Search NASA⌕ Search

SEARCH · Search NASA

Results for “Materials Test Module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

BF 3 -promoted electrochemical properties of quinoxaline in propylene carbonate

Electrochemical and density functional studies demonstrate that coordination of electrolyte constituents to quinoxalines modulates their electrochemical properties. Quinoxalines are shown to be electrochemically inactive in most electrolytes in propylene carbonate, yet the predicted reduction potential is shown to match computational estimates in acetonitrile. We find that in the presence of LiBF 4 and trace water, an adduct is formed between quinoxaline and the Lewis acid BF3, which then displays electrochemical activity at 1–1.5 V higher than prior observations of quinoxaline electrochemistry in non-aqueous media. Direct synthesis and testing of a bis-BF 3 quinoxaline complex further validates the assignment of the electrochemically active species, presenting up to a ~26-fold improvement in charging capacity, demonstrating the advantages of this adduct over unmodified quinoxaline in LiBF 4 -based electrolyte. The use of Lewis acids to effectively “turn on” the electrochemical activity of organic molecules may lead to the development of new active material classes for energy storage applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum Anomalies in Condensed Matter

Quantum materials provide a fertile ground in which to test and realize unusual phenomena such as quantum anomalies predicted by quantum field theory. There are three important symmetries that are broken when classical field theory is moved into the quantum regime, the scale anomaly, the axial (chiral) anomaly, and the parity anomaly. Several potential device applications may be realized by the discovery of quantum anomalies in condensed matter, enabled by the new physics they embody, including ultra‐sensitive dark matter detectors, far infrared optical modulators, micro‐bolometric detectors, low‐dissipation ballistic transporters, terahertz‐based qubits, terahertz polarization state controls, passive magnetic field sensors, stable topological superconductors that host Majorana fermions, and qubits topologically protected against decoherence. In this perspective article, the definition of these quantum anomalies is laid out, how little is known in the context of condensed matter, and how quantum anomalies are predicted to manifest as anomalous electronic, thermal, and magnetic behavior in experiments on topological quantum materials, including Weyl and Dirac semimetals. Furthermore, the importance that mechanical strain and defects will play in modifying signatures of quantum anomalies is discussed.

36 MATERIALS SCIENCE↗

Updated sustainability status of cadmium telluride thin‐film photovoltaic systems and projections

This paper provides a comprehensive assessment of the up-to-date life-cycle sustainability status of cadmium-telluride based photovoltaic (PV) systems. Current production modules (Series 6 and Series 7) are analyzed in terms of their energy performance and environmental footprint and compared with the older series 4 module production and current single-crystalline Silicon (sc-Si) module production. For fixed-tilt systems with Series 6 modules operating under average US irradiation of 1800 kWh/m 2 /year, the global warming potential (GWP) is reduced from 16 g CO 2eq /kWh in Series 4 systems to 10 CO 2 eq /kWh in Series 6 systems. For operation in US-SW irradiation of 2300 kWh/m 2 /year, the GWP is reduced from 11 to 8 CO 2eq /kWh and for 1-axis tracking systems operating in Phoenix, Arizona, with point-of array irradiation of 3051 kWh/m 2 /year the GWP is reduced to 6.5 CO 2eq /kWh. Similar reductions have happened in all environmental indicators. Energy payback times (EPBT) of currently installed systems range from 0.6 years for fixed–tilt ground–mounted installations at average US irradiation at latitude tilt installations to 0.3 years for one-axis trackers at high US-SW irradiation, considering average fossil-fuel dominated electricity grids with fuel to electricity conversion efficiency of 0.3. The resulting energy return on energy investment (EROI) also depends on the conversion efficiency of the electricity grid and on the operation life expectance. For a 30-year operational life and grid conversion efficiency of 0.3, EROI ranges from 50 (at US average irradiation) to 70 for US-SW irradiation. The EROI declines with increased grid conversion efficiency; for CdTe PV operating in south California with grid conversion efficiency of 49%, the EROI is about 50 and is projected to fall to 30 when the state's 2030 target of 80% renewable energy penetration materializes. Material alternatives that show a potential of further reductions in degradation rates and materials for enhanced encapsulation that would enable longer operation lives have also been investigated. A degradation rate of 0.3%/year, which has been verified by accelerated testing, is assumed in 30-year scenarios; this is projected to be reduced to 0.2%/year in the near-term and potentially to 0.1%/year in the longer term. With such low degradation rates and enhanced edge-sealing, modules can last 40- to 50-years. Consequently, all impact indicators will be proportionally reduced while EROI will increase. This detailed LCA was conducted according to ISO standards and IEA PVPS Task 12 guidelines. Furthermore, the study revealed that the choices of system models, methods and temporal system boundaries can significantly impact the results and points out to the need to include assumptions regarding these choices in the “transparency in reporting” requirements listed in the IEA PVPS Task 12 Guidelines.

14 SOLAR ENERGY↗

Studies on the Module Structure for the NOvA Liquid Scintillator Neutrino Detector

This thesis contains studies pertinent to the construction of modules for the NOνAexperiment detectors. The tensile strength of acrylic and epoxy adhesives used in construction of the detector was studied over time and with various surface preparations. Sanding and corona discharge surface treatments increased the bond strength of the acrylic by 10-20%; aging in oil did not affect the acrylic bond strength while aging in air at 50°C for 9 months (equivalent to approximately 5 years at room temperature) increased the acrylic bond strength by 25%. For the epoxy, corona discharge treated samples’ strength increased slightly after aging while the strength of sanded samples in air remained consistent and sanded samples in oil decreased by 17% when aged at 50°C for 1.5 years (equivalent to approximately 10 years at room temperature).All materials used in the detector were studied to determine if degrading interaction would occur with the pseudocumene liquid scintillator. Substances such as acrylic adhesive and PTFE paste were found to interact with the scintillator while materials such as a variety of PVCs, epoxy adhesives, and PTFE tape were found to be non-reactive with the scintillator. Following the appearance of cracks on manifold covers in installed modules, studies were carried out to help to determine the cause and mitigation of these cracks. Manifold covers that had been pressure tested at various pressures during the check of the seals during the manufacturing process were examined for the formation of cracks. “Containment units” were used to constrain the swelling of the manifold covers during pressure testing. Internal cracks were visible on the majority of manifold covers tested at 1.4 bar with the original containment units. It was found that reducing the pressure testing of the modules from 1.4 bar to 0.7 bar and increasing the rigidity of the pressure test containment units eliminated the formation of visible cracks in the manifold covers. Stress concentration in small fillet radius injection molded PVC was studied. GeonM3500 PVC has a yield strength 12% greater than Geon M3800 PVC originally used for the manifold covers but increased the stress concentrated failure time by 6600% and was thus chosen to mold new manifold covers after a redesign to eliminate stress concentrating features.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of Combined and Sequential Accelerated Stress Testing for Derisking Photovoltaic Modules

This talk reviews sequential and combined accelerated stress tests of the past decade that have been shown to better replicate degradation mechanisms seen in the field, that single-factor steady-state tests have failed to reproduce. When designing stress tests for PV modules, it is shown, with examples, how it is beneficial to consider representation of the shipping module, the stress factors applied, and how the stress factors are sequenced or combined in the natural environment. Finally, current and future efforts to realize accelerated stress tests based on these concepts are discussed.

14 SOLAR ENERGY↗

Evaluating Swallowing Muscles Essential for Hyolaryngeal Elevation by Using Muscle Functional Magnetic Resonance Imaging

Purpose: Reduced hyolaryngeal elevation, a critical event in swallowing, is associated with radiation therapy. Two muscle groups that suspend the hyoid, larynx, and pharynx have been proposed to elevate the hyolaryngeal complex: the suprahyoid and longitudinal pharyngeal muscles. Thought to assist both groups is the thyrohyoid, a muscle intrinsic to the hyolaryngeal complex. Intensity modulated radiation therapy guidelines designed to preserve structures important to swallowing currently exclude the suprahyoid and thyrohyoid muscles. This study used muscle functional magnetic resonance imaging (mfMRI) in normal healthy adults to determine whether both muscle groups are active in swallowing and to test therapeutic exercises thought to be specific to hyolaryngeal elevation. Methods and Materials: mfMRI data were acquired from 11 healthy subjects before and after normal swallowing and after swallowing exercise regimens (the Mendelsohn maneuver and effortful pitch glide). Whole-muscle transverse relaxation time (T2 signal, measured in milliseconds) profiles of 7 test muscles were used to evaluate the physiologic response of each muscle to each condition. Changes in effect size (using the Cohen d measure) of whole-muscle T2 profiles were used to determine which muscles underlie swallowing and swallowing exercises. Results: Post-swallowing effect size changes (where a d value of >0.20 indicates significant activity during swallowing) for the T2 signal profile of the thyrohyoid was a d value of 0.09; a d value of 0.40 for the mylohyoid, 0.80 for the geniohyoid, 0.04 for the anterior digastric, and 0.25 for the posterior digastric-stylohyoid in the suprahyoid muscle group; and d values of 0.47 for the palatopharyngeus and 0.28 for the stylopharyngeus muscles in the longitudinal pharyngeal muscle group. The Mendelsohn maneuver and effortful pitch glide swallowing exercises showed significant effect size changes for all muscles tested, except for the thyrohyoid. Conclusions: Muscles of both the suprahyoid and the longitudinal pharyngeal muscle groups are active in swallowing, and both swallowing exercises effectively target muscles elevating the hyolaryngeal complex. mfMRI is useful in testing swallowing muscle function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Separation and Enrichment of Xenon in Air (SBIR Phase II Final Report)

High-performance composite membranes and high-performance spiral-wound modules have been successfully developed that can be used to detect the concentration of xenon present in the atmosphere. The selective membrane material is Hyflon® AD 60, a perfluorinated polymer available from Solvay. The material has a nitrogen/xenon selectivity of at least five. The membranes were incorporated into spiral-wound modules that have special baffles in the feed channels. The baffles increase gas velocity and allow the module to be operated at stage cuts of 90% or higher, while maintaining their separation efficiency. A prototype system was constructed and tested at MTR. The system was subsequently shipped to the Savannah River National Laboratory where it was operated with local atmospheric air. The results obtained by MTR and Savannah River are equivalent and show that the system is capable of concentrating xenon by a factor of 35 at a xenon recovery of 50%.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A distillation column for hydrogen isotope removal from liquid lithium

Recovery of tritium from plasma-facing components in fusion devices will be vital to future full-scale operation. Liquid, low-Z materials have demonstrated many inherent advantages over solid first wall materials. To this end, a thermal treatment method in the form of a distillation column for extraction of hydrogen isotopes from liquid lithium has been designed, developed, and constructed at the Center for Plasma-Material Interactions at the University of Illinois at Urbana-Champaign. Use of induction heating and lithium condensation stages are the two qualities that set this design apart from other thermal treatment systems. Induction heating capabilities were modeled using the COMSOL Multiphysics software, which were validated when commissioning the physical heater module. Proof-of-concept tests were performed in the prototype column, which were undertaken as batch processes to investigate the efficacy with which the column could remove hydrogen gas from lithium-rich and lithium hydride-rich samples. All of the tests reported used lithium hydride as a surrogate for lithium deuteride and lithium tritide. The design process and results from the initial tests will be discussed, along with the envisioned placement of this treatment scheme in a fully-functional lithium loop.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Testing of the Authenticatable Container Tracking System (ACTS)

The Authenticatable Container Tracking System (ACTS) is being designed to provide a secure container tag that can be used to optimize chain-of-custody monitoring for packaged nuclear materials as they are being stored, processed, and transported. ACTS is an active device that uses an almost-universal core platform that can be appropriately configured to provide the necessary data acquisition, data logging, and communications functions needed for 21st century material accountancy, monitoring, and tracking applications. The core design supports active monitoring of containment, movement, and location and provides secure data transmission via selectable communication methods that can be used throughout the world. This core architecture enables appropriately designed modules to be easily interfaced to the basic system, thus providing an integration path for current and new technologies. ACTS contains a built-in set of sensors but also supports an expansion bus for up to six additional communications, tracking, or sensing modules that may enhance monitoring and tracking of particular containers for specific applications. ACTS stores events in memory, communicates activity to Argonne National Laboratory’s ARG-US TransPort tracking and information server, and provides options for data encryption and authentication. We are currently beginning a testing phase that will field five devices outdoors in a controlled environment to allow evaluation of the functionality of the systems and the hardness of the devices to outdoor conditions. Partners for this system are Oak Ridge National Laboratory, Argonne National Laboratory, Savannah River National Laboratory, Pacific Northwest National Laboratory, and commercialization partner The Aquila Group.

Britton Jr, Chuck↗

Initial Report of Pencil Beam Scanning Proton Therapy for Posthysterectomy Patients With Gynecologic Cancer

Purpose: To report the acute toxicities associated with pencil beam scanning proton beam radiation therapy (PBS) for whole pelvis radiation therapy in women with gynecologic cancers and the results of a dosimetric comparison of PBS versus intensity modulated radiation therapy (IMRT) plans. Methods and Materials: Eleven patients with posthysterectomy gynecologic cancer received PBS to the whole pelvis. The patients received a dose of 45 to 50.4 Gy relative biological effectiveness (RBE) in 1.8 Gy (RBE) daily fractions. Acute toxicity was scored according to the Common Terminology Criteria for Adverse Events, version 4. A dosimetric comparison between a 2-field posterior oblique beam PBS and an IMRT plan was conducted. The Wilcoxon signed rank test was used to assess the potential dosimetric differences between the 2 plans and PBS target coverage robustness relative to setup uncertainties. Results: The median patient age was 55 years (range 23-76). The primary site was cervical in 7, vaginal in 1, and endometrial in 3. Of the 11 patients, 7 received concurrent cisplatin, 1 each received sandwich carboplatin and paclitaxel chemotherapy, both sandwich and concurrent chemotherapy, and concurrent and adjuvant chemotherapy, and 1 received no chemotherapy. All patients completed treatment. Of the 9 patients who received concurrent chemotherapy, the rate of grade 2 and 3 hematologic toxicities was 33% and 11%, respectively. One patient (9%) developed grade 3 acute gastrointestinal toxicity; no patient developed grade ≥3 genitourinary toxicity. The volume of pelvic bone marrow, bladder, and small bowel receiving 10 to 30 Gy was significantly lower with PBS than with intensity modulated radiation therapy (P<.001). The target coverage for all PBS plans was robust relative to the setup uncertainties (P>.05) with the clinical target volume mean dose percentage received by 95% and 98% of the target volume coverage changes within 2% for the individual plans. Conclusions: Our results have demonstrated the clinical feasibility of PBS and the dosimetric advantages, especially for the low-dose sparing of normal tissues in the pelvis with the target robustness maintained relative to the setup uncertainties. Future studies with larger patient numbers are planned to further validate our preliminary findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Infrared nano-spectroscopy of ferroelastic domain walls in hybrid improper ferroelectric Ca 3 Ti 2 O 7

Ferroic materials are well known to exhibit heterogeneity in the form of domain walls. Understanding the properties of these boundaries is crucial for controlling functionality with external stimuli and for realizing their potential for ultra-low power memory and logic devices as well as novel computing architectures. In this work, we employ synchrotron-based near-field infrared nano-spectroscopy to reveal the vibrational properties of ferroelastic (90° ferroelectric) domain walls in the hybrid improper ferroelectric Ca 3 Ti 2 O 7 . By locally mapping the Ti-O stretching and Ti-O-Ti bending modes, we reveal how structural order parameters rotate across a wall. Thus, we link observed near-field amplitude changes to underlying structural modulations and test ferroelectric switching models against real space measurements of local structure. This initiative opens the door to broadband infrared nano-imaging of heterogeneity in ferroics.

36 MATERIALS SCIENCE↗

Development of an MC&A toolbox for liquid-fueled molten salt reactors with online reprocessing (Final Report)

A critical barrier to the deployment of MSRs is the absence of a well-defined nuclear material control and accounting (MC&A) approach, a vital prerequisite to meet NRC licensing requirements as well as facilitating future international exports. Liquid-fueled MSR variants (especially those incorporating online refueling or reprocessing) present a unique set of challenges to traditional nuclear material control and accountancy. Unlike solid-fueled light-water reactors, traditional item-counting methods cannot be applied as an accountancy strategy. Rather, MC&A approaches to MSR variants (including both uranium and thorium fueled designs) are more analogous to bulk material handling facilities (e.g., enrichment and reprocessing); yet further complicating matters is the fact that fuel medium is also highly radioactive. Meanwhile, the space of MSRs covers a broad range of design parameters, including thermal and fast spectra designs; operation in actinide breeder or burner modes, choice of actinide fuel used (e.g., 235 U, 232 Th / 233 U, denatured 233 U, etc.), pool or loop-type configuration, and even different salt chemistry. Each of these design choices introduce significant challenges to MC&A approaches within MSR facilities. We propose to bridge this gap for liquid-fueled MSRs by developing a modular, component-based test framework for evaluating viable process monitoring and MC&A techniques specifically suited to liquid-fueled MSR system variants employing online refueling or reprocessing. This test platform will consist of a toolbox of independent process modules representing discrete physical units (such as the reactor core, off-gas processing, decay tanks, and actinide separation units), each with its own self-contained physics responsive to the input mass flow, along with appropriate measurement models that can be coupled to key flow points. These dynamic physical signatures thus afford the ability to test the viability and efficacy of potential accountancy techniques under the full range of reactor operating conditions. As process modules are connected via mass flows, the result is a reconfigurable, generic MSR mass flow model capable of serving as an MC&A test platform for a broad spectrum of possible MSR configurations. The resulting MSR MC&A toolbox will enable robust assessment of accountancy strategies for this unique facility type, including analysis of physical feedbacks arising both from depletion of the fuel over time as well as from potential off-normal events, including those introduced by equipment failures (e.g., a pump failure) as well as by malicious action (i.e., attempts to divert material). The proposed toolbox both addresses a critical needs area for the MPACT analysis toolkit while leveraging existing MPACT-sponsored tools, especially with respect to simulation of measurement and accountancy techniques for advanced fuel cycle facilities. Beyond enabling new analysis capabilities for MSR systems, the design of this toolbox will be to such to maximize compatibility with existing MPACT tools, such to enhance existing facility MC&A analysis capabilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Testicular Doses in Image-Guided Radiotherapy of Prostate Cancer

Purpose: To investigate testicular doses contributed by kilovoltage cone-beam computed tomography (kVCBCT) during image-guided radiotherapy (IGRT) of prostate cancer. Methods and Materials: An EGS4 Monte Carlo code was used to calculate three-dimensional dose distributions from kVCBCT on 3 prostate cancer patients. Absorbed doses to various organs were compared between intensity-modulated radiotherapy (IMRT) treatments and kVCBCT scans. The impact of CBCT scanning mode, kilovoltage peak energy (kVp), and CBCT field span on dose deposition to testes and other organs was investigated. Results: In comparison with one 10-MV IMRT treatment, a 125-kV half-fan CBCT scan delivered 3.4, 3.8, 4.1, and 5.7 cGy to the prostate, rectum, bladder, and femoral heads, respectively, accounting for 1.7%, 3.2%, 3.2%, and 8.4% of megavoltage photon dose contributions. However, the testes received 2.9 cGy from the same CBCT scan, a threefold increase as compared with 0.7 cGy received during IMRT. With the same kVp, full-fan mode deposited much less dose to organs than half-fan mode, ranging from 9% less for prostate to 69% less for testes, except for rectum, where full-fan mode delivered 34% more dose. As photon beam energy increased from 60 to 125 kV, kVCBCT-contributed doses increased exponentially for all organs, irrespective of scanning mode. Reducing CBCT field span from 30 to 10 cm in the superior-inferior direction cut testicular doses from 5.7 to 0.2 cGy in half-fan mode and from 1.5 to 0.1 cGy in full-fan mode. Conclusions: Compared with IMRT, kVCBCT-contributed doses to the prostate, rectum, bladder, and femoral heads are clinically insignificant, whereas dose to the testes is threefold more. Full-fan CBCT usually deposits much less dose to organs (except for rectum) than half-fan mode in prostate patients. Kilovoltage CBCT-contributed doses increase exponentially with photon beam energy. Reducing CBCT field significantly cuts doses to testes and other organs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Additive Manufacturing for Cost Efficient Production of Compact Ceramic Heat Exchangers and Recuperators

An additive manufacture technique known as laminated object manufacturing (LOM) was used to fabricate compact ceramic heat exchanger prototypes. LOM uses precision CO2 laser cutting of ceramic green tapes, which are then precision stacked to build a 3D object with fine internal features. Modeling was used to develop prototype designs and predict the thermal response, stress, and efficiency in the ceramic heat exchangers. Build testing and materials analyses were used to provide feedback for the design selection. During this development process, laminated object manufacturing protocols were established. This included laser optimization, strategies for fine feature integrity, lamination fluid control, green handling, and firing profile. Three full size prototypes were fabricated using two different designs. One prototype was selected for performance testing. During testing, cross talk leakage prevented the application of a high pressure differential, however, the prototype was successful at withstanding the high temperature operating conditions (1300 °F). In addition, analysis showed that the bulk of the part did not have cracks or leakage issues. This led to the development of a module method for next generation LOM heat exchangers. A scale-up cost analysis showed that given a purpose built LOM system, these ceramic heat exchangers would be affordable for the applications.

01 COAL, LIGNITE, AND PEAT↗

Analysis of a Single Year of Performance Data for Thin Film Modules Deployed at NREL and NISE

The National Renewable Energy Laboratory (NREL) and National Institute of Solar Energy (NISE), located in the United States and India, respectively, have partnered to deploy and monitor modules of three different thin film technologies, to compare the performance and/or degradation between the two sites. This report analyzes a single year of performance data (May 2014 -- May 2015) for the three thin film technologies, exploring the modules' performance under standard test conditions and monthly performance ratios, as well as fill factors varying season, light level, and temperature.

14 SOLAR ENERGY↗

Progress on Demonstration of a MOOSE-Based Coupled Capability for Hot Channel Factors in Fast Reactors

Hot channel factors (HCFs) are computed values that account for the impact on predicted peak fuel, cladding, and coolant temperatures due to uncertainties in the as-built reactor’s material properties and geometry as well as uncertainties due to modeling approximations. Reduction in computed HCF values via reduction or elimination of modeling approximations may translate to significant economic savings if the reactor power can be raised due to the extra temperature margin gained. While limited historical datasets exist for sodium-cooled fast reactors (SFRs), there are no available HCF data for lead-cooled fast reactors (LFRs) outside of work generated previously within NEAMS. The computation of HCFs involves insights from reactor physics, thermal fluids and heat conduction calculations to determine how the peak temperatures respond to various uncertainties in the design. Due to the significant advantages for multi-physics coupling offered by the MOOSE framework, Griffin (MOOSE-based reactor physics code), MOOSE Heat Conduction Module, and Cardinal (MOOSE-wrapped multi-physics application which includes the NekRS thermal fluids code) are being coupled together using the MOOSE MultiApp System to develop a highfidelity multi-physics modeling capability for HCF simulations. This high-fidelity coupling workflow may also be beneficial for other fast reactor applications in the future. In previous work, Griffin and NekRS were individually assessed to ensure the necessary capabilities were in place. This work describes initial efforts to couple the codes (including folding in the MOOSE Heat Conduction Module) and determining the workflow for the perturbed calculations which will leverage the Stochastic Tools Module (STM). To our knowledge, this is the first coupling of Griffin and NekRS as well as the first exploratory use of Stochastic Tools Module for Cardinal. In this report, the neutronics code Griffin, the heat conduction solver in MOOSE, and the MOOSE-wrapped application containing NekRS (Cardinal) are linked together to demonstrate the coupled capability. Griffin and Cardinal are linked dynamically by specifying shared libraries. Different coupling hierarchies are tested for selecting the most appropriate coupling strategy. A coupling scheme is selected based on the efficiency of calculation and ease of data communication. Multiple tests are performed to choose suitable mesh structure, model configurations, scheme setup and boundary conditions to avoid loss of energy due to data interpolation between different modules or weak imposition of fluxes in finite element codes. Computational experiments are performed to study the tolerance control of each type of iteration to avoid false convergence. The coupled capability is demonstrated in both single pin and 7-pin models based on LFR materials and geometry. The study finds that the use of too large a time step size in the heat conduction module can lead to temperature oscillation even though the heat conduction equation does not have a time-derivative kernel, but only the time-dependent boundary condition. A 7-pin model without duct region achieved good convergence in the coupled calculation while a 7 pin model with duct region experienced data communication issues which need to be resolved.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Continued Benefit to Rectal Separation for Prostate Radiation Therapy: Final Results of a Phase III Trial

Purpose: SpaceOAR, a Food and Drug Administration–approved hydrogel intended to create a rectal–prostate space, was evaluated in a single-blind phase III trial of image guided intensity modulated radiation therapy. A total of 222 men were randomized 2:1 to the spacer or control group and received 79.2 Gy in 1.8-Gy fractions to the prostate with or without the seminal vesicles. The present study reports the final results with a median follow-up period of 3 years. Methods and Materials: Cumulative (Common Terminology Criteria for Adverse Events, version 4.0) toxicity was evaluated using the log-rank test. Quality of life (QOL) was examined using the Expanded Prostate Cancer Index Composite (EPIC), and the mean changes from baseline in the EPIC domains were tested using repeated measures models. The proportions of men with minimally important differences (MIDs) in each domain were tested using repeated measures logistic models with prespecified thresholds. Results: The 3-year incidence of grade ≥1 (9.2% vs 2.0%; P=.028) and grade ≥2 (5.7% vs 0%; P=.012) rectal toxicity favored the spacer arm. Grade ≥1 urinary incontinence was also lower in the spacer arm (15% vs 4%; P=.046), with no difference in grade ≥2 urinary toxicity (7% vs 7%; P=0.7). From 6 months onward, bowel QOL consistently favored the spacer group (P=.002), with the difference at 3 years (5.8 points; P<.05) meeting the threshold for a MID. The control group had a 3.9-point greater decline in urinary QOL compared with the spacer group at 3 years (P<.05), but the difference did not meet the MID threshold. At 3 years, more men in the control group than in the spacer group had experienced a MID decline in bowel QOL (41% vs 14%; P=.002) and urinary QOL (30% vs 17%; P=.04). Furthermore, the control group were also more likely to have experienced large declines (twice the MID) in bowel QOL (21% vs 5%; P=.02) and urinary QOL (23% vs 8%; P=.02). Conclusions: The benefit of a hydrogel spacer in reducing the rectal dose, toxicity, and QOL declines after image guided intensity modulated radiation therapy for prostate cancer was maintained or increased with a longer follow-up period, providing stronger evidence for the benefit of hydrogel spacer use in prostate radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Manufacturing Supply Chain Development for Modular Solar-Thermochemical Conversion Platform - CRADA 387 (Final Report)

Modular chemical process intensification (MCPI) is an emerging field where chemical processing is performed using small-scale modular equipment instead of conventional large centralized chemical plants. Conventional chemical plants benefit from economies of scale that encourage scale-up to ever larger plants. A goal of MCPI is to develop technology that intensifies processing so that equipment can be dramatically smaller and integrated into modular systems. Scale-up occurs by adding more modules in parallel rather than making the equipment larger. A key concept is that equipment and modules can ultimately be cheaper by leveraging economies of mass production, analogous to the automotive industry, in manufacturing the equipment. This project made significant progress toward this outcome by meeting the RAPID institute metric to reduce equipment cost by 20% for each doubling in manufacturing volume. The MCPI application was thermochemical technology that is being commercialized by STARS Technology Corporation, one of the CRADA partners. The technology converts solar and renewable power to chemical energy to produce renewable hydrogen, fuels, and chemicals. The benefit to the public is reduction in greenhouse gases that are contributing to climate change. The project transitioned the steam methane reforming (SMR) reactor from conventional fabrication methods to additive manufacturing (AM) direct metal laser sintering (DMLS) process. This is projected to reduce the cost of making a reactor by 58% when producing 100 reactors per year. Innovations in the DMLS process produced a patented design that reduces reactor weight by 60%. Reductions in material costs and processing time extend the DMLS advantage to higher production volumes. The new design promises to be 38% cheaper than the conventional processes at 1000 units per year. The resulting 87% reduction in the steam methane reforming (SMR) module cost in scaling from current costs meets the RAPID metric. The project was successful in producing and testing the first ever additively manufactured SMR reactors. A reactor achieved over 82% efficiency in converting electric power to chemical energy, which is a world record for an inductively heated SMR. The project has contributed to the design and assembly of a first demonstration plant that is headed to a hydrogen bus filling station in Thousand Palms, CA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗