Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTERROGATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Passive Confirmation of the Presence Of High-Explosive Material Via Neutron Transmission Spectroscopy

The goal of this project was to explore a novel approach for identifying presence and potential types of high explosives (HE) in treaty-controlled items with passive neutron sources by using passive neutron transmission spectroscopy. We predominantly look to measure relative elemental abundance of Carbon, Hydrogen, Oxygen, and Nitrogen (CHON) since most relevant materials are certain mix of these elements, as shown in Table 1. Previously, most studies exploring potential identification of CHON elemental content of targets in the vicinity of passive neutron source were focused solely on gamma spectroscopy using high resolution gamma detectors. Using neutron transmission spectroscopy with pulse-shape discrimination (PSD) capable organic scintillators is not only a novel idea in of itself, but arguably necessary for accurate identification of the CHON elemental content of an interrogated target. While high resolution gamma spectroscopy in principle can determine a presence of hydrogen and nitrogen, it is effectively blind to a quantitatively measuring areal densities of C, O. The initially proposed approach, described in detail in the project proposal, was to leverage previous Monte Carlo study on neutron transmission spectroscopy using slab shaped target interrogated with well-collimated (“pencil”) neutron beam. In this study, a simulated test CO 2 target was interrogated by a pencil neutron beam and transmitted neutron spectra were measured using PSD capable organic scintillator using MLEM based unfolding technique. To establish relative elemental content of carbon and oxygen, the unfolded neutron spectrum was fit with a parametrized combination of their respective elemental spectral templates. The individual spectral template was calculated by convoluting ENDF neutron crosssection with the known resolution of the PSD detector used in the study. This approach in the studied configuration successfully quantitatively established relative elemental composition of carbon and oxygen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of Deployed EDS Technologies

The term explosive detection system (EDS) is used by the TSA to describe equipment that is certified to detect explosives in checked bags. The EDS, as certified, by the TSL must consist of device for interrogating a bag and an automated detection algorithm (ATD) for evaluating the results of the interrogation. We only consider CT as the interrogation device in this report. A schematic drawing of a CT-based EDS is shown in Figure 2. The output of the ATD is the binary decision of alarm or non-alarm. Alarms may true- or false-positives. Non-alarms may be true- or false-negatives. False positives are also denoted false alarms. The true detection means that the ATD reports an alarm when a threat is present in the scanned bag. The probability of detecting a threat given that a threat is present is denoted the probability of detection (PD). The probability of false alarm (PFA) is the case when an alarm is reported when a threat is not present in a bag. Certification in this context means passing tests for PD and PFA at the TSL. The results of the EDS include CT cross-sectional images of the bag and specifics about the alarmed objects generated by ATD. These results are presented on a display so that a person may override the decision of ATD and declare the alarm to be a non-alarm. This process is denoted clearing. Bags that are not cleared by the person are sent to a secondary inspection process. Here the bags may be opened or assessed with explosive trace detection (ETD) in order to clear the bags. Bags that are not cleared at this point are evaluated by an ordinance disposal team. The CT scanner along with ATD is denoted Level 1 screening. The process of clearing on a display is denoted Level 2 screening. Secondary inspection is denoted Level 3 screening. Vendors of the deployed EDSs supply the TSA with equipment for all three levels. Therefore, the term EDS may include the equipment provided for Levels 1, 2 and 3. A schematic diagram of an EDS and the levels of screening are shown in Figure 7. The decision processes used as a bag is scanned and cleared is shown in Figure 8. Shield alarms and exceptions are discussed below. Since most alarms are false alarms, the probability of alarm is often times denoted the probability of a false alarm. The expenses associated with clearing false alarms occur in Levels 2 and 3.

42 ENGINEERING↗

Enrichment Determination of Uranium in Shielded Configurations

The determination of the enrichment of uranium is required in many safeguards and security applications. Typical methods of determining the enrichment rely on detecting the 186 keV gamma ray emitted by 235 U. In some applications, the uranium is surrounded by external shields, and removal of the shields is undesirable. In these situations, methods relying on the detection of the 186 keV gamma fail because the gamma ray is shielded easily. Oak Ridge National Laboratory (ORNL) has previously measured the enrichment of shielded uranium metal using active neutron interrogation. The method consists of measuring the time distribution of fast neutrons from induced fissions with large plastic scintillator detectors. To determine the enrichment, the measurements are compared to a calibration surface that is created from Monte Carlo simulations where the enrichment in the models is varied. In previous measurements, the geometry was always known. ORNL is extending this method to situations where the geometry and materials present are not known in advance. In the new method, the interrogating neutrons are both time and directionally tagged, and an array of small plastic scintillators measures the uncollided interrogating neutrons. Therefore, the attenuation through the item along many different paths is known. By applying image reconstruction techniques, an image of the item is created which shows the position-dependent attenuation. The image permits estimating the geometry and materials present, and these estimates are used as input for the Monte Carlo simulations. As before, simulations predict the time distribution of induced fission neutrons for different enrichments. Matching the measured time distribution to the closest prediction from the simulations provides an estimate of the enrichment. This presentation discusses the method and provides results from recent simulations that show the importance of knowing the geometry and materials from the imaging system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an instrument for non-destructive identification of Unexploded Ordnance using tagged neutrons - a proof of concept study

Range clearance operations at munitions testing grounds must discriminate Unexploded Ordnance (UXO) from clutter items and distinguish UXO filled with High Explosives (HE) from those with inert fillers. Non-destructive technologies are thus necessary for the cost-effective disposal of UXO during remediation of such sites. The only technique showing promise so far for the non-destructive elemental characterization of UXO fillers utilizes neutron interactions with the material to detect carbon (C), nitrogen (N) and oxygen (O) which have unique ratios in HE. However, several unresolved issues hinder the wide application of this potentially very suitable technique. The most important one is that neutrons interact with all surrounding matter in addition to the interrogated material, leading to a very high gamma-ray background in the detector. Systems requiring bulky shielding and having poor signal-to-noise ratios (SNRs) for measuring elements are unsuitable for field deployment. The inadequacies of conventional neutron interrogation methods are overcome by using the tagged-neutron approach, and the availability of compact sealed neutron generators exploiting this technique offers field deployment of non-intrusive measurement systems for detecting threat materials, like explosives and drugs. By accelerating deuterium ions into a tritium target, the subsequent fusion reaction generates nearly back-to-back emissions of neutrons and alpha particles of energy 14.1 and 3.5 MeV respectively. A position-sensitive detector recognizes the associated alpha particle, thus furnishing the direction of the neutron. The tagged neutrons interact with the nuclei of the interrogated object, producing element-specific prompt gamma-rays that the gamma detectors recognize. Measuring the delay between the detections of the alpha particle and the gamma-ray determines where the reaction occurred along the axis of the neutron beam (14.1 MeV neutrons travel at 5 cm/nanosecond, while gamma rays cover 30 cm/nanosecond). The main advantage of the technique is its ability to simultaneously provide 2D and 3D imaging of objects and their elemental composition. This work reports on the efficacy of using 14 MeV neutrons tagged by the associated particle neutron time-of-flight technique (APnTOF) to extract neutron induced characteristic gamma-rays from an object-of-interest with high SNR and without interference from nearby clutter.

54 ENVIRONMENTAL SCIENCES↗

Flow cytometer acquisition and detection system

A flow cytometer has a flow cell through which a sample flows and at least one laser emitting an excitation beam for illuminating a corresponding interrogation region in the flow cell. Scattered and fluorescence light from each interrogation region is collected by one or more input fibers for that region, and the input fiber(s) are fed to a dispersion module for that interrogation region that disperses the incoming light into different spectral regions. The dispersed light is conveyed, such as by a plurality of output fibers, to one or more photosensitive detectors. Thus, time multiplexed light signals may be delivered to a detector whereby several unique light signals can be measured by a single detector.

47 OTHER INSTRUMENTATION↗

Adaptive CT scanning system

Apparatus, systems, and methods that provide an X-ray interrogation system having a plurality of stationary X-ray point sources arranged to substantially encircle an area or space to be interrogated. A plurality of stationary detectors are arranged to substantially encircle the area or space to be interrogated, A controller is adapted to control the stationary X-ray point sources to emit X-rays one at a time, and to control the stationary detectors to detect the X-rays emitted by the stationary X-ray point sources.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gradiometer configuration invariant to laser phase noise and sensor rotations

A system for gravity measurement includes one or more atom sources, two or more laser beams, and a polarizing beamsplitter and a retro-reflection prism assembly. The one or more atom sources is to provide three ensembles of atoms. The two or more laser beams is to cool or interrogate the three ensembles of atoms. The polarizing beamsplitter and the retro-reflection prism assembly are in a racetrack configuration. The racetrack configuration routes the two or more laser beams in opposing directions around a loop topology, intersecting the three ensembles of atoms with appropriate polarizations chosen for cooling or interferometer interrogation. The three ensembles of atoms are positioned coaxially when interrogated.

47 OTHER INSTRUMENTATION↗

Apparatus and method for determining state of change (SOC) and state of health (SOH) of electrical cells

A method, an apparatus and a system for interrogating a battery in order to determine one or more of: (i) its state of charge (SOC), (ii) its state of health (SOH), (iii) physical state of one or more internal components or parts, which utilizes at least one sound source for transmitting a signal (e.g., a sound wave or sound pulse through or across the battery, and at least one sound receiver for receiving a signal from the battery, which received signal is representative of the physical state of the battery being interrogated. The interrogation method is noninvasive, namely does not require the depletion of a portion of the charge of the battery being tested or settlement or the destruction of the battery in order to evaluate one or more of (i), (ii) and (iii).

25 ENERGY STORAGE↗

Communication device and method of making the same

A communication device for receiving an interrogation signal at a first carrier frequency and for transmitting a response signal at a second carrier frequency is disclosed. The interrogation signal comprises the first carrier frequency modulated at the second carrier frequency. The communication device includes a sensor coupled to a demodulator. The sensor receives a low frequency input used to further modulate the interrogation signal. The demodulator demodulates the low frequency input from the first carrier frequency to thereby generate the response signal comprising the second carrier frequency and the low frequency input. The demodulator preferably includes a pyroelectric demodulator, a piezoelectric demodulator, or a detector diode. The demodulator preferably has a frequency response less than the first carrier frequency but greater than the second carrier frequency.

42 ENGINEERING↗

Dual frequency transceiver device

A transceiver device for receiving an interrogation signal at a first carrier frequency and for transmitting a response signal at a second carrier frequency is disclosed. The interrogation signal comprises the first carrier frequency modulated at the second carrier frequency. The communication device includes a sensor coupled to a demodulator. The sensor receives a low frequency input used to further modulate the interrogation signal. The demodulator demodulates the low frequency input from the first carrier frequency to thereby generate the response signal comprising the second carrier frequency and the low frequency input. The demodulator preferably includes a pyroelectric demodulator, a piezoelectric demodulator, or a detector diode. The demodulator preferably has a frequency response less than the first carrier frequency but greater than the second carrier frequency.

Brocato, Robert W.↗

Microwave diagnostics and passive sensors for pipeline, well-bore, and boiler-tube monitoring

Materials, methods of making, and methods of using an integrated wireless detector for real time interrogating metallic tubular structures comprising: an RF patch antenna; a passive surface acoustic wave (SAW) sensor; and data analytic methodologies. An embodiment relates to interrogating a metallic structure having a uniform cross section using an antenna which launches electromagnetic radiation. A sensor may be located within the structure is configured to re-emit electromagnetic radiation modified depending on parameters for which the sensor has been functionalized. An antenna may receive radiation as modified by the sensor, or may receive the transmitted or backscattered radiation directly, without use of a sensor. The antenna then communicates wirelessly with an interrogator providing data which may be used to understand the operational status of the structure in real-time.

Ohodnicki, Paul R.↗

Individually identifiable surface acoustic wave sensors, tags and systems

A surface-launched acoustic wave sensor tag system for remotely sensing and/or providing identification information using sets of surface acoustic wave (SAW) sensor tag devices is characterized by acoustic wave device embodiments that include coding and other diversity techniques to produce groups of sensors that interact minimally, reducing or alleviating code collision problems typical of prior art coded SAW sensors and tags, and specific device embodiments of said coded SAW sensor tags and systems. These sensor/tag devices operate in a system which consists of one or more uniquely identifiable sensor/tag devices and a wireless interrogator. The sensor device incorporates an antenna for receiving incident RF energy and re-radiating the tag identification information and the sensor measured parameter(s). Since there is no power source in or connected to the sensor, it is a passive sensor. The device is wirelessly interrogated by the interrogator.

Hines, Jacqueline H.↗

ADVANTG Results for a Proposed NDA System for Detecting Pin Diversion from SNF - Paper 120

This summary describes the results of applying the ADVANTG variance reduction parameter generator to accelerate continuous-energy Monte Carlo simulations of the {sup 252}Cf Interrogation with Prompt Neutron (CIPN) detection system proposed by Hu et al. for detecting the diversion of fuel elements from spent nuclear fuel (SNF) assemblies. In previous work, ADVANTG was applied to a suite of nine radiation detection, special nuclear material (SNM) movement detection, and safeguards test cases. That effort demonstrated that ADVANTG was able to provide large increases in tally figures of merit (FOMs) in nearly all of the cases without introducing bias into the Monte Carlo results. The objective of the work described here is to further evaluate ADVANTG, and also to identify gaps in capability with regard to nuclear safeguards applications, by applying the code to a challenging problem that is of a different nature from the ones previously studied. The CIPN nondestructive assay (NDA) system consists of three fission chambers embedded in a C-shaped block of polyethylene and a polyethylene-moderated {sup 252}Cf source that are placed on opposite sides of a subject SNF assembly. The idea of the detection system is to measure the difference between the background neutron count rate, due to spontaneous fission in the fuel material, and the count rate observed once the source is introduced, which is dominated by multiplication within the assembly. Based on the difference between these count rates, the fissile content of the assembly can be inferred, and this information can be used to determine if some fraction of the original fuel pins have been replaced with depleted uranium substitutes. The authors report that the system can detect the replacement of at least eight pins (3% of total mass). The ADVANTG code generates space- and energy-dependent weight-window bounds and biased source distributions based on approximate transport solutions that are efficiently generated by the Denovo 3-D discrete ordinates package. ADVANTG implements the Consistent Adjoint Driven Importance Sampling (CADIS) method for accelerating individual tallies and the Forward-Weighted CADIS (FW-CADIS) method for obtaining relatively uniform uncertainties across tallies over multiple regions and/or energy bins. The variance reduction parameters are generated in a format directly usable by standard versions of MCNP5 and MCNPX. In this work, the ADVANTG variance reduction parameter generator was applied to accelerate continuous energy MCNPX simulations of the {sup 252}Cf Interrogation with Prompt Neutron detection system for detecting the diversion of fuel elements from SNF assemblies. Variance reduction parameters generated with the existing version of ADVANTG actually slowed down tally convergence in all cases. The cause of the poor performance was found to be the lack of an induced fission source treatment in the fixed-source discrete ordinates calculations employed by ADVANTG. Because fission was treated as capture and not as a source, the importance maps generated by ADVANTG significantly underestimated the importance of thermal neutrons in and around the fuel elements. In order to obtain improved results, we developed an experimental implementation of a fission source outer iteration for the adjoint calculations. We used this prototype capability to generate new variance reduction parameters and found that the mean fission rates agreed well with those predicted by the conventional MCNPX simulations, as was expected. With these new parameters, speedup factors of 59 to 80 were obtained for the case with the background source, and factors of 17 to 24 were obtained for the cases with the interrogating source. These results demonstrate that a fission source treatment is needed to improve the effectiveness of ADVANTG in problems where the effects of induced fission are important. This includes many types of NDA problems that are relevant to safeguards applications. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved fission neutron energy discrimination with 4 He detectors through pulse filtering

Our paper presents experimental and computational techniques implemented for 4 He gas scintillation detectorsfor inducedfission neutron detection. Fission neutrons are produced when natural uranium samples are activelyinterrogated by 2.45 MeV deuterium-deuterium fusion reaction neutrons. Fission neutrons of energies greaterthan 2.45 MeV can be distinguished by their different scintillation pulse height spectra since 4 He detectorsretain incident fast neutron energy information. To enable the preferential detection of fast neutrons up to10 MeV and suppress low-energy event counts, the detector photomultiplier gain is lowered and triggerthreshold is increased. Pile-up and other unreliable events due to the interrogating neutronflux and backgroundradiation arefiltered out prior to the evaluation of pulse height spectra. With these problem-specific calibrationsand data processing, the 4 He detector's accuracy at discriminatingfission neutrons up to 10 MeV is improvedand verified with 252 Cf spontaneousfission neutrons. Given the 4 He detector's ability to differentiate fastneutron sources, this proof-of-concept active-interrogation measurement demonstrates the potential of specialnuclear materials detection using a 4 He fast neutron detection system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shielding a monoenergetic photon source for nonproliferation applications analysis

Near-monoenergetic photon sources offer appealing improvements over broad-band bremsstrahlung sources when applied to challenges in nonproliferation efforts. The use of a laser-plasma accelerator offers electrons at the energies needed for multi-MeV Thomson sources in a compact form factor. Because these electrons have energy up to approximately 0.5 GeV, many energetic photons and neutrons are created as they are dumped out of the beam line. This fact creates challenges for performing experiments to demonstrate the advantages of such a photon source for nonproliferation applications in the short term, until effective methods for decelerating the electrons are developed. To mitigate these background particles for laboratory measurements, a system of beam dumps and secondary collimators has been designed. Once background flux is reduced to the lowest practical level, it is compared to the expected flux created by the source photon beam on a lead target. This simulation mimics a nonproliferation application by predicting measured flux off-axis from an interrogated high-Z object as a surrogate for special nuclear material. Background mitigation techniques are also expanded to a mobile interrogation case. Furthermore, these methods allow for demonstration of nonproliferation applications of near-monoenergetic photon sources and future deployment in the field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wireless Patch Antenna Characterization for Live Health Monitoring Using Machine Learning

Temperature monitoring in extreme environments, such as coal-fired power plants, was addressed by designing and testing wireless patch antennas for use in machine learning-aided temperature estimation. The sensors were designed to monitor the temperature and health of boiler systems. Wireless interrogation of the sensor was performed using a Vector Network Analyzer (VNA) and a pair of interrogation antennas to capture resonance behavior under varying thermal and spatial conditions with sensitivities ranging from 0.052 to 0.20 $\frac{𝑀𝐻𝑧}{°C}$. Sensor calibration was conducted using a Long Short-Term Memory (LSTM) model, which leveraged temporal patterns to account for hysteresis effects. The calibration method demonstrated improved performance when combined with an LSTM model, achieving up to a 76% improvement in temperature estimation error when compared with Linear Regression (LR). The experiments highlighted an innovative solution for patch antenna-based non-contact temperature measurement, which addresses limitations with conventional methods such as RFID-based systems, infrared, and thermocouples.

20 FOSSIL-FUELED POWER PLANTS↗

Enhanced Photofission-based, Coincidence/Multiplicity Inspection Measurements

An enhanced active interrogation system has been developed that integrates a transportable Idaho National Laboratory (INL) photonuclear inspection system, using a pulsed bremsstrahlung source and a reconfigurable neutron detection system, with a Los Alamos National Laboratory (LANL) list-mode data acquisition system. A series of active interrogation experiments have shown enhanced nuclear material detection and identification utilizing pulsed photofission-induced, neutron coincidence/multiplicity counting between pulses of an up-to-10-MeV electron accelerator. This paper describes the integrated inspection system and presents some key shielded and unshielded nuclear material inspection results. The enhanced inspection methodology has applicability to homeland security and possible nuclear weapon dismantlement treaties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MPACT FY2011 Advanced Time-Correlated Measurement Research at INL

Simulations and experiments have been carried out to investigate advanced time-correlated measurement methods for characterizing and assaying nuclear material for safeguarding the nuclear fuel cycle. These activities are part of a project studying advanced instrumentation techniques in support of the U.S. Department of Energy's Fuel Cycle Research and Development program and its Materials Protection, Accounting, and Control Technologies (MPACT) program. For fiscal year 2011 work focused on examining the practical experimental aspects of using a time-tagged, associated-particle electronic neutron generator for interrogating low-enrichment uranium in combination with steady-state interrogation using a moderated 241Am-Li neutron source. Simulation work for the project involved the use of the MCNP-PoliMi Monte Carlo simulation tool to determine the relative strength and the time-of-flight energy spectra of different sample materials under irradiation. Work also took place to develop a post-processor parser code to extract comparable data from the MCNP5&6 codes. Experiments took place using a commercial deuterium-tritium associated-particle electronic neutron generator to irradiate a number of uranium-bearing material samples. Time-correlated measurements of neutron and photon signatures of these measurements were made using five liquid scintillator detectors in a novel array, using high-speed waveform digitizers for data collection. This report summarizes the experiments that took place in FY2011, presents preliminary analyses that have been carried out to date for a subpart of these experiments, and describes future activities planned in this area. The report also describes support Idaho National Laboratory gave to Oak Ridge National Laboratory in 2011 to facilitate 2-dimensional imagery of mixed-oxide fuel pins for safeguards applications as a part of the MPACT program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗