Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gate selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Carbon dioxide in an ionic liquid: Structural and rotational dynamics

Ionic liquids (ILs), which have widely tunable structural motifs and intermolecular interactions with solutes, have been proposed as possible carbon capture media. In order to inform the choice of an optimal ionic liquid system, it can be useful to understand the details of dynamics and interactions on fundamental time scales (femtoseconds to picoseconds) of dissolved gases, particularly carbon dioxide (CO 2 ), within the complex solvation structures present in these uniquely organized materials. The rotational and local structural fluctuation dynamics of CO 2 in the room temperature ionic liquid 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide (EmimNTf2) were investigated by using ultrafast infrared spectroscopy to interrogate the CO 2 asymmetric stretch. Polarization-selective pump probe measurements yielded the orientational correlation function of the CO 2 vibrational transition dipole. It was found that reorientation of the carbon dioxide occurs on 3 time scales: 0.91 ± 0.03, 8.3 ± 0.1, 54 ± 1 ps. The initial two are attributed to restricted wobbling motions originating from a gating of CO 2 motions by the IL cations and anions. The final (slowest) decay corresponds to complete orientational randomization. Two-dimensional infrared vibrational echo (2D IR) spectroscopy provided information on structural rearrangements, which cause spectral diffusion, through the time dependence of the 2D line shape. Analysis of the time-dependent 2D IR spectra yields the frequency-frequency correlation function (FFCF). Polarization-selective 2D IR experiments conducted on the CO 2 asymmetric stretch in the parallel- and perpendicular-pumped geometries yield significantly different FFCFs due to a phenomenon known as reorientation-induced spectral diffusion (RISD), revealing strong vector interactions with the liquid structures that evolve slowly on the (independently measured) rotation time scales. To separate the RISD contribution to the FFCF from the structural spectral diffusion contribution, the previously developed first order Stark effect RISD model is reformulated to describe the second order (quadratic) Stark effect—the first order Stark effect vanishes because CO 2 does not have a permanent dipole moment. Through this analysis, we characterize the structural fluctuations of CO 2 in the ionic liquid solvation environment, which separate into magnitude-only and combined magnitude and directional correlations of the liquid’s time dependent electric field. This new methodology will enable highly incisive comparisons between CO 2 dynamics in a variety of ionic liquid systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and performance of a respiratory amplitude gating device for PET/CT imaging

Purpose: Recently, the authors proposed a free-breathing amplitude gating (FBAG) technique for PET/CT scanners. The implementation of this technique required specialized hardware and software components that were specifically designed to interface with commercial respiratory gating devices to generate the necessary triggers required for the FBAG technique. The objective of this technical note is to introduce an in-house device that integrates all the necessary hardware and software components as well as tracks the patient's respiratory motion to realize amplitude gating on PET/CT scanners. Methods: The in-house device is composed of a piezoelectric transducer coupled to a data-acquisition system in order to monitor the respiratory waveform. A LABVIEW program was designed to control the data-acquisition device and inject triggers into the PET list stream whenever the detected respiratory amplitude crossed a predetermined amplitude range. A timer was also programmed to stop the scan when the accumulated time within the selected amplitude range reached a user-set interval. This device was tested using a volunteer and a phantom study. Results: The results from the volunteer and phantom studies showed that the in-house device can detect similar respiratory signals as commercially available respiratory gating systems and is able to generate the necessary triggers to suppress respiratory motion artifacts. Conclusions: The proposed in-house device can be used to implement the FBAG technique in current PET/CT scanners.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rational design of a genetically encoded NMR zinc sensor

Elucidating the biochemical roles of the essential metal ion, Zn 2+ , motivates detection strategies that are sensitive, selective, quantitative, and minimally invasive in living systems. Fluorescent probes have identified Zn 2+ in cells but complementary approaches employing nuclear magnetic resonance (NMR) are lacking. Recent studies of maltose binding protein (MBP) using ultrasensitive 129 Xe NMR spectroscopy identified a switchable salt bridge which causes slow xenon exchange and elicits strong hyperpolarized 129 Xe chemical exchange saturation transfer (hyper-CEST) NMR contrast. To engineer the first genetically encoded, NMR-active sensor for Zn 2+ , we converted the MBP salt bridge into a Zn 2+ binding site, while preserving the specific xenon binding cavity. The zinc sensor (ZS) at only 1 μM achieved ‘turn-on’ detection of Zn 2+ with pronounced hyper-CEST contrast. This made it possible to determine different Zn 2+ levels in a biological fluid via hyper-CEST. ZS was responsive to low-micromolar Zn 2+ , only modestly responsive to Cu 2+ , and nonresponsive to other biologically important metal ions, according to hyper-CEST NMR spectroscopy and isothermal titration calorimetry (ITC). Protein X-ray crystallography confirmed the identity of the bound Zn 2+ ion using anomalous scattering: Zn 2+ was coordinated with two histidine side chains and three water molecules. Penta-coordinate Zn 2+ forms a hydrogen-bond-mediated gate that controls the Xe exchange rate. Metal ion binding affinity, 129 Xe NMR chemical shift, and exchange rate are tunable parameters via protein engineering, which highlights the potential to develop proteins as selective metal ion sensors for NMR spectroscopy and imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Global Event-identifier Module: A distributed digital approach to event-of-interest identification logic for physics experiments

The demands from current data acquisition systems are to acquire data from a large number of detectors (or signals) while providing a high throughput. This can be achieved by having some preprocessing capability in the data acquisition system so that it can identify the events of interest. Precise selection of events with minimal time for identification and preprocessing is an experimental challenge. To address this challenge, we have developed a ''Global Event-identifier Module'' (GEM) on the CAMAC platform, which can flexibly adapt to the experimental requirements and validate an event with minimal time. GEM is a single width CAMAC module capable of operating in a ''distributed'' data acquisition environment where multiple CAMAC crates (each with one GEM module) can be used to collect synchronized data from all the crates. Event-of-interest decision can be made on signals connected to different crates. Inter-GEM communication is via the ubiquitous ethernet (unshielded twisted pair, CAT5) cable. The event of interest is decided within 32 ns (excluding cable delay). Implementation is accomplished using field programmable gate array which enables greater flexibility for algorithm modifications and updates without hardware changes. GEM supports unified, distributed, and multi-strobe data acquisition, enabling higher throughput, with data collection from a large number of signals by selective reads of events of interest as determined by the experimenter while providing timestamped data of each event.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of left ventricular contraction patterns using gated SPECT MPI to predict cardiac resynchronization therapy response

Background: The U-shaped left ventricular (LV) contraction pattern, identified by MRI or echocardiography, is associated with improved CRT response. Gated SPECT MPI can measure both myocardial viability and mechanical dyssynchrony in a single scan. The aim of this study is to examine the relationship of the LV contraction pattern and the response of CRT in patients with left bundle branch block (LBBB). Methods: Fifty-eight patients who met CRT guidelines and who had pre-CRT MPI were enrolled. Myocardial segments with tracer uptake < 50% of maximum were considered as scar. The LV contraction pattern was considered as U-shaped or non-U-shaped (U-shaped has a block line in the direction of contraction propagation). CRT response was defined as an increase in left ventricular ejection fraction ≥ 5% after 6-month follow-up. Results: Twenty-eight patients (48%) had a U-shaped contraction pattern and thirty patients (52%) had a non-U-shaped contraction pattern. The U-shaped group showed a significantly higher response rate than the non-U-shaped group (90% vs. 57%; P = 0.005). By univariate and multivariate logistic regression analysis, the U-shaped pattern was an independent predictor of CRT response. Conclusion: Non-invasive gated SPECT MPI can characterize LV mechanical contraction patterns. A U-shaped contraction pattern identified is associated with improved CRT response. This may prove useful for improved patient selection for CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Random access quantum information processors using multimode circuit quantum electrodynamics

Qubit connectivity is an important property of a quantum processor, with an ideal processor having random access—the ability of arbitrary qubit pairs to interact directly. This a challenge with superconducting circuits, as state-of-the-art architectures rely on only nearest-neighbor coupling. Here, we implement a random access superconducting quantum information processor, demonstrating universal operations on a nine-qubit memory, with a Josephson junction transmon circuit serving as the central processor. The quantum memory uses the eigenmodes of a linear array of coupled superconducting resonators. We selectively stimulate vacuum Rabi oscillations between the transmon and individual eigenmodes through parametric flux modulation of the transmon frequency. Utilizing these oscillations, we perform a universal set of quantum gates on 38 arbitrary pairs of modes and prepare multimode entangled states, all using only two control lines. We thus achieve hardware-efficient random access multi-qubit control in an architecture compatible with long-lived microwave cavity-based quantum memories.

97 MATHEMATICS AND COMPUTING↗

Structural mechanisms of TRPV6 inhibition by ruthenium red and econazole

TRPV6 is a calcium-selective ion channel implicated in epithelial Ca 2+ uptake. TRPV6 inhibitors are needed for the treatment of a broad range of diseases associated with disturbed calcium homeostasis, including cancers. Here we combine cryo-EM, calcium imaging, and mutagenesis to explore molecular bases of human TRPV6 inhibition by the antifungal drug econazole and the universal ion channel blocker ruthenium red (RR). Econazole binds to an allosteric site at the channel’s periphery, where it replaces a lipid. In contrast, RR inhibits TRPV6 by binding in the middle of the ion channel’s selectivity filter and plugging its pore like a bottle cork. Despite different binding site locations, both inhibitors induce similar conformational changes in the channel resulting in closure of the gate formed by S6 helices bundle crossing. The uncovered molecular mechanisms of TRPV6 inhibition can guide the design of a new generation of clinically useful inhibitors.

59 BASIC BIOLOGICAL SCIENCES↗

Spin polarization engineering in 𝑑-wave altermagnets

Altermagnets host unconventional spin-polarized bands despite zero net magnetization, but controlling their spin structure remains challenging. Here, we theoretically propose a multifield approach to engineer spin polarization in 𝑑-wave altermagnets using gating, optical driving, and in-plane electric fields, which enable tunable and switchable polarizations along multiple directions. Optical driving induces out-of-plane (𝑧) polarization, while gating and in-plane fields generate 𝑥 and 𝑦 polarizations via the Edelstein effect, all of which are experimentally detectable. We further find that spin- and band-selective doping induces chiral optical activity, a feature unique to altermagnets. Our approach offers a versatile means to control the direction of spin polarization in altermagnets.

Floquet systems↗

Selective atomic layer deposition with electron-beam patterned self-assembled monolayers

The authors selectively deposited nanolines of titanium oxide (TiO{sub 2}) through atomic layer deposition (ALD) using an octadecyltrichlorosilane (OTS) self-assembled monolayer (SAM) as a nucleation inhibition layer. Electron-beam (e-beam) patterning is used to prepare nanoline patterns in the OTS SAM on SiO{sub 2}/Si substrates suitable for selective ALD. The authors have investigated the effect of an e-beam dose on the pattern width of the selectively deposited TiO{sub 2} lines. A high dose (e.g., 20 nC/cm) causes broadening of the linewidth possibly due to scattering, while a low dose (e.g., 5 nC/cm) results in a low TiO{sub 2} deposition rate because of incomplete exposure of the OTS SAMs. The authors have confirmed that sub-30 nm isolated TiO{sub 2} lines can be achieved by selective ALD combined with OTS patterned by EBL at an accelerating voltage of 2 kV and line dose of 10 nC/cm. This research offers a new approach for patterned gate dielectric layer fabrication, as well as potential applications for nanosensors and solar cells.

36 MATERIALS SCIENCE↗

New Developments in FPGA Devices: SEUs and Fail-Safe Strategies from the NASA Goddard Perspective

It has been shown that, when exposed to radiation environments, each Field Programmable Gate Array (FPGA) device has unique error signatures. Subsequently, fail-safe and mitigation strategies will differ per FPGA type. In this session several design approaches for safe systems will be presented. It will also explore the benefits and limitations of several mitigation techniques. The intention of the presentation is to provide information regarding FPGA types, their susceptibilities, and proven fail-safe strategies; so that users can select appropriate mitigation and perform the required trade for system insertion. The presentation will describe three types of FPGA devices and their susceptibilities in radiation environments.

Field Programmable Gate Array (FPGA)↗

Electron Density Measurements Using USPR (Final Scientific/Technical Report)

UC Davis has fabricated an ultrashort pulse reflectometer (USPR) diagnostic instrument for electron density profile measurements on compact, short duration, magnetically-confined fusion-energy concept devices such as spheromaks and FRCs. The USPR system transmits extremely short duration (~few nsec) chirped waveforms that together span 29 to 75 GHz. These chirped waveforms illuminate and reflect from the target plasma, with each frequency component reflecting from a different density layer (higher frequencies probe deeper into the plasma before reflecting). The reflected waveforms are split into roughly 42 different frequencies; time-of-flight (TOF) measurements made at each frequency with high resolution (~25 psec measurement resolution which corresponds to ~5 mm). These TOF data may then be inverted via software to generate electron density profiles with high time resolution (~10 μsec). At the heart of the system is a field programmable gate array (FPGA) based controller which collects and processes all of the USPR data in addition to generating all of the control signals required for maximum flexibility. The FPGA controller has the software flexibility to be easily reconfigured for different plasma devices, and the entire system sufficiently compact to be easily and quickly transported between devices. A high speed impulse generator was transformed into a set of three ultrashort pulse transmitter chirps using a combination of dispersive waveguide, frequency doublers and high-pass filters. A mm-wave controller was fabricated to sequentially switch between the three chirps, directing the chirps one-by-one to three different mm-wave assemblies spanning 29-75 GHz. Each mm-wave assembly consists of a high power active multiplier chain which converts the transmitter chirp to higher frequencies, and a broadband mixer which downconverts the reflected waveform to the 2-18 GHz range of the UPSR receiver. The 16-channel receiver (shared by all 3 mm-wave assemblies) was fabricated employing custom TOF modules capable of operating at a high 1 MHz sampling rate. Laboratory testing of the full system revealed the presence of unwanted harmonics from the multiplication process, with interference observed in the downconverted reflections at selected frequency channels that could not be completely filtered out. Additional interference effects arising from internal reflections within the mm-wave assemblies were minimized using a high-speed switch which served to “gate out” much of these reflections. The USPR diagnostic was transported and installed onto the HIT-SIU plasma device, becoming operational on 11/08/2022. Although designed to span 3 distinct mm-wave bands, the HIT-SIU plasmas at this time were sufficiently low density such that only the lowest of the three bands was likely to have strong plasma reflections. The system was then set to operate on only the lowest band (assembly #1), with data collected every 1 μsec rather than 3 μsec which would have been the case when cycling through all three bands. Connected to HIT-SIU, time-varying plasma reflections were observed on 9 of 16 possible frequency channels. Close examination of the data collected revealed issues previously unobserved in laboratory testing, associated with (a) reflections from the small aperture horns required for operation within the HIT-SIU device, and (b) a dependence of the recorded TOF with the threshold voltage of a given channel. Plans were made to address each of these issues before undertaking any future campaigns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Digital interface for bi-directional communication between a computer and a peripheral device

For transmission of data from the computer to the peripheral, the computer initially clears a flipflop which provides a select signal to a multiplexer. A data available signal or data strobe signal is produced while tht data is being provided to the interface. Setting of the flipflop causes a gate to provide to the peripherial a signal indicating that the interface has data available for transmission. The peripheral provides an acknowledge or strobe signal to transfer the data to the peripheral. For transmission of data from the peripheral to the computer, the computer presents the initially cleared flipflop. A data request signal from the peripheral indicates that the peripheral has data available for transmission to the computer. An acknowledge signal indicates that the interface is ready to receive data from the peripheral and to strobe that data into the interface.

Bond, H. H., Jr.↗

Customizable Digital Receivers for Radar

Compact, highly customizable digital receivers are being developed for the system described in 'Radar Interferometer for Topographic Mapping of Glaciers and Ice Sheets' (NPO-43962), NASA Tech Briefs, Vol. 31, No. 7 (August 2007), page 72. The receivers are required to operate in unison, sampling radar returns received by the antenna elements in a digital beam-forming (DBF) mode. The design of these receivers could also be adapted to commercial radar systems. At the time of reporting the information for this article, there were no commercially available digital receivers capable of satisfying all of the operational requirements and compact enough to be mounted directly on the antenna elements. A provided figure depicts the overall system of which the digital receivers are parts. Each digital receiver includes an analog-to-digital converter (ADC), a demultiplexer (DMUX), and a field-programmable gate array (FPGA). The ADC effects 10-bit band-pass sampling of input signals having frequencies up to 3.5 GHz. The input samples are demultiplexed at a user-selectable rate of 1:2 or 1:4, then buffered in part of the FPGA that functions as a first-in/first-out (FIFO) memory. Another part of the FPGA serves as a controller for the ADC, DMUX, and FIFO memory and as an interface between (1) the rest of the receiver and (2) a front-panel data port (FPDP) bus, which is an industry-standard parallel data bus that has a high data-rate capability and multichannel configuration suitable for DBF. Still other parts of the FPGA in each receiver perform signal-processing functions. The digital receivers can be configured to operate in a stand-alone mode, or in a multichannel mode as needed for DBF. The customizability of the receiver makes it applicable to a broad range of system architectures. The capability for operation of receivers in either a stand-alone or a DBF mode enables the use of the receivers in an unprecedentedly wide variety of radar systems.

Moller, Delwyn↗

CryoEM structures of the human CLC-2 voltage-gated chloride channel reveal a ball-and-chain gating mechanism

CLC-2 is a voltage-gated chloride channel that contributes to electrical excitability and ion homeostasis in many different tissues. Among the nine mammalian CLC homologs, CLC-2 is uniquely activated by hyperpolarization, rather than depolarization, of the plasma membrane. The molecular basis for the divergence in polarity of voltage gating among closely related homologs has been a long-standing mystery, in part because few CLC channel structures are available. Here, we report cryoEM structures of human CLC-2 at 2.46 – 2.76 Å, in the presence and absence of the selective inhibitor AK-42. AK-42 binds within the extracellular entryway of the Cl – -permeation pathway, occupying a pocket previously proposed through computational docking studies. In the apo structure, we observed two distinct conformations involving rotation of one of the cytoplasmic C-terminal domains (CTDs). In the absence of CTD rotation, an intracellular N-terminal 15-residue hairpin peptide nestles against the TM domain to physically occlude the Cl – -permeation pathway. This peptide is highly conserved among species variants of CLC-2 but is not present in other CLC homologs. Previous studies suggested that the N-terminal domain of CLC-2 influences channel properties via a “ball-and-chain” gating mechanism, but conflicting data cast doubt on such a mechanism, and thus the structure of the N-terminal domain and its interaction with the channel has been uncertain. Through electrophysiological studies of an N-terminal deletion mutant lacking the 15-residue hairpin peptide, we support a model in which the N-terminal hairpin of CLC-2 stabilizes a closed state of the channel by blocking the cytoplasmic Cl – -permeation pathway.

59 BASIC BIOLOGICAL SCIENCES↗

Instrumentation and Control Selection for the 12 GeV Hall-B Magnets at Jefferson Lab

Here, as part of the Jefferson Lab 12 GeV accelerator upgrade, the Experimental Physics Hall B detector system requires two superconducting magnets – a Torus and a Solenoid. The specifications required maximum space for the detectors which led to the choice of conduction cooling for each magnet. The Torus consists of 6 trapezoidal 'race-track'-type coils connected in series with an operating current of 3770 A. The Solenoid is an actively shielded 5 Tesla magnet consisting of 5 coils connected in series operating at 2416 A. Within the hall the two magnets are located in close proximity to each other and are surrounded by particle detectors. We describe the philosophy behind the instrumentation selection and control design that accounts for this proximity and other challenging working conditions. We describe the choice of sensor technologies, as well as the control and data acquisition methods. The magnet power and cryogenic control sub-systems are implemented using Allen Bradley Control Logix 1756-L72 Programmable Logic Controllers. Sensor instrumentation read-backs are routed into the PLC via National Instruments cRIO hardware (Field Programmable Gate Arrays or FPGA/RT application) using Jefferson Lab designed FPGA-based multi-sensor-excitation-chassis. Configuration, monitoring, and alarm handlers for the magnet systems are provided via an Experimental Physics Instrumentation & Control System interface (EPICS). Failure Modes and Effects Analysis (FMEA) and the requirement to monitor critical parameters during operation guided the selection of instrumentation and associated hardware. The design of the quench protection and voltage tap sub-systems was driven by the anticipated level of voltages developed during a magnet quench. The primary hard-wired quench detection and protection sub-system together with the secondary PLC-based protection sub-system is also discussed. The successful commissioning and subsequent performance of these magnets demonstrates the robustness of the design and implementation approach that was adopted by the Jefferson Lab team and serves as an excellent 'How To' guide for future projects of this size and complexity.

12 GeV↗

Three-Function Logic Gate Controlled by Analog Voltage

The figure is a schematic diagram of a complementary metal oxide/semiconductor (CMOS) electronic circuit that performs one of three different logic functions, depending on the level of an externally applied control voltage, V(sub sel). Specifically, the circuit acts as A NAND gate at V(sub sel) = 0.0 V, A wire (the output equals one of the inputs) at V(sub sel) = 1.0 V, or An AND gate at V(sub sel) = -1.8 V. [The nominal power-supply potential (VDD) and logic "1" potential of this circuit is 1.8 V.] Like other multifunctional circuits described in several prior NASA Tech Briefs articles, this circuit was synthesized following an automated evolutionary approach that is so named because it is modeled partly after the repetitive trial-and-error process of biological evolution. An evolved circuit can be tested by computational simulation and/or tested in real hardware, and the results of the test can provide guidance for refining the design through further iteration. The evolutionary synthesis of electronic circuits can now be implemented by means of a software package Genetic Algorithms for Circuit Synthesis (GACS) that was developed specifically for this purpose. GACS was used to synthesize the present trifunctional circuit. As in the cases of other multifunctional circuits described in several prior NASA Tech Briefs articles, the multiple functionality of this circuit, the use of a single control voltage to select the function, and the automated evolutionary approach to synthesis all contribute synergistically to a combination of features that are potentially advantageous for the further development of robust, multiple-function logic circuits, including, especially, field-programmable gate arrays (FPGAs). These advantages include the following: This circuit contains only 9 transistors about half the number of transistors that would be needed to obtain equivalent NAND/wire/AND functionality by use of components from a standard digital design library. If multifunctional gates like this circuit were used in the place of the configurable logic blocks of present commercial FPGAs, it would be possible to change the functions of the resulting digital systems within shorter times. For example, by changing a single control voltage, one could change the function of thousands of FPGA cells within nanoseconds. In contrast, typically, the reconfiguration in a conventional FPGA by use of bits downloaded from look-up tables via a digital bus takes microseconds.

Zebulum, Ricardo↗

A time-gating scintillation detector for the measurement of laser-induced fast neutrons

A time-gating scintillation detector, in which a fast high voltage switch is used for gating a channel photomultiplier, was developed for a measurement of laser-induced fast neutrons. The x rays generated from the intense femtosecond laser and the solid target interactions were suppressed selectively and a time-of-flight signal of a laser-generated fast neutron was measured effectively. The detector was used successfully to measure the neutron yield of a femtosecond, deuterated, polystyrene plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SiC MOSFET Based Modular Universal Power Electronics Regulator

A modular and scalable SiC MOSFET based universal power electronics regulator (UPER) allows coordinated integration of energy resources and loads, elimination of extra power conversion stages, and allowance of more sources or loads added with a simple plug and play feature. A comprehensive investigation has been conducted in term of the typical distributed generations and loads employed in buildings, in order to outline a detailed specification for UPER. Thus, a common DC bus voltage of 500 V and power rating of 3 kW are dedicatedly selected. The UPER hardware design and implementation are completely illustrated, including the static and dynamic characterization of the employed SiC MOSFET. The dedicated universal power cell and Plug-and-Play gate driver performs reliable continuous operation even exposed to an extreme fast switching speed (> 100 V/ns). The continuous operation of buck mode verified the UPER hardware development at 50 kHz with an overall efficiency of 98.19%. A new voltage polarity reversal phenomenon was also discovered in the verification of the isolated DAB stage with planar transformers.

Zheng, Sheng↗