Search NASA⌕ Search

SEARCH · Search NASA

Results for “Infrared techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Large area QNDE inspection for airframe integrity

Quantitative Nondestructive Evaluation (QNDE) technology is being developed to provide new options for cost effective inspection of airframes. An R&D effort based on five NDE technologies is addressing questions of structural bonding assessment, corrosion detection, multisite damage detection, and fatigue characterization. The research/applications are being conducted by prioritized focussing and staging of the following technologies: (1) thermal NDE; (2) ultrasonic NDE; (3) coherent optical NDE; (4) magnetic imaging NDE; and (5) radiographic NDE. The focus here is on the most recent applications of thermal NDE technology to large area inspection of lap-joint and stiffener bonds. The approach is based on pulsed radiant heating of the airframe and measurement of the surface temperature of the structure with an infrared imager. Several advantages of the technique are that it is noncontacting, inspects one square meter area in a period of less than 2 minutes and has no difficulty inspecting typical curvatures of the fuselage. Numerical models of heat flow in these geometries are used to determine appropriate techniques for reduction of the infrared images, thereby delineating regions of disbonds. These models are also used to determine the optimum heating and measurement times for maximizing the contrast between bonded and unbonded structures. Good agreement is found between these results and experimental measurements, and a comparison of the two are presented. Also presented are results of measurements on samples with fabricated defects which show the technique is able to clearly indicate regions of disbonds. Measurements on an airframe also clearly image subsurface structure.

Winfree, William P.↗

Imaging of dark line defect growth in high-power diode laser cavities using broadband near infrared light emission from the laser cavity

An in situ and nondestructive technique is developed to image the formation and evolution of dark line defects in the cavity of a high-power diode laser. Here, the technique uses broadband near infrared emission that originates in the laser's core layers and enables defects to be imaged with high spatial resolution through the substrate. In particular, it enables defect imaging through the substrate of shorter wavelength lasers, even when the substrate is opaque near the lasing wavelength. The evolution of dark line defects during aging is studied in several devices, with correlations established between the observed characteristics of defect growth and changes in device parameters such as optical power, operating wavelength, threshold current, and slope efficiency. Gradual degradation is found to be associated with dark line defects that slowly propagate from dark spots that are present in the device interior in its fresh (unaged) condition, rather than propagating from spots that are formed during aging, suggesting a strategy to screen fresh devices for expected reliability. This defect growth phenomenon is found to be particularly evident in the dark spots near the output facet.

47 OTHER INSTRUMENTATION↗

Far-infrared embedding impedance measurements

A technique which allows the measurement of detector embedding impedance has been developed. By using a bismuth microbolometer as a variable resistance load the impedance of one element in a bow-tie antenna array operating at 94 GHz was inferred. The technique is frequency insensitive, and could be used throughout the far-infrared.

Neikirk, D. P.↗

Detection of Ice Polar Stratospheric Clouds from Assimilation of Atmospheric Infrared Sounder Data

A novel technique is presented for detection of ice polar stratospheric clouds (PSCs) that form at extremely low temperatures in the lower polar stratosphere during winter. Temperature is a major factor in determining abundance of PSCs, which in turn provide surfaces for heterogeneous chemical reactions leading to ozone loss and radiative cooling. The technique infers the presence of ice PSCs using radiances from the Atmospheric Infrared Sounder (AIRS) in the Goddard Earth Observing System version 5 (GEOS-5) data assimilation system. Brightness temperatures are computed from short-term GEOS-5 forecasts for several hundred AIRS channels, using a radiation transfer module. The differences between collocated AIRS observations and these computed values are the observed-minus-forecast (O-F) residuals in the assimilation system. Because the radiation model assumes clear-sky conditions, we hypothesize that these O-F residuals contain quantitative information about PSCs. This is confirmed using sparse data from the Polar Ozone and Aerosol Measurement (POAM) III occultation instrument. The analysis focuses on 0-F residuals for the 6.79pm AIRS moisture channel. At coincident locations, when POAM III detects ice clouds, the AIRS O-F residuals for this channel are lower than -2K. When no ice PSCs are evident in POAM III data, the AIRS 0-F residuals are larger. Given this relationship, the high spatial density of AIRS data is used to construct maps of regions where 0-F residuals are lower than -2K, as a proxy for ice PSCs. The spatial scales and spatio-temporal variations of these PSCs in the Antarctic and Arctic are discussed on the basis of these maps.

Stajner, Ivanka↗

Femtosecond measurements of near-infrared pulse induced mid-infrared transmission modulation of quantum cascade lasers

We temporally resolved the ultrafast mid-infrared transmission modulation of quantum cascade lasers (QCLs) using a near-infrared pump/mid-infrared probe technique at room temperature. Two different femtosecond wavelength pumps were used with photon energy above and below the quantum well (QW) bandgap. The shorter wavelength pump modulates the mid-infrared probe transmission through interband transition assisted mechanisms, resulting in a high transmission modulation depth and several nanoseconds recovery lifetime. In contrast, pumping with a photon energy below the QW bandgap induces a smaller transmission modulation depth but much faster (several picoseconds) recovery lifetime, attributed to intersubband transition assisted mechanisms. The latter ultrafast modulation (>60 GHz) could provide a potential way to realize fast QCL based free space optical communication.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synchrotron Infrared Confocal Microspectroscopical Detection of Heterogeneity Within Chemically Modified Single Starch Granules

This reports the first detection of chemical heterogeneity in octenyl succinic anhydride modified single starch granules using a Fourier transform infrared (FT-IR) microspectroscopical technique that combines diffraction-limited infrared microspectroscopy with a step size that is less than the mask projected spot size focused on the plane of the sample. The high spatial resolution was achieved with the combination of the application of a synchrotron infrared source and the confocal image plane masking system of the double-pass single-mask Continuum{reg_sign} infrared microscope. Starch from grains such as corn and wheat exists in granules. The size of the granules depends on the plant producing the starch. Granules used in this study typically had a median size of 15 {micro}m. In the production of modified starch, an acid anhydride typically is reacted with OH groups of the starch polymer. The resulting esterification adds the ester carbonyl (1723 cm{sup -1}) organic functional group to the polymer and the hydrocarbon chain of the ester contributes to the CH{sub 2} stretching vibration to enhance the intensity of the 2927 cm{sup -1} band. Detection of the relative modifying population on a single granule was accomplished by ratioing the baseline adjusted peak area of the carbonyl functional group to that of a carbohydrate band. By stepping a confocally defined infrared beam as small as 5 {micro}m x 5 {micro}m across a starch granule 1 {micro}m at a time in both the x and y directions, the heterogeneity is detected with the highest possible spatial resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Geobotanical discrimination of ultramafic parent materials An evaluation of remote sensing techniques

Color and color infrared aerial photography and imagery acquired from a Daedalus DEI-1260 multispectral airborne scanner were employed in an investigation to discriminate ultramafic rock types in a test site in southwest Oregon. An analysis of the relationships between vegetation characteristics and parent materials was performed using a vegetation classification and map developed for the project, lithologic information derived from published geologic maps of the region, and terrain information gathered in the field. Several analytical methods, including visual image analysis, band ratioing, principal components analysis, and contrast enhancement and subsequent color composite generation were used in the investigation. There was a close correspondence between vegetation types and major rock types. These were readily discriminated by the remote sensing techniques. It was found that ultramafic rock types were separable from non-ultramafic rock types and serpentine was distinguishable from non-serpentinized peridotite. Further investigations involving spectroradiometric and digital classification techniques are being performed to further identify rock types and to discriminate chromium and nickel-bearing rock types.

Mouat, D. A.↗

Convective heating measurement by means of an infrared camera

The development of rapid and accurate wind tunnel techniques to measure convective heating distributions in complex reentry configurations is discussed. Major emphasis was put on the infrared camera technique. Its essence is the measurement of infrared emission from the surface of a wind tunnel model as a function of time. Prior calibration of the infrared camera relates the emission to the surface temperature of the model. The time history of the surface temperature can then be related to the heating rate by standard techniques. The output of the camera is an electrical signal that is tape-recorded in analog form, then digitized and processed by computer, so that automated and relatively rapid data reduction can be accomplished. In addition, the camera produces real-time visual displays of the infrared emission as pictures on an oscilloscope screen. These pictures give immediate indications of hot and cool spots on the model.

Compton, D. L.↗

Compositional and textural information from the dual inversion of visible, near and thermal infrared remotely sensed data

A technique is presented that allows extraction of compositional and textural information from visible, near and thermal infrared remotely sensed data. Using a library of both emissivity and reflectance spectra, endmember abundances and endmember thermal inertias are extracted from AVIRIS (Airborne Visible and Infrared Imaging Spectrometer) and TIMS (Thermal Infrared Mapping Spectrometer) data over Lunar Crater Volcanic Field, Nevada, using a dual inversion. The inversion technique is motivated by upcoming Mars Observer data and the need for separation of composition and texture parameters from sub pixel mixtures of bedrock and dust. The model employed offers the opportunity to extract compositional and textural information for a variety of endmembers within a given pixel. Geologic inferences concerning grain size, abundance, and source of endmembers can be made directly from the inverted data. These parameters are of direct relevance to Mars exploration, both for Mars Observer and for follow-on missions.

Brackett, Robert A.↗

PRIMUS: INFRARED AND X-RAY AGN SELECTION TECHNIQUES AT 0.2 < z < 1.2

We present a study of Spitzer/IRAC and X-ray active galactic nucleus (AGN) selection techniques in order to quantify the overlap, uniqueness, contamination, and completeness of each. We investigate how the overlap and possible contamination of the samples depend on the depth of both the IR and X-ray data. We use Spitzer/IRAC imaging, Chandra and XMM-Newton X-ray imaging, and spectroscopic redshifts from the PRism MUlti-object Survey to construct galaxy and AGN samples at 0.2 < z < 1.2 over 8 deg{sup 2}. We construct samples over a wide range of IRAC flux limits (SWIRE to GOODS depth) and X-ray flux limits (10 ks to 2 Ms). We compare IR-AGN samples defined using both the IRAC color selection of Stern et al. and Donley et al. with X-ray-detected AGN samples. For roughly similar depth IR and X-ray surveys, we find that {approx}75% of IR-selected AGNs are also identified as X-ray AGNs. This fraction increases to {approx}90% when comparing against the deepest X-ray data, indicating that at most {approx}10% of IR-selected AGNs may be heavily obscured. The IR-AGN selection proposed by Stern et al. suffers from contamination by star-forming galaxies at various redshifts when using deeper IR data, though the selection technique works well for shallow IR data. While similar overall, the IR-AGN samples preferentially contain more luminous AGNs, while the X-ray AGN samples identify a wider range of AGN accretion rates including low specific accretion rate AGNs, where the host galaxy light dominates at IR wavelengths. The host galaxy populations of the IR and X-ray AGN samples have similar rest-frame colors and stellar masses; both selections identify AGNs in blue, star-forming and red, quiescent galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

TESTING MASS LOSS IN LARGE MAGELLANIC CLOUD CEPHEIDS USING INFRARED AND OPTICAL OBSERVATIONS. II. PREDICTIONS AND TESTS OF THE OGLE-III FUNDAMENTAL-MODE CEPHEIDS

In this paper, we test the hypothesis that Cepheids have infrared excesses due to mass loss. We fit a model using the mass-loss rate and the stellar radius as free parameters to optical observations from the OGLE-III survey and infrared observations from the Two Micron All Sky Survey and SAGE data sets. The sample of Cepheids has predicted minimum mass-loss rates ranging from 0 to 10{sup -8} M{sub sun} yr{sup -1}, where the rates depend on the chosen dust properties. We use the predicted radii to compute the period-radius relation for LMC Cepheids and to estimate the uncertainty caused by the presence of infrared excess for determining angular diameters with the infrared surface brightness technique. Finally, we calculate the linear and nonlinear period-luminosity (P-L) relations for the LMC Cepheids at VIJHK + IRAC wavelengths and find that the P-L relations are consistent with being nonlinear at infrared wavelengths contrary to previous results.

79 ASTRONOMY AND ASTROPHYSICS↗

Near Infrared Spectroscopy Calibration for Wood Chemistry: Which Chemometric Technique Is Best for Prediction and Interpretation?

This paper addresses the precision in factor loadings during partial least squares (PLS) and principal components regression (PCR) of wood chemistry content from near infrared reflectance (NIR) spectra. The precision of the loadings is considered important because these estimates are often utilized to interpret chemometric models or selection of meaningful wavenumbers. Standard laboratory chemistry methods were employed on a mixed genus/species hardwood sample set. PLS and PCR, before and after 1st derivative pretreatment, was utilized for model building and loadings investigation. As demonstrated by others, PLS was found to provide better predictive diagnostics. However, PCR exhibited a more precise estimate of loading peaks which makes PCR better for interpretation. Application of the 1st derivative appeared to assist in improving both PCR and PLS loading precision, but due to the small sample size, the two chemometric methods could not be compared statistically. This work is important because to date most research works have committed to PLS because it yields better predictive performance. But this research suggests there is a tradeoff between better prediction and model interpretation. Future work is needed to compare PLS and PCR for a suite of spectral pretreatment techniques.

09 BIOMASS FUELS↗

Remote sensing applied to numerical modelling

Progress and remaining difficulties in the construction of predictive mathematical models of large bodies of water as ecosystems are reviewed. Surface temperature is at present the only variable than can be measured accurately and reliably by remote sensing techniques, but satellite infrared data are of sufficient resolution for macro-scale modeling of oceans and large lakes, and airborne radiometers are useful in meso-scale analysis (of lakes, bays, and thermal plumes). Finite-element and finite-difference techniques applied to the solution of relevant coupled time-dependent nonlinear partial differential equations are compared, and the specific problem of the Biscayne Bay and environs ecosystem is tackled in a finite-differences treatment using the rigid-lid model and a rigid-line grid system.

Sengupta, S.↗

Advanced test techniques

Voltage margin tests, infrared scanning, and RF NOISE spectra measurements for digital test circuits

INFRARED SCANNER↗

The removal of atmospheric effects from remotely sensed near-infrared spectral data

A technique has been developed for removing atmospheric effects from high-resolution remotely sensed 0.7-2.5-micron spectral data. This calibration technique relies solely on the raw spectra data for calibration information. Results are presented for a set of reflectance spectra for rock samples obtained at a distance of about 0.5 km using an InSb spectrophotometer. The calibration technique uses the depths of water-vapor absorption bands in the remotely obtained spectral data to estimate the degree to which atmospheric attenuation has affected these data.

Blake, P. L.↗

Probing solar system objects at infrared wavelengths

The instruments, techniques, and analysis methods employed in IR observations of solar-system objects are discussed and illustrated with sample data. Particular attention is given to (1) high-resolution (Doppler-limited) spectra of H2O in Comet Halley and Comet Wilson (1986l), obtained with the NASA Kuiper Airborne Observatory in 1985-1986, and (2) scanning observations of Jovian thermal emission, obtained with the NASA IRTF in 1987 and subjected to detailed time-series analysis to investigate atmospheric motion. The data are presented in spectra, energy-level diagrams, maps, and graphs and briefly characterized.

Mumma, M. J.↗

The 55Fe X-ray Energy Response of Mercury Cadmium Telluride Near-Infrared Detector Arrays

A technique involving Fe-55 X-rays provides a straightforward method to measure the response of a detector. The detector's response can lead directly to a calculation of the conversion gain (e(-) ADU(-1) ), as well as aid detector design and performance studies. We calibrate the Fe-15 X-ray energy response and pair production energy of HgCdTe using 8 HST WFC3 1.7 micron flight grade detectors. The results show that each Ka X-ray generates 2273 +/- 137 electrons, which corresponds to a pair-production energy of 2.61 +/- 0.16 eV. The uncertainties are dominated by our knowledge of the conversion gain. In future studies, we plan to eliminate this uncertainty by directly measuring conversion gain at very low light levels.

Fox, Ori↗