Search NASA⌕ Search

SEARCH · Search NASA

Results for “Insertion device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Ozone Generator Aluminum Electrode Soldering

The creation of an entirely soldered ozone electrode component is proposed and implemented for the first time by the authors. Electrode construction with a ribbed plate insert within it is the most perfect heat exchange device from the point of view of effective heat exchange and uniform distribution of liquid flow through its section. Stages are considered for electrode preparation for soldering and a standard heating cycle is proposed for soldering and electrode with eutectic silumin. It is shown that as a result of the soldering thermal cycle metal structure becomes coarse-grained and favorable for subsequent electrochemical formation of a nanostructured anodic oxide coating 50–60 μm thick.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Positioning effects on quantum dot solar cells grown by molecular beam epitaxy

We report current-voltage and spectral response characteristics of high density InAs/GaAs quantum dot (QD) solar cells with different positions where dots are located. The short circuit current density (J{sub sc}), open circuit voltage (V{sub oc}), and external quantum efficiency of these cells under air mass 1.5 are presented and compared with a GaAs reference cell. An extended photoresponse in contrast to the GaAs reference cell was confirmed for all these cells. The effect of inserting QD layers into emitter and base region on device performance is shown. The J{sub sc} is reduced, while the V{sub oc} is maintained. The cell with QDs located toward the base side shows better performance, confirmed by both current-voltage and spectral response measurements.

36 MATERIALS SCIENCE↗

Packaging of microwave integrated circuits operating beyond 100 GHz

Several methods of packaging high speed (75-330 GHz) InP HEMT MMIC devices are discussed. Coplanar wirebonding is presented with measured insertion loss of less than 0.5dB and return loss better than -17 dB from DC to 110 GHz. A motherboard/daughterboard packaging scheme is presented which supports minimum loss chains of MMICs using this coplanar wirebonding method. Split waveguide block packaging approaches are presented in G-band (140-220 GHz) with two types of MMIC-waveguide transitions: E-plane probe andantipodal finline.

HEMT MMICS power amplifiers↗

Control rod position indicator

A rod position indication system includes a drive rod operably coupled to a control rod that is configured to be both withdrawn from and inserted into a reactor core. A number of sensing devices are arranged along a path of the drive rod, and an end of the drive rod passes by or through one or more of the sensing devices in response to movement of the control rod relative to the reactor core. The sensing devices are arranged into a plurality of groups, and each group includes two or more of the sensing devices electrically coupled together. The rod position indication system further includes a control rod monitoring device electrically coupled to each group of sensing devices by a routing wire.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Tuning the critical Li intercalation concentrations for MoX 2 (X = S, Se, or Te) bilayer phase transitions

Transition metal dichalcogenides (TMDs), such as MoS 2 , are known to undergo a structural phase transformation as well as a change in the electronic conductivity upon Li intercalation. These properties make them candidates for charge-tunable ion-insertion materials that could be used in electro-chemical devices. In this work we study the phase stability and electronic structure of H and T’ Li-intercalated MoX 2 bilayers with X=S, Se, or Te. Here, using first-principles calculations in combination with classical and machine learning modeling approaches, we find that the H phase is more stable at low Li concentration for all X, and the critical Li concentration at which the T’→H transition occurs decreases with increasing mass of X. Furthermore the relative free energy of the two phases becomes less sensitive to Li insertion with increasing atomic mass of the chalcogen atom X. While the electronic conductivity increases with increasing ion concentration at low concentrations, we do not observe a (positive) conductivity jump at the phase transition from H to T’.

36 MATERIALS SCIENCE↗

Power transient analyses of experimental in-reflector devices during safety shutdown in Jules Horowitz Reactor (JHR)

The Jules Horowitz Reactor (JHR) is designed to be a 100 MW material testing reactor (MTR) and it is expected to become the reference facility in the framework of European nuclear research activity. As the core neutron spectrum is quite fast, several experimental devices concerning fuel studies have been conceived to be placed in the reflector in order to exploit a proper thermal neutron flux irradiation. Since the core power is relatively high, the neutronic coupling between the reactor core and the reflector devices has to be taken into account for different rod insertions. In fact the thermal power produced within the fuel samples is considerable. Heat removal during shutdown is a main topic in nuclear safety and it is worth to analyse thermal power transients in fuel samples as well. Here a thermal hydraulic model for JHR core is proposed aiming at a simple and representative description as far as reactivity feedbacks are concerned. Then it is coupled with a neutronic pointwise kinetics analysis by means of the DULCINEE code to compute core power transient calculations. Moreover, some reflector-core coupling evaluations are performed through Monte Carlo method using the TRIPOLI 4.7 code. The JHR equilibrium cycle is considered with respect to four fuel compositions namely Beginning of Cycle (BOC), Xenon Saturation Point (XSP), Middle of Cycle (MOC) and End of Cycle (EOC). Then thermal power transients in the experimental reflector devices are evaluated during safety shutdowns and they are verified for all these cycle steps. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Femtosecond laser fabrication of nanograting-based distributed fiber sensors for extreme environmental applications

Abstract The femtosecond laser has emerged as a powerful tool for micro- and nanoscale device fabrication. Through nonlinear ionization processes, nanometer-sized material modifications can be inscribed in transparent materials for device fabrication. This paper describes femtosecond precision inscription of nanograting in silica fiber cores to form both distributed and point fiber sensors for sensing applications in extreme environmental conditions. Through the use of scanning electron microscope imaging and laser processing optimization, high-temperature stable, Type II femtosecond laser modifications were continuously inscribed, point by point, with only an insertion loss at 1 dB m −1 or 0.001 dB per point sensor device. High-temperature performance of fiber sensors was tested at 1000 °C, which showed a temperature fluctuation of ±5.5 °C over 5 days. The low laser-induced insertion loss in optical fibers enabled the fabrication of a 1.4 m, radiation-resilient distributed fiber sensor. The in-pile testing of the distributed fiber sensor further showed that fiber sensors can execute stable and distributed temperature measurements in extreme radiation environments. Overall, this paper demonstrates that femtosecond-laser-fabricated fiber sensors are suitable measurement devices for applications in extreme environments.

Wang, Mohan (ORCID:0000000166784993)↗

Atomic-Layer-Deposited Transparent Electrodes for Silicon Heterojunction Solar Cells

We examine damage-free transparent-electrode deposition to fabricate high-efficiency amorphous silicon/crystalline silicon heterojunction solar cells. Such solar cells usually feature sputtered transparent electrodes, the deposition of which may damage the layers underneath. Using atomic layer deposition, we insert thin protective films between the amorphous silicon layers and sputtered contacts and investigate their effect on device operation. We find that a 20-nm-thick protective layer suffices to preserve, unchanged, the amorphous silicon layers beneath. Insertion of such protective atomic-layer-deposited layers yields slightly higher internal voltages at low carrier injection levels. However, we identify the presence of a silicon oxide layer, formed during processing, between the amorphous silicon and the atomic-layer-deposited transparent electrode that acts as a barrier, impeding hole and electron collection.

14 SOLAR ENERGY↗

Development and validation of a new guidance device for lateral approach stereotactic breast biopsy

Stereotactic breast biopsy (SBB) is the gold standard for minimally invasive breast cancer diagnosis. Current systems rely on one of two methods for needle insertion: A vertical approach (perpendicular to the breast compression plate) or a lateral approach (parallel to the compression plate). While the vertical approach is more frequently used, it is not feasible in patients with thin breasts (<3 cm thick after compression) or with superficial lesions. Further, existing SBB guidance hardware provides at most one degree of rotational freedom in the needle trajectory, and as such requires a separate skin incision for each biopsy target. The authors present a new design of lateral guidance device for SBB, which addresses the limitations of the vertical approach and provides improvements over the existing lateral guidance hardware. Specifically, the new device provides (1) an adjustable rigid needle support to minimize needle deflection within the breast and (2) an additional degree of rotational freedom in the needle trajectory, allowing the radiologist to sample multiple targets through a single skin incision. This device was compared to a commercial lateral guidance device in a series of phantom experiments. Needle placement error using each device was measured in agar phantoms for needle insertions at lateral depths of 2 and 5 cm. The biopsy success rate for each device was then estimated by performing biopsy procedures in commercial SBB phantoms. SBB performed with the new lateral guidance device provided reduced needle placement error relative to the commercial lateral guidance device (0.89{+-}0.22 vs 1.75{+-}0.35 mm for targets at 2 cm depth; 1.94{+-}0.20 vs 3.21{+-}0.31 mm for targets at 5 cm depth). The new lateral guidance device also provided improved biopsy accuracy in SBB procedures compared to the commercial lateral guidance device (100% vs 58% success rate). Finally, experiments were performed to demonstrate that the new device can accurately sample lesions within thin breast phantoms and multiple lesions through a single incision point. This device can be incorporated directly into the clinical SBB procedural workflow, with no additional electrical hardware, software, postprocessing, or image analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis

PurposeTo evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy.Materials and MethodsIn this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if the absolute difference in their propensity scores was ≤equal to 0.02.ResultsBefore matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p < 0.0001) rates compared to the control group. Sub-analysis including only faculty who had >30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates.ConclusionsThe self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effect of a Ta oxygen scavenger layer on HfO 2 -based resistive switching behavior: Thermodynamic stability, electronic structure, and low-bias transport

Reversible resistive switching between high-resistance and low-resistance states in metal-oxide-metal heterostructures makes them very interesting for applications in random access memories. While recent experimental work has shown that inserting a metallic "oxygen scavenger layer'' between the positive electrode and oxide improves device performance, the fundamental understanding of how the scavenger layer modifies the heterostructure properties is lacking. We use density functional theory to calculate thermodynamic properties and conductance of TiN/HfO 2 /TiN heterostructures with and without a Ta scavenger layer. First, we show that Ta insertion lowers the formation energy of low-resistance states. Second, while the Ta scavenger layer reduces the Schottky barrier height in the high-resistance state by modifying the interface charge at the oxide-electrode interface, the heterostructure maintains a high resistance ratio between high-and low-resistance states. Lastly, we show that the low-bias conductance of device on-states becomes much less sensitive to the spatial distribution of oxygen removed from the HfO 2 in the presence of the Ta layer. By providing a fundamental understanding of the observed improvements with scavenger layers, we open a path to engineer interfaces with oxygen scavenger layers to control and enhance device performance. In turn, this may enable the realization of a non-volatile low-power memory technology with concomitant reduction in energy consumption by consumer electronics and offering significant benefits to society.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetotransport properties of spin-valve structures with Mg spacer layers

A theoretical prediction by Wang et al. [Phys. Rev. B 82, 054405 (2010)] suggests the preferential transmission of majority-spin states with Δ{sub 1} symmetry across a magnesium interlayer in Fe/Mg/MgO/Fe based magnetic tunnel junctions. Here, we report experiments to probe this question in CoFe/Mg/CoFe structures. We find that the strength of the interlayer coupling decays exponentially with increasing the spacer thickness, however, a non-monotonic variation of the magnetoresistance as a function of the Mg layer is observed. These data may help revisit the role of the insertion of a Mg interface layer in MgO-based devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electrochemical-Mechanical Coupling Strongly Affects the Performance of Nanopore, Thin-Film, and Solid-State Batteries

Here, the present study focuses on the electrochemical-mechanical (ECM) coupling effects of a thin-film, solid-state battery with only stiff, ceramic materials, in contrast to prior investigations that focus on individual active material particles or aggregations of particles. We model the impacts of ECM couplings including stress-transport and stress-equilibrium potential on the full-cell performance and potential mechanical failure modes of a thin-film battery conformally deposited in a nanopore scaffold, which is an experimentally achievable device. Model results indicate electrode volume changes due to lithium insertion or removal, along with mechanical boundary conditions, result in stress gradients that alter the lithium-ion flux, reduce lithium concentration gradients, and improve cell rate capability. However, the high stress levels in the cell can also lead to mechanics-related failure such as the separation of cell layers. For the parameter set in this work, stress-transport coupling has a much greater influence on rate capability than stress-potential coupling. Optimization of thin-film batteries to harness the benefits of ECM coupling effects requires leveraging geometric design and material selection. The current work underscores the need for further theoretical and experimental investigation into ECM coupling effects in thin-film batteries to enhance their understanding and design optimization.

25 ENERGY STORAGE↗

Tuning the critical Li intercalation concentrations for MoX 2 bilayer phase transitions using classical and machine learning approaches

Transition metal dichalcogenides (TMDs) such as MoX 2 are known to undergo a structural phase transformation as well as a change in the electronic conductivity upon Li intercalation. These properties make them candidates for charge tunable ion-insertion materials that could be used in electro-chemical devices for neuromorphic computing applications. In this work we study the phase stability and electronic structure of Li-intercalated bilayer MoX 2 with X=S, Se or Te. Using first-principles calculations in combination with classical and machine learning modeling approaches we find that the energy needed to stabilize the conductive phase decreases with increasing atomic mass of the chalcogen atom X. A similar decreasing trend is found in the threshold Li concentration where the structural phase transition takes place. While the electronic conductivity increases with increasing ion concentration at low concentrations, we do not observe a conductivity jump at the phase transition point.

36 MATERIALS SCIENCE↗

Turbulent Reynolds analogy factors of stacked large-eddy breakup devices

Direct measurements are made of turbulent Reynolds analogy factors, referenced to a flat plate, for turbulent boundary layer flows altered by stacked arrays of large eddy breakup devices (LEBUs). These are of interest as drag reducers when inserted into a boundary layer transverse to the flow. The data thus obtained furnish evidence that heat transfer, skin friction drag, and LEBU performance factors in low Reynolds number flows are sensitive to flow history. Attention is given to the apparatus and measurement procedures used.

Lindemann, A. M.↗

Atomistic Conversion Reaction Mechanism of WO 3 in Secondary Ion Batteries of Li, Na, and Ca

Abstract Intercalation and conversion are two fundamental chemical processes for battery materials in response to ion insertion. The interplay between these two chemical processes has never been directly seen and understood at atomic scale. Here, using in situ HRTEM, we captured the atomistic conversion reaction processes during Li, Na, Ca insertion into a WO 3 single crystal model electrode. An intercalation step prior to conversion is explicitly revealed at atomic scale for the first time for Li, Na, Ca. Nanoscale diffraction and ab initio molecular dynamic simulations revealed that after intercalation, the inserted ion–oxygen bond formation destabilizes the transition‐metal framework which gradually shrinks, distorts and finally collapses to an amorphous W and M x O (M=Li, Na, Ca) composite structure. This study provides a full atomistic picture of the transition from intercalation to conversion, which is of essential importance for both secondary ion batteries and electrochromic devices.

He, Yang↗

Retrospective comparison of outcomes and associated complications between large bore radiologically inserted gastrostomy tube types

Purpose: Multiple approaches to radiologically inserted gastrostomy (RIG) exist. The goal of this study was to compare 30-day outcomes and associated complications between large bore balloon-retained (BR), loop-retained (LR), and pull-type (PT) RIG devices. Methods: Data on 1477 patients who underwent RIG between January 1, 2005 and December 31, 2016 were collected retrospectively using a dedicated interventional radiology database and electronic medical record. Statistical analysis was performed to compare complication rates between BR, LR, and PT devices. Results: Ninety-eight percent (1477/1507) of the procedures were successfully performed. A total of 752 BR, 323 LR, and 402 PT gastrostomy tubes were placed. The overall complication rate for BR catheters was 5.7% (25 major [3.3%] and 18 minor [2.4%]). The overall complication rate for PT catheters was 3.7% (8 major [2.0%] and 7 minor [1.7%]). The overall complication rate for LR catheters was 1.6% (4 major [1.4%] and 1 minor [0.8%]). Compared to BR catheters, LR catheters had significantly fewer total complications (P = 0.01) but not minor complications (P = 0.052). There were no significant differences in the number of complications between LR and PT catheters or between BR and PT catheters. Conclusions: Use of BR, LR, and PT devices for RIG is safe with a low incidence of complications. Compared to BR catheters, primary insertion of a LR gastrostomy was associated with significantly fewer overall complications within the first 30 days. Therefore, for initial tube placement, large bore LR catheters may be preferred over BR devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thin Film Ba(x)Sr(1-x)TiO3 Ku- and K-Band Phase Shifters Grown on MgO Substrates

We report measurements of gold circuits fabricated on four Ba(x)Sr(1-x)TiO3 films doped with 1% Mn grown on MgO substrates by laser ablation. Low frequency measurements of epsilon(sub r) and tan(delta) on interdigital capacitors are compared with high frequency measurements of phase shift and insertion loss on coupled microstrip phase shifters done on the same films. The variation in temperature of both high and low frequency device parameters is compared. Annealed and unannealed films are compared. Room temperature figures of merit of phase shift per insertion loss of up to 58.4 C/dB at 18 GHz and 400 V dc bias were measured.

VanKeuls, F. W.↗