Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC GUIDE FIELD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

The evolution of the ion diffusion region during collisionless magnetic reconnection in a force-free current sheet

Two-dimensional particle-in-cell simulation is performed to investigate magnetic reconnection in a force-free current sheet. The results show that the evolution of the ion diffusion region has two different phases. In the first phase, the electrons flow toward the X line along one pair of separatrices and away from the X line along the other pair of separatrices. Therefore, in the ion diffusion region, a distorted quadrupole structure of the out-of-plane magnetic field is formed, which is similar to that of a typical guide field reconnection in the Harris current sheet. In the second phase, the electrons move toward the X line along the separatrices and then flow away from the X line at the inner side of the separatrices. In the ion diffusion region, the out-of-plane magnetic field exhibits a characteristic quadrupole pattern with a good symmetry, which is similar to that of antiparallel reconnection in the Harris current sheet.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling the Effects of Drift Orbit Bifurcation on Radiation Belt Electrons

Abstract Drift orbit bifurcation (DOB) has been suggested to play a major role in the loss and transport of radiation belt electrons since it violates the second adiabatic invariants of particles and makes the third invariant undefined. Results from our guiding‐center test particle simulations using the Tsyganenko‐1989c magnetic field model show that the DOB could affect a broad region of the outer radiation belt, which can penetrate inside the geosynchronous orbit at Kp ≥ 3, and its effects are more significant further away from the Earth, at a higher Kp and for higher electron energies. Specifically, the short‐term simulation results after one electron drift show both traditional and nontraditional DOB transport of electrons, with the nontraditional DOB, caused by a third minimum of the magnetic field strength near the equator, reported here for the first time. Moreover, our results show large ballistic jumps in the second invariant and radial distance for electrons at high equatorial pitch angles after one drift. In addition, long‐term DOB transport coefficients of electrons over many drifts are calculated based on our simulation results. We find that the pitch angle and radial diffusion coefficients of electrons due to DOB could be comparable to or even larger than those caused by electron interactions with chorus and Ultra‐Low‐Frequency waves, respectively. In sum, our results demonstrate that DOB could cause effective loss and transport of radiation belt electrons even in the absence of waves.

Astronomy & Astrophysics↗

Lateral hot electron transport and ion acceleration in femtosecond laser pulse interaction with thin foils

Hot electron transport along the target surface out of the laser-irradiated spot plays an important role in such applications as ion acceleration or fast ignition of fusion reactions. In this paper, the lateral electron transport in a thin foil, limited in transverse sizes, is studied by numerical particle-in-cell simulations for two linear polarizations (p and s) of femtosecond laser pulse incident on a foil at various angles. Two mechanisms of the transport are identified: the first one is due to hot electron recirculation across the foil and the second is electron guiding along the foil surface by quasistatic magnetic and electric fields. It is demonstrated that the second mechanism takes place for larger incidence angles, although the recirculation is still important. The ions accelerated from a lateral foil edge, which is out of the laser focal spot, can have higher energies than the ions from the rear foil side.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-J-200: Operation of An Electron Accelerator On An Integrated MR-Linac System

Purpose: An integrated MRI guided radiotherapy system poses a challenge of operating a linear accelerator in the presence of a magnetic field as the magnetic force acting on the electrons could Result in radiation source displacement and subsequent reduction of dose output. It was the purpose of this work to test the performance of a linac in the presence of a 1.5T MRI system. Methods: The first experimental MRI guided radiotherapy system at UMC-Utrecht consisting of an Elekta linac rotating around a 1.5T Magnex magnet was examined. A passive magnetic shield was simulated, designed and installed to reduce the influence of the MRI magnet stray field on the electron beamline. The B field inside the shield was measured as a function of gantry angle and measurements of dose rate constancy upon gantry rotation were performed. Results: The magnitude of the magnetic field on the electron beam path without the shield was as high as 70G. It varied by up to 15G with gantry rotation due to the presence of metal beams in the bunker floor which resulted in dose output drop of up to 70% at certain gantry angles. With the prototype shield, field magnitude was reduced to well below 0.5G everywhere along the electron beam path. Field variation with gantry rotation was decreased to below 0.2G and enabled dose output of the linac to be recovered at all gantry angles. The homogeneity of the field inside the MRI magnet has not been compromised. Conclusion: It was demonstrated that the influence of the 1.5T magnet and the bunker design on the linac operation has been minimised. The performance will be further improved on the Elekta Atlantic system which incorporates a newly developed and optimised Philips magnet design and bunker construction. J Harasimowicz, D Roberts, I Shinton and S Sund are employed by Elekta Limited Crawley, H Wang and M Zhong are employed by Elekta Beijing Medical Systems Co. Ltd., J Overweg is employed by Philips Technologie GmbH Forschungslaboratorien.

60 APPLIED LIFE SCIENCES↗

Experimental observation of a field-aligned ion beam produced by magnetic reconnection of two flux ropes

An ion beam field-aligned to the background guide field ($B$ 0 = $330$ G) was observed in a reconnection experiment on the Large Plasma Device and, to the authors' knowledge, is the first experimental observation of its kind. Two kink-unstable flux ropes ( L = 11 m, d = 7.6 cm) were made to collide, which allows magnetic reconnection to occur. Sub-Alfvénic ion beams with energies of up to 15 eV were then observed from measurements of the local ion energy distribution function. The beam ions do not appear to be heated. Further, they were correlated with the collision of the ropes and appear to be energized by magnetic reconnection. The results and interpretation of the measurements are supported by three-dimensional gyrokinetic particle simulations of the merging flux ropes and electric field measurements from previous experiments [W. Gekelman et al. , Astrophys. J. 853, 33 (2018)]. The mechanism behind the acceleration appears to be non-local.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Zgoubi Users' Guide

The initial version of zgoubi, dedicated to ray-tracing in magnetic fields, was developed by D. Garreta and J.C. Faivre at CEN-Saclay in the early 1970’s. It was perfected for the purpose of studying the four spectrometers SPES I, II, III, IV at the Laboratoire National SATURNE (CEA-Saclay, France), and SPEG at GANIL (Caen, France). It is being used since long in several national and foreign laboratories. The first manual was in French. Accounting for many developments and improvements, and in or der to facilitate access to the program an English version of the manual was written at TRIUMF with the assistance of J. Doornbos. P. Stewart prepared the manuscript for publication. An updating of the latter was necessary for accompanying the third version of the code which included developments regarding spin tracking and ray-tracing in combined electric and magnetic fields; this was done with the help of D. Bunel (SATURNE Laboratory, Saclay) for the preparation of the document and lead to the third release. In the mid-1990s, the computation of synchrotron radiation electromagnetic impulse and spectra was introduced for the purpose of studying interference effects at the LEP synchrotron radiation based diagnostic mini-wiggler. In the mean time, several new optical elements were added, such as electro-magnetic and other electrostatic lenses. Used since several years for special studies in periodic machines (e.g., SATURNE at Saclay, COSY at Julich, LEP and LHC at CERN, Neutrino Factory rings), zgoubi has also undergone extensive developments regarding storage ring related features. These developments of zgoubi have strongly benefited of the environment of the Groupe Théorie, Laboratoire National SATURNE, CEA/DSM-Saclay, in the years 1985-1995. The graphic interface to zgoubi (addressed in Part D) has also undergone concomitant extensive devel opments, which make it a performing tool for the post-processing of zgoubi outputs. The Users’ Guide is intended to describe the contents of the most recent version of zgoubi, which is far from being a “finished product”. Françios Méot

43 PARTICLE ACCELERATORS↗

First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system

The authors report the first magnetic resonance (MR) images produced by their prototype MR system integrated with a radiation therapy source. The prototype consists of a 6 MV linac mounted onto the open end of a biplanar 0.2 T permanent MR system which has 27.9 cm pole-to-pole opening with flat gradients (40 mT/m) running under a TMX NRC console. The distance from the magnet isocenter to the linac target is 80 cm. The authors' design has resolved the mutual interferences between the two devices such that the MR magnetic field does not interfere with the trajectory of the electron in the linac waveguide, and the radiofrequency (RF) signals from each system do not interfere with the operation of the other system. Magnetic and RF shielding calculations were performed and confirmed with appropriate measurements. The prototype is currently on a fixed gantry; however, in the very near future, the linac and MR magnet will rotate in unison such that the linac is always aimed through the opening in the biplanar magnet. MR imaging was found to be fully operational during linac irradiation and proven by imaging a phantom with conventional gradient echo sequences. Except for small changes in SNR, MR images produced during irradiation were visually and quantitatively very similar to those taken with the linac turned off. This prototype system provides proof of concept that the design has decreased the mutual interferences sufficiently to allow the development of real-time MR-guided radiotherapy. Low field-strength systems (0.2-0.5 T) have been used clinically as diagnostic tools. The task of the linac-MR system is, however, to provide MR guidance to the radiotherapy beam. Therefore, the 0.2 T field strength would provide adequate image quality for this purpose and, with the addition of fast imaging techniques, has the potential to provide 4D soft-tissue visualization not presently available in image-guided radiotherapy systems. The authors' initial design incorporates a permanent magnet; however, other types of magnets and field strengths could also be incorporated. Usable MR images were obtained during linac irradiation from the linac-MR prototype. The authors' prototype design can be used as the functional starting point in developing real-time MR guidance offering soft-tissue contrast that can be coupled with tumor tracking for real-time adaptive radiotherapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron acceleration by magnetic islands in a dynamically evolved coronal current sheet

This work simulated the electron acceleration by magnetic islands in a drastically evolved solar coronal current sheet via the combined 2.5-dimensional (2.5D) resistive Magnetohydrodynamics (MHD) and guiding-center approximation test-particle methods. With high magnetic Reynolds number of 105, the long–thin current sheet is evolved into a chain of magnetic islands, growing in size and coalescing with each other, due to tearing instability. The acceleration of electrons is studied in one typical phase when several large magnetic islands are formed. The results show that the electrons with an initial Maxwell distribution evolve into a heavy-tailed distribution and more than 20% of the electrons can be accelerated higher than 200 keV within 0.1 second and some of them can even be energized up to MeV ranges. The most energetic electrons have a tendency to be around the outer regions of the magnetic islands or to be located in the small secondary magnetic islands. We find that the acceleration and spatial distributions of the energetic electrons is caused by the trapping effect of the magnetic islands and the distributions of the parallel electric field E{sub p}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of Coulomb collisions on lower hybrid drift waves inside a laboratory reconnection current sheet

We have developed a local, linear theoretical model for lower hybrid drift waves that can be used for plasmas in the weakly collisional regime. Two cases with typical plasma and field parameters for the current sheet of the magnetic reconnection experiment have been studied. For a case with a low electron beta (β e =0.25, high guide field case), the quasi-electrostatic lower hybrid drift wave is unstable, while the electromagnetic lower hybrid drift wave has a positive growth rate for a high-β e case (β e =8.9, low guide field case). For both cases, including the effects of Coulomb collisions reduces the growth rate but collisional impacts on the dispersion and growth rate are limited (≲20%).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The current status and future direction of high magnetic field science in the United States

This grant provided partial support for the National Research Council (NRC) study that assesses the current status of high magnetic field research in the United States and provides recommendations to guide the future of research and technology development for this area given the needs of user communities and in the context of other programs worldwide. A pdf version of the report is available for download, for free, at http://www.nap.edu/catalog.php?record_id=18355. The science drivers fall into 4 broad areas—(1) condensed matter and materials physics; (2) chemistry, biochemistry, and biology; (3) medical and life science studies; and (4) other fields such as high-energy physics, plasma physics, and particle astrophysics. Among the topics covered in the report’s findings, conclusions, and recommendations are a recognition that there is a continuing need for a centralized facility but also that clear benefits will flow to research communities from decentralized facilities. According to the report, support agencies should evaluate whether to establish such facilities when 32 Tesla superconducting magnets become available. The report also recommends the provision of facilities that combine magnetic fields with scattering facilities and THz radiation sources, and sets out specific magnet goals for magnets needed in several areas of research.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Charged particle motion in electromagnetic fields varying moderately rapidly in space

Electromagnetic fields are considered which vary on the space scale of the geometric mean of the Larmor radius and the much larger scale length of variation of the magnetic field lines. It is first shown that the magnetic moment is an adiabatic invariant, even though the usual arguments for its existence fail. The motion of the guiding center is then examined. For perpendicular drifts in magnitude comparable with the particle speed, the subsequent motion is dominated by electrostatic effects. The motion of particles along the field lines occurs on a much slower time scale than the perpendicular drift time scale. When the guiding center motion is approximately periodic in time, a second adiabatic invariant exists, the magnetic flux enclosed by the almost periodic orbit. When the perpendicular drift is small compared with the particle speed, the parallel motion and the perpendicular drift occur on the same, slow timescale.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TH-AB-BRA-07: PENELOPE-Based GPU-Accelerated Dose Calculation System Applied to MRI-Guided Radiation Therapy

Purpose: The clinical commissioning of IMRT subject to a magnetic field is challenging. The purpose of this work is to develop a GPU-accelerated Monte Carlo dose calculation platform based on PENELOPE and then use the platform to validate a vendor-provided MRIdian head model toward quality assurance of clinical IMRT treatment plans subject to a 0.35 T magnetic field. Methods: We first translated PENELOPE from FORTRAN to C++ and validated that the translation produced equivalent results. Then we adapted the C++ code to CUDA in a workflow optimized for GPU architecture. We expanded upon the original code to include voxelized transport boosted by Woodcock tracking, faster electron/positron propagation in a magnetic field, and several features that make gPENELOPE highly user-friendly. Moreover, we incorporated the vendor-provided MRIdian head model into the code. We performed a set of experimental measurements on MRIdian to examine the accuracy of both the head model and gPENELOPE, and then applied gPENELOPE toward independent validation of patient doses calculated by MRIdian’s KMC. Results: We achieve an average acceleration factor of 152 compared to the original single-thread FORTRAN implementation with the original accuracy preserved. For 16 treatment plans including stomach (4), lung (2), liver (3), adrenal gland (2), pancreas (2), spleen (1), mediastinum (1) and breast (1), the MRIdian dose calculation engine agrees with gPENELOPE with a mean gamma passing rate of 99.1% ± 0.6% (2%/2 mm). Conclusions: We developed a Monte Carlo simulation platform based on a GPU-accelerated version of PENELOPE. We validated that both the vendor provided head model and fast Monte Carlo engine used by the MRIdian system are accurate in modeling radiation transport in a patient using 2%/2 mm gamma criteria. Future applications of this platform will include dose validation and accumulation, IMRT optimization, and dosimetry system modeling for next generation MR-IGRT systems.

60 APPLIED LIFE SCIENCES↗

SLOW MAGNETOACOUSTIC WAVES IN TWO-RIBBON FLARES

We demonstrate that disturbances observed to propagate along the axis of the arcade in two-ribbon solar flares at the speed of a few tens of km s{sup -1}, well below the Alfven and sound speeds, can be interpreted in terms of slow magnetoacoustic waves. The waves can propagate across the magnetic field, parallel to the magnetic neutral line, because of the wave-guiding effect due to the reflection from the footpoints. The perpendicular group speed of the perturbation is found to be a fraction of the sound speed, which is consistent with observations. The highest value of the group speed grows with the increase in the ratio of the sound and Alfven speeds. For a broad range of parameters, the highest value of the group speed corresponds to the propagation angle of 25 deg. - 28 deg. to the magnetic field. This effect can explain the temporal and spatial structure of quasi-periodic pulsations observed in two-ribbon flares.

79 ASTRONOMY AND ASTROPHYSICS↗

The pulsating pulsar magnetosphere

Following the basic principles of a charge-separated pulsar magnetosphere, we consider the magnetosphere to be stationary in space, instead of corotating, and the electric field to be uploaded from the potential distribution on the pulsar surface, set up by the unipolar induction. Consequently, the plasma of the magnetosphere undergoes guiding center drifts of the gyromotion due to the forces transverse to the magnetic field. These forces are the electric force, magnetic gradient force, and field line curvature force. Since these plasma velocities are of drift nature, there is no need to introduce an emf along the field lines, which would contradict the E{sub ∥}=E⋅B=0 plasma condition. Furthermore, there is also no need to introduce the critical field line separating the electron and ion open field lines. We present a self-consistent description where the magnetosphere is described in terms of electric and magnetic fields and also in terms of plasma velocities. The fields and velocities are then connected through the space-charge densities self-consistently. We solve the pulsar equation analytically for the fields and construct the standard steady-state pulsar magnetosphere. By considering the unipolar induction inside the pulsar and the magnetosphere outside the pulsar as one coupled system, and under the condition that the unipolar pumping rate exceeds the Poynting flux in the open field lines, plasma pressure can build up in the magnetosphere, in particular, in the closed region. This could cause a periodic opening up of the closed region, leading to a pulsating magnetosphere, which could be an alternative to pulsar beacons. The closed region can also be opened periodically by the build up of toroidal magnetic field through a positive feedback cycle.

79 ASTRONOMY AND ASTROPHYSICS↗

The effect of grading the atomic number at resistive guide element interface on magnetic collimation

Using 3 dimensional numerical simulations, this paper shows that grading the atomic number and thus the resistivity at the interface between an embedded high atomic number guide element and a lower atomic number substrate enhances the growth of a resistive magnetic field. This can lead to a large integrated magnetic flux density, which is fundamental to confining higher energy fast electrons. This results in significant improvements in both magnetic collimation and fast-electron-temperature uniformity across the guiding. The graded interface target provides a method for resistive guiding that is tolerant to laser pointing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Technical Note: Experimental results from a prototype high-field inline MRI-linac

Purpose: The pursuit of real-time image guided radiotherapy using optimal tissue contrast has seen the development of several hybrid magnetic resonance imaging (MRI)-treatment systems, high field and low field, and inline and perpendicular configurations. As part of a new MRI-linac program, an MRI scanner was integrated with a linear accelerator to enable investigations of a coupled inline MRI-linac system. This work describes results from a prototype experimental system to demonstrate the feasibility of a high field inline MR-linac. Methods: The magnet is a 1.5 T MRI system (Sonata, Siemens Healthcare) was located in a purpose built radiofrequency (RF) cage enabling shielding from and close proximity to a linear accelerator with inline (and future perpendicular) orientation. A portable linear accelerator (Linatron, Varian) was installed together with a multileaf collimator (Millennium, Varian) to provide dynamic field collimation and the whole assembly built onto a stainless-steel rail system. A series of MRI-linac experiments was performed to investigate (1) image quality with beam on measured using a macropodine (kangaroo) ex vivo phantom; (2) the noise as a function of beam state measured using a 6-channel surface coil array; and (3) electron contamination effects measured using Gafchromic film and an electronic portal imaging device (EPID). Results: (1) Image quality was unaffected by the radiation beam with the macropodine phantom image with the beam on being almost identical to the image with the beam off. (2) Noise measured with a surface RF coil produced a 25% elevation of background intensity when the radiation beam was on. (3) Film and EPID measurements demonstrated electron focusing occurring along the centerline of the magnet axis. Conclusions: A proof-of-concept high-field MRI-linac has been built and experimentally characterized. This system has allowed us to establish the efficacy of a high field inline MRI-linac and study a number of the technical challenges and solutions.

60 APPLIED LIFE SCIENCES↗

Efficiency enhancement of nonlinear odd harmonics in thermal free electron laser

The effect of axial energy spread on the radiation of third harmonic is studied in the free electron laser with planar wiggler and ion-channel guiding. Spread in the longitudinal momentum and so in the initial energy of electron beam, without any spread in the transverse velocity, is assumed in the form of Gaussian distribution function. The technique that is employed is a one-dimensional and steady-state simulation. A set of self consistent nonlinear differential equations that describes the system is solved numerically by Runge-Kutta method. Due to the sensitivity of harmonics to thermal effects, gain improvement of third harmonic radiation is achieved by using ion-channel guiding technique and efficiency enhancement is applied by tapering the magnetic field of wiggler to optimize radiation. The bunching parameter of the electron beam is also studied. It is found that the growth of the magnitude of the bunching parameter that is caused by the ponderomotive wave stops before the saturation point of the radiation. This means that ponderomotive wave saturates at a shorter distance compared to the radiation.

43 PARTICLE ACCELERATORS↗

Mimicking surface polaritons for unpolarized light with high-permittivity materials

Tailoring near-field optical phenomena often requires excitation of surface plasmon polaritons (SPPs) or surface phonon polaritons (SPhPs), surface waves at the interface between media with electric permittivities of opposite sign. Despite their unprecedented field confinement, surface polaritons are limited by polarization: only transverse magnetic fields enable their excitation, leaving transverse electric fields unexploited. By contrast, guided modes in positive permittivity materials occur for both linear polarizations, however, they typically cannot compete with SPPs and SPhPs in terms of confinement. Furthermore we show that omnipolarization guided modes in materials with high-permittivity resonances can reach confinement factors similar to SPPs and SPhPs, while surpassing them in terms of propagation distance. We explore the cases of silicon carbide and transition-metal dichalcogenides near their permittivity resonances, and compare with SPhPs in silicon carbide and SPPs in silver, at infrared and visible frequencies, respectively.

36 MATERIALS SCIENCE↗