Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Feasibility study on using fast calorimetry technique to measure a mass attribute as part of a treaty verification regime

The attribute measurement technique provides a method for determining whether or not an item containing special nuclear material (SNM) possesses attributes that fall within an agreed upon range of values. One potential attribute is whether the mass of an SNM item is larger than some threshold value that has been negotiated as part of a nonproliferation treaty. While the historical focus on measuring mass attributes has been on using neutron measurements, calorimetry measurements may be a viable alternative for measuring mass attributes for plutonium-bearing items. Traditionally, calorimetry measurements have provided a highly precise and accurate determination of the thermal power that is being generated by an item. In order to achieve this high level of precision and accuracy, the item must reach thermal equilibrium inside the calorimeter prior to determining the thermal power of the item. Because the approach to thermal equilibrium is exponential in nature, a large portion of the time spent approaching equilibrium is spent with the measurement being within {approx}10% of its final equilibrium value inside the calorimeter. Since a mass attribute measurement only needs to positively determine if the mass of a given SNM item is greater than a threshold value, performing a short calorimetry measurement to determine how the system is approaching thermal equilibrium may provide sufficient information to determine if an item has a larger mass than the agreed upon threshold. In previous research into a fast calorimetry attribute technique, a two-dimensional heat flow model of a calorimeter was used to investigate the possibility of determining a mass attribute for plutonium-bearing items using this technique. While the results of this study looked favorable for developing a fast calorimetry attribute technique, additional work was needed to determine the accuracy of the model used to make the calculations. In this paper, the results from the current work investigating the fast calorimetry attribute technique will be presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design of a technique to measure the density of ultracold atoms in a short-period optical lattice in three dimensions with single-atom sensitivity

A measurement technique is described that has the potential to map the atomic site occupancies of ultracold atoms in a short-period three-dimensional optical lattice. The method uses accordion and pinning lattices, together with polarization gradient cooling and fluorescence detection, to measure the positions of individual atoms within the sample in three dimensions at a resolution of around half the atomic resonant wavelength. The method measures the site occupancy, rather than the parity of the site occupancy, of atoms in the lattice. It is expected that such measurements hold significant potential for the study of ultracold quantum dynamics.

74 ATOMIC AND MOLECULAR PHYSICS↗

An ultrasonic technique to measure the depth of burn wounds in humans

Whenever ultrasound encounters discontinuity in its medium of propagation, some energy is reflected from the interface. Such reflections or echoes occur when incident energy encounters the front skin, viable/necrotic, and dermis/fat skin tissue interfaces. It was shown that the most probable cause of the viable/necrotic interface is the uncoiling of collagen in the necrotic tissue, which can cause a reflection at the viable/necrotic interface of approximately 10 percent of the wave amplitude, and is approximately the same as that from the other two interfaces noted. The instrument, still in the prototype stage, was designed to detect the various reflections from within the skin layer. It is shown that, by studying the timing between the various echoes, one can use ultrasound as an aid in diagnosing the depth of burned skin tissue in humans. The instrument is a 60-MHz A-scan unit, modified to more easily identify the echoes occurring within the short time interval during which the reflections are received from the skin layers. A high frequency unit was selected so that various transducers could be utilized to optimize the system. Signal conditioning circuits were modified and added to provide an adequate display of the principle reflections expected. The unit was successful in studying burned tissue in pigs and was recently used to study burn wounds in humans. Measurement techniques and preliminary results are presented.

Yost, William T.↗

Improved Techniques for Measuring Static Ground Wind Loads on the NASA Space Launch System Mobile Launcher 2

Vertical distribution of static ground wind loads was directly measured on Mobile Launcher ground support hardware to the NASA Space Launch System (SLS) at 1.75% scale in the Langley Research Center 14- by 22-Foot Subsonic Tunnel. Low-speed wind tunnel testing in the liftoff phase of flight was conducted for the SLS Block 1B family of rockets with their associated ground support systems. Improved methods for measuring and estimating static ground wind loads on the launch tower assembly are introduced in detail. A novel, distributed loads measurement technique is introduced and compared against lower-fidelity, previously utilized methods.

Ground Wind Loads↗

A technique for measuring the quality of an elliptically bent pentaerythritol [PET(002)] crystal

We present a technique for determining the X-ray spectral quality from each region of an elliptically curved PET(002) crystal. The investigative technique utilizes the shape of the crystal rocking curve which changes significantly as the radius of curvature changes. This unique quality information enables the spectroscopist to verify where in the spectral range that the spectrometer performance is satisfactory and where there are regions that would show spectral distortion. A collection of rocking curve measurements for elliptically curved PET(002) has been built up in our X-ray laboratory. The multi-lamellar model from the XOP software has been used as a guide and corrections were applied to the model based upon measurements. But, the measurement of R{sub I} at small radius of curvature shows an anomalous behavior; the multi-lamellar model fails to show this behavior. The effect of this anomalous R{sub I} behavior on an X-ray spectrometer calibration is calculated. It is compared to the multi-lamellar model calculation which is completely inadequate for predicting R{sub I} for this range of curvature and spectral energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Techniques for measurement of vertical and horizontal velocities: Monostatic versus bistatic measurements

Three techniques of direct measurement are presented from which velocities may be obtained: (1) Doppler frequency shift, (2) spaced antenna drift, (3) spatially modulated transverse beam measurements. Emphasis is placed on the Doppler frequency measurement approach. It will compare bistatic with monostatic configurations as regards received power (or sensitivity), spatial resolution, Doppler shift and avoidance of ground clutter.

Waterman, A. T.↗

Measuring contact angle and meniscus shape with a reflected laser beam

Side-view imaging of the contact angle between an extended planar solid surface and a liquid is problematic. Even when aligning the view perfectly parallel to the contact line, focusing one point of the contact line is not possible. We describe a new measurement technique for determining contact angles with the reflection of a widened laser sheet on a moving contact line. We verified this new technique measuring the contact angle on a cylinder, rotating partially immersed in a liquid. A laser sheet is inclined under an angle φ to the unperturbed liquid surface and is reflected off the meniscus. Collected on a screen, the reflection image contains information to determine the contact angle. When dividing the laser sheet into an array of laser rays by placing a mesh into the beam path, the shape of the meniscus can be reconstructed from the reflection image. We verified the method by measuring the receding contact angle versus speed for aqueous cetyltrimethyl ammonium bromide solutions on a smooth hydrophobized as well as on a rough polystyrene surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reduced and Validated Kinetic Mechanisms for Hydrogen-CO-sir Combustion in Gas Turbines

Rigorous experimental, theoretical, and numerical investigation of various issues relevant to the development of reduced, validated kinetic mechanisms for synthetic gas combustion in gas turbines was carried out - including the construction of new radiation models for combusting flows, improvement of flame speed measurement techniques, measurements and chemical kinetic analysis of H{sub 2}/CO/CO{sub 2}/O{sub 2}/diluent mixtures, revision of the H{sub 2}/O{sub 2} kinetic model to improve flame speed prediction capabilities, and development of a multi-time scale algorithm to improve computational efficiency in reacting flow simulations.

08 HYDROGEN↗

Molecular Rayleigh Scattering Techniques Developed for Measuring Gas Flow Velocity, Density, Temperature, and Turbulence

Nonintrusive optical point-wise measurement techniques utilizing the principles of molecular Rayleigh scattering have been developed at the NASA Glenn Research Center to obtain time-averaged information about gas velocity, density, temperature, and turbulence, or dynamic information about gas velocity and density in unseeded flows. These techniques enable measurements that are necessary for validating computational fluid dynamics (CFD) and computational aeroacoustic (CAA) codes. Dynamic measurements allow the calculation of power spectra for the various flow properties. This type of information is currently being used in jet noise studies, correlating sound pressure fluctuations with velocity and density fluctuations to determine noise sources in jets. These nonintrusive techniques are particularly useful in supersonic flows, where seeding the flow with particles is not an option, and where the environment is too harsh for hot-wire measurements.

Mielke, Amy F.↗

Progress in laser-spectroscopic techniques for aerodynamic measurements - An overview

An overview is given of the capabilities and recent progress in laser-spectroscopic measurement techniques for use in aerodynamic test facilities and flight research vehicles. It includes a survey of the literature which is centered on this application of laser spectroscopy. The intended reader is the specialist in experimental fluid dynamics who is not intimately familiar with the physics or applications of laser spectroscopy. Thus, some discussion is also included of the nature of each laser-spectroscopic technique and the practical aspects of its use for aerodynamic measurements. The specific techniques reviewed include laser absorption, laser-induced fluorescence, laser Rayleigh scattering, and laser Raman scattering including spontaneous and coherent processes.

Mckenzie, Robert L.↗

Direct-reading group-delay measurement

Technique for measuring modulation signal retardation in microwave components gives direct plot of dependence of delay time on carrier frequency. Recorder sensitivity can be adjusted to give convenient scale factor for group delay. From family of such recordings, it is possible to observe changes in group delay due to temperature, mechanical stress, and other factors.

Trowbridge, D. L.↗

A new technique for the measurement of surface shear stress vectors using liquid crystal coatings

Research has recently shown that liquid crystal coating (LCC) color-change response to shear depends on both shear stress magnitude and direction. Additional research was thus conducted to extend the LCC method from a flow-visualization tool to a surface shear stress vector measurement technique. A shear-sensitive LCC was applied to a planar test surface and illuminated by white light from the normal direction. A fiber optic probe was used to capture light scattered by the LCC from a point on the centerline of a turbulent, tangential-jet flow. Both the relative shear stress magnitude and the relative in-plane view angle between the sensor and the centerline shear vector were systematically varied. A spectrophotometer was used to obtain scattered-light spectra which were used to quantify the LCC color (dominant wavelength) as a function of shear stress magnitude and direction. At any fixed shear stress magnitude, the minimum dominant wavelength was measured when the shear vector was aligned with and directed away from the observer; changes in the relative in-plane view angle to either side of this vector/observer aligned position resulted in symmetric Gaussian increases in measured dominant wavelength. Based on these results, a vector measurement methodology, involving multiple oblique-view observations of the test surface, was formulated. Under present test conditions, the measurement resolution of this technique was found to be +/- 1 deg for vector orientations and +/- 5% for vector magnitudes. An approach t o extend the present methodology to full-surface applications is proposed.

Reda, Daniel C.↗

Advanced techniques for the measurement of multiple recombination parameters in solar cells

A survey of bulk recombination measurement techniques was presented. Classical methods were reviewed along with their limiting assumptions and simplifications. A modulated light measurement system was built and showed the large effects of junction capacitance. Techniques for extension of classical methods for measurement of multiparameter multiregression measurements were identified and analyzed.

Newhouse, M.↗

Optical Flow-Field Techniques Used for Measurements in High-Speed Centrifugal Compressors

The overall performance of a centrifugal compressor depends on the performance of the impeller and diffuser as well as on the interactions occurring between these components. Accurate measurements of the flow fields in each component are needed to develop computational models that can be used in compressor design codes. These measurements must be made simultaneously over an area that covers both components so that researchers can understand the interactions occurring between the two components. Optical measurement techniques are being used at the NASA Lewis Research Center to measure the velocity fields present in both the impeller and diffuser of a 4:1 pressure ratio centrifugal compressor operating at several conditions ranging from design flow to surge. Laser Doppler Velocimetry (LDV) was used to measure the intrablade flows present in the impeller, and the results were compared with analyses obtained from two three-dimensional viscous codes. The development of a region of low throughflow velocity fluid within this high-speed impeller was examined and compared with a similar region first observed in a large low-speed centrifugal impeller at Lewis. Particle Image Velocimetry (PIV) is a relatively new technique that has been applied to measuring the diffuser flow fields. PIV can collect data rapidly in the diffuser while avoiding the light-reflection problems that are often encountered when LDV is used. The Particle Image Velocimeter employs a sheet of pulsed laser light that is introduced into the diffuser in a quasi-radial direction through an optical probe inserted near the diffuser discharge. The light sheet is positioned such that its centerline is parallel to the hub and shroud surfaces and such that it is parallel to the diffuser vane, thereby avoiding reflections from the solid surfaces. Seed particles small enough to follow the diffuser flow are introduced into the compressor at an upstream location. A high-speed charge-coupled discharge (CCD) camera is synchronized to the laser pulse rate; this allows it to capture images of seed particle position that are separated by a small increment in time. A crosscorrelation of a particle's position in two consecutive images provides an estimate of flow velocity and direction. Multiple image pairs obtained in rapid succession at a particular flow condition provide enough measurements for statistical significance. PIV provides simultaneous velocity measurements over the entire plane that is illuminated by the light sheet instead of at a single point, as is the case when LDV is used. PIV has a further advantage in that the laser light pulse can be triggered by an external source such as a high-response pressure transducer. This feature will allow PIV to synchronize flow imaging to physical phenomena such as rotating stall or stall precursor waves. We hope that this technique can be used to obtain images of the flow field during and just prior to stall.

Skoch, Gary J.↗

DEVELOPMENT OF AN IN-PILE TECHNIQUE FOR THERMAL CONDUCTIVITY MEASUREMENT

Thermophysical properties of advanced fuels and materials during irradiation must be known prior to their use in existing, advanced, or next generation reactors. Fuel thermal conductivity is one of the most important properties for predicting fuel performance and reactor safety. This paper discusses a joint Utah State University (USU)/Idaho National Laboratory (INL) project to investigate an in-pile fuel thermal conductivity measurement technique using a surrogate fuel rod. The method used a surrogate fuel rod with Joule heating to simulate volumetric heat generation as a proof-of-concept test in-pile application. Carbon structural foam, CFOAM®, a product of Touchtone Research Laboratory was chosen as the surrogate material because of the variable electrical and thermal properties upon fabrication. To stay within the surrogate fuel rod requirements, electrical and thermal properties were tailored by Touchtone Research Laboratory to match required values. This paper describes are the techniques used for quantifying thermal conductivity. A description of the test setup and preliminary results are presented. Two thermocouples are inserted into a 1-inch diameter, 6-inch long rod of CFOAM® at known locations. Knowing the applied volumetric heat to the rod by electrical resistance heating, the thermal conductivity can be calculated. Sensitivities of this measurement can also found by analysis and testing of different configurations of the sample setup. Verification of thermal conductivity is found by measuring the thermal properties of the CFOAM® using different methods. Thermal properties including thermal conductivity, specific heat capacity, and expansion coefficient of two types of CFOAM®, CFOAM20 and CFOAM25, were characterized using standard measurement techniques, such as laser flash, differential scanning calorimetry, and pushrod dilatometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗