Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Voltage-driven, local, and efficient excitation of nitrogen-vacancy centers in diamond

Magnetic sensing technology has found widespread application in a diverse set of industries including transportation, medicine, and resource exploration. These uses often require highly sensitive instruments to measure the extremely small magnetic fields involved, relying on difficult-to-integrate superconducting quantum interference devices and spin-exchange relaxation-free magnetometers. A potential alternative, nitrogen-vacancy (NV) centers in diamond, has shown great potential as a high-sensitivity and high-resolution magnetic sensor capable of operating in an unshielded, room-temperature environment. Transitioning NV center–based sensors into practical devices, however, is impeded by the need for high-power radio frequency (RF) excitation to manipulate them. We report an advance that combines two different physical phenomena to enable a highly efficient excitation of the NV centers: magnetoelastic drive of ferromagnetic resonance and NV-magnon coupling. Our work demonstrates a new pathway that combine acoustics and magnonics that enables highly energy-efficient and local excitation of NV centers without the need for any external RF excitation and, thus, could lead to completely integrated, on-chip, atomic sensors.

42 ENGINEERING↗

The relationship between the magnetic field in the Martian magnetotail and upstream solar wind parameters

Magnetic field data measured by the MAGMA instrument in the Martian magnetotail lobes are compared with the ram pressure of the upstream solar wind observed by the TAUS instrument in the circular orbits of the Phobos 2 spacecraft. High correlation was found between the magnetic field intensity in the Martian magnetotail lobes and the solar wind ram pressure. From this relationship the average flaring angle of the Martian magnetotail was determined as approximately 13 deg, and the average magnetosonic Mach number was estimated as approximately 5. The observed relationship between the Martian magnetotail magnetic field intensity and the solar wind magnetic field reflects the correlation of the solar wind magnetic field to the ram pressure providing a value of approximately 7 for the average Alfvenic Mach number. The flaring angle obtained for the Martian magnetotail was found to be an intermediate value between the flaring angle of the magnetotail of the Earth and that of Venus at comparable distances.

Rosenbauer, H.↗

The Viking satellite program - Preliminary results from the APL Magnetic Field Experiment

Sweden's Viking satellite, launched in February 1986, has been conducting plasma process observations in the earth magnetosphere and auroral regions; the U.S.-supplied APL Magnetic Field Experiment aboard Viking is used to determine field-aligned Birkeland current characteristics in previously unsampled regions of near-earth space. The Magnetic Field Experiment has an equivalent spatial resolution of 12 m in the auroral ionosphere when making measurements near apogee. The purposes of Viking's other instruments and their relationship to the Magnetic Field Experiment are discussed.

Potemra, Thomas A.↗

Error field measurements with rotating RMP fields for DIII-D H-mode

3D magnetic sensors are employed to identify the amplitude and toroidal phase of error fields (EF) by analyzing the torque balance for magnetic islands entrained by rotating resonant magnetic perturbations (RMPs) in DIII-D H-mode plasmas. This technique of torque balance allows for efficient error field identification, offering a valuable tool for scenario-specific and optimized error field compensation (EFC) and requires only magnetic diagnostics. The torque balance used in this work includes the contribution from electromagnetic torque due to error fields, wall response, RMP fields, and viscous. Results show that viscous torque plays a crucial role, particularly during locked modes and H-mode plasmas, ensuring accurate data fits with lower residuals. The torque balance technique reveals that the L- and H-mode plasmas have distinct EF configurations, and consistent with a model-based EF analysis including MHD response in IPEC and the SURFMN EF simulation. This technique shows great robustness in measuring the intrinsic EF amplitude regardless of its amplitude or toroidal phase. Repeated discharges with EFC disparities exhibit consistent results of intrinsic error field within a reasonable range near the “standard” error field compensation. Additionally, the use of a rotating n = 1 resonant magnetic perturbation offers the advantage of reducing disruption risks by entraining saturated magnetic islands. These findings are instrumental for optimizing EF correction in fusion devices, thereby enhancing tearing mode suppression and overall plasma stability.

3D magnetic sensors↗

Evolution and dynamics of orphan penumbrae in the solar photosphere: Analysis from multi-instrument observations

We investigate the dynamics and magnetic properties of orphan penumbrae observed in the solar photosphere to understand the formation process of such structures. We observed two orphan penumbrae in active region NOAA 11089 during a coordinated observing campaign carried out in 2010 July, involving the Hinode/Solar Optical Telescope (SOT) and Dutch Open Telescope (DOT), benefiting also from continuous observations acquired by the SDO satellite. We follow their evolution during about three days. The two structures form in different ways: one seems to break off the penumbra of a nearby sunspot, the other is formed through the emergence of new flux. Then they fragment while evolving. The SDO Helioseismic and Magnetic Imager measurements indicate the presence of strong line-of-sight motions in the regions occupied by these orphan penumbrae, lasting for several hours and decreasing with time. This is confirmed by SOT spectro-polarimetric measurements of the Fe I 630.2 nm pair. The latter also show that Stokes parameters exhibit significant asymmetries in the orphan penumbral regions, typical of an uncombed filamentary structure. The orphan penumbrae lie above polarity inversion lines, where peculiar plasma motions take place with velocities larger than ±3 km s{sup –1}. The vector magnetic field in these regions is highly inclined, with the average magnetic field strength decreasing with time. The DOT observations in the Hα line and SDO Atmospheric Imaging Assembly measurements in the He II 30.4 nm line indicate that there is no counterpart for the orphan penumbrae at midchromospheric heights or above. Our findings suggest that in at least one of the features investigated the emerging flux may be trapped in the low atmospheric layers by the overlying pre-existing fields, forming these filamentary structures.

79 ASTRONOMY AND ASTROPHYSICS↗

BEAM STOP DESIGN METHODOLOGY AND DESCRIPTION OF A NEW SNS BEAM STOP

The design of accelerator components such as magnets, accelerator cavities and beam instruments tends to be a fairly standardized and collective effort within the particle accelerator community with well established performance, reliability and, in some cases, even budgetary criteria. Beam stop design, by contrast, has been comparatively subjective historically with much more general goals. This lack of rigor has lead to a variety of facility implementations with limited standardization and minimal consensus on approach to development within the particle accelerator community. At the Spallation Neutron Source (SNS), for example, there are four high power beam stops in use, three of which have significantly different design solutions. This paper describes the design of a new off-momentum beam stop for the SNS. The technical description of the system will be complemented by a discussion of design methodology. This paper presented an overview of the new SNS HEBT off-momentum beam stop and outlined a methodology for beam stop system design. The new beam stop consists of aluminium and steel blocks cooled by a closed-loop forced-air system and is expected to be commissioned this summer. The design methodology outlined in the paper represents a basic description of the process, data, analyses and critical decisions involved in the development of a beam stop system.

36 MATERIALS SCIENCE↗

Fiber-Optic Magnetic-Field-Strength Measurement System for Lightning Detection

A fiber-optic sensor system is designed to measure magnetic fields associated with a lightning stroke. Field vector magnitudes are detected and processed for multiple locations. Since physical limitations prevent the sensor elements from being located in close proximity to highly conductive materials such as aluminum, the copper wire sensor elements (3) are located inside a 4-cubic-in. (.66-cubic-cm) plastic housing sensor head and connected to a fiber-optic conversion module by shielded cabling, which is limited to the shortest length feasible. The signal path between the conversion module and the avionics unit which processes the signals are fiber optic, providing enhanced immunity from electromagnetic radiation incident in the vicinity of the measurements. The sensors are passive, lightweight, and much smaller than commercial B-dot sensors in the configuration which measures a three-dimensional magnetic field. The system is expandable, and provides a standard-format output signal for downstream processing. Inside of the sensor head, three small search coils, each having a few turns on a circular form, are mounted orthogonally inside the non-metallic housing. The fiber-optic conversion module comprises three interferometers, one for each search coil. Each interferometer has a high bandwidth optical phase modulator that impresses the signal received from its search coil onto its output. The output of each interferometer travels by fiber optic cable to the avionics unit, and the search coil signal is recovered by an optical phase demodulator. The output of each demodulator is fed to an analog-to-digital converter, whose sampling rate is determined by the maximum expected rate of rise and peak signal magnitude. The output of the digital processor is a faithful reproduction of the coil response to the incident magnetic field. This information is provided in a standard output format on a 50-ohm port that can be connected to any number of data collection and processing instruments and/or systems. The measurement of magnetic fields using fiber-optic signal processing is novel because it eliminates limitations of a traditional B-dot system. These limitations include the distance from the sensor to the measurement device, the potential for the signal to degrade or be corrupted by EMI from lightning, and the size and weight of the sensor and associated plate.

Gurecki, Jay↗

A simple and highly efficient protocol for 13 C-labeling of plant cell wall for structural and quantitative analyses via solid-state nuclear magnetic resonance

Plant cell walls are made of a complex network of interacting polymers that play a critical role in plant development and responses to environmental changes. Thus, improving plant biomass and fitness requires the elucidation of the structural organization of plant cell walls in their native environment. The 13 C-based multi-dimensional solid-state nuclear magnetic resonance (ssNMR) has been instrumental in revealing the structural information of plant cell walls through 2D and 3D correlation spectral analyses. However, the requirement of enriching plants with 13 C limits the applicability of this method. To our knowledge, there is only a very limited set of methods currently available that achieve high levels of 13 C-labeling of plant materials using 13 CO 2 , and most of them require large amounts of 13 CO 2 in larger growth chambers. In this study, a simplified protocol for 13C-labeling of plant materials is introduced that allows ca 60% labeling of the cell walls, as quantified by comparison with commercially labeled samples. This level of 13 C-enrichment is sufficient for all conventional 2D and 3D correlation ssNMR experiments for detailed analysis of plant cell wall structure. The protocol is based on a convenient and easy setup to supply both 13 C-labeled glucose and 13 CO 2 using a vacuum-desiccator. The protocol does not require large amounts of 13 CO 2 . This study shows that our 13 C-labeling of plant materials can make the accessibility to ssNMR technique easy and affordable. The derived high-resolution 2D and 3D correlation spectra are used to extract structural information of plant cell walls. This helps to better understand the influence of polysaccharide-polysaccharide interaction on plant performance and allows for a more precise parametrization of plant cell wall models.

09 BIOMASS FUELS↗

Electron-Ion Collider (EIC) Hadron Storage Ring (HSR) Injection Transport Beamline (Y-Line Ext.) Lattice Design and Magnet Parameters

The preliminary design of the Electron-Ion Collider (EIC) Hadron Storage Ring (HSR) Normal Conducting Injection Beamline ( Y-Line Ext. ) lattice is discussed. The preliminary design includes the periodic cells, matching sections, state of the art Twiss parameters at the HSR injection, the magnet parameters and first order instrumentation placement. Furthermore, the beamline parameters, element coordinates, and other information are discussed. The names of the HSR Injection Beamline elements used in this technical report ( i.e. HD1, HQ1 ) are preliminary and not the official site wide names.

43 PARTICLE ACCELERATORS↗

Physically Motivated Deep Learning to Superresolve and Cross Calibrate Solar Magnetograms

Abstract Superresolution (SR) aims to increase the resolution of images by recovering detail. Compared to standard interpolation, deep learning-based approaches learn features and their relationships to leverage prior knowledge of what low-resolution patterns look like in higher resolution. Deep neural networks can also perform image cross-calibration by learning the systematic properties of the target images. While SR for natural images aims to create perceptually convincing results, SR of scientific data requires careful quantitative evaluation. In this work, we demonstrate that deep learning can increase the resolution and calibrate solar imagers belonging to different instrumental generations. We convert solar magnetic field images taken by the Michelson Doppler Imager (resolution ∼2″ pixel −1 ; space based) and the Global Oscillation Network Group (resolution ∼2.″5 pixel −1 ; ground based) to the characteristics of the Helioseismic and Magnetic Imager (resolution ∼0.″5 pixel −1 ; space based). We also establish a set of performance measurements to benchmark deep-learning-based SR and calibration for scientific applications.

Muñoz-Jaramillo, Andrés (ORCID:0000000247160840)↗

Analysis of flutter in tape transport systems

Effect of flutter on digital data is recorded by magnetic tape recorders used with instrumentation systems. Major effect for both FM and direct recording techniques is shown to be a perturbation of the signal time base.

Davis, R. C.↗

Search for antimatter in primary cosmic rays.

Data from two flights of a new superconducting magnetic spectrometer are reported. This instrument was capable of a direct matter-antimatter separation in the cosmic rays. Antimatter events would appear in the spectrometer as trajectories which curve in the opposite direction to common matter, because of their negative charge. A brief description of the equipment and of the characteristics of the instrument is presented, along with the data processing techniques used. A new upper limit on the amount of antimatter in primary cosmic rays has been established. The limits are considerably lower than those for any previous experiment.

Buffington, A.↗

The Pioneer 11 high-field fluxgate magnetometer

The High Field Fluxgate Magnetometer Experiment flow aboard the Pioneer 11 spacecraft to investigate Jupiter's magnetic field is described. The instrument extends the spacecraft's upper limit measurement capability by more than an order of magnitude to 17.3 gauss with minimum power and volume requirements.

Acuna, M. H.↗

Optimization of multimagnetometer systems on a spacecraft

The problem of optimizing the position of magnetometers along a boom of given length to yield a minimized total error is investigated. The discussion is limited to at most four magnetometers, which seems to be a practical limit due to weight, power, and financial considerations. The outlined error analysis is applied to some illustrative cases. The optimal magnetometer locations, for which the total error is minimum, are computed for given boom length, instrument errors, and very conservative magnetic field models characteristic for spacecraft with only a restricted or ineffective magnetic cleanliness program. It is shown that the error contribution by the magnetometer inaccuracy is increased as the number of magnetometers is increased, whereas the spacecraft field uncertainty is diminished by an appreciably larger amount.

Neubauer, F. M.↗

Theoretical and Experimental Beam Plasma Physics (TEBPP)

The theoretical and experimental beam plasma physics (TEBPP) consists of a package of five instruments to measure electric and magnetic fields, plasma density and temperature, neutral density, photometric emissions, and energetic particle spectra during firings of the particle injector (SEPAC) electron beam. The package is deployed on a maneuverable boom (or RMS) and is used to measure beam characteristics and induced perturbations in the near field ( 10 m) and mid field (10 m to 100 m) along the electron beam. The TEBPP package will be designed to investigate induced oscillations and induced electromagnetic mode waves, neutral and ion density and temperature effects, and beam characteristics as a function of axial distance.

Roberts, W. T.↗

Plasma-depleted holes, waves, and energized particles from high-altitude explosive plasma perturbation experiments

The results of high-explosive shaped charge experiments King Crab and Bubble Machines I and II, intended to perturb the ambient plasma and magnetic field, are discussed. The instrumentation was flown above an altitude of 460 km in March 1980 and 1981 and comprised a single-axis dipole electric field detector, a fixed bias cylindrical Langmuir probe, a three-axis attitude magnetometer, and curved plated energetic ion and electron electrostatic analyzer. Among the effects of the explosion which are detailed, emphasis is placed on the creation of an ion-depleted dark hole during the Bubble Machine II experiment; mechanisms explaining the phenomenon are outlined. The auroral intensity ion beams with energies of up to 6.8 keV, observed following the explosion in the field-aligned ion electrostatic analyzer, are suggested to represent an existing ion conic population pitch angle scattered by the released barium into the view of the detector.

Wescott, E. M.↗