collision history improves the system’s ability to navigate cluttered environments and construct accurate radiation maps without getting stuck in unreachable areas.

Adams, Joel↗

Northern Hemisphere Gullies on Mars: Analysis of Spacecraft Data and Implications for Formation Mechanisms

The origin of geologically recent gullies on Mars has remained controversial since the discovery of these features by Malin and Edgett in 2000. Numerous models have been proposed which invoke various physical processes as well as various agents of erosion to explain the origin of the Martian gullies. Hypotheses to explain the formation of the gullies invoke shallow liquid water aquifers, deep liquid water aquifers, melting ground ice, snowmelt, dry landslides, and carbon dioxide aquifers. We test the validity of such gully formation mechanisms by analyzing data from the Mars Global Surveyor and Mars Odyssey spacecrafts to uncover trends in the dimensional and physical properties of the gullies and their surrounding terrain. A similar study has previously been completed for gullies located in the southern hemisphere of Mars. The work presented here focuses exclusively on gullies in the northern hemisphere based on the identification of 136 Mars Orbiter Camera (MOC) images containing clear evidence of gully landforms, distributed in the northern mid and high latitudes. These sites have been analyzed in combination with Mars Orbiter Laser Altimeter (MOLA), Thermal Emission Spectrometer (TES), and Gamma Ray Spectrometer (GRS) data to provide quantitative measurements of numerous gully characteristics. Parameters measured include apparent source depth and distribution, vertical and horizontal dimensions, slopes, compass orientations, near-surface ice content, and factors controlling present-day climatic conditions.

Heldmann, J. L.↗

SU-E-T-104: Development of 3 Dimensional Dosimetry System for Gamma Knife

Purpose: The aim of this study was to develop a new 3 dimensional dosimetry system to verify the dosimetric accuracy of Leksell Gamma Knife-Perfexion™ (LGK) (Elekta, Norcross, GA). Methods: We designed and manufactured a lightweight dosimetry instrument to be equipped with the head frame to LGK. It consists of a head phantom, a scintillator, a CCD camera and a step motor. The 10×10 cm2 sheet of Gd2O3;Tb phosphor or Gafchromic EBT3 film was located at the center of the 16 cm diameter hemispherical PMMA, the head phantom. The additional backscatter compensating material of 1 cm thick PMMA plate was placed downstream of the phosphor sheet. The backscatter plate was transparent for scintillation lights to reach the CCD camera with 1200×1200 pixels by 5.2 um pitch. With This equipment, 300 images with 0.2 mm of slice gap were acquired under three collimator setups (4mm, 8mm and 16mm), respectively. The 2D projected doses from 3D distributions were compared with the exposured film dose. Results: As all doses normalized by the maximum dose value in 16 mm setup, the relative differences between the equipment dose and film dose were 0.2% for 4mm collimator and 0.5% for 8mm. The acquisition of 300 images by the equipment took less than 3 minutes. Conclusion: The new equipment was verified to be a good substitute to radiochromic film, with which required more time and resources. Especially, the new methods was considered to provide much convenient and faster solution in the 3D dose acquisition for LGK.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron Beam Cherenkov Emission Measurements for Quality Assurance

Previously, we have studied the scintillation phenomenon that occurs when a proton beam is sent into a tank of water. This study aims to observe similar effects with an electron beam. Both proton and electron beams, as well as other forms of ionizing radiation, are an effective way to treat cancer patients as they kill malignant tumors through localized energy deposition. Quality assurance (QA) programs are required for Radiation therapy treatments to ensure that the patient treatment plan is safe and can achieve its objective. QA programs require measuring and validating that the proper dose is reaching the target accurately. High costs and inconveniences are two drawbacks of the time consuming current QA methods. The search for a new, user-friendly QA program has caused lights created in water under gamma ray, electron beam and proton beam exposure to be observed and had led to the proposal of several QA methods using this phenomena. Air scintillation under electron beam exposure has also been explored. This study measured the light produced by electron beams traveling through water using a cooled charged coupled device (CCD) camera and an optical spectrometer. Additionally, this study demonstrates how Cherenkov emissions of an electron beam in water could be utilized in the development of an alternative low-cost, efficient, and accurate QA process to verify the electron beam path.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo studies of medium-size telescope designs for the Cherenkov Telescope Array

In this paper, we present studies for optimizing the next generation of ground-based imaging atmospheric Cherenkov telescopes (IACTs). Results focus on mid-sized telescopes (MSTs) for CTA, detecting very high energy gamma rays in the energy range from a few hundred GeV to a few tens of TeV. We describe a novel, flexible detector Monte Carlo package, FAST (FAst Simulation for imaging air cherenkov Telescopes), that we use to simulate different array and telescope designs. The simulation is somewhat simplified to allow for efficient exploration over a large telescope design parameter space. We investigate a wide range of telescope performance parameters including optical resolution, camera pixel size, and light collection area. In order to ensure a comparison of the arrays at their maximum sensitivity, we analyze the simulations with the most sensitive techniques used in the field, such as maximum likelihood template reconstruction and boosted decision trees for background rejection. Choosing telescope design parameters representative of the proposed Davies–Cotton (DC) and Schwarzchild–Couder (SC) MST designs, we compare the performance of the arrays by examining the gamma-ray angular resolution and differential point-source sensitivity. We further investigate the array performance under a wide range of conditions, determining the impact of the number of telescopes, telescope separation, night sky background, and geomagnetic field. We find a 30–40% improvement in the gamma-ray angular resolution at all energies when comparing arrays with an equal number of SC and DC telescopes, significantly enhancing point-source sensitivity in the MST energy range. Finally, we attribute the increase in point-source sensitivity to the improved optical point-spread function and smaller pixel size of the SC telescope design.

42 ENGINEERING↗

Compressive sensing for nuclear security

Special nuclear material (SNM) detection has applications in nuclear material control, treaty verification, and national security. The neutron and gamma-ray radiation signature of SNMs can be indirectly observed in scintillator materials, which fluoresce when exposed to this radiation. A photomultiplier tube (PMT) coupled to the scintillator material is often used to convert this weak fluorescence to an electrical output signal. The fluorescence produced by a neutron interaction event differs from that of a gamma-ray interaction event, leading to a slightly different pulse in the PMT output signal. The ability to distinguish between these pulse types, i.e., pulse shape discrimination (PSD), has enabled applications such as neutron spectroscopy, neutron scatter cameras, and dual-mode neutron/gamma-ray imagers. In this research, we explore the use of compressive sensing to guide the development of novel mixed-signal hardware for PMT output signal acquisition. Effectively, we explore smart digitizers that extract sufficient information for PSD while requiring a considerably lower sample rate than conventional digitizers. Given that we determine the feasibility of realizing these designs in custom low-power analog integrated circuits, this research enables the incorporation of SNM detection into wireless sensor networks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MILLIMETER TRANSIENT POINT SOURCES IN THE SPTpol 100 SQUARE DEGREE SURVEY

The millimeter transient sky is largely unexplored, with measurements limited to follow-up of objects detected at other wavelengths. High-angular-resolution telescopes, designed for measurement of the cosmic microwave background (CMB), offer the possibility to discover new, unknown transient sources in this band—particularly the afterglows of unobserved gamma-ray bursts (GRBs). Here, we use the 10 m millimeter-wave South Pole Telescope, designed for the primary purpose of observing the CMB at arcminute and larger angular scales, to conduct a search for such objects. During the 2012–2013 season, the telescope was used to continuously observe a 100 deg{sup 2} patch of sky centered at R.A. 23{sup h}30{sup m} and decl. −55° using the polarization-sensitive SPTpol camera in two bands centered at 95 and 150 GHz. These 6000 hr of observations provided continuous monitoring for day- to month-scale millimeter-wave transient sources at the 10 mJy level. One candidate object was observed with properties broadly consistent with a GRB afterglow, but at a statistical significance too low ( p = 0.01) to confirm detection.

79 ASTRONOMY AND ASTROPHYSICS↗

Reaction Dynamics And Nuclear Structure Via Deep Inelastic Collisions With Heavy-Ions: Search For Particle-Vibration Couplings in {sup 49}Ca

The deep inelastic reaction (DIC){sup 48}Ca+{sup 64}Ni, at an energy approximately 2.5 times above the Coulomb barrier, was studied using the CLARA-PRISMA setup at the Laboratori Nazionali di Legnaro. Total cross sections and angular distributions, both energy integrated and associated to the population of selected excited states, are measured for the most intense reaction channels. The {gamma}-decay of the most intense reaction products is also studied. The use of angular distributions and polarization measurements of {gamma} transitions allows to firmly establish spin and parity of excited states. Both reaction and gamma spectroscopy studies demonstrate the relevance of DIC with heavy ions for the investigation of moderately neutron rich systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation sensitivity of silicon imaging sensors on missions to the outer planets.

Review of the results of an investigation of the magnitude of the degradation effects of radiation on the operating characteristics of camera tubes using silicon diode arrays in the space environment, and discussion of the radiation damage mechanisms concerned. The effects produced by bombardment of bare-silicon-diode arrays or vidicon tubes with 85-kV X rays, Cobalt 60 gamma rays, 1 MeV and 11 MeV electrons, 3 MeV and 142 MeV protons, and reactor neutrons are presented. Interference effects produced by radiation bombardment during operation of television tubes are investigated, and limiting fluxes of electrons and protons are given.

Brucker, G. J.↗

X-ray emission from high temperature plasmas

X-rays from a 25-hJ plasma focus apparatus were observed with pinhole cameras. The cameras consist of 0.4 mm diameter pinholes in 2 cm thick lead housing enclosing an X-ray intensifying screen at the image plane. Pictures recorded through thin aluminum foils or plastic sheets for X-ray energies sub gamma smaller than 15 keV show distributed X-ray emissions from the focussed plasma and from the anode surface. However, when thick absorbers are used, radial filamentary structure in the X-ray emission from the anode surface is revealed. Occasionally larger structures are observed in addition to the filaments. Possible mechanisms for the filamentary structure are discussed.

Harries, W. L.↗

X-Ray Emission from the Unidentified Gamma Ray Transient GRO J1838-0415 and X-Ray Localization of Gamma-Ray Transients near the Galactic Plane

The investigation was focused on studying the residual X-ray emission from possible counterparts of enigmatic gamma-ray transients near the Galactic plane. These sources (discovered by our group at Columbia) are highly variable gamma-ray sources with no radio-loud spectrally flat blazar in their approx 1 deg. diameter error box. BSAX Narrow Field Instruments pointed the gamma-ray error box of the prominent non-blazar Energetic Gamma Ray Experiment Telescope (EGRET) source GRO 1838-04 twice on April 17, 1997, and on April 20, 1997. Most of the EGRET error box was imaged and several faint X-ray sources were detected. BSAX Wide Field Camera data were also obtained for a variety of sources near the Galactic plane, including GRO J1838-04.

Tavani, Marco↗

Novel Platform for Digitization of Radiation Measurements, Decommissioning and Dismantling and Nuclear Waste Management - 18229

An innovative Platform for a seamless digitization of the information produced during the characterization of radioactive waste, contaminated objects, and in general radioprotection measurements has ben developed by CAEN SyS. The Platform is based on a spectroscopic handheld instrument integrating RFID technology, barcode reader, camera, voice recorder, and geo-localization, a selection of radiation tolerant RFID tags tested above 300 Gy integrated dose, ruggedized portable RFID readers and a secure database framework capable to collect data also from external sources such as gamma scanners and imaging systems. The Platform allows for real-time measurement of dose rate, radiation spectroscopy, tagging, tracking and inventorying of items. All data produced by the Platform are securely stored into the non-volatile memory of the RFID tags and in the database for both onsite and remote access to the information by operators. This paper presents the current development of the Platform and shows the advantages of such approach to achieve an easy yet reliable waste traceability, waste bagging optimization, and a structured methodology for radiation measurements, meeting an excellent quality control as increasingly required by Safety Authorities. Applications here envisaged and explored are dismantling and decontamination operations, radioprotection measurements and patrols, nuclear material management, safeguards and verification inspections. More in general, the Platform can address the needs of all plants, research laboratories and facilities that are looking to improve their Safety Standards, decrease operational costs, have a precise knowledge of the contaminated environment and objects as well as optimization for personnel dose minimization. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design Considerations Of A Compton Camera For Low Energy Medical Imaging

Development of a Compton camera for low energy medical imaging applications is underway. The ProSPECTus project aims to utilize position sensitive detectors to generate high quality images using electronic collimation. This method has the potential to significantly increase the imaging efficiency compared with mechanically collimated SPECT systems, a highly desirable improvement on clinical systems. Design considerations encompass the geometrical optimisation and evaluation of image quality from the system which is to be built and assessed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ASIC Scoping Study Final Report

This report documents the results and findings of a one-year scoping study investigating multichannel readout application specific integrated circuits (ASICs) for interfacing to, and processing data from, silicon photomultiplier (SiPM) arrays. We document ASIC desired and required specifications for four applications supporting national security mission areas: neutron radiography, associated particle imaging, and two versions of kinematic neutron imaging cameras. While each application has a few unique requirements that stress capability, there is generally good agreement among most. Two recently developed ASIC devices were evaluated in a system-like configuration by interfacing these to scintillator crystals exposed to gamma and neutron sources. The 64-channel ORNL device delivered functional capability while meeting most mission requirements for neutron radiography. The Nalu Scientific device, a 32-channel full waveform digitizer, did not demonstrate reliable neutron / gamma separation but it is unclear if this was an ASIC issue or problems with test setup or firmware. A literature survey of other commercial and academic ASICs was undertaken to with the conclusion that existing devices do not meet all requirements.

42 ENGINEERING↗

Observational evidence linking a quasar with an optical transient

We present evidence for the association of a quasi stellar object (QSO) with a bright optical transient (OT). A V = 20.6 mag QSO with redshift z = 1.78 has been found within the 38 seconds x 62 seconds error ellipse of a bright OT discovered on a Harvard Patrol Camera plate taken in 1905. The chance of finding a random QSO at V less than or equal to 20.6 mag within this area is estimated as approximately 0.5%. Although the OT is within the error circle of the gamma-ray burst (GRB) GB 910219 position determined from the WATCH experiment, the localization for this same event determined from the Third Interplanetary Network does not include the OT or the QSO. Whether the GRB is related to the OT/QSO or not, the probable association of a bright OT with a QSO is a discovery that warrants further investigation.

Vrba, F. J.↗

Gamma imaging and mapping advancements

The Savannah River National Lab (SRNL) in partnership with Los Alamos National Lab (LANL) developed an in-situ GrayQb™ radiation mapping device eliminating the need to remove the radiation sensitive phosphor storage plate (PSP) from the device for scanning between exposures. By incorporating a customized version of the LANL patented MiniMax camera-based PSP reader system into the GrayQb™ housing, the exposed PSP can now be read in-situ and digitally transmitted to a remote computer for viewing. The ability to generate radiation contour maps showing source locations and relative radiological levels present in an area has high utility for targeting clean-up efforts, maintaining worker ALARA, determining leak locations and radiological situational awareness. In-situ GrayQb™ reduces the number of required interactions with the device providing deployment cost savings, increasing personnel safety and removing human handling errors during the manual scan process. Additionally, by negating the need for an external scanner, the device becomes more mobile. Other upgrades to the device included identification of a more sensitive imaging medium and incorporation of a dual pinhole rendering the device physically capable of obtaining 3D images. Laboratory tests with Am-241 sources using a mockup of the in-situ GrayQ™, successfully demonstrated the ability to digitally capture radiation source information using the dual pinhole and camera-based PSP reader.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In Search of Short Gamma-ray Burst Optical Counterparts with the Zwicky Transient Facility

The Fermi Gamma-ray Burst Monitor (GBM) triggers on-board in response to∼40 short gamma-ray bursts (SGRBs) per year; however, their large localization regions have made the search for optical counterparts a challenging endeavour. We have developed and executed an extensive program with the wide field of view of the Zwicky Transient Facility (ZTF) camera, mounted on the Palomar 48 inch Oschin telescope (P48), to perform target-of-opportunity (ToO) observations on 10Fermi-GBM SGRBsduring 2018 and 2020-2021. Bridging the large sky areas with small field of view optical telescopesin order to track the evolution of potential candidates, we look for the elusive SGRB afterglows andkilonovae (KNe) associated with these high-energy events. No counterpart has yet been found, eventhough more than 10 ground based telescopes, part of the Global Relay of Observatories WatchingTransients Happen (GROWTH) network, have taken part in these efforts. The candidate selectionprocedure and the follow-up strategy have shown that ZTF is an efficient instrument for searchingfor poorly localized SGRBs, retrieving a reasonable number of candidates to follow-up and showingpromising capabilities as the community approaches the multi-messenger era. Based on the medianlimiting magnitude of ZTF, our searches would have been able to retrieve a GW170817-like event upto∼200 Mpc and SGRB afterglows to z = 0.16 or 0.4, depending on the assumed underlying energymodel. Future ToOs will expand the horizon to z = 0.2 and 0.7 respectively.

Tomas Ahumada↗

Imaging of gamma-Irradiated Regions of a Crystal

A holographic technique has been devised for generating a visible display of the effect of exposure of a photorefractive crystal to gamma rays. The technique exploits the space charge that results from trapping of electrons in defects induced by gamma rays. The technique involves a three-stage process. In the first stage, one writes a holographic pattern in the crystal by use of the apparatus shown in Figure 1. A laser beam of 532-nm wavelength is collimated and split into signal and reference beams by use of a polarizing beam splitter. On its way to the crystal, the reference beam goes through a two-dimensional optical scanner that contains two pairs of lenses (L1y, L2y and L1x,L2x) and mirrors M1 and M2, which can be rotated by use of micrometer drives to make fine adjustments. The signal beam is sent through a spatial light modulator that imposes the holographic pattern, then through two imaging lenses L(sub img) on its way to the crystal. An aperture is placed at the common focus of lenses Limg to suppress high-order diffraction from the spatial light modulator. The hologram is formed by interference between the signal and reference beams. A camera lens focuses an image of the interior of the crystal onto a charge-coupled device (CCD). If the crystal is illuminated by only the reference beam once the hologram has been formed, then an image of the hologram is formed on the CCD: this phenomenon is exploited to make visible the pattern of gamma irradiation of the crystal, as described next. In the second stage of the process, the crystal is removed from the holographic apparatus and irradiated with rays at a dose of about 100 krad. In the third stage of the process, the crystal is remounted in the holographic apparatus in the same position as in the first stage and illuminated with only the reference beam to obtain the image of the hologram as modified by the effect of the rays. The orientations of M1 and M2 can be adjusted slightly, if necessary, to maximize the intensity of the image. Figure 2 shows such an image that was formed in a crystal of Fe:LiNbO3.

Dragoi, Danut↗