Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOCATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Bone Fractures Following External Beam Radiotherapy and Limb-Preservation Surgery for Lower Extremity Soft Tissue Sarcoma: Relationship to Irradiated Bone Length, Volume, Tumor Location and Dose

Purpose: To examine the relationship between tumor location, bone dose, and irradiated bone length on the development of radiation-induced fractures for lower extremity soft tissue sarcoma (LE-STS) patients treated with limb-sparing surgery and radiotherapy (RT). Methods and Materials: Of 691 LE-STS patients treated from 1989 to 2005, 31 patients developed radiation-induced fractures. Analysis was limited to 21 fracture patients (24 fractures) who were matched based on tumor size and location, age, beam arrangement, and mean total cumulative RT dose to a random sample of 53 nonfracture patients and compared for fracture risk factors. Mean dose to bone, RT field size (FS), maximum dose to a 2-cc volume of bone, and volume of bone irradiated to >=40 Gy (V40) were compared. Fracture site dose was determined by comparing radiographic images and surgical reports to fracture location on the dose distribution. Results: For fracture patients, mean dose to bone was 45 +- 8 Gy (mean dose at fracture site 59 +- 7 Gy), mean FS was 37 +- 8 cm, maximum dose was 64 +- 7 Gy, and V40 was 76 +- 17%, compared with 37 +- 11 Gy, 32 +- 9 cm, 59 +- 8 Gy, and 64 +- 22% for nonfracture patients. Differences in mean, maximum dose, and V40 were statistically significant (p = 0.01, p = 0.02, p = 0.01). Leg fractures were more common above the knee joint. Conclusions: The risk of radiation-induced fracture appears to be reduced if V40 <64%. Fracture incidence was lower when the mean dose to bone was <37 Gy or maximum dose anywhere along the length of bone was <59 Gy. There was a trend toward lower mean FS for nonfracture patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proton Stereotactic Body Radiation Therapy for Clinically Challenging Cases of Centrally and Superiorly Located Stage I Non-Small-Cell Lung Cancer

Purpose: To minimize toxicity while maintaining tumor coverage with stereotactic body radiation therapy (SBRT) for centrally or superiorly located stage I non-small-cell lung cancer (NSCLC), we investigated passive-scattering proton therapy (PSPT) and intensity-modulated proton therapy (IMPT). Methods and Materials: Fifteen patients with centrally or superiorly located (within 2 cm of critical structures) stage I NSCLC were treated clinically with three-dimensional photon SBRT (50 Gy in 4 fractions). The photon SBRT plan was compared with the PSPT and IMPT plans. The maximum tolerated dose (MTD) was defined as the dose that exceeded the dose--volume constraints in the critical structures. Results: Only 6 photon plans satisfied the >95% planning target volume (PTV) coverage and MTD constraints, compared to 12 PSPT plans (p = 0.009) and 14 IMPT plans (p = 0.001). Compared with the photon SBRT plans, the PSPT and IMPT plans significantly reduced the mean total lung dose from 5.4 Gy to 3.5 Gy (p < 0.001) and 2.8 Gy (p < 0.001) and reduced the total lung volume receiving 5 Gy, 10 Gy, and 20 Gy (p < 0.001). When the PTV was within 2 cm of the critical structures, the PSPT and IMPT plans significantly reduced the mean maximal dose to the aorta, brachial plexus, heart, pulmonary vessels, and spinal cord. Conclusions: For centrally or superiorly located stage I NSCLC, proton therapy, particularly IMPT, delivered ablative doses to the target volume and significantly reduced doses to the surrounding normal tissues compared with photon SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proton Beam Therapy for Hepatocellular Carcinoma Located Adjacent to the Alimentary Tract;Proton beam therapy; Hepatocellular carcinoma; Gastrointestinal bleeding

Purpose: To evaluate the safety and effectiveness of proton beam therapy for hepatocellular carcinoma (HCC) located adjacent to the alimentary tract. Patients and Methods: Forty-seven patients (median age, 69 years; range, 43-82 years) who had HCC located within 2 cm of the alimentary tract underwent proton beam therapy. Liver damage according to the Child-Pugh classification was Class A in 35 patients, Class B in 9, and Class C in 3. Treatment protocols of the early 16 patients and the late 31 patients were 72.6 GyE in 22 fractions and 77 GyE in 35 fractions, respectively. Results: During the median follow-up period of 23 months, 24 patients died; the remaining 23 patients were alive until September 2008. The median overall survival was 33.9 months (95% confidence interval [CI], 10.8-57.0 months). Actuarial overall and local progression-free survival rates at 3 years were 50.0% and 88.1%, respectively. Grade 2 and 3 alimentary tract hemorrhage was observed in 3 (6.4%) and 1 (2.1%) patients, respectively. Conclusions: Our proton beam therapy strategy for HCC located adjacent to the alimentary tract seems to be effective but should be performed with caution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Helical Tomotherapy in Stereotactic Body Radiation Therapy for Centrally Located Early Stage Non-Small-Cell Lung Cancer or Lung Metastases

Purpose: To investigate the ability of helical tomotherapy (HT) to spare critical organs immediately adjacent to the tumor target in stereotactic body radiation therapy (SBRT) for centrally located lung lesions. Methods and Materials: HT SBRT plans for 10 patients with centrally located lesions or lesions immediately adjacent to a critical structure were generated. A total of 70 Gy in 10 fractions was prescribed to the planning target volume (PTV) to satisfy a target volume coverage of {>=}95% PTV receiving 70 Gy and an established set of dose constraints for the organs at risk (OARs). Quality assurance (QA) of the HT plans was performed with both ion chamber and film measurements. Results: The PTV coverage criteria was met with 95% of the PTV receiving 70.68 {+-} 0.33 Gy for all cases even though the OARs immediately adjacent to the PTV ranged from 0.38 to 0.85 cm away. The mean lung dose (MLD), and V{sub 20} were 7.15 {+-} 1.44 Gy, and 11.93 {+-} 3.24 % for the total lung, respectively. The dose parameters of MLD, V{sub 5}, V{sub 10}, and V{sub 20} for the contralateral lung were significantly lower than those for the ipsilateral lung (p < 0.05). An average dose fall off from the PTV periphery to the edge of the immediately adjacent OAR was 47.6% over an average distance of 4.87 mm. Comparison of calculated and measured doses with the ion chamber showed an average of 1.85% point dose error, whereas an average mean gamma and the area with a gamma larger than 1 of 0.20 and 0.94% were observed, respectively. Conclusion: HT allows the sparing of critical structures immediately adjacent to the tumor target, thus making SBRT for these centrally located lesions feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accurate Analysis of the Change in Volume, Location, and Shape of Metastatic Cervical Lymph Nodes During Radiotherapy

Purpose: To establish a method for the accurate acquisition and analysis of the variations in tumor volume, location, and three-dimensional (3D) shape of tumors during radiotherapy in the era of image-guided radiotherapy. Methods and Materials: Finite element models of lymph nodes were developed based on computed tomography (CT) images taken before the start of treatment and every week during the treatment period. A surface geometry map with a volumetric scale was adopted and used for the analysis. Six metastatic cervical lymph nodes, 3.5 to 55.1 cm{sup 3} before treatment, in 6 patients with head and neck carcinomas were analyzed in this study. Three fiducial markers implanted in mouthpieces were used for the fusion of CT images. Changes in the location of the lymph nodes were measured on the basis of these fiducial markers. Results: The surface geometry maps showed convex regions in red and concave regions in blue to ensure that the characteristics of the 3D tumor geometries are simply understood visually. After the irradiation of 66 to 70 Gy in 2 Gy daily doses, the patterns of the colors had not changed significantly, and the maps before and during treatment were strongly correlated (average correlation coefficient was 0.808), suggesting that the tumors shrank uniformly, maintaining the original characteristics of the shapes in all 6 patients. The movement of the gravitational center of the lymph nodes during the treatment period was everywhere less than {+-}5 mm except in 1 patient, in whom the change reached nearly 10 mm. Conclusions: The surface geometry map was useful for an accurate evaluation of the changes in volume and 3D shapes of metastatic lymph nodes. The fusion of the initial and follow-up CT images based on fiducial markers enabled an analysis of changes in the location of the targets. Metastatic cervical lymph nodes in patients were suggested to decrease in size without significant changes in the 3D shape during radiotherapy. The movements of the gravitational center of the lymph nodes were almost all less than {+-}5 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of the number and locations of the calibration stations needed to monitor soil moisture using distributed temperature sensing systems: A proof-of-concept study

The single-probe heat-pulse (SPHP) technique combined with the Fiber-optic Distributed Temperature Sensing (DTS) technology can offer novel high-resolution measurements of soil moisture (θ) over spatial scales ranging from several centimeters to several kilometers. However, the key limitation of this method is in obtaining the calibration relationship between θ and soil thermal conductivity (λ) across a specific field. In a previous study, a new methodology using a Gaussian processes model was presented to account for the spatial variability in the λ-θ relationship. The model aggregated θ measurements from soil moisture sensors scattered over the SPHP transect with the corresponding DTS λ measurements at their locations. In this study, a novel methodology is tested to optimize the number and locations of soil moisture sensors required to account for the spatial variability of the λ - θ relationship to achieve higher accuracy from the SPHP technique. The proposed methodology utilizes hierarchical clustering to analyze the information contained in the spatial structure of the SPHP measurements as the soil dries from a nearly-saturated condition. The proposed methodology was tested using data from a field in Oklahoma. Monte-Carlo simulation was performed to validate the performance of the proposed methodology. The predictions obtained from the proposed methodology resulted in θ measurements accuracy comparable to those obtained from the 10% best Monte-Carlo iterations of randomly assigned soil moisture locations. Further, this study demonstrates that the proposed methodology is more efficient than the traditional practice of randomly spreading calibration soil moisture sensors along the SPHP transect.

54 ENVIRONMENTAL SCIENCES↗

Aperture size distribution, length, and preferential location of bed-parallel veins in shale

Bed-parallel, calcite-filled veins (BPVs) are common in shale formations, and although they have been widely described in other studies, little is known about their population aperture size distribution. To address this knowledge gap, we analyzed BPV sizes in outcrops and cores from the Vaca Muerta Formation, Neuquén Basin, Argentina; in two cores from the Marcellus Formation, Appalachian Basin, northeast Pennsylvania; and in one core from the Wolfcamp Shale, Delaware Basin, West Texas. Nine out of ten aperture size populations follow a negative exponential distribution, with one following a weak power law. Bed-parallel vein size distribution and intensity vary among formations and within the same shale. We define three groups of distributions: (1) Vaca Muerta outcrops, with the highest BPV intensity and the largest BPVs (cumulative frequency of 4.9 BPVs per meter [BPVs/m] for apertures 0.265 mm to 8.7 cm); (2) Vaca Muerta cores with a similar BPV intensity overall but with no apertures wider than 1.2 cm; and (3) Vaca Muerta, Wolfcamp, and Marcellus cores with the fewest BPVs (cumulative frequency up to 0.63 BPVs/m) and very few wider than 1 cm. Aperture and length in two outcrop data sets are weakly positively correlated and follow power laws with exponents of 0.44 and 0.49. Mechanical interfaces at boundaries between different lithologies exert a strong control on BPV location, with 65–75% of observed interfaces having BPVs along them. Only 25–30% of the BPVs occur at observed material interfaces, however, and unless subtle, unobserved mechanical layering is present, other factors must also control location. BPV intensity and organic richness (TOC) from Vaca Muerta well logs are correlated in some instances but not in others, indicating TOC is not always a good proxy for BPV location or intensity. Furthermore, these findings provide useful information for modeling of hydraulic fracture treatments where BPVs may influence development of the stimulated fracture network, for example by limiting height growth.

58 GEOSCIENCES↗

Using a thermoluminescent dosimeter to evaluate the location reliability of the highest–skin dose area detected by treatment planning in radiotherapy for breast cancer

Acute skin reaction during adjuvant radiotherapy for breast cancer is an inevitable process, and its severity is related to the skin dose. A high–skin dose area can be speculated based on the isodose distribution shown on a treatment planning. To determine whether treatment planning can reflect high–skin dose location, 80 patients were collected and their skin doses in different areas were measured using a thermoluminescent dosimeter to locate the highest–skin dose area in each patient. We determined whether the skin dose is consistent with the highest-dose area estimated by the treatment planning of the same patient. The χ{sup 2} and Fisher exact tests revealed that these 2 methods yielded more consistent results when the highest-dose spots were located in the axillary and breast areas but not in the inframammary area. We suggest that skin doses shown on the treatment planning might be a reliable and simple alternative method for estimating the highest skin doses in some areas.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluating the consistency of location of the most severe acute skin reaction and highest skin dose measured by thermoluminescent dosimeter during radiotherapy for breast cancer

We conducted this prospective study to evaluate whether the location of the most severe acute skin reaction matches the highest skin dose measured by thermoluminescent dosimeter (TLD) during adjuvant radiotherapy (RT) for patients with breast cancer after breast conservative surgery. To determine whether TLD measurement can reflect the location of the most severe acute skin reaction, 80 consecutive patients were enrolled in this prospective study. We divided the irradiated field into breast, axillary, inframammary fold, and areola/nipple areas. In 1 treatment session when obvious skin reaction occurred, we placed the TLD chips onto the 4 areas and measured the skin dose. We determined whether the highest measured skin dose area is consistent with the location of the most severe skin reaction. The McNemar test revealed that the clinical skin reaction and TLD measurement are more consistent when the most severe skin reaction occurred at the axillary area, and the p = 0.0108. On the contrary, TLD measurement of skin dose is less likely consistent with clinical observation when the most severe skin reaction occurred at the inframammary fold, breast, and areola/nipple areas (all the p > 0.05). Considering the common site of severe skin reaction over the axillary area, TLD measurement may be an appropriate way to predict skin reaction during RT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Use of multiple tools including lead isotopes to decipher sources of ozone and reactive mercury to urban and rural locations in Nevada, USA

Ambient air particulate matter (< 2.5 μm in diameter) samples were collected on two different filter types in 2014 and 2015 over 24 h periods and analyzed for reactive mercury (gaseous oxidized mercury + particulate bound mercury) concentrations and lead isotopes to determine sources of pollution to three sites in Nevada, USA. Two sites were located on the western edge of Nevada (Reno, urban, 1370 m and Peavine Peak, rural, high elevation, 2515 m); the third location was ~ 485 km east in rural Great Basin National Park, NV (2061 m). Reactive mercury samples were collected on cation exchange membranes simultaneously with lead samples, collected on Teflon membranes. Lead isotopic ratios have previously identified trans-Pacific lead sources based on the 206/207 and 208/207 lead ratios. Influence from trans-Pacific air masses was higher from March to June associated with long-range transport of pollutants. Spring months are well known for increased transport across the Pacific; however, fall months were also influenced by trans-Pacific air masses in this study. Western North American background ozone concentrations have been measured and modeled at 50 to 55 ppbv. Median ozone concentrations at both rural sites in Nevada were within this range. Sources leading to enhancements in ozone of 2 to 18 ppbv above monthly medians in Nevada included emissions from Eurasia, regional urban centers, and global and regional wildfires, resulting in concentrations close to the USA air quality standard. At the high elevation locations, ozone was derived from pollutants being transported in the free troposphere that originate around the globe; however, Eurasia and Asia were dominant sources to the Western USA. Negative correlations between reactive mercury and percent Asian lead, Northern Eurasia and East Asia trajectories indicated reactive mercury concentrations at the two high elevation sites were produced by oxidants from local, regional, and marine boundary layer sources.

54 ENVIRONMENTAL SCIENCES↗

Nuclear location of minor capsid protein L2 is required for expression of a reporter plasmid packaged in HPV51 pseudovirions

The deduced amino acid (aa) sequence of L2 of the newly sequenced HPV51 strain, isolated by Matsukura and Sugase (Ma-strain), was markedly different from that of the prototype HPV51 isolated by Nuovo et al. (Nu-strain) (GenBank (M62877)) in two regions: aa 95-99 (region I) and aa 179-186 (region II). The two regions of Ma-strain were homologous to those of the other mucosal HPVs. The aa sequences of the N-terminal and C-terminal regions of Ma-L2 and Nu-L2 were identical and contained the nuclear localizing signal (NLS). When expressed in HEK293 cells, Ma-strain L2 (Ma-L2) was located in the nucleus but Nu-strain L2 (Nu-L2), in the cytoplasm. The chimeric L2s having both Nu-L2 regions I and II were located in the cytoplasm, and those having one of them were located both in the nucleus and cytoplasm, suggesting that Nu-L2 regions I and II inhibit the NLS function. For a better understanding of a role of L2 in infection, pseudovirion (PV) preparations were produced with a reporter, Ma-strain L1, and various L2s (Ma-L2, Nu-L2, or the chimeric L2s). These PV preparations contained structurally similar particles composed of L1 and L2 and the packaged reporter plasmid at a similar level. The reporter expression was not induced in HEK293 cells after inoculation with PVs containing the L2s that are incapable of localizing in the nucleus when expressed alone. Among PVs containing L2s capable of localizing in the nucleus, the reporter expression was induced only by PVs containing Ma-L2 region I. Thus, the results indicate that the expression of the reporter in the HPV51 PV requires the nuclear localizing ability of L2 and another unknown function associated with region I.

60 APPLIED LIFE SCIENCES↗

A multiobjective modeling approach to locate multi-compartment containers for urban-sorted waste

The location of multi-compartment sorted waste containers for recycling purposes in cities is an important problem in the context of urban waste management. The costs associated with those facilities and the impacts placed on populations are important concerns. This paper introduces a mixed-integer, multiobjective programming approach to identify the locations and capacities of such facilities. The approach incorporates an optimization model in a Geographical Information System (GIS)-based interactive decision support system that includes four objectives. The first objective minimizes the total investment cost; the second one minimizes the average distance from dwellings to the respective multi-compartment container; the last two objectives address the 'pull' and 'push' characteristics of the decision problem, one by minimizing the number of individuals too close to any container, and the other by minimizing the number of dwellings too far from the respective multi-compartment container. The model determines the number of facilities to be opened, the respective container capacities, their locations, their respective shares of the total waste of each type to be collected, and the dwellings assigned to each facility. The approach proposed was tested with a case study for the historical center of Coimbra city, Portugal, where a large urban renovation project, addressing about 800 buildings, is being undertaken. This paper demonstrates that the models and techniques incorporated in the interactive decision support system (IDSS) can be used to assist a decision maker (DM) in analyzing this complex problem in a realistically sized urban application. Ten solutions consisting of different combinations of underground containers for the disposal of four types of sorted waste in 12 candidate sites, were generated. These solutions and tradeoffs among the objectives are presented to the DM via tables, graphs, color-coded maps and other graphics. The DM can then use this information to 'guide' the IDSS in identifying additional solutions of potential interest. Nevertheless, this research showed that a particular solution with a better objective balance can be identified. The actual sequence of additional solutions generated will depend upon the objectives and preferences of the DM in a specific application.

97 MATHEMATICS AND COMPUTING↗

Capacitated location of collection sites in an urban waste management system

Urban waste management is becoming an increasingly complex task, absorbing a huge amount of resources, and having a major environmental impact. The design of a waste management system consists in various activities, and one of these is related to the location of waste collection sites. In this paper, we propose an integer programming model that helps decision makers in choosing the sites where to locate the unsorted waste collection bins in a residential town, as well as the capacities of the bins to be located at each collection site. This model helps in assessing tactical decisions through constraints that force each collection area to be capacitated enough to fit the expected waste to be directed to that area, while taking into account Quality of Service constraints from the citizens' point of view. Moreover, we propose an effective constructive heuristic approach whose aim is to provide a good solution quality in an extremely reduced computational time. Computational results on data related to the city of Nardo, in the south of Italy, show that both exact and heuristic approaches provide consistently better solutions than that currently implemented, resulting in a lower number of activated collection sites, and a lower number of bins to be used.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Description of the code ANVIL (ANisotropic Vhf Impulse Location)

In this paper, we have developed a general, three-dimensional method to locate sources of earth-directed radiation which takes into account the flight paths of reflected signals. While time-of-arrival algorithms exist for locating radio sources using line-of-sight propagation paths, radio sources originating above the surface of the earth will not necessarily emit strong power along direct paths to satellites. A combination of direct and ground-reflected pulses or only ground-reflected signals from such sources could be received by satellite-borne sensors. The work presented here applies to satellite detection of sub-ionospheric radio sources in a vacuum environment with ideal reflection off the earth's surface. Because satellites are not static receivers, their configuration with respect to a radio source is not always optimal. Therefore, a statistical study is performed using 1000 randomized configurations of 24 satellites in middle earth orbit. For each configuration, the radio source latitude and longitude is fixed, and its altitude is varied from 1 to 97 km. An analytic direct-path algorithm using the five satellites nearest the radio source provides an initial guess for the radio source latitude and longitude. We find that, using this approximation, the mean error in the calculated nadir location has a maximum value of 134 m for the 97-km source altitude. The coordinates of the initial guess are used to define the origin of a grid within which an all-points search refinement is performed. Finally, using this procedure, the overall maximum mean error in radio source position is found to be on the order of the computational grid size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimating Permafrost Distribution Using Co‐Located Temperature and Electrical Resistivity Measurements

Abstract Assessing the lateral and vertical extent of permafrost is critical to understanding the fate of Arctic ecosystems under climate change. Yet, direct measurements of permafrost distribution and temperature are often limited to a small number of borehole locations. Here, we assess the use of co‐located shallow temperature and electrical resistivity tomography (ERT) measurements to estimate at high‐resolution the distribution of permafrost in three watersheds underlain by discontinuous permafrost. Synthetic modeling shows that co‐located temperature and ERT measurements allow for supervised classification schemes that provide 60% higher accuracy compared to unsupervised methods. Linking resistivity and size of the identified permafrost bodies to surface observations, we show that tall vegetation (>0.5 m) and gentle slopes (<15°) are related to warmer and smaller permafrost bodies, and a more frequent occurrence of taliks.

54 ENVIRONMENTAL SCIENCES↗

Lipid bilayer thickness determines cholesterol's location in model membranes

Cholesterol is an essential biomolecule of animal cell membranes, and an important precursor for the biosynthesis of certain hormones and vitamins. It is also thought to play a key role in cell signaling processes associated with functional plasma membrane microdomains (domains enriched in cholesterol), commonly referred to as rafts. In all of these diverse biological phenomena, the transverse location of cholesterol in the membrane is almost certainly an important structural feature. Using a combination of neutron scattering and solid-state 2 H NMR, we have determined the location and orientation of cholesterol in phosphatidylcholine (PC) model membranes having fatty acids of different lengths and degrees of unsaturation. The data establish that cholesterol reorients rapidly about the bilayer normal in all the membranes studied, but is tilted and forced to span the bilayer midplane in the very thin bilayers. The possibility that cholesterol lies flat in the middle of bilayers, including those made from PC lipids containing polyunsaturated fatty acids (PUFAs), is ruled out. Finally, these results support the notion that hydrophobic thickness is the primary determinant of cholesterol's location in membranes.

59 BASIC BIOLOGICAL SCIENCES↗

Chapter 8: A 'Global' View on Bifacial Gain: Dependence on Geographic Location and Environmental Conditions

The simulation results presented in this chapter demonstrate how bifacial PV systems can bring a performance gain all around the globe, resolving a certain misbelief that they may only form a niche market restricted to specific locations or installations. Global predictions, based on irradiance, indicate bifacial gains in the order of 50% of the natural albedo for equator-facing systems with optimized tilt angle. In locations with low clearness index, the bifacial gain can even be higher. At system level the bifacial gain will be reduced by 20% to 50% relative to a free-standing panel, due to increased self-shading and to limitation of the diffuse irradiance on the rear by adjacent sheds. Even though the rear side irradiance of a bifacial module is inherently inhomogeneous, due to self-shading and external mounting structures, our simulations have shown that the RSD of the total irradiance does not exceed 5%, even at very high albedo, and will usually be much smaller. The simulation methods applied in this chapter and their ongoing integration into commercially available software tools, like PVsyst, will give system designers and installers more visibility on the configuration layout of a bifacial PV plant at their specific location, the associated bifacial gain and the effect on their return on investment.

14 SOLAR ENERGY↗

Travelling wave‐based fault detection and location in a real low‐voltage DC microgrid

Abstract This paper discusses a device‐level implementation of a travelling wave (TW) protection device (PD) designed for a real low‐voltage DC microgrid. The TWPD fault detection and location algorithm is executed on a commercial digital signal processor (DSP) board, involving signal sampling at 1 MHz via the DSP board's analog‐to‐digital converter (ADC). The analogue input card measures positive pole, negative pole and pole‐to‐pole voltages at the TWPD location. Upon a successful fault detection using a second‐order high‐pass filter, the voltage data is normalised and multi‐resolution analysis (MRA) is performed on a 128‐sample buffer around the TW arrival time. MRA employs the discrete wavelet transform (DWT) to capture high‐frequency voltage patterns, and then the Parseval's energy theorem quantifies these TW characteristics by computing the energy of reconstructed wavelet coefficients. These energy values per decomposed frequency band are the basis for training a random forest classifier that predicts fault location and type. The TWPD is fully implemented and connected to a real DC microgrid in Albuquerque, NM, USA, for validation, and results are shown for field tests verifying the performance under faults.

Paruthiyil, Sajay Krishnan [Department of Electric↗