Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inlet diffusers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Parametric evaluation of the aerodynamic performance of an annular combustor-diffuser system

This study experimentally determined the effects of dominant geometric and flow parameters on the aerodynamic performance of an annular combustor-diffuser system. For each parametric configuration, data were obtained at 13 different flow rates through the inner annulus, outer annulus, and combustor dome. The parametric effects investigated included the dump gap dimension, flow splits, prediffuser inlet velocity profile, and combustor channel height. During these measurements, the average prediffuser inlet Mach number was 0.305. The measured static pressure recovery coefficient and the total pressure loss coefficient in the prediffuser as well as the overall system are presented in this paper. The study found that the performance of the combustor-diffuser system improves with increasing dome flow rate or dump gap dimension.

Srinivasan, R.↗

Experimental Investigation of the Performance of a Mach-2.7 Two-dimensional Bifurcated Duct Inlet with 30 Percent Internal Contraction

An experimental study was conducted to determine the performance of a two-dimensional, mixed-compression bifurcated duct inlet system designed for a free-stream Mach number of 2.7. Thirty percent of the supersonic area contraction occurred internally. A movable ramp was used to vary the contraction ratio for off-design operation. Boundary layer bleed regions were located on the cowl, centerbody, and sidewall surfaces. There were also provisions for vortex generators on the cowl and centerbody of the subsonic diffuser. Data were obtained over the Mach number range of 2.0 to 2.8 and at angles of yaw from 0 deg. to the maximum value prior to inlet un-start. The test at Mach 2.8 was to obtain data for an over- speed condition. The Reynolds number varied from 2.5 to 2.3 million/ft for Mach numbers above 2.5. At Mach numbers of 2.5 and lower, the Reynolds number was set at 2.5 million/ft. Bleed patterns, vortex generator patterns, and ramp position were varied, and three inlet configurations were selected for more extensive study. Two of these configurations had self-starting capability. The self-starting configuration that was developed produced 89 percent total pressure recovery at the compressor face station with 6.8 percent total bleed. The compressor face distortion was about 16 percent. Vortex generators were extremely effective in re-distributing flow but were not as effective in reducing distortion. Excellent flow symmetry was achieved between the separated halves of the inlet, and twin-duct instability was not observed. The ramp tip shock was steeper than expected. This caused the cowl lip shock to be reflected from the ramp instead of being cancelled at the shoulder. However, peak recovery at the throat was still obtained with the ramp near the design position.

Wasserbauer, J. F.↗

Ambient ion focusing from a field-free region to a detector: enhanced signal for explosives and drug detection with mass spectrometry

This study demonstrates ion focusing at ambient pressure and increased ion signal by creating a voltage gradient from a field-free region to a detector, thereby improving the detection of chemicals, such as explosives and drugs. At ambient pressure, ion loss and resulting signal reduction pose challenges that limit detection sensitivity in analytical instruments. Techniques to increase sensitivity, such as atmospheric flow tube-mass spectrometry (AFT-MS), extend ion-molecule reaction times but result in significant overall ion loss due to diffusion. Ion manipulation techniques, though challenging at ambient pressure, can mitigate these losses by concentrating ions toward the detector inlet. Using SIMION, ion trajectories were modeled with a voltage gradient applied between a flow tube and a detector, revealing ion focusing at ambient pressure. Experimental verification with an atmospheric flow tube employed both mass spectrometry and Faraday plate detectors to measure ion beam profiles across varying flow rates, tube diameters, and voltage gradients. Application of a voltage gradient effectively directed ions to the axial center of the flow tube, narrowed ion beam width, and increased signal intensity by 5 to 10 times compared to conditions without a voltage gradient. This ion focusing approach shows promise for improving sensitivity in ambient-pressure instruments. This technique has the potential to enhance detection levels in security and forensic applications, with particular benefits for field-portable devices used at checkpoints to identify explosives and drugs.

ambient pressure↗

Experimental evaluation of two turning vane designs for high-speed corner of 0.1-scale model of NASA Lewis Research Center's proposed altitude wind tunnel

Two turning vane designs were experimentally evaluated for corner 1 (downstream of the test section) of a 0.1-scale model of the NASA Lewis Research Center's proposed Altitude Wind Tunnel (AWT). Vane A was a controlled-diffusion airfoil shape; vane B was a circular-arc airfoil shape. The vane designs were tested over corner inlet Mach numbers from 0.16 to 0.465. Several modifications in vane setting angle and vane spacing were also evaluated for vane A. The overall performance obtained from total pressure rakes indicated that vane B had a slightly lower loss coefficient than vane A. At Mach 0.35 (the design Mach number without the engine exhaust removal scoop), the loss coefficients were 0.150 and 0.178 for vanes B and A, respectively. Resetting the vane A angle by -5 deg. (vane A10) to turn the flow toward the outside corner reduced the loss coefficient to 0.119. The best configuration (vane A10) was also tested with a simulated engine exhaust removal scoop. The loss coefficient for that configuration was 0.164 at Mach 0.41 (the approximate design Mach number with the scoop).

Moore, R. D.↗

Carbon Fiber Reinforced/Silicon Carbide Turbine Blisk Testing in the SIMPLEX Turbopump

A program designed to implement a ceramic matrix composite integrally bladed disk (blisk) into rocket engine style turbomachinery has successfully completed testing. The Marshall Space Flight Center (MSFC) program, utilizing the MSFC turbomachinery design, analysis, and testing capabilities along with materials development capabilities from both Glenn Research Center (GRC) and MSFC, has tested two carbon fiber reinforced silicon carbide blisks in the Simplex Turbopump at MSFC's Test Stand 500. One blisk contained a polar woven fiber preform, while the second blisk tested utilized a quasi-isotropic preform. Vhile earlier papers have chronicled the program's design, material testing, and torque testing efforts, this paper focuses on the testing of the blisks in the Simplex turbopump. Emphasis will be placed on the actual condition of the blisks before and after the testing test program design methodology, and conclusions that can be drawn from the test data and blisk final conditions. The program performed three separate test series. The first series was needed to validate that the Simplex turbopump was correctly re-built following a major incident to the turbopump. The turbopump had two major differences from the original design. The most obvious difference was the sleeve required throughout the bore of the main housing. The second major difference was modifications to the pump diffuser to improve performance. Several areas were burnt during the incident and were either repaired by weld repair (pump inlet housing) or simply smoothed out (turbine nozzle discharge). The test series was designed to weed out any turbopump design and manufacturing flaws or fatigue issues prior to putting the C/SiC blisks into it. The second and third series were the C/SiC blisk test series. The primary goal of these series was to expose the blisks to as much fatigue causing dynamic stress as possible to examine the material's capability. Initially, the test plan was to put equal time on the two blisks, however, as the test series progressed, the funding allowed additional testing to occur. The additional test time was placed on the polar weave blisk. The total test time accrued on the polar blisk was 2550 seconds with 860 seconds near the turbopump design speed of 25,000 rpm. This testing included 6 tests / 775 seconds pumping liquid nitrogen and 7 tests / 1775 seconds pumping liquid oxygen. The drive gas for all of the tests was gaseous nitrogen due to the lack of hot gas source for the Simplex turbopump. The quasi-isotropic blisk was tested for XX total tests and XXXX seconds with X tests/XXXX seconds pumping liquid nitrogen and X tests/XXXX seconds pumping liquid \oxygen.During the test series, the blisks were inspected following each test. Inspections initially were viewed from the downstream side of the blisks only. Midway through the testing, a method of borescoping the leading edges of the blades was devised, and subsequently, both sides of the blades were inspected following each test. The leading and trailing edges of the polar blisk held up better than the quasi-isotropic blisk. This was a known possibility due to the varying fiber direction in the blades as the rectangular preform weave is cut in a circular pattern. The surprising fact about the testing was that there was no measurable performance loss due to the inaccuracies in the blade manufacturing in the C/SiC blisks, the surface roughness C/SiC of the blades, or the loss of the material in the polar blisk. A performance shift was seen in the quasi-isotropic blisk as portions of the leading and trailing edges were lost. After the testing was completed, detailed inspections of the blisks were performed. The largest surprise was the polar blisk had a obvious crack in a single blade that was located nearly midspan which was not detected in test. The crack ran completely through the blade circumferenciary and through the radial length of the blade. However, the crack does not appear to extend into the blisk hub. Although the cause of the crack is still under investigation, the material appears to be tolerant of this crack, and other hairline cracks discovered under higher magnification. This bodies well for eventual use of this material in actual flight turbopumps where monolithic fracture toughness issues limit its use.

Genge, Gary G.↗

A Low NO(x) Lean-Direct Injection, Multipoint Integrated Module Combuster Concept for Advanced Aircraft Gas Turbines

A low NO(x) emissions combustor has been demonstrated in flame-tube tests. A multipoint, lean-direct injection concept was used. Configurations were tested that had 25- and 36- fuel injectors in the size of a conventional single fuel injector. An integrated-module approach was used for the construction where chemically etched laminates, diffusion bonded together, combine the fuel injectors, air swirlers and fuel manifold into a single element. Test conditions were inlet temperatures up to 810 K, inlet pressures up to 2760 kPa, and flame temperatures up to 2100 K. A correlation was developed relating the NO(x) emissions with the inlet temperature, inlet pressure, fuel-air ratio and pressure drop. Assuming that 10 percent of the combustion air would be used for liner cooling and using a hypothetical engine cycle, the NO(x) emissions using the correlation from flame-tube tests were estimated to be less than 20 percent of the 1996 ICAO standard.

Tacina, Robert↗

Computational Study of the CC3 Impeller and Vaneless Diffuser Experiment

Centrifugal compressors are compatible with the low exit corrected flows found in the high pressure compressor of turboshaft engines and may play an increasing role in turbofan engines as engine overall pressure ratios increase. Centrifugal compressor stages are difficult to model accurately with RANS CFD solvers. A computational study of the CC3 centrifugal impeller in its vaneless diffuser configuration was undertaken as part of an effort to understand potential causes of RANS CFD mis-prediction in these types of geometries. Three steady, periodic cases of the impeller and diffuser were modeled using the TURBO Parallel Version 4 code: 1) a k-epsilon turbulence model computation on a 6.8 million point grid using wall functions, 2) a k-epsilon turbulence model computation on a 14 million point grid integrating to the wall, and 3) a k-omega turbulence model computation on the 14 million point grid integrating to the wall. It was found that all three cases compared favorably to data from inlet to impeller trailing edge, but the k-epsilon and k-omega computations had disparate results beyond the trailing edge and into the vaneless diffuser. A large region of reversed flow was observed in the k-epsilon computations which extended from 70% to 100% span at the exit rating plane, whereas the k-omega computation had reversed flow from 95% to 100% span. Compared to experimental data at near-peak-efficiency, the reversed flow region in the k-epsilon case resulted in an under-prediction in adiabatic efficiency of 8.3 points, whereas the k-omega case was 1.2 points lower in efficiency.

Kulkarni, Sameer↗

Computational Study of the CC3 Impeller and Vaneless Diffuser Experiment

Centrifugal compressors are compatible with the low exit corrected flows found in the high pressure compressor of turboshaft engines and may play an increasing role in turbofan engines as engine overall pressure ratios increase. Centrifugal compressor stages are difficult to model accurately with RANS CFD solvers. A computational study of the CC3 centrifugal impeller in its vaneless diffuser configuration was undertaken as part of an effort to understand potential causes of RANS CFD mis-prediction in these types of geometries. Three steady, periodic cases of the impeller and diffuser were modeled using the TURBO Parallel Version 4 code: (1) a k-ε turbulence model computation on a 6.8 million point grid using wall functions, (2) a k-ε turbulence model computation on a 14 million point grid integrating to the wall, and (3) a k-ω turbulence model computation on the 14 million point grid integrating to the wall. It was found that all three cases compared favorably to data from inlet to impeller trailing edge, but the k-ε and k-ω computations had disparate results beyond the trailing edge and into the vaneless diffuser. A large region of reversed flow was observed in the k-ε computations which extended from 70 to 100 percent span at the exit rating plane, whereas the k-ω computation had reversed flow from 95 to 100 percent span. Compared to experimental data at near-peak-efficiency, the reversed flow region in the k-ε case resulted in an underprediction in adiabatic efficiency of 8.3 points, whereas the k-ω case was 1.2 points lower in efficiency.

Kulkarni, Sameer↗

Free-flight Performance of a Rocket-boosted, Air-launched 16-inch-diameter Ram-jet Engine at Mach Numbers up to 2.20

The investigation of air-launched ram-jet engines has been extended to include a study of models with a nominal design free-stream Mach number of 2.40. These models require auxiliary thrust in order to attain a flight speed at which the ram jet becomes self-accelerating. A rocket-boosting technique for providing this auxiliary thrust is described and time histories of two rocket-boosted ram-jet flights are presented. In one flight, the model attained a maximum Mach number of 2.20 before a fuel system failure resulted in the destruction of the engine. Performance data for this model are presented in terms of thrust and drag coefficients, diffuser pressure recovery, mass-flow ratio, combustion efficiency, specific fuel consumption, and over-all engine efficiency.

AIR INLETS - NOSE, ANNULAR↗

Hypersonic Magneto-Fluid-Dynamic Compression in Cylindrical Inlet

Hypersonic magneto-fluid-dynamic interaction has been successfully performed as a virtual leading-edge strake and a virtual cowl of a cylindrical inlet. In a side-by-side experimental and computational study, the magnitude of the induced compression was found to be depended on configuration and electrode placement. To better understand the interacting phenomenon the present investigation is focused on a direct current discharge at the leading edge of a cylindrical inlet for which validating experimental data is available. The present computational result is obtained by solving the magneto-fluid-dynamics equations at the low magnetic Reynolds number limit and using a nonequilibrium weakly ionized gas model based on the drift-diffusion theory. The numerical simulation provides a detailed description of the intriguing physics. After validation with experimental measurements, the computed results further quantify the effectiveness of a magnet-fluid-dynamic compression for a hypersonic cylindrical inlet. At a minuscule power input to a direct current surface discharge of 8.14 watts per square centimeter of electrode area produces an additional compression of 6.7 percent for a constant cross-section cylindrical inlet.

Shang, Joseph S.↗

Study of aerodynamic noise in low supersonic operation of an axial flow compressor

A study of compressor noise is presented, based upon supersonic, part-speed operation of a high hub/tip ratio compressor designed for spanwise uniformity of aerodynamic conditions, having straight cylindrical inlet and exit passages for acoustic simplicity. Acoustic spectra taken in the acoustically-treated inlet plenum, are presented for five operating points at each of two speeds, corresponding to relative rotor tip Mach numbers of about 1.01 and 1.12 (60 and 67 percent design speed). These spectra are analyzed for low and high frequency broadband noise, blade passage frequency noise, combination tone noise and "haystack' noise (a very broad peak somewhat below blade passage frequency, which is occasionally observed in engines and fan test rigs). These types of noise are related to diffusion factor, total pressure ratio, and relative rotor tip Mach number. Auxiliary measurements of fluctuating wall static pressures and schlieren photographs of upstream shocks in the inlet are also presented and related to the acoustic and performance data.

Arnoldi, R. A.↗

The choking pressure ratio of a critical flow venturi

The critical flow venturi has many important applications in the measurement and control of gas flow. In many of these applications, it is desirable to minimize the pressure loss required to maintain critical flow conditions. The performance of the venturi may be characterized by the ratio of outlet static pressure to inlet total pressure just sufficiently small to produce critical flow. This ratio is called choking pressure ratio. The optimization of diffusers for critical flow venturis is discussed and suggestions for designs practice are presented. Test results are given for six different diffuser configurations, and a comparison is made with data on 11 configurations from other investigators. It is shown that, for the small divergence angles considered, a simply defined diffuser effectiveness parameter is approximately independent of flow conditions and may be used to predict choking pressure ratio.

Hillbrath, H. S.↗

Preliminary aerodynamic calibration of the spinning mode synthesizer flow duct facility

Results of the initial aerodynamic calibration of the spinning mode synthesizer flow duct facility in the Aircraft Noise Reduction Laboratory are presented. The system is shown to be operable over an inlet Mach number range of zero to 0.6. Mach number profiles are presented at several axial stations along the duct. Diffuser performance is reviewed. Spatial and temporal variations are discussed.

Silcox, R. J.↗

Dynamics and control of hypersonic aeropropulsive/aeroelastic vehicles

The guidance and control of hypersonic vehicles is examined by studying the airframe/engine/structural-dynamic interactions of a generic vehicle with scramjet propulsion. The pitch-attitude dynamics are described for the vehicle configuration that can sustain hypersonic flight at near-orbital altitudes. These aerospacecraft have strong airframe/engine/elastic coupling in attitude dynamics and engine responses with static instability with respect to pitch. An integrated airframe-engine control system is presented for the control of the system's strong aeropropulsive/aeroelastic coupling. The control methodology utilizes feedback of measured/synthesized values of angle of attack, blended pitch rate, thrust, and combustor-inlet pressure. The multiinput/multioutput engine controller requires high-bandwidth actuation of the fuel-flow control and the effective diffuser ratio. The proposed control laws do not provide optimized performance in terms of pitch response suggesting that additional control crossfeeds and filtering is needed.

Schmidt, David K.↗

Hydrogen no-vent fill testing in a 1.2 cubic foot (34 liter) tank

Experimental results of no-vent fill testing with liquid hydrogen in a 1.2 cubic foot (34 liter) stainless steel tank are presented. More than 40 tests were performed with various liquid inlet temperatures, inlet flowrates, initial tank wall temperatures, and liquid injection techniques. Fill levels equal to or exceeding 90 percent by volume were achieved in 40 percent of the tests with the tank pressure limited to a maximum of 30 psia. Three liquid injection techniques were employed; top spray, upward pipe discharge, and bottom diffuser. Effects of each of the varied parameters on the tank pressure history and final fill level are evaluated. The final fill level is found to be indirectly proportional to the initial wall and inlet liquid temperatures and directly proportional to the inlet liquid flowrate. Furthermore, the top spray is the most efficient no-vent fill method of the three configurations examined. The success of this injection method is primarily due to condensation of the ullage vapor onto the incoming liquid droplets. Ullage condensation counteracts the tank pressure rise resulting from energy exchange between the fluid and the warmer tank walls, and ullage compression. Upward pipe discharge from the tank bottom is the next most efficient method. Fluid circulation induced by this fill configuration tends to diminish thermal stratification in the bulk liquid, thus enhancing condensation at the liquid gas interface.

Moran, Matthew E.↗

Three-dimensional compressible turbulent computations for a diffusing S-duct

The purpose of the present study was to evaluate the capability of the computational fluid dynamics computer program PARC3D to model flow in a typical diffusing subsonic S-duct, with strong secondary flows. This evaluation is needed to provide confidence in the analysis of aircraft inlets, which have similar geometries. The performance predictions include total pressure profiles, static pressures, velocity profiles, boundary layer data, and skin friction data. Flow in the S-duct is subsonic, and the boundary layers are assumed to be turbulent. The results for both H and O grid solutions, are compared with existing test data.

Smith, C. F.↗

Wind tunnel investigation of three axisymmetric cowls of different lengths at Mach numbers from 0.60 to 0.92

Pressure distributions on three inlets having different cowl lengths were obtained in the Langley 16-Foot Transonic Tunnel. The cowl diameter ratio (highlight diameter to maximum diameter) was 0.85 and the cowl length ratios (cowl length to maximum diameter) were 0.337, 0.439, and 0.547. The cowls had identical nondimensionalized (with respect to cowl length) external geometry and identical internal geometry. The internal contraction ratio (highlight area to throat area) was 1.250. The inlets had longitudinal rows of static pressure orifices on the top and bottom (external) surfaces and on the contraction (internal) and diffuser surfaces. The afterbody was cylindrical in shape, and its diameter was equal to the maximum diameter of the cowl. Depending on the cowl configuration and free-stream Mach number, the mass-flow ratio varied between 0.27 and 0.87 during the tests. Angle of attack varied from 0 to 4.1 deg at selected Mach numbers and mass-flow ratios, and the Reynolds number varied with the Mach number from 3.2x10(exp 6) to 4.2x10(exp 6) per foot.

Re, Richard J.↗

Hydrogen no-vent fill testing in a 34 liter (1.2 cubic foot) tank

Experimental results of no-vent fill testing with liquid hydrogen in a 34 liter stainless steel tank are presented. More than 40 tests were performed with various liquid inlet temperatures, inlet flowrates, initial tank wall temperatures, and liquid injection techniques. Maximum pressure within the receiver tank was limited to 0.207 MPa (30 psia), and fill levels equal to or exceeding 90 percent by volume were achieved in 40 percent of the tests. Three liquid injection techniques were employed; top spray, upward pipe discharge, and bottom diffuser. Effects of each of the various parameters on the tank pressure history and final fill level are evaluated. The final fill level is found to be indirectly proportional to the initial wall and inlet liquid temperatures and directly proportional to the inlet liquid flowrate. Furthermore, the top spray is the most efficient no-vent fill method of the three configurations examined. The success of this injection method is primarily due to condensation of the ullage vapor onto the incoming liquid droplets. Ullage condensation counteracts the tank pressure rise resulting from energy exchange between the fluid and the warmer tank walls and from ullage compression.

Moran, Matthew E.↗