Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A Robust Magnetic Resonance Imager For Ground and Flight Based Measurements of Fluid Physics Phenomena

Nuclear magnetic resonance (NMR) is a powerful and versatile, noninvasive method for studying fluid transport problems, However, its applications to these types of investigations have been limited. A primary factor that limits the application of NMR has been the lack of a user-friendly, versatile, and inexpensive NMR imaging apparatus that can be used by scientists who are not familiar with sophisticated NMR. To rectify this situation, we developed a user-friendly, NMR imager for projects of relevance to the MRD science community. To that end, we performed preliminary collaborative experiments between NASA, NCMR, and New Mexico Resonance in the high field NMR set up at New Mexico Resonance to track wetting front dynamics in foams under gravity. The experiments were done in a 30 cm, 1.9T Oxford magnet with a TECMAG Libra spectrometer (Tecmag, Inc., Houston, TX). We used two different imaging strategies depending on whether the water in the foam sample was static or moving. Stationary water distributions were imaged with the standard Fourier imaging method, as used in medical MRI, in which data are acquired from all parts of the region of interest at all times and Fourier transformed into a static spatial image.

Source record↗

Magnetic resonance force microscopy with a paramagnetic probe

Here, we consider theoretically extension of magnetic resonance force microscopy (MRFM) replacing a ferromagnetic probe on a cantilever tip (CT) with a paramagnetic one (PMRFM). The dynamics of the interaction between the paramagnetic probe and a local magnetic moment in a sample is analyzed, using a quasi-classical approach. We show that the application of a proper sequence of electromagnetic pulses provides a significant deflection of the CT from the initial equilibrium position. Periodic application of these sequences of pulses results in quasi-periodic CT deflections from the equilibrium, which can be used for detection of the magnetic moment in a sample.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic resonance flow velocity and temperature mapping of a shape memory polymer foam device

Background: Interventional medical devices based on thermally responsive shape memory polymer (SMP) are under development to treat stroke victims. The goals of these catheterdelivered devices include re-establishing blood flow in occluded arteries and preventing aneurysm rupture. Because these devices alter the hemodynamics and dissipate thermal energy during the therapeutic procedure, a first step in the device development process is to investigate fluid velocity and temperature changes following device deployment. Methods: A laser-heated SMP foam device was deployed in a simplified in vitro vascular model. Magnetic resonance imaging (MRI) techniques were used to assess the fluid dynamics and thermal changes associated with device deployment. Results: Spatial maps of the steady-state fluid velocity and temperature change inside and outside the laser-heated SMP foam device were acquired. Conclusions: Though non-physiological conditions were used in this initial study, the utility of MRI in the development of a thermally-activated SMP foam device has been demonstrated.

42 ENGINEERING↗

Magnetic Resonance Imaging-Guided Osseous Biopsy in Children With Chronic Recurrent Multifocal Osteomyelitis

Purpose: To report the safety and diagnostic performance of magnetic resonance (MRI)-guided core biopsy of osseous lesions in children with chronic recurrent multifocal osteomyelitis (CRMO) that were visible on MRI but were occult on radiography and computed tomography (CT). Materials and Methods: A retrospective analysis of MRI-guided osseous biopsy performed in seven children (four girls and three boys; mean age 13 years (range 11 to 14) with CRMO was performed. Indication for using MRI guidance was visibility of lesions by MRI only. MRI-guided procedures were performed with 0.2-Tesla (Magnetom Concerto; Siemens, Erlangen, Germany; n = 5) or 1.5-T (Magnetom Espree; Siemens; n = 2) open MRI systems. Core needle biopsy was obtained using an MRI-compatible 4-mm drill system. Conscious sedation or general anesthesia was used. Parameters evaluated were lesion visibility, technical success, procedure time, complications and microbiology, cytology, and histopathology findings. Results: Seven of seven (100%) targeted lesions were successfully visualized and sampled. All obtained specimens were sufficient for histopathological analysis. Length of time of the procedures was 77 min (range 64 to 107). No complications occurred. Histopathology showed no evidence of malignancy, which was confirmed at mean follow-up of 50 months (range 28 to 78). Chronic nonspecific inflammation characteristic for CRMO was present in four of seven (58%) patients, and edema with no inflammatory cells was found in three of seven (42%) patients. There was no evidence of infection in any patient. Conclusion: MRI-guided osseous biopsy is a safe and accurate technique for the diagnosis of pediatric CRMO lesions that are visible on MRI only.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evidence for intrinsic impurities in the high-temperature superconductor Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+{delta}} from {sup 17}O nuclear magnetic resonance.

We have found that high quality crystals of Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+{delta}} (Bi-2212) have intrinsic magnetic defects that depend on oxygen doping. Our {sup 17}O nuclear magnetic resonance spectra provide evidence that local moments form in the CuO{sub 2} plane in both normal and superconducting states. We suggest that these magnetic impurities are related to the electronic disorder that scanning tunneling microscopy experiments identify with the oxygen dopant atoms.

36 MATERIALS SCIENCE↗

Long-lived frequency shifts observed in a magnetic resonance force microscope experiment following microwave irradiation of a nitroxide spin probe

We introduce a spin-modulation protocol for force-gradient detection of magnetic resonance that enables the real-time readout of longitudinal magnetization in an electron spin resonance experiment involving fast-relaxing spins. We applied this method to observe a prompt change in longitudinal magnetization following the microwave irradiation of a nitroxide-doped perdeuterated polystyrene film having an electron spin-lattice relaxation time of T{sub 1}{approx}1ms. The protocol allowed us to discover a large, long-lived cantilever frequency shift. Based on its magnitude, lifetime, and field dependence, we tentatively attribute this persistent signal to deuteron spin magnetization created via transfer of polarization from nitroxide spins.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of Prostate Magnetic Resonance Imaging/Ultrasound Fusion-guided Biopsy on Radiation Treatment Recommendations

Purpose: Targeted magnetic resonance imaging (MRI)/ultrasound fusion prostate biopsy (MRI-Bx) has recently been compared with the standard of care extended sextant ultrasound-guided prostate biopsy (SOC-Bx), with the former associated with an increased rate of detection of clinically significant prostate cancer. The present study sought to determine the influence of MRI-Bx on radiation therapy and androgen deprivation therapy (ADT) recommendations. Methods and Materials: All patients who had received radiation treatment and had undergone SOC-Bx and MRI-Bx at our institution were included. Using the clinical T stage, pretreatment prostate-specific antigen, and Gleason score, patients were categorized into National Comprehensive Cancer Network risk groups and radiation treatment or ADT recommendations assigned. Intensification of the recommended treatment after multiparametric MRI, SOC-Bx, and MRI-Bx was evaluated. Results: From January 2008 to January 2016, 73 patients received radiation therapy at our institution after undergoing a simultaneous SOC-Bx and MRI-Bx (n=47 with previous SOC-Bx). Repeat SOC-Bx and MRI-Bx resulted in frequent upgrading compared with previous SOC-Bx (Gleason score 7, 6.7% vs 44.6%; P<.001; Gleason score 8-10, 2.1% vs 38%; P<.001). MRI-Bx increased the proportion of patients classified as very high risk from 24.7% to 41.1% (P=.027). Compared with SOC-Bx alone, including the MRI-Bx findings resulted in a greater percentage of pathologically positive cores (mean 37% vs 44%). Incorporation of multiparametric MRI and MRI-Bx results increased the recommended use and duration of ADT (duration increased in 28 of 73 patients and ADT was added for 8 of 73 patients). Conclusions: In patients referred for radiation treatment, MRI-Bx resulted in an increase in the percentage of positive cores, Gleason score, and risk grouping. The benefit of treatment intensification in accordance with the MRI-Bx findings is unknown.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Zero-field nuclear magnetic resonance of chemically exchanging systems

Zero- to ultralow-field (ZULF) nuclear magnetic resonance (NMR) is an emerging tool for precision chemical analysis. In this work, we study dynamic processes and investigate the influence of chemical exchange on ZULF NMR J-spectra. We develop a computational approach that allows quantitative calculation of J-spectra in the presence of chemical exchange and apply it to study aqueous solutions of [ 15 N]ammonium ($^{15}NH^+_4$) as a model system. We show that pH-dependent chemical exchange substantially affects the J-spectra and, in some cases, can lead to degradation and complete disappearance of the spectral features. To demonstrate potential applications of ZULF NMR for chemistry and biomedicine, we show a ZULF NMR spectrum of [2- 13 C]pyruvic acid hyperpolarized via dissolution dynamic nuclear polarization (dDNP). We foresee applications of affordable and scalable ZULF NMR coupled with hyperpolarization to study chemical exchange phenomena in vivo and in situations where high-field NMR detection is not possible to implement.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of toroidal phasing of resonant magnetic perturbation effects on edge transport in the DIII-D tokamak

Resonant Magnetic Perturbation (RMP) fields produced by external control coils are considered a viable option for the suppression of Edge Localized Modes in present and future tokamaks. In DIII-D, the RMPs are generated by six pairs of I-coils, each spanning 60° in toroidal angle, with the currents flowing in opposite directions in adjacent pairs of I-coils. Reversal of the currents in all I-coils, which produces a 60° toroidal shift in the RMP field configuration, generates uniquely different edge pedestal profiles of the density, temperature, and rotation velocities, implying different effects on the related edge transport phenomena caused by the difference in toroidal phase of the I-coil currents. The diffusive and non-diffusive transport effects of this RMP toroidal phase reversal are analyzed by comparing the ion and electron heat diffusivities, angular momentum transport frequencies, ion diffusion coefficients, and the particle pinch velocities interpreted from the measured profiles for the two phases of the I-coil currents.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Understanding the effect of resonant magnetic perturbations on tearing mode dynamics

Numerical understandings of the effect of resonant magnetic perturbations (RMPs) on 2/1 tearing mode (TM) dynamics observed on J-TEXT tokamak (Hu et al. Nucl. Fusion 52, 083011 (2012)) are presented in this paper. The non-uniform mode rotation frequency, modulated by electromagnetic force (F{sub em}) and viscous force (F{sub vs}), results in the applied RMPs contributing both net stabilizing and braking effect on TM. Numerical evaluation based on analytical theory shows the applied RMP contributes a dominant stabilizing effect, which is responsible for the suppression of TM. The dynamics of the first discovered small locked island are investigated. It is found that the island is locked at the stabilizing phase and the saturated island width is less than the linear layer width. The simulated Mirnov signal indicates the small locked island is likely to be the complete suppression case observed in experiments. Associated with the application of RMP, the shape of Mirnov signal deviates from sinusoidal before mode locking, which is explained by numerical modeling. The comparisons between the numerical and experimental results are in good agreement phenomenally.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of resonant magnetic perturbations including toroidal sidebands on magnetic footprints and fast ion losses in HL-2M

Externally applied resonant magnetic perturbations (RMPs), generated by magnetic coils located outside the plasma (referred to as RMP coils), provide an effective way to control the edge localized mode (ELM) in tokamak devices. Due to the discrete nature of the toroidal distribution of these window-frame coils, toroidal sidebands always exist together with the fundamental harmonics designed for ELM control. In this work, the MARS-F code (Liu et al 2000 Phys. Plasmas7 3681) is applied to investigate the detailed features of the RMP spectra considering both the dominant harmonic (n = 2) and the associated sideband (n = 6), and the impact of the combined fields on magnetic footprints as well as on the fast ion losses for a reference double-null scenario in the HL-2M device. It is found that the sum of the n = 2 and n = 6 RMP fields splits the footprint and widens the footprint area, as compared to the single-n (n = 2) harmonic case. The resistive plasma response breaks the up–down symmetry of the footprint pattern on the outer divertor plates, which is otherwise symmetric assuming vacuum RMP fields. Considering fast ion losses, a threshold value exists for the initially launched radial position of test particles, as well as for the RMP coil current, before the loss occurs. When the threshold criterion is satisfied, the combined n = 2 and n = 6 RMP fields enhance the fast ion loss rate by , as compared to that of the n = 2 component alone. These results illustrate the important role of the sideband of RMP fields on the magnetic footprints and fast ion losses in tokamak plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Comparison of Recycling and Pumping Changes During Resonant Magnetic Perturbation Experiments at Low and High Collisionality in DIII-D

: Resonant magnetic perturbations (RMPs) have been shown to successfully suppress edge localized modes (ELMs) in the DIII-D tokamak. A previous study of target plate conditions highlighted differences in RMP discharges between low and high electron collisionality, nu(e)(sic), operation in DIII-D. This paper reports on a systematic study of the electron density pump-out associated with the turn-on of the RMP over a wide range of operating conditions in DIII-D, including shapes and collisionalities similar to those anticipated in ITER. It is shown that the pump-out magnitude, Delta n(e), has an upper envelope that is inversely proportional to the pedestal nu(e)(sic). The particle decay times, which are calculated based on global D(2) particle balances, show an increase as the pedestal nu(e)(sic) is increased. Both results are suggestive that the underlying physics mechanism is an increase in edge particle transport and/or that wall depletion is playing a role in the pump-out magnitude. (C) 2009 Elsevier B.V. All rights reserved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pedestal collapse by resonant magnetic perturbations

Pedestal collapse (i.e., the complete loss of the edge transport barrier (ETB)) in DIII-D H-mode plasmas occurs when resonant magnetic perturbations (RMPs) penetrate the steep gradient region at the plasma edge. Normally, RMP driven magnetic islands can occur at the top and bottom of the H-mode pedestal and these islands generate conditions consistent with edge-localized-mode (ELM) suppression and density pump-out, respectively, based on nonlinear two-fluid MHD simulations. In contrast, MHD simulations show that the steep pressure gradient region between the top and bottom of the DIII-D pedestal is generally immune to resonant field penetration due to large local E × B and diamagnetic flows. By this fortuitous circumstance, the edge-transport-barrier and H-mode confinement can be maintained while achieving ELM suppression. However, pedestal collapse can occur in DIII-D when the screening flows are inadequate to prevent field penetration in the steep gradient region of the pedestal. Non-linear two-fluid MHD simulations support the role of resonant field penetration in pedestal collapse for DIII-D H-mode plasmas with weak edge E × B and diamagnetic screening flows. ITER will likely have weaker edge screening flows than present experiments due to its much larger size, making it more susceptible to resonant field penetration in the steep gradient region of the pedestal. Analysis of model ITER equilibria demonstrates that resonant field penetration in the steep pressure gradient region is possible for RMP levels of the order required for ELM suppression. The effect of such penetration on the ITER pedestal will depend sensitively on the resulting degree of island overlap.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A laboratory study to estimate pore geometric parameters of sandstones using complex conductivity and nuclear magnetic resonance for permeability prediction

Here, we estimate parameters from the Katz and Thompson permeability model using laboratory complex electrical conductivity (CC) and nuclear magnetic resonance (NMR) data to build permeability models parameterized with geophysical measurements. We use the Katz and Thompson model based on the characteristic hydraulic length scale, determined from mercury injection capillary pressure estimates of pore throat size, and the intrinsic formation factor, determined from multisalinity conductivity measurements, for this purpose. Two new permeability models are tested, one based on CC data and another that incorporates CC and NMR data. From measurements made on forty-five sandstone cores collected from fifteen different formations, we evaluate how well the CC relaxation time and the NMR transverse relaxation times compare to the characteristic hydraulic length scale and how well the formation factor estimated from CC parameters compares to the intrinsic formation factor. We find: (1) the NMR transverse relaxation time models the characteristic hydraulic length scale more accurately than the CC relaxation time (R 2 of 0.69 and 0.33 and normalized root mean square errors (NRMSE) of 0.16 and 0.21, respectively); (2) the CC estimated formation factor is well correlated with the intrinsic formation factor (NRMSE50.23). We demonstrate that that permeability estimates from the joint-NMR-CC model (NRMSE50.13) compare favorably to estimates from the Katz and Thompson model (NRMSE50.074). Lastly, this model advances the capability of the Katz and Thompson model by employing parameters measureable in the field giving it the potential to more accurately estimate permeability using geophysical measurements than are currently possible.

36 MATERIALS SCIENCE↗

Reducing the Energy Consumption of Magnetic Resonance Imaging and Computed Tomography Scanners: Integrating Ecodesign and Sustainable Operations

This review aims to provide valuable insights into how energy consumption in magnetic resonance imaging (MRI) and computed tomography (CT) scanners can be effectively monitored, managed, and reduced, thereby contributing to more sustainable medical imaging practices. Demand for advanced imaging technologies such as MRI and CT scanners continues to increase, and understanding the resultant impact on greenhouse gas emissions requires a thorough evaluation of their energy consumption. Here, this review examines the energy monitoring and consumption characteristics of MRI and CT scanners, highlighting potential approaches for energy savings. An overview of MRI and CT principles, hardware components, and their associated energy consumption is provided. After addressing the technical aspects, the hardware and software requirements essential for accurate energy metering are detailed. Baseline measurements of energy consumption data are then provided as a foundation to understand current usage patterns and identify areas for improvement. Ongoing efforts to reduce energy consumption are categorized into 3 main strategies: operations, scanner design enhancements, and active scanning techniques, including accelerated MRI protocols. Ultimately, we emphasize that achieving sustainability in medical imaging requires collaboration across disciplines. By incorporating eco-friendly design in new imaging equipment, we can reduce the environmental impact, promote sustainability, and set a health care industry standard for a healthier planet.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optical magnetic resonances induced by the interference of reactive components in the near radiation-field zone of atoms in a glow discharge of a mixture of even neon isotopes

Four types of anomalous optical magnetic resonances shifted with respect to the zero magnetic field and with different shapes are found in radiation of a glow discharge in a mixture of even neon isotopes placed in a swept longitudinal magnetic field. This testifies to the manifestation of collective processes of synchronous light emission by oscillators belonging to isotopically different spatially separated atoms in discharge plasma. The origin of resonances is associated with nonstationary interference of reactive fields in the near radiation-field zones of emission of atoms, averaged over the lifetime of the fields (interference), while different types of resonances are associated with different methods of synchronization of the phases of the fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Identification of breast contour for nipple segmentation in breast magnetic resonance images

Purpose: The purpose of this study is to develop a method to simulate the breast contour and segment the nipple in breast magnetic resonance images. Methods: This study first identifies the chest wall and removes the chest part from the breast MR images. Subsequently, the cleavage and its motion artifacts are removed, distinguishing the separate breasts, where the edge points are sampled for curve fitting. Next, a region growing method is applied to find the potential nipple region. Finally, the potential nipple region above the simulated curve can be removed in order to retain the original smooth contour. Results: The simulation methods can achieve the least root mean square error (RMSE) for certain cases. The proposed YBnd and (Dmin+Dmax)/2 methods are significant due toP = 0.000. The breast contour curve detected by the two proposed methods is closer than that determined by the edge detection method. The (Dmin+Dmax)/2 method can achieve the lowest RMSE of 1.1029 on average, while the edge detection method results in the highest RMSE of 6.5655. This is only slighter better than the comparison methods, which implies that the performance of these methods depends upon the conditions of the cases themselves. Under this method, the maximal Dice coefficient is 0.881, and the centroid difference is 0.36 pixels. Conclusions: The contributions of this study are twofold. First, a method was proposed to identify and segment the nipple in breast MR images. Second, a curve-fitting method was used to simulate the breast contour, allowing the breast to retain its original smooth shape.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Volume Histogram Parameters and Local Tumor Control in Magnetic Resonance Image-Guided Cervical Cancer Brachytherapy

Purpose: To investigate the value of dose-volume histogram (DVH) parameters for predicting local control in magnetic resonance (MR) image-guided brachytherapy (IGBT) for patients with cervical cancer. Methods and Materials: Our study population consists of 141 patients with cervical cancer (Stages IB-IVA) treated with 45-50 Gy external beam radiotherapy plus four times 7 Gy IGBT with or without cisplatin. Gross tumor volume (GTV), high-risk clinical target volume (HRCTV), and intermediate-risk clinical target volume (IRCTV) were contoured, and DVH parameters (minimum dose delivered to 90% of the volume of interest [D90] and D100) were assessed. Doses were converted to the equivalent dose in 2 Gy (EQD2) by applying the linear quadratic model ({alpha}/{beta} = 10 Gy). Groups were defined for patients with or without local recurrence (LR) in the true pelvis for tumor size at diagnosis (GTV at diagnosis [GTVD] of 2-5 cm (Group 1) or greater than 5 cm (Group 2) and for tumor size response at IGBT (HRCTV) of 2-5 cm (Group 2a) or greater than 5 cm (Group 2b). Results: Eighteen LRs were observed. The most important DVH parameters correlated with LR were the D90 and D100 for HRCTV. Mean D90 and D100 values for HRCTV were 86 {+-} 16 and 65 {+-} 10 Gy, respectively. The D90 for HRCTV greater than 87 Gy resulted in an LR incidence of 4% (3 of 68) compared with 20% (15 of 73) for D90 less than 87 Gy. The effect was most pronounced in the tumor group (Group 2b). Conclusions: We showed an increase in local control in IGBT in patients with cervical cancer with the dose delivered, which can be expressed by the D90 and D100 for HRCTV. Local control rates greater than 95% can be achieved if the D90 (EQD2) for HRCTV is 87 Gy or greater.

62 RADIOLOGY AND NUCLEAR MEDICINE↗