Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Combining Stereo SECCHI COR2 and HI1 Images for Automatic CME Front Edge Tracking

COR2 coronagraph images are the most commonly used data for coronal mass ejection (CME) analysis among the various types of data provided by the STEREO (Solar Terrestrial Relations Observatory) SECCHI (Sun-Earth Connection Coronal and Heliospheric Investigation) suite of instruments. The field of view (FOV) in COR2 images covers 215 solar radii (Rs) that allow for tracking the front edge of a CME in its initial stage to forecast the lead-time of a CME and its chances of reaching the Earth. However, estimating the lead-time of a CME using COR2 images gives a larger lead-time, which may be associated with greater uncertainty. To reduce this uncertainty, CME front edge tracking should be continued beyond the FOV of COR2 images. Therefore, heliospheric imager (HI1) data that covers 1590 Rs FOV must be included. In this paper, we propose a novel automatic method that takes both COR2 and HI1 images into account and combine the results to track the front edges of a CME continuously. The method consists of two modules: pre-processing and tracking. The pre-processing module produces a set of segmented images, which contain the signature of a CME, for both COR2 and HI1 separately. In addition, the HI1 images are resized and padded, so that the center of the Sun is the central coordinate of the resized HI1 images. The resulting COR2 andHI1 image set is then fed into the tracking module to estimate the position angle (PA) and track the front edge of a CME. The detected front edge is then used to produce a height-time profile that is used to estimate the speed of a CME. The method was validated using 15 CME events observed in the period from January 1, 2008 to August 31, 2009. The results demonstrate that the proposed method is effective for CME front edge tracking in both COR2 and HI1 images. Using this method, the CME front edge can now be tracked automatically and continuously in a much larger range, i.e., from 2 to 90 Rs, for the first time. These improvement scan greatly help in making the quantitative CME analysis more accurate and have the potential to assist in space weather forecasting.

Kirnosov, Vladimir↗

The Radiometric Scaling of the MODIS and VIIRS Imagers to a Common Reference and Stability Analysis for the Next Edition of CERES Products

The NASA CERES project has provided the climate quality observed TOA and computed surface fluxes to the scientific community. CERES uses MODIS and VIIRS imagers to retrieve cloud properties needed to convert Terra, Aqua, NPP, and NOAA-20 CERES footprint radiance observations into fluxes. The imagers are also used to radiometrically scale the geostationary sensors (GEO) radiances to the imager calibration reference to ensure that the GEO derived cloud properties and broadband TOA fluxes are consistent in both space and time. Both the imager and GEO retrieved cloud properties are used to compute the surface fluxes. The CERES imager and GEO calibration team uses ray-matched radiance pairs to radiometrically scale the SNPP and NOAA-20 VIIRS sensors to the Aqua-MODIS calibration reference. The radiometric scaling is further validated using geostationary imagers as transfer radiometers. The team will rely primarily on deep convective clouds to monitor the imager channel calibration stability and to correct for short term calibration drifts. The DSCOVR satellite was launched on February 25, 2015 and orbits around the L1 Lagrange point directly between the Earth and the sun. The EPIC sensor contains no onboard calibration systems. However, multiple inter-calibration studies have shown that the EPIC imager is very stable in time. The excellent radiometric stability of EPIC allows the use of EPIC observations as a stable reference to validate both the short term drift corrections of the imagers, as well as to validate the radiometric scaling factors between them. Examples of the imager relative calibration using EPIC before and after radiometric scaling will be shown along with the results from the use of invariant targets to remove imager calibration drifts.

DSCOVR-EPIC↗

Prediction and Evaluation of the Image of the WFIRST Coronagraph Pupil at the Shaped-Pupil Mask

To create a high contrast field of view with a shaped pupil coronagraph (SPC), the telescope pupil is imaged onto the shaped pupil mask, the shaped pupil mask is designed and fabricated through a design optimization based on a given pupil wavefront, and deformable mirrors (DM) in the coronagraph are modulated according to a nonlinear optimization procedure. Both the mask design optimization and the DM optimization require accurate knowledge of the image of the pupil at the shaped pupil plane for the calculation of Jacobians, and the evaluation of alignment tolerances. The shaped pupil coronagraphs demonstrated in the high contrast imaging testbed (HCIT) at JPL has heretofore assumed perfect imaging of the pupil onto the shaped pupil mask. Similarly, the design and performance modeling of the WFIRST CGI instrument makes the same assumption. In this paper we estimate and compare the image of the pupil mask at the shaped pupil plane in the case of the coronagraph testbed, and the image of the telescope pupil at the shaped pupil plane for the WFIRST CGI instrument. The estimated pupil images include field curvature and aberrations resulting from the layout of the parabolic mirror imaging system, which is optimized for the source image, not the image of the pupil. We also show the results of direct measurement of the image of the pupil mask at the shaped pupil plane in the coronagraph testbed.

Crowther, Blake↗

Image processing for improved eye-tracking accuracy

Video cameras provide a simple, noninvasive method for monitoring a subject's eye movements. An important concept is that of the resolution of the system, which is the smallest eye movement that can be reliably detected. While hardware systems are available that estimate direction of gaze in real-time from a video image of the pupil, such systems must limit image processing to attain real-time performance and are limited to a resolution of about 10 arc minutes. Two ways to improve resolution are discussed. The first is to improve the image processing algorithms that are used to derive an estimate. Off-line analysis of the data can improve resolution by at least one order of magnitude for images of the pupil. A second avenue by which to improve resolution is to increase the optical gain of the imaging setup (i.e., the amount of image motion produced by a given eye rotation). Ophthalmoscopic imaging of retinal blood vessels provides increased optical gain and improved immunity to small head movements but requires a highly sensitive camera. The large number of images involved in a typical experiment imposes great demands on the storage, handling, and processing of data. A major bottleneck had been the real-time digitization and storage of large amounts of video imagery, but recent developments in video compression hardware have made this problem tractable at a reasonable cost. Images of both the retina and the pupil can be analyzed successfully using a basic toolbox of image-processing routines (filtering, correlation, thresholding, etc.), which are, for the most part, well suited to implementation on vectorizing supercomputers.

NASA Discipline Space Human Factors↗

Report on the AAPM grand challenge on deep generative modeling for learning medical image statistics

Abstract Background The findings of the 2023 AAPM Grand Challenge on Deep Generative Modeling for Learning Medical Image Statistics are reported in this Special Report. Purpose The goal of this challenge was to promote the development of deep generative models for medical imaging and to emphasize the need for their domain‐relevant assessments via the analysis of relevant image statistics. Methods As part of this Grand Challenge, a common training dataset and an evaluation procedure was developed for benchmarking deep generative models for medical image synthesis. To create the training dataset, an established 3D virtual breast phantom was adapted. The resulting dataset comprised about 108 000 images of size 512 512. For the evaluation of submissions to the Challenge, an ensemble of 10 000 DGM‐generated images from each submission was employed. The evaluation procedure consisted of two stages. In the first stage, a preliminary check for memorization and image quality (via the Fréchet Inception Distance [FID]) was performed. Submissions that passed the first stage were then evaluated for the reproducibility of image statistics corresponding to several feature families including texture, morphology, image moments, fractal statistics, and skeleton statistics. A summary measure in this feature space was employed to rank the submissions. Additional analyses of submissions was performed to assess DGM performance specific to individual feature families, the four classes in the training data, and also to identify various artifacts. Results Fifty‐eight submissions from 12 unique users were received for this Challenge. Out of these 12 submissions, 9 submissions passed the first stage of evaluation and were eligible for ranking. The top‐ranked submission employed a conditional latent diffusion model, whereas the joint runners‐up employed a generative adversarial network, followed by another network for image superresolution. In general, we observed that the overall ranking of the top 9 submissions according to our evaluation method (i) did not match the FID‐based ranking, and (ii) differed with respect to individual feature families. Another important finding from our additional analyses was that different DGMs demonstrated similar kinds of artifacts. Conclusions This Grand Challenge highlighted the need for domain‐specific evaluation to further DGM design as well as deployment. It also demonstrated that the specification of a DGM may differ depending on its intended use.

Radiology, Nuclear Medicine & Medical Imaging↗

Qualitative and quantitative effects of harmonic echocardiographic imaging on endocardial edge definition and side-lobe artifacts

Harmonic imaging is a new ultrasonographic technique that is designed to improve image quality by exploiting the spontaneous generation of higher frequencies as ultrasound propagates through tissue. We studied 51 difficult-to-image patients with blinded side-by-side cineloop evaluation of endocardial border definition by harmonic versus fundamental imaging. In addition, quantitative intensities from cavity versus wall were compared for harmonic versus fundamental imaging. Harmonic imaging improved left ventricular endocardial border delineation over fundamental imaging (superior: harmonic = 71.1%, fundamental = 18.7%; similar: 10.2%; P <.001). Quantitative analysis of 100 wall/cavity combinations demonstrated brighter wall segments and more strikingly darker cavities during harmonic imaging (cavity intensity on a 0 to 255 scale: fundamental = 15.6 +/- 8.6; harmonic = 6.0 +/- 5.3; P <.0001), which led to enhanced contrast between the wall and cavity (1.89 versus 1.19, P <.0001). Harmonic imaging reduces side-lobe artifacts, resulting in a darker cavity and brighter walls, thereby improving image contrast and endocardial delineation.

NASA Discipline Cardiopulmonary↗

Delta-Doped Back-Illuminated CMOS Imaging Arrays: Progress and Prospects

In this paper, we report the latest results on our development of delta-doped, thinned, back-illuminated CMOS imaging arrays. As with charge-coupled devices, thinning and back-illumination are essential to the development of high performance CMOS imaging arrays. Problems with back surface passivation have emerged as critical to the prospects for incorporating CMOS imaging arrays into high performance scientific instruments, just as they did for CCDs over twenty years ago. In the early 1990's, JPL developed delta-doped CCDs, in which low temperature molecular beam epitaxy was used to form an ideal passivation layer on the silicon back surface. Comprising only a few nanometers of highly-doped epitaxial silicon, delta-doping achieves the stability and uniformity that are essential for high performance imaging and spectroscopy. Delta-doped CCDs were shown to have high, stable, and uniform quantum efficiency across the entire spectral range from the extreme ultraviolet through the near infrared. JPL has recently bump-bonded thinned, delta-doped CMOS imaging arrays to a CMOS readout, and demonstrated imaging. Delta-doped CMOS devices exhibit the high quantum efficiency that has become the standard for scientific-grade CCDs. Together with new circuit designs for low-noise readout currently under development, delta-doping expands the potential scientific applications of CMOS imaging arrays, and brings within reach important new capabilities, such as fast, high-sensitivity imaging with parallel readout and real-time signal processing. It remains to demonstrate manufacturability of delta-doped CMOS imaging arrays. To that end, JPL has acquired a new silicon MBE and ancillary equipment for delta-doping wafers up to 200mm in diameter, and is now developing processes for high-throughput, high yield delta-doping of fully-processed wafers with CCD and CMOS imaging devices.

imagers↗

Image registration for accurate electrode deformation analysis in operando microscopy of battery materials

Operando imaging techniques have become increasingly valuable in both battery research and manufacturing. However, the reliability of these methods can be compromised by instabilities in the imaging setup and operando cells, particularly when utilizing high-resolution imaging systems. The acquired imaging data often include features arising from both undesirable system vibrations and drift, as well as the scientifically relevant deformations occurring in the battery sample during cell operation. For meaningful analysis, it is crucial to distinguish and separately evaluate these two factors. To address these challenges, we employ a suite of advanced image-processing techniques. These include fast Fourier transform analysis in the frequency domain, power spectrum-based assessments for image quality, as well as rigid and non-rigid image-registration methods. These techniques allow us to identify and exclude blurred images, correct for displacements caused by motor vibrations and sample holder drift and, thus, prevent unwanted image artifacts from affecting subsequent analyses and interpretations. Additionally, we apply optical flow analysis to track the dynamic deformation of battery electrode materials during electrochemical cycling. This enables us to observe and quantify the evolving mechanical responses of the electrodes, offering deeper insights into battery degradation. Together, these methods ensure more accurate image analysis and enhance our understanding of the chemomechanical interplay in battery performance and longevity.

Sun, Tianxiao↗

Automated matching of pairs of SIR-B images for elevation mapping

During the SIR-B mission in October 1984, a significant number of overlapping synthetic aperture radar (SAR) images of various ground areas was collected. This has offered the first opportunity to perform stereo analyses on images from space that cover large ground areas to determine elevation information. This paper presents the preliminary results of an investigation to obtain elevation data from stereo pairs of SIR-B images. First, the accuracy with which elevation information can be derived from SIR-B image pairs is evaluated theoretically. It is shown that elevation accuracy is a function of the slant range resolution, the incidence angles with which the stereo pair is obtained, the accuracies in spacecraft state estimation, and determination of corresponding pixels in the stereo pair. Next, a hierarchical method is developed to match the corresponding pixels. This method involves iterative removal of local distortions and correlations of pairs of local neighborhoods in the two images. Since it is necessary to perform the matching at every pixel in the image, it is very computationally intensive. Therefore, it has been implemented on the Massively Parallel Processor (MPP) at the Goddard Space Flight Center (GSFC). The MPP's speed permits two iterations of this technique to operate on a pair of 512 x 512 images within 7 s. Results of applying this algorithm of SIR-B images of Mount Shasta, CA, are shown. The matching algorithm performs well in regions of the image with significant features. An approximate elevation image derived from the matching process corresponds to published topographic map data, except for certain obvious discontinuities.

Ramapriyan, H. K.↗

Calibrating AIS images using the surface as a reference

A method of evaluating the initial assumptions and uncertainties of the physical connection between Airborne Imaging Spectrometer (AIS) image data and laboratory/field spectrometer data was tested. The Tuscon AIS-2 image connects to lab reference spectra by an alignment to the image spectral endmembers through a system gain and offset for each band. Images were calibrated to reflectance so as to transform the image into a measure that is independent of the solar radiant flux. This transformation also makes the image spectra directly comparable to data from lab and field spectrometers. A method was tested for calibrating AIS images using the surface as a reference. The surface heterogeneity is defined by lab/field spectral measurements. It was found that the Tuscon AIS-2 image is consistent with each of the initial hypotheses: (1) that the AIS-2 instrument calibration is nearly linear; (2) the spectral variance is caused by sub-pixel mixtures of spectrally distinct materials and shade, and (3) that sub-pixel mixtures can be treated as linear mixtures of pure endmembers. It was also found that the image can be characterized by relatively few endmembers using the AIS-2 spectra.

Smith, M. O.↗

Autonomous image data reduction by analysis and interpretation

Image data is a critical component of the scientific information acquired by space missions. Compression of image data is required due to the limited bandwidth of the data transmission channel and limited memory space on the acquisition vehicle. This need becomes more pressing when dealing with multispectral data where each pixel may comprise 300 or more bytes. An autonomous, real time, on-board image analysis system for an exploratory vehicle such as a Mars Rover is developed. The completed system will be capable of interpreting image data to produce reduced representations of the image, and of making decisions regarding the importance of data based on current scientific goals. Data from multiple sources, including stereo images, color images, and multispectral data, are fused into single image representations. Analysis techniques emphasize artificial neural networks. Clusters are described by their outlines and class values. These analysis and compression techniques are coupled with decision making capacity for determining importance of each image region. Areas determined to be noise or uninteresting can be discarded in favor of more important areas. Thus limited resources for data storage and transmission are allocated to the most significant images.

Eberlein, Susan↗

Autonomous image data reduction by analysis and interpretation

Image data is a critical component of the scientific information acquired by space missions. Compression of image data is required due to the limited bandwidth of the data transmission channel and limited memory space on the acquisition vehicle. This need becomes more pressing when dealing with multispectral data where each pixel may comprise 300 or more bytes. An autonomous, real time, on-board image analysis system for an exploratory vehicle such as a Mars Rover is developed. The completed system will be capable of interpreting image data to produce reduced representations of the image, and of making decisions regarding the importance of data based on current scientific goals. Data from multiple sources, including stereo images, color images, and multispectral data, are fused into single image representations. Analysis techniques emphasize artificial neural networks. Clusters are described by their outlines and class values. These analysis and compression techniques are coupled with decision-making capacity for determining importance of each image region. Areas determined to be noise or uninteresting can be discarded in favor of more important areas. Thus limited resources for data storage and transmission are allocated to the most significant images.

Eberlein, Susan↗

Kalman filter based range estimation for autonomous navigation using imaging sensors

Rotorcraft operating in high-threat environments fly close to the surface of the earth to utilize surrounding terrain, vegetation, or man-made objects to minimize the risk of being detected by the enemy. Two basic requirements for obstacle avoidance are detection and range estimation of the object from the current rotorcraft position. There are many approaches to the estimation of range using a sequence of images. The approach used in this analysis differes from previous methods in two significant ways: an attempt is not made to estimate the rotorcraft's motion from the images; and the interest lies in recursive algorithms. The rotorcraft parameters are assumed to be computed using an onboard inertial navigation system. Given a sequence of images, using image-object differential equations, a Kalman filter (Sridhar and Phatak, 1988) can be used to estimate both the relative coordinates and the earth coordinates of the objects on the ground. The Kalman filter can also be used in a predictive mode to track features in the images, leading to a significant reduction of search effort in the feature extraction step of the algorithm. The purpose is to summarize early results obtained in extending the Kalman filter for use with actual image sequences. The experience gained from the application of this algorithm to real images is very valuable and is a necessary step before proceeding to the estimation of range during low-altitude curvilinear flight. A simple recursive method is presented to estimate range to objects using a sequence of images. The method produces good range estimates using real images in a laboratory set up and needs to be evaluated further using several different image sequences to test its robustness. The feature generation part of the algorithm requires further refinement on the strategies to limit the number of features (Sridhar and Phatak, 1989). The extension of the work reported here to curvilinear flight may require the use of the extended Kalman filter.

Sridhar, Banavar↗

Infrared images of merging galaxies

Infrared imaging of interacting galaxies is especially interesting because their optical appearance is often so chaotic due to extinction by dust and emission from star formation regions, that it is impossible to locate the nuclei or determine the true stellar distribution. However, at near-infrared wavelengths extinction is considerably reduced, and most of the flux from galaxies originates from red giant stars that comprise the dominant stellar component by mass. Thus near infrared images offer the opportunity to study directly components of galactic structure which are otherwise inaccessible. Such images may ultimately provide the framework in which to understand the activity taking place in many of the mergers with high Infrared Astronomy Satellite (IRAS) luminosities. Infrared images have been useful in identifying double structures in the nuclei of interacting galaxies which have not even been hinted at by optical observations. A striking example of this is given by the K images of Arp 220. Graham et al. (1990) have used high resolution imaging to show that it has a double nucleus coincident with the radio sources in the middle of the dust lane. The results suggest that caution should be applied in the identification of optical bright spots as multiple nuclei in the absence of other evidence. They also illustrate the advantages of using infrared imaging to study the underlying structure in merging galaxies. The authors have begun a program to take near infrared images of galaxies which are believed to be mergers of disk galaxies because they have tidal tails and filaments. In many of these the merger is thought to have induced exceptionally luminous infrared emission (cf. Joseph and Wright 1985, Sanders et al. 1988). Although the optical images of the galaxies show spectacular dust lanes and filaments, the K images all have a very smooth distribution of light with an apparently single nucleus.

Wright, G. S.↗

Analysis of objects in binary images

Digital image processing techniques are typically used to produce improved digital images through the application of successive enhancement techniques to a given image or to generate quantitative data about the objects within that image. In support of and to assist researchers in a wide range of disciplines, e.g., interferometry, heavy rain effects on aerodynamics, and structure recognition research, it is often desirable to count objects in an image and compute their geometric properties. Therefore, an image analysis application package, focusing on a subset of image analysis techniques used for object recognition in binary images, was developed. This report describes the techniques and algorithms utilized in three main phases of the application and are categorized as: image segmentation, object recognition, and quantitative analysis. Appendices provide supplemental formulas for the algorithms employed as well as examples and results from the various image segmentation techniques and the object recognition algorithm implemented.

Leonard, Desiree M.↗

An operational method for estimating signal to noise ratios from data acquired with imaging spectrometers

A method, using the concept of local means and local standard deviations of small imaging blocks and using a box counting procedure, has been developed for unsupervised estimation of the average signal to noise ratios of images in which the noise is additive. The method has been applied to simulated images with Gaussian noise, to images acquired with the Airborne Visible Infrared Imaging Spectrometer and with the Geophysical and Environmental Research Imaging Spectrometer. The method is compared with other techniques for estimating signal to noise ratios from imaging data. It is believed that the method is generally applicable to images having many small homogeneous blocks. Because the method does not take into account interband effects, it is not appropriate to use the method to estimate signal to noise ratios from images having nonnegligible interband radiometric calibration errors at spatial scales less than or equal to the size of the small imaging blocks used in the noise estimation.

Gao, Bo-Cai↗

A summary of image segmentation techniques

Machine vision systems are often considered to be composed of two subsystems: low-level vision and high-level vision. Low level vision consists primarily of image processing operations performed on the input image to produce another image with more favorable characteristics. These operations may yield images with reduced noise or cause certain features of the image to be emphasized (such as edges). High-level vision includes object recognition and, at the highest level, scene interpretation. The bridge between these two subsystems is the segmentation system. Through segmentation, the enhanced input image is mapped into a description involving regions with common features which can be used by the higher level vision tasks. There is no theory on image segmentation. Instead, image segmentation techniques are basically ad hoc and differ mostly in the way they emphasize one or more of the desired properties of an ideal segmenter and in the way they balance and compromise one desired property against another. These techniques can be categorized in a number of different groups including local vs. global, parallel vs. sequential, contextual vs. noncontextual, interactive vs. automatic. In this paper, we categorize the schemes into three main groups: pixel-based, edge-based, and region-based. Pixel-based segmentation schemes classify pixels based solely on their gray levels. Edge-based schemes first detect local discontinuities (edges) and then use that information to separate the image into regions. Finally, region-based schemes start with a seed pixel (or group of pixels) and then grow or split the seed until the original image is composed of only homogeneous regions. Because there are a number of survey papers available, we will not discuss all segmentation schemes. Rather than a survey, we take the approach of a detailed overview. We focus only on the more common approaches in order to give the reader a flavor for the variety of techniques available yet present enough details to facilitate implementation and experimentation.

Spirkovska, Lilly↗

Identification of an interstellar oxide grain from the Murchison meteorite by ion imaging

We report here the first use of a new ion-imaging system to locate a rare interstellar aluminum oxide grain in a Murchison acid residue. While several types of carbon-rich interstellar grains, including graphite, diamond, SiC, and TiC, have previously been found, isotopically anomalous interstellar oxide grains have proven more elusive. We have developed an ion imaging system which allows us to map the isotopic composition of large numbers of grains relatively quickly and is, thus, ideally suited to search for isotopically exotic subsets of grains. The system consists of a PHOTOMETRICS CCD camera coupled to the microchannel plate/fluorescent screen of the WU modified CAMECA IMS-3F ion microprobe. Isotopic images of the sample surface are focused on the CCD and digitized. Subsequent image processing identifies individual grains in the images and determines isotopic ratios for each. For the present work, we have imaged in O-16 and O-18; negligible contributions of (17)OH(-) and (16)OH2(-) signals to the O-18 signal allow the use of low mass resolution, simplifying the measurements. Repeated imaging runs on terrestrial corundum particles showed that the system measures isotopic ratios reproducibly to about +/- 40%. Each imaging run took about six minutes to complete, and for this study there were on average 5-15 grains in each image. We have conducted imaging searches in 2-4 micron size separates of both Orgueil and Murchison.

Nittler, L. R.↗