Search NASA⌕ Search

SEARCH · Search NASA

Results for “Materials Test Module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗

Robust Measurement of Thin-Film Photovoltaic Modules Exhibiting Light-Induced Transients: Preprint

Light-induced changes to the current-voltage characteristic of thin-film photovoltaic modules (i.e. light-soaking effects) frustrate the repeatable measurement of their operating power. We describe best practices for mitigating, or stabilizing, light-soaking effects for both CdTe and CIGS modules to enable robust, repeatable, and relevant power measurements. We motivate the practices by detailing how modules react to changes in different stabilization methods. We also describe and demonstrate a method for validating alternative stabilization procedures, such as those relying on forward bias in the dark. Reliable measurements of module power are critical for qualification testing, reliability testing, and power rating.

14 SOLAR ENERGY↗

Vibro-acoustic modulation and data fusion for localizing alkali–silica reaction–induced damage in concrete

This article investigates the application of vibro-acoustic modulation testing for diagnosing damage in concrete structures. The vibro-acoustic modulation technique employs two excitation frequencies on a structure. The interaction of these excitations in the measured response indicates damage through the presence of sidebands in the frequency spectra. Past studies using this technique have mostly focused on metals and composites (thin plates or laminates). Our research focuses on concrete, which is a highly heterogeneous material susceptible to a variety of chemical, physical, and mechanical damage processes. In particular, this article investigates diagnosing cracking in concrete from an expansive gel produced by an alkali–silica reaction in the presence of moisture. Past studies have been limited to damage detection using vibro-acoustic modulation testing, whereas this article extends the technique to damage localization. A cement slab with pockets of reactive aggregate is used to investigate the diagnosis technique. The effects of different testing parameters, such as locations, magnitudes, and frequencies of the two excitations, are analyzed and incorporated in the damage localization methodology. A Bayesian probabilistic methodology is developed to fuse the information from multiple test configurations in order to construct damage probability maps for the test specimen. The results of vibro-acoustic modulation–based damage localization are validated by petrographic study of cores taken from the slab.

Karve, Pranav↗

High Voltage Solar Concentrator Experiment with Implications for Future Space Missions

This paper describes the design, development, fabrication, and test of a high performance, high voltage solar concentrator array. This assembly is believed to be the first ever terrestrial triple-junction-cell solar array rated at over 1 kW. The concentrator provides over 200 W/square meter power output at a nominal 600 Vdc while operating under terrestrial sunlight. Space-quality materials and fabrication techniques were used for the array, and the 3005 meter elevation installation below the Tropic of Cancer allowed testing as close as possible to space deployment without an actual launch. The array includes two concentrator modules, each with a 3 square meter aperture area. Each concentrator module uses a linear Fresnel lens to focus sunlight onto a photovoltaic receiver that uses 240 series-connected triple-junction solar cells. Operation of the two receivers in series can provide 1200 Vdc which would be adequate for the 'direct drive' of some ion engines or microwave transmitters in space. Lens aperture width is 84 cm and the cell active width is 3.2 cm, corresponding to a geometric concentration ratio of 26X. The evaluation includes the concentrator modules, the solar cells, and the materials and techniques used to attach the solar cells to the receiver heat sink. For terrestrial applications, a finned aluminum extrusion was used for the heat sink for the solar cells, maintaining a low cell temperature so that solar cell efficiency remains high.

Mehdi, Ishaque S.↗

Evaluation and modeling of the potential effects of a module manufacturing anomaly

Photovoltaic lifetime predictions are in great demand, but are exceedingly difficult to achieve with uncertainties small enough to be useful. During the construction of photovoltaic modules, small unplanned variability in materials or processes can have profound effects on module durability. Thus, continual monitoring of production quality is needed. In the subject production run, module quality, as monitored by damp heat testing, revealed a subset of modules that were prone to higher degradation rates. An assessment of the potential long-term power loss and mitigation strategies was needed. To do this, modules were exposed to variable levels of humidity and temperature with periodic monitoring. The analysis takes into account the kinetics of the degradation and the spatially and temporally varying humidity content within the module during accelerated stress testing. This is an important aspect for extrapolating laboratory results to field exposure because moisture ingress is diffusion limited in most laboratory module tests but not limited in these fielded modules. This analysis predicted that although a solder flux induce degradation mechanism is significant in accelerated stress test, this is probably an artifact of a process with a very large acceleration factor that is not likely to be significant for deployed modules. The degradation mechanism affected a limited area around the tabbing helping to minimize the effect. Furthermore, three years after the system was commissioned, the fielded modules indeed show no significant power loss.

14 SOLAR ENERGY↗

Multicenter Collaborative Quality Assurance Program for the Province of Ontario, Canada: First-Year Results

Purpose: The objective of this work was to develop a collaborative quality assurance (CQA) program to assess the performance of intensity modulated radiation therapy (IMRT) planning and delivery across the province of Ontario, Canada. Methods and Materials: The CQA program was designed to be a comprehensive end-to-end test that can be completed on multiple planning and delivery platforms. The first year of the program included a head-and-neck (H and N) planning exercise and on-site visit to acquire dosimetric measurements to assess planning and delivery performance. A single dosimeter was used at each institution, and the planned to measured dose agreement was evaluated for both the H and N plan and a standard plan (linear-accelerator specific) that was created to enable a direct comparison between centers with similar infrastructure. Results: CQA program feasibility was demonstrated through participation of all 13 radiation therapy centers in the province. Planning and delivery was completed on a variety of infrastructure (treatment planning systems and linear accelerators). The planning exercise was completed using both static gantry and rotational IMRT, and planned-to-delivered dose agreement (pass rates) for 3%/3-mm gamma evaluation were greater than 90% (92.6%-99.6%). Conclusions: All centers had acceptable results, but variation in planned to delivered dose agreement for the same planning and delivery platform was noted. The upper end of the range will provide an achievable target for other centers through continued quality improvement, aided by feedback provided by the program through the use of standard plans and simple test fields.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization and Analysis of Insulated Metal Substrate-Based SiC Power Module for Traction Application

This paper presents the electrical characterization and drive cycle--based thermal analysis of an insulated metal substrate (IMS)--based silicon carbide power module for high-power traction inverters. The substrate was constructed using a thin layer of polymer--ceramic blend dielectric material with a thick copper core to improve transient thermal performance. The cooling performance of this module has already been validated with promising results. In this paper, an experimental test bed was set up to evaluate the dynamic and static electrical performance of the designed module under a wide range of operating conditions. The characterization results were then used to develop a drive cycle--based thermal model to validate the performance compared to the traditional direct bonded copper--based power module. The results indicate that the IMS-based power module is a suitable solution for high-power traction applications.

Chowdhury, Shajjad↗

Element material experiment by EFFU

National Space Development Agency of JAPAN (NASDA) is planning to perform Element Material Exposure Experiment using Exposed Facility Flyer Unit (EFFU). Several materials which will be used on JEM (Japanese Experiment Module for the space station) will be exposed. Space environment monitoring is also planned in this experiment. Several ground based tests are now being performed and getting useful data.

Hashimoto, Yoshihiro↗

Suggested Modifications for Bifacial Capacity Testing: Preprint

Capacity tests such as those described in ASTM 2848 and IEC 61724-2 are widely used during the contracting and acceptance testing of PV systems. With the increasing deployment of bifacial PV modules, there is a need to develop a standardized approach to capacity test these systems. Although variability and bias error was inherently higher for the measured capacity of bifacial systems, it could be reduced to a level consistent with the monofacial reference system by appropriate incorporation of rear irradiance- either measured or modeled. Three field installations provided bifacial system capacity that was measured with a mean bias error and standard deviation within 1% over the 2-10 month observation period. Capacity test accuracy could be improved further by utilizing measured back-of-module temperature and the IEC 61724-2 test method.

14 SOLAR ENERGY↗

Quantifying Optical Loss of High-Voltage Degradation Modes in PV Modules Using Spectral Analysis [Slides]

The direct current bias for photovoltaic (PV) modules interconnected in series-strings may include both high voltage negative ("HV-") and positive ("HV+") polarity with respect to the electrical ground. Multiple degradation modes, resulting in quantifiable optical loss, were found to occur during HV-/HV+ sequential stress, including: corrosion of the external glass surface, encapsulant delamination (at its interfaces with the glass and the PV cell), internal haze formation (resulting from a chemical interaction between the glass and the encapsulant), corrosion and migration of the gridlines, and corrosion of the silicon nitride (SixNy) antireflective coating on the cell. The effects of these separate modes were examined using monolithic (e.g., glass or PV cell) and laminated-coupon (glass/encapsulant/glass or glass/encapsulant/cell/encapsulant/backsheet) specimens. Characterizations during and after unbiased accelerated testing at 85 degrees C/85% relative humidity included: spectrophotometry, optical microscopy, electron microscopy, and ellipsometry. For some module components (i.e., the glass and the SixNy coating), the optical performance was determined through iterative analysis of empirical measurements. Concentrating on just their spectral effect, a novel model was then developed to estimate the transfer of light to the PV cell and the return of light from the PV module with simultaneous degradation mechanisms, which was compared to a mini-module previously subjected to HV-/HV+ stress. The model suggests one-third of the current loss observed for the mini-module can be attributed to the optical degradation of the packaging materials. The dominant degradation modes include encapsulant delamination and corrosion of the SixNy coating. Recommendations are given so that the optical model may be improved relative to accelerated testing and validated relative to field aging.

14 SOLAR ENERGY↗

Use of indentation to study the degradation of photovoltaic backsheets

The ability of electrical insulating materials within a module to act as insulators is a key safety requirement for photovoltaic (PV) technology. Presently, however, the durability of backsheets may not be readily assessed. For example, the mechanical tensile test continues to be developed, and its use has not been validated such that a technically based pass/fail criteria may be established. This study examines the use of simple indentation methods, including durometer hardness and instrumented indentation, as a means to quantitively assess the degradation of PV backsheets. Characteristics including: hardness, modulus, load/displacement profile, creep hold response, and residual impression are explored in an empirical study. Glass/encapsulant/backsheet mini-modules constructed using backsheets including: polyamide (PA), poly(ethylene terephthalate) (PET), polyvinyl fluoride (PVF) laminate ('TPE'), and polyvinylidene fluoride (PVDF) were examined. An M-type durometer as well as Berkovich and cube-corner tips were used in the indentation experiments. Additional characterizations were performed to interpret the indentation measurements including: surface roughness measurements using atomic force microscopy (AFM), a chemical integrity study using Fourier-transform infrared spectroscopy (FTIR), and phase-transition measurements using differential scanning calorimetry (DSC). The results are analyzed in the context of the combined accelerated stress test (C-AST) also explored in this study. Instrumented indentation (i.e., using a Berkovich tip) was able to distinguish between backsheets and quantify the effects of accelerated testing (including up to 60%, 25%, and 20% change in hardness, modulus, and creep displacement, respectively). The embrittlement of the backsheets was not readily assessable using cube-corner indentation. Cracking of the known-bad polyamide backsheet was observed from the C-AST, which was not observed to result from steady state UV weathering.

14 SOLAR ENERGY↗

Magnetic field dependence of singlet fission in solutions of diphenyl tetracene

Magnetic field effects provide a convenient and specific probe of singlet exciton fission within optoelectronic devices. Here, we demonstrate that this tool may also be applied to screen potential fission material candidates in solution. We characterize the phenomenon in diphenyl tetracene (DPT), which shows strong fluorescence modulation and the expected field dependence in its transient decay as a function of concentration. Furthermore, solution measurements may also be used to test for the presence of an intermediate charge transfer state, but we observe no changes to the field dependence of DPT singlet exciton fission in toluene relative to chloroform.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis Of Ductile Crack Growth In Pipe Test In STYLE Project

The Oak Ridge National Laboratory (ORNL) is conducting structural analyses, both deterministic and probabilistic, to simulate a large scale mock-up experiment planned within the European Network for Structural Integrity for Lifetime Management non-RPV Components (STYLE). The paper summarizes current ORNL analyses of STYLE s Mock-up3 experiment to simulate/evaluate ductile crack growth in a cladded ferritic pipe. Deterministic analyses of the large-scale bending test of ferritic surge pipe, with an internal circumferential crack, are simulated with a number of local micromechanical approaches, such as Gurson-Tvergaard-Needleman (GTN) model and cohesive-zone model. Both WARP 3D and ABAQUS general purpose finite element programs are being used to predict the failure load and the failure mode, i.e. ductile tearing or net-section collapse, as part of the pre-test phase of the project. Companion probabilistic analyses of the experiment are utilizing the ORNL developed open-source Structural Integrity Assessment Modular - Probabilistic Fracture Mechanics (SIAM-PFM) framework. SIAM-PFM contains engineering assessment methodology such as the tearing instability (J-T analysis) module developed for inner surface cracks under bending load. The driving force J-integral estimations are based on the SC.ENG1 or SC.ENG2 models. The J-A2 methodology is used to transfer (constraint-adjust) J-R curve material data from standard test specimens to the Mock-up3 experiment configuration. The probabilistic results of the Mock-Up3 experiment obtained from SIAM-PFM will be compared to those generated using the deterministic finite element modeling approach. The objective of the probabilistic analysis is to provide uncertainty bounds that will assist in assessing the more detailed 3D finite-element solutions and to also assess the level of confidence that can be placed in the best-estimate finite-element solutions.

99 GENERAL AND MISCELLANEOUS↗

Artificial ground reflector size and position effects on energy yield and economics of single‐axis‐tracked bifacial photovoltaics

Abstract Artificial ground reflectors improve bifacial energy yield by increasing both front and rear‐incident irradiance. Studies have demonstrated an increase in energy yield due to the addition of artificial reflectors; however, they have not addressed the effect of varying reflector dimensions and placement on system performance and the impact of these parameters on the reflectors' financial viability. We studied the effect of high albedo (70% reflective) artificial reflectors on single‐axis‐tracked bifacial photovoltaic systems through ray‐trace modeling and field measurements. In the field, we tested a range of reflector configurations by varying reflector size and placement and demonstrated that reflectors increased daily energy yield up to 6.2% relative to natural albedo for PERC modules. To confirm the accuracy of our model, we compared modeled and measured power and found a root mean square error (RMSE) of 5.4% on an hourly basis. We modeled a typical meteorological year in Golden, Colorado, to demonstrate the effects of artificial reflectors under a wide range of operating conditions. Seventy percent reflective material can increase total incident irradiance by 1.9%–8.6% and total energy yield by 0.9%–4.5% annually after clipping is considered with a DC–AC ratio of 1.2. Clipping has a significant effect on reflector impact and must be included when assessing reflector viability because it reduces reflector energy gain. We calculated a maximum viable cost for these improvements of up to $2.50–4.60/m 2 , including both material and installation, in Golden. We expanded our analysis to cover a latitude range of 32–48°N and demonstrated that higher‐latitude installations with lower energy yield and higher diffuse irradiance content can support higher reflector costs. In both modeling and field tests, and for all locations, the ideal placement of the reflectors was found to be directly underneath the module due to the optimized rear irradiance increase.

14 SOLAR ENERGY↗

Active heat exchange system development for latent heat thermal energy storage

Five tasks to select, design, fabricate, test and evaluate candidate active heat exchanger modules for future applications to solar and conventional utility power plants were discussed. Alternative mechanizations of active heat exchange concepts were analyzed for use with heat of fusion phase change materials (PCMs) in the temperature range of 250 to 350 C. Twenty-six heat exchange concepts were reviewed, and eight were selected for detailed assessment. Two candidates were selected for small-scale experimentation: a coated tube and shell heat exchanger and a direct contact reflux boiler. A dilute eutectic mixture of sodium nitrate and sodium hydroxide was selected as the PCM from over 50 candidate inorganic salt mixtures. Based on a salt screening process, eight major component salts were selected initially for further evaluation. The most attractive major components in the temperature range of 250 to 350 C appeared to be NaNO3, NaNO2, and NaOH. Sketches of the two active heat exchange concepts selected for test are given.

Lefrois, R. T.↗

Development and Impact Evaluation of an E-Learning Radiation Oncology Module

Purpose: Radiation oncologists are faced with the challenge of irradiating tumors to a curative dose while limiting toxicity to healthy surrounding tissues. This can be achieved only with superior knowledge of radiologic anatomy and treatment planning. Educational resources designed to meet these specific needs are lacking. A web-based interactive module designed to improve residents' knowledge and application of key anatomy concepts pertinent to radiotherapy treatment planning was developed, and its effectiveness was assessed. Methods and Materials: The module, based on gynecologic malignancies, was developed in collaboration with a multidisciplinary team of subject matter experts. Subsequently, a multi-centre randomized controlled study was conducted to test the module's effectiveness. Thirty-six radiation oncology residents participated in the study; 1920 were granted access to the module (intervention group), and 17 in the control group relied on traditional methods to acquire their knowledge. Pretests and posttests were administered to all participants. Statistical analysis was carried out using paired t test, analysis of variance, and post hoc tests. Results: The randomized control study revealed that the intervention group's pretest and posttest mean scores were 35% and 52%, respectively, and those of the control group were 37% and 42%, respectively. The mean improvement in test scores was 17% (p < 0.05) for the intervention group and 5% (p = not significant) for the control group. Retrospective pretest and posttest surveys showed a statistically significant change on all measured module objectives. Conclusions: The use of an interactive e-learning teaching module for radiation oncology is an effective method to improve the radiologic anatomy knowledge and treatment planning skills of radiation oncology residents.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermal and other tests of photovoltaic modules performed in natural sunlight

The bulk of the testing was the characterization of twenty-nine modules according to their nominal operating cell temperature (NOCT) and the effect on NOCT of changes in module design, various residential roof mounting configurations, and dirt accumulation. Other tests, often performed parallel with the NOCT measurements, evaluated the improvement in electrical performance by cooling the modules with water and by channeling the waste heat into a phase change material (wax). Electrical degradation resulting from the natural marriage of photovoltaic and solar water heating modules was also demonstrated. Cost effectiveness of each of these techniques are evaluated in light of the LSA cost goal of $0.50 per watt.

Stultz, J. W.↗