Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOADS - DISKS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Restoration Strategy for Active Distribution Systems Considering Endogenous Uncertainty in Cold Load Pickup

Cold load pickup (CLPU) phenomenon is identified as the persistent power inrush upon a sudden load pickup after an outage. Under the active distribution system (ADS) paradigm, where distributed energy resources (DERs) are extensively installed, the decreased outage duration can induce a strong interdependence between CLPU pattern and load pickup decisions. In this paper, we propose a novel modelling technique to tractably capture the decision-dependent uncertainty (DDU) inherent in the CLPU process. Subsequently, a two-stage stochastic decision-dependent service restoration (SDDSR) model is constructed, where first stage searches for the optimal switching sequences to decide step-wise network topology, and the second stage optimizes the detailed generation schedule of DERs as well as the energization of switchable loads. Further, to tackle the computational burdens introduced by mixed-integer recourse, the progressive hedging algorithm (PHA) is utilized to decompose the original model into scenario-wise subproblems that can be solved in parallel. The numerical test on modified IEEE 123-node test feeders has verified the efficiency of our proposed SDDSR model and provided fresh insights into the monetary and secure values of DDU quantification.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bucket Loading Trajectory Optimization for the Automated Wheel Loader

The bucket motion of a wheel loader during the loading process is investigated in this study. The optimal bucket loading trajectory can be obtained by solving an optimal control problem with the performance criteria of the fill factor , fuel efficiency and operation cycle time . A control-oriented model for the bucket loading operation is developed. Based on the control-oriented model, the bucket loading process is formulated as an optimal control problem with physical constraints. An open-source optimization solver, OpenOCL, is used to solve this problem. The simulation results show that the proposed method is effective in generating the optimal trajectory with significantly increased energy efficiency and productivity. Furthermore, this optimal trajectory can be employed as a reference for an automated wheel loader or as a driver advisory for a human operated wheel loader.

42 ENGINEERING↗

Building Load Control Using Distributionally Robust Chance-Constrained Programs with Right-Hand Side Uncertainty and the Risk-Adjustable Variants

Aggregation of heating, ventilation, and air conditioning (HVAC) loads can provide reserves to absorb volatile renewable energy, especially solar photo-voltaic (PV) generation. In this paper, we decide HVAC control schedules under uncertain PV generation, using a distributionally robust chance-constrained (DRCC) building load control model under two typical ambiguity sets: the moment-based and Wasserstein ambiguity sets. We derive mixed integer linear programming (MILP) reformulations for DRCC problems under both sets. Especially, for the Wasserstein ambiguity set, we use the right-hand side (RHS) uncertainty to derive a more compact MILP reformulation than the commonly known MILP reformulations with big-M constants. All the results also apply to general individual chance constraints with RHS uncertainty. Furthermore, we propose an adjustable chance-constrained variant to achieve tradeoff between the operational risk and costs. We derive MILP reformulations under the Wasserstein ambiguity set and second-order conic programming (SOCP) reformulations under the moment-based set. Using real-world data, we conduct computational studies to demonstrate the efficiency of the solution approaches and the effectiveness of the solutions. Summary of Contribution: The problem studied in this paper is motivated by a building load control problem that uses the aggregation of heating, ventilation, and air conditioning (HVAC) loads as flexible reserves to absorb uncertain solar photovoltaic (PV) generation. The problem is formulated as distributionally robust chance-constrained (DRCC) programs with right-hand side (RHS) uncertainty. In addition, we propose a risk-adjustable variant of the DRCC programs, where the risk level, instead of being predetermined, is treated as a decision variable. The paper aims to provide tractable reformulations and solution algorithms for both the (general) DRCC and the (general) adjustable DRCC models with RHS uncertainty.

97 MATHEMATICS AND COMPUTING↗

Implementation of Substructure Flexibility and Member-Level Load Capabilities for Floating Offshore Wind Turbines in OpenFAST

OpenFAST is an open-source, physics-based engineering tool applicable to the load analysis of land-based and offshore wind turbines, including floating offshore wind turbines. The substructure for a floating wind turbine has historically been modeled in OpenFAST as a rigid body with hydrodynamic loads lumped at a point, which enabled the tool to predict the global response of the floating substructure but not the structural loads within its individual members. This limitation is an impediment to designing floating substructures - especially newer designs that are more streamlined, flexible, and cost-effective. This paper presents the development of new functionality in OpenFAST to model floating substructure flexibility and member-level loads, as well as the concepts and mathematical background needed to understand and apply it correctly.

17 WIND ENERGY↗

Up-Tower Investigation of Main Bearing Cage Slip and Loads

This paper described the operational conditions of an SRB in the main bearing position of a three-point mount wind turbine drivetrain. A commercial wind turbine was instrumented to measure load characteristics on the outer ring of the bearing, which were used to examine the roller load characteristics qualitatively and the cage slip quantitatively in a range of operational states. Further, a simple analytic model estimated the bearing loads and was used as input conditions to a three-dimensional finite element model. The finite element roller load results were compared to the measurements and contact stresses were also described.

17 WIND ENERGY↗

ComStock Measure Documentation: Ideal Thermal Air Loads

This study provides hypothetical thermal heating and cooling loads for ComStock models representing the U.S. commercial building stock. This measure scenario removes all HVAC models from the baseline ComStock building model and instead uses "ideal air" to meet loads. "Ideal air" can be thought of as an HVAC unit that mixes air at the zone exhaust condition with the specified amount of outdoor air, and then adds or removes heat and moisture at 100% efficiency to produce a supply air stream at the specified conditions. The resulting ideal thermal loads are represented under the "district" fuel type for both heating and cooling and can be found in both annual and timeseries results in the ComStock public dataset. This measure scenario does not represent any real technology or improvement, but rather, serves as a resource for thermal heating and cooling loads for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Large Load Management and Grid Planning

This presentation will cover these topics, followed by a discussion and Q&A: Grid impacts of load growth of the current bulk power system, a review of recent trends and events related to large load integration, what might these new large loads look like, what are options for reducing costs and timelines of integration, and working toward a framework for identifying hot spots for efficiently interconnecting large loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Load Forecasting

This presentation presents information about electric utility load forecasting in the U.S. It provides an overview of load forecasting and describes the current state of the industry. Current load forecasting challenges, opportunities, and interests are presented, including feedback from a 2024 workshop on Integrated Distribution System Planning. The presentation also describes a variety of NREL tools and capabilities that support utility load forecasting efforts. This was presented as part of NREL's Utility Planning Resources for Energy Transition Webinar Series.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ComStock Measure Documentation: Lighting Control for Load Shedding

This report describes the modeling methodology for a single end-use savings shape measure - lighting control for load shedding - and briefly introduces key results. The lighting control for load shedding measure applies lighting dimming control to reduce the lighting load during the building's electricity peak window every weekday. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the predicted peak window, and then adjusts the lighting dimming level by a percentage reduction from the original schedules during the peak window to reduce the peak demand. The measure is applicable to (large, medium and small) offices, warehouses, and primary and secondary schools, which correspond to approximately 68% of the stock floor area of commercial buildings in ComStock analysis. The measure demonstrates 2%-7% daily peak demand reduction performance for applicable buildings, and 0.43% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying the Effect of Economic Development Zones on Electrical Load Growth in Kentucky [Slides]

The Kentucky Energy and Environment Cabinet has recently undertaken a comprehensive effort to map and catalog potential economic development sites across the state. The purpose of this technical assistance is to quantify the potential impact of developing designated sites on Kentucky's electricity load growth, providing insights at both state and county level considering the next 10 years. This analysis should explicitly incorporate and address key project uncertainties by developing various load growth scenarios that account for development scale, site specificity, and sector variability. The need for a site-specific analysis comes from the understanding that conventional econometric (top-down) load forecasting models cannot sufficiently isolate or predict the discrete load increases resulting from the development of these unique and targeted economic sites.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Digital Assurance for Grid Reliability in the Era of Large Load Growth

The rapid expansion of large electric loads is reshaping the operational and regulatory landscape of the U.S. electric grid. These facilities are reaching new scales of expansion, now exceeding a gigawatt per site, and their highly sensitive, digitally driven behaviors introduce new reliability risks. Recent grid events, including large load losses following routine transmission disturbances, highlight the consequences of limited ride-through capability, inconsistent protection settings, inadequate modeling, and lack of behind-the-meter visibility. Parallels to earlier integration challenges of new grid technologies suggest that the grid’s existing processes, standards, and interconnection frameworks are no longer adequate for emerging large loads. This brief synthesizes lessons from the evolution of inverter-based resource regulation and applies them to large-load integration. It identifies critical gaps in modeling accuracy, interconnection processes, performance standards, and compliance mechanisms. Technical recommendations emphasize advanced monitoring, improved modeling, coordinated communication protocols, modernized substations, and structured behind-the-meter control schemes. Collectively, these measures provide a roadmap to maintain bulk power system reliability while enabling the continued growth of large, electrified digital infrastructure.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

The Role of the U.S. Electric Distribution System in Serving Data Center and Other Large Loads

The rapid expansion of data centers in the United States is reshaping how the electric distribution system must plan for and accommodate large load interconnections. This report evaluates the role of the distribution grid in serving these loads, from small edge facilities to hyperscale campuses. Using national datasets, utility filings, and industry studies, we assess demand growth, reliability requirements, interconnection thresholds, and infrastructure needs at substations and feeders. The analysis highlights the mismatch between fast data center development timelines and slower utility planning and construction cycles, as well as strategies such as phased energization, on-site generation, hosting capacity maps, and structured interconnection frameworks. While focused on data centers, the insights also apply to other high-density loads such as advanced manufacturing, hydrogen production, and electrified transportation. The report concludes with approaches to align planning processes, transparency tools, and regulatory frameworks so utilities can manage new large loads in ways that support a reliable and resilient grid.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Particle Swarm Optimization of Dynamic Load Model Parameters in Large Systems

This paper considers two dynamic load models that are widely used in industry to account for induction motor behavior: CMLD and CLOD. These models must be parametrized for the specific utility system in a general way so that they can be used in planning studies and provide a conservative but realistic representation of load behavior. This study considers a measurement-based approach to tuning both models. The load modeling study compares the response of the tuned models to generic candidate models using historical events. This study considers one area-based subsystem to simplify the modeling approach and reduce the number of models required for simulations. Additionally, because dynamic load models often produce similar results for different sets of parameters, a sensitivity study was conducted to assess the parameter impacts on the voltage response. The sensitivity study covers the parameters that are tuned using event measurements. The process to estimate the parameters uses the particle-swarm optimization algorithm. Overall, the performance of the tuned model more accurately captures recovery voltage, delayed recovery, and settling voltage than its predecessor models while not being overly tuned so that it remains general for peak summer conditions.

dynamic load modeling↗

Resource and Load Compatibility Assessment of Wind Energy Offshore of Humboldt County, California

Floating offshore wind is being considered in northern California as indicated by the Bureau of Ocean Energy Management’s issuance of a lease consideration in the Humboldt Call Area. Humboldt County offers access to this enormous resource, but local electric load and transmission are limited. The potential impacts of offshore wind generators at three different scales were studied using a regional grid model of Humboldt County. Offshore wind generation was calculated using modeled wind speed data and 12-MW turbine specifications and integrated with projected load and historical generation. Offshore wind farms deployed in the Humboldt Call Area achieve annual capacity factors between 45% and 54% after losses and maintenance. Power output is variable between and within seasons, with full power output 30% of the time and no output approximately 20% of the time. Electricity from a 48-MW wind farm provides 22% of regional load with limited exports. A 144-MW wind farm serves 38% of local load, exporting 40% of its electricity with the extant 70-MW transmission capacity. A full build-out of 1836 MW would result in 88% curtailment with existing transmission. Across scenarios, offshore wind variability necessitates reliance on existing power plants to meet local demand in periods of low wind.

17 WIND ENERGY↗

Nontargeted vs. Targeted vs. Smart Load Shifting Using Heat Pump Water Heaters

Deployment of CTA-2045–enabled devices is increasing in the U.S. market. These devices allow utilities or third-party aggregators to control appliance energy use in homes, and could also be applied to end uses in small commercial buildings. This study focuses on a field study using CTA-2045–enabled water heaters to shift electric load off the peak and toward periods when renewable resources are more prevalent (e.g., near noon for solar resources and near midnight for wind resources). The following load shifting strategies were compared to understand effects on the aggregate load-shifting capabilities of Heat Pump Water Heaters (HPWHs) and on consumer hot water supply: non-targeted (traditional), targeted (grouped, with different shifting schedules) and “smart” (adaptive control commands). The results of this study show that targeted and smart control strategies yield significantly more load-shifting potential from a population of water heaters than the non-targeted approach without sacrificing hot water supply to occupants. However, as control commands become more aggressive, aggregators may face challenges in meeting consumer hot water demand. Furthermore, the findings and lessons learned can benefit electric utilities and inform updates to manufacturer controls and communications standards. The data collected may also be useful for developing and validating HPWH models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utilization of Additive Manufacturing for the Rapid Prototyping of C-Band Radiofrequency Loads

Additive manufacturing is a versatile technique that shows promise in providing quick and dynamic manufacturing for complex engineering problems. Research has been ongoing into the use of additive manufacturing for potential applications in radiofrequency (RF) component technologies. Here, we present a method for developing an effective prototype load produced from 316L stainless steel on a direct metal laser sintering machine. The model was tested using simulation software to verify the validity of the design. The load structure was manufactured by an online digital manufacturing company, showing the viability of using easily accessible tools to manufacture RF structures. The produced load was able to produce an S11 value of −22.8 dB at a C-band frequency of 5.712 GHz while under a vacuum. In a high-power test, the load was able to terminate a peak power of 8.1 MW. The discussion includes future applications of the present method and how it will help to improve the implementation of future accelerator concepts.

36 MATERIALS SCIENCE↗

Load Factor and Unserved Energy Webinar

This presentation consists of slides from a webinar given on October 25, 2019. The slides give an overview of load factor forecasting and how it can be incorporated into energy and power demand forecasts, with a special eye towards accounting for unserved energy. It includes case studies from other countries, highlighting how load factor is used in their individual load forecasts. The slides then review and compare various load forecasts for Pakistan's electricity grid.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Aeroelastic Modeling and Full-Scale Loads Measurements for Investigation of Single-Axis PV Tracker Wind-Driven Dynamic Instabilities

While wind tunnel testing and proprietary industry modeling tools have been used for years to design and develop PV tracker systems, wind induced dynamic failures are becoming more prevalent and high visibility. Designers and manufactures have reacted by developing new systems or add-on products to improve system dynamics adding to overall system costs. To better understand the physics and aeroelastic behavior that leads to dynamic instabilities NREL researches have taken up a first of a kind study to both develop open source aeroelastic modeling tools and measure tracker loads on a single axis full-scale tracker system at a high wind site. These modeling tools can simulate the fluid-structure interaction driving torsional instabilities under a wide range of turbulent inflow conditions and stow angles. The results of these simulations reveal the flow features associated with panel rotation and the induced loads in the structure. The experimental load measurements can be used to validate models and provide a quantifiable understanding of tracker dynamics, critical loads paths, identify instability markers, inform resilient design, and suggest the most favorable stow approach.

14 SOLAR ENERGY↗