Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

OARE and SAMS on STS-94/MSL-1

Four microgravity acceleration measurement instruments were included on MSL-1 to measure the accelerations and vibrations to which science experiments were exposed during their operation on the mission. The data were processed and presented to the principal investigators in a variety of formats to aid their assessment of the microgravity environment during their experiment operations. Two accelerometer systems managed by the NASA Lewis Research Center (LeRC) supported the MSL-1 mission: the Orbital Acceleration Research Experiment (OARE), and the Space Acceleration Measurement System (SAMS). In addition, the Microgravity Measurement Assembly (MMA) and the Quasi- Steady Acceleration Measurement (QSAM) system, both sponsored by the Microgravity Research Division, collected acceleration data as a part of the MSL-1 mission. The NIMA was funded and designed by the European Space Agency in the Netherlands (ESA/ESTEC), and the QSAM system was funded and designed by the German Space Agency (DLR). The Principal Investigator Microgravity Services (PIMS) project at the NASA Lewis Research Center (LeRC) supports Principal Investigators (PIs) of the Microgravity science community as they evaluate the effects of acceleration on their experiments. PIMS primary responsibility is to support NASA-sponsored investigators in the area of acceleration data analysis and interpretation. A mission summary report was prepared and published by PIMS in order to furnish interested experiment investigators with a guide for evaluating the acceleration environment during the MSL-1 mission.

Moskowitz, Milton↗

Analysis of Differential Die Away Instrument Simulated Performance Using Boiling Water Reactor Spent Fuel Assemblies

As part of evaluating the performance of various Non-Destructive Assay (NDA) instruments measuring the plutonium content and other information about spent nuclear fuel, the Next Generation of Safeguards Initiative (NGSI) Spent Fuel (SF) Project generated spent fuel libraries containing the composition of spent fuel assemblies originating from various reactors, initial enrichments (IE), burnups (BU), and cooling times (CT). Spent Fuel Library (SFL) number 5 (SFL5), representing Boiling Water Reactor (BWR) assemblies, was created as part of a “Gentleman’s Agreement” with Sweden to examine if the Differential Die Away (DDA) instrument performs similarly for BWR assemblies as for the Pressurized Water Reactor (PWR) ones. The difference between PWRs and BWRs is that BWRs have a large axial variation in moderator density because it is in the form of water at the bottom of the reactor but turns into steam as it gets warmer at the top of the reactor; thus, more plutonium builds up at the bottom of each assembly than at the top. In a PWR, the moderator density varies slightly from the bottom to the top, but since it is pressurized, the changes are not as significant with respect to the burnup and plutonium distributions. BWR assemblies are also typically smaller than PWR ones, which could affect detector performance. Since Sweden has both PWR and BWR assemblies, it is anticipated that we will be deploying the DDA instrument to measure both spent fuel assembly (SFA) types.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A photophonic instrument concept to measure atmospheric aerosol absorption

A laboratory model of an instrument to measure the absorption of atmospheric aerosols was designed, built, and tested. The design was based on the photophonic phenomenon discovered by Bell and an acoustic resonator developed by Helmholtz. Experiments were done to show ways the signal amplitude could be improved and the noise reduced and to confirm the instrument was sensitive enough to be practical. The research was undertaken to develop concepts which show promise of being improvements on the instruments that are presently used to measure the absorption of the Sun's radiation by the Earth's atmospheric aerosols.

Engle, C. D.↗

Underestimation of column NO 2 amounts from the OMI satellite compared to diurnally varying ground-based retrievals from multiple PANDORA spectrometer instruments

Retrievals of total column NO 2 (TCNO 2 ) are compared for 14 sites from the Ozone Measuring Instrument (OMI using OMNO2-NASA v3.1) on the AURA satellite and from multiple ground-based PANDORA spectrometer instruments making direct-sun measurements. While OMI accurately provides the daily global distribution of retrieved TCNO 2 , OMI almost always underestimates the local amount of TCNO 2 by 50 % to 100 % in polluted areas, while occasionally the daily OMI value exceeds that measured by PANDORA at very clean sites. Compared to local ground-based or aircraft measurements, OMI cannot resolve spatially variable TCNO 2 pollution within a city or urban areas, which makes it less suitable for air quality assessments related to human health. In addition to systematic underestimates in polluted areas, OMI's selected 13:30 Equator crossing timepolar orbit causes it to miss the frequently much higher values of TCNO 2 that occur before or after the OMI overpass time. Six discussed Northern Hemisphere PANDORA sites have multi-year data records (Busan,Seoul, Washington DC, Waterflow, New Mexico, Boulder, Colorado, and Mauna Loa),and one site in the Southern Hemisphere (Buenos Aires, Argentina). The first four of these sites and Buenos Aires frequently have high TCNO 2 (TCNO 2 > 0.5 DU). Eight additional sites have shorter-term data records in the US and South Korea. One of these is a 1-year data record from a highly polluted site at City College in New York City with pollution levels comparable to Seoul, South Korea. OMI-estimated air mass factor, surface reflectivity, and the OMI 24 km × 13 km FOV (field of view)are three factors that can cause OMI to underestimate TCNO 2 . Because of the local inhomogeneity of NO x emissions, the large OMI FOV is the most likely factor for consistent underestimates when comparing OMI TCNO 2 to retrievals from the small PANDORA effective FOV (measured in m 2 ) calculated from the solar diameter of 0.5°.

47 OTHER INSTRUMENTATION↗

Fluorescence of ceramic color standards

Fluorescence has been found in color standards available for use in calibration and verification of color measuring instruments. The fluorescence is excited at wavelengths below about 600 nm and emitted above 700 nm, within the response range of silicon photodiodes, but at the edge of the response of most photomultipliers and outside the range commonly scanned in commercial colorimeters. The degree of fluorescence on two of a set of 12 glossy ceramic tiles is enough to introduce significant error when those tiles have been calibrated in one mode of measurement and are used in another. We report the nature of the fluorescence and the implications for color measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Far-Infrared Spectrometer Measures Stratospheric Hydroxyl

Far Infrared Limb Observing Spectrometer is balloon-borne instrument measuring far-infrared emission from limb of atmosphere. Operates in two spectral channels in wave-number range of 101 to 118 cm(to the negative 1st power). Range contains spectral lines of several molecules and radicals of current scientific interest. Instrument designed primarily to obtain data on distribution of hydroxyl radicals, which play central role in chemistry of ozone in stratosphere. Measurements contribute to understanding of "ozone hole" in stratosphere.

Peterson, Dean B.↗

A Balloon-Borne Cloud Condensation Nuclei Counter

A balloon-borne instrument was constructed for observations of vertical profiles of cloud condensation nucleus (CCN) concentrations, active at 1% supersaturation. Droplet concentration in the static thermal-gradient diffusion chamber is deduced from the amount of scattered laser light detected by a photodetector. The photodetector is calibrated using a video camera and computer system to count the number of droplets produced from NaCl aerosol. Preliminary data are available from nine early morning profiles obtained at Laramie, Wyoming, between June 1995 and January 1997. To complement the CCN measurements, instruments that measure condensation nuclei (CN) and aerosols with diameter greater than 0.30 micrometers (D(sub 0.3) were also included on the balloon package. CCN concentrations exhibited a general decrease from the surface to the top of the boundary layers, were generally uniform through well-mixed layers, and show variability above well-mixed layers. In general, the structure of the CCN profile appears to be closely related to the structure in the CN and D(sub 0.3) profiles. Summer profiles generally have CCN concentration greater than 200/cu cm up to 500 mbar, whereas winter profiles are less than 200/cu cm at all levels.

Delene, David J.↗

Model Evaluation by Measurements from Collocated Remote Sensors in Complex Terrain

Model improvement efforts involve an evaluation of changes in model skill in response to changes in model physics and parameterization. When using wind measurements from various remote sensors to determine model forecast accuracy, it is important to understand the effects of measurement-uncertainty differences among the sensors resulting from differences in the methods of measurement, the vertical and temporal resolution of the measurements, and the spatial variability of these differences. Here we quantify instrument measurement variability in 80-m wind speed during WFIP2 and its impact on the calculated errors and the change in error from one model version to another. Here the model versions tested involved updates in model physics from HRRRv1 to HRRRv4, and reductions in grid interval from 3 km to 750 m. Model errors were found to be 2–3 m s –1 . Differences in errors as determined by various instruments at each site amounted to about 10% of this value, or 0.2–0.3 m s –1 . Changes in model skill due to physics or grid-resolution updates also differed depending on the instrument used to determine the errors; most of the instrument-to-instrument differences were ~0.1 m s –1 , but some reached 0.3 m s –1 . All instruments at a given site mostly showed consistency in the sign of the change in error. In two examples, though, the sign changed, illustrating a consequence of differences in measurements: errors determined using one instrument may show improvement in model skill, whereas errors determined using another instrument may indicate degradation. This possibility underscores the importance of having accurate measurements to determine the model error.

54 ENVIRONMENTAL SCIENCES↗

Global Distribution and 14-Year Changes in Erythemal Irradiance, UV Atmospheric Transmission, and Total Column Ozone 2005 – 2018 Estimated from OMI and EPIC Observations

Satellite data from the Ozone Measuring Instrument (OMI) and Earth Polychromatic Imaging Camera (EPIC) are used to study changes and global distribution of UV erythemal irradiance in mW/m(exp 2) E(ζ,φ,z,t) and the dimensionless UV index (E/25 mWm(exp 2)) over the Earth’s surface as a function of latitude ζ, longitude φ, altitude z, and time t. OMI time series data starting in January 2005 to December 2018 are used to estimate 14-year changes in erythemal irradiance, total column ozone TCO3, scene reflectivity LER, and aerosol absorption τA at specific land sites in the Northern and Southern Hemispheres using publicly available OMI data. Estimates of changes in atmospheric transmission ΔCτ(ζ,φ,z,t) derived from OMI measured cloud and haze reflectivity show an increase between 60°S to 45°S almost no average 14-year change from 55°S to 30°N but show an increase from 35°N to 55°N. This implies increased solar insolation at higher latitudes that suggests positive feedback for global warming. Changes in aerosol absorption of UV irradiance ΔCA(ζ,φ,z,t) derived from changes in τA are mostly in the equatorial region and at higher southern latitudes resulting in correlated changes in E. TCO3 derived from OMI data has increased at a rate of 2% per decade for the latitudes between 60°S to 10°N changing to a decrease of 1% per decade between 40°N to 60°N. The result is an average decrease in E(ζ,φ,z,t) at a rate of 2% per decade in the Southern Hemisphere and an increase between 40°N to 60°N. For some specific sites (latitudes from 55°S to 45°N) there has been little or no change in E(ζ,φ,z,t) for the period 2005 – 2018. Nearly half the sites show strong correlation effects of both short- and long-term cloud and absorbing aerosol change as well as anticorrelation with total column ozone change ΔTCO3. Synoptic EPIC data from the sunlit Earth are used to derive ozone and reflectivity needed for global images of the distribution of E(ζ,φ,z,t) from sunrise to sunset centered on the Americas, Europe-Africa, and Asia. EPIC data are used to show the latitudinal distribution of E(ζ,φ,z,t) from the equator to 75° for specific longitudes. Dangerously high amounts of erythemal irradiance (12 < UV index < 18) are found for many low latitude and high-altitude sites (e.g., San Pedro, Chile (2.45 km), La Paz, Bolivia (3.78 km). Lower UV indices at some equatorial or high-altitude sites (e.g., Quito, Ecuador) are moderated by the presence of persistent cloud effects. High UVI levels (UVI > 6) are also found at most mid-latitude sites during the summer months.

Ozone Measuring Instrument (OMI) and Earth Polychr↗

Implications of asymmetric beam geometry for convergent acoustic Doppler profilers

The focus of this research is to develop a measurement instrument to characterize complex flows at spatial and temporal resolutions pertinent to understanding hydrodynamic loads in zones of fluid-structure interaction. Foundational work has demonstrated that flow velocities can be measured at a fixed focal point using a convergent array of acoustic Doppler profiling (C-ADP) instruments. As an extension of this concept, the following approach describes an application of the technology to facilitate 3D velocity measurements at a dynamically adjustable focal point location. Furthermore, the ability to dynamically control the focal point location in real-time allows the instrument to survey velocities within a three-dimensional velocity field. The resulting configuration targets a combination of measurement fidelity and control that has not been achieved by existing remote flow measurement instrumentation in the marine environment.

Harding, Samuel F.↗

Nimbus-7 Total Ozone Mapping Spectrometer (TOMS) data products user's guide

Two tape products from the Total Ozone Mapping Spectrometer (TOMS) aboard the Nimbus-7 have been archived at the National Space Science Data Center. The instrument measures backscattered Earth radiance and incoming solar irradiance; their ratio -- the albedo -- is used in ozone retrievals. In-flight measurements are used to monitor changes in the instrument sensitivity. The algorithm to retrieve total column ozone compares the observed ratios of albedos at pairs of wavelengths with pair ratios calculated for different ozone values, solar zenith angles, and optical paths. The initial error in the absolute scale for TOMS total ozone is 3 percent, the one standard-deviation random error is 2 percent, and the drift is +/- 1.5 percent over 14.5 years. The High Density TOMS (HDTOMS) tape contains the measured albedos, the derived total ozone amount, reflectivity, and cloud-height information for each scan position. It also contains an index of SO2 contamination for each position. The Gridded TOMS (GRIDTOMS) tape contains daily total ozone and reflectivity in roughly equal area grids (110 km in latitude by about 100-150 km in longitude). Detailed descriptions of the tape structure and record formats are provided.

Mcpeters, Richard D.↗

Analysis of solar spectral irradiance measurements from the SBUV/2-series and the SSBUV instruments

The measurements of the solar ultraviolet spectral irradiance by the two Upper Atmosphere Research Satellite (UARS) solar instruments are validated to agree within their 2-Sigma calibration uncertainties of about 7 percent, as well as with measurements from the two solar instruments on the Shuttle Atmospheric Laboratory for Applications and Science (ATLAS) missions. Additionally, the precision of the two UARS data sets is better than the original 2 percent goal, especially at wavelengths greater than 160 nm. This excellent agreement can be credited to accurate pre-flight calibrations, comprehensive in-flight calibrations to track instrument degradation, and a coordinated validation program among the UARS and ATLAS solar instrument teams. The solar irradiance results presented here include those derived from UARS SUSIM, UARS SOLSTICE, ATLAS SUSIM and ATLAS SSBUV measurements on 29 March 1992 during the ATLAS-1 mission and on 15 April 1993 during the ATLAS-2 mission. Two ultraviolet spectra from 119 to 410 nm are derived as the weighted average of the UARS SOLSTICE and SUSIM measurements and are recommended as representative solar spectra for the period of the ATLAS-1 and ATLAS-2 missions. The ATLAS-1 mission occurred during the initial phase of the solar cycle 22 decline when solar activity was moderately high. The ATLAS-2 mission occurred later during the declining phase of the solar cycle 22 when solar activity was more moderate.

Cebula, Richard P.↗

Evaluating Diurnal Ozone Emissions: A Comparative Analysis of DSCOVR EPIC, PANDORA, and TOLNet Data for Space-Based Monitoring Assessment: A Case Study by ASDC

Stratospheric ozone occurs naturally in the upper atmosphere, forming a protective layer that shields us from the sun's harmful ultraviolet rays. Tropospheric ozone is not emitted directly into the air but is created by chemical reactions between nitrogen oxides (NOx) and volatile organic compounds (VOC). This reaction happens when pollutants emitted by cars, power plants, industrial boilers, refineries, chemical plants, and other sources chemically react in sunlight [1]. Therefore, increased levels of tropospheric ozone indicate the presence of pollutants in the air. While daily anthropogenic activity causes an increase of ground-level ozone, variation of stratospheric ozone changes happens much slower, so that variation of the total ozone column reflects the variation of the tropospheric column due to natural, e.g., wildfires and anthropogenic air pollution. Both total and tropospheric ozone column products are used in this study. The reflectance spectra measured by the Earth Polychromatic Imaging Camera (EPIC) instrument aboard the Deep Space Climate Observatory (DSCOVR) spacecraft are compared with a set of radiative transfer-derived lookup tables for the EPIC filter transmission functions and a wide range of ozone values to retrieve ozone with a maximum resolution of 18 km at the sub-satellite point [2]. EPIC provides total column ozone in level 2 and level 4 products and tropospheric column ozone in level 4 products. Both EPIC Ozone products [2] are available at the Atmospheric Science Data Center (ASDC) at NASA Langley Research Center [3, 4]. Pandora spectrometer instrument measures columnar amounts of trace gases in the atmosphere. These gases (O3, NO2, CH2O) absorb light from the sun at specific wavelengths in the ultraviolet-visible spectrum [5]. Using the theoretical solar spectrum as a reference, Pandora determines trace gas amounts using differential optical absorption spectroscopy (DOAS). Pandora ozone retrievals are available from the Pandonia Global Network [6]. Pandora data from North American major metropolitan areas, New York, NY, Washington DC, Los Angeles, CA, and Mexico City. Tropospheric Ozone Lidar Network (TOLNet) was established in 2012 to provide high spatiotemporal observations of tropospheric ozone to (1) better understand physical processes driving the ozone budget in various meteorological and environmental conditions and (2) validate the tropospheric ozone measurements of space-borne missions [7]. TOLNet data are available at ASDC [8]. While EPIC provides global coverage of ozone retrievals several times daily, temporal resolution may miss some features in daily ozone variations. Ground-based sensors such as Pandora spectrometers and TOLNet lidars provide better temporal resolution while missing continuous spatial coverage. The forthcoming ozone retrieval from the TEMPO mission [9] will provide better spatial and temporal coverage of air quality (including ozone) over North America. This study investigates whether EPIC ozone products can detect diurnal air quality variations and compare ozone temporal development with retrieval by ground-based instruments.

diurnal ozone emissions, DSCOVR EPIC, PANDORA, spa↗

Comprehensive Performance Calibration Guidance for Perovskites and Other Emerging Solar Cells

Emerging photovoltaic (PV) technologies (e.g., organic, perovskite, and solution processed quantum dot) have attracted remarkable attention with the rapid growth of their efficiencies, and their transition toward commercialization. Accurate and reliable efficiency measurements of these PV technologies are crucial, yet much more complicated than for conventional PV technologies due to the former's pronounced dynamic responses to changes in measurement conditions (e.g., current–voltage (I–V) scan rate and preconditioning) and their susceptibility to degradation. Adjustments to the measurement procedures are therefore necessary so that a reproducible “steady state” is reached during measurement. Furthermore, given the small size of many emerging cells, inappropriate device area definition and solar simulator setup can lead to measurement errors. Here, comprehensive efficiency calibration guidance is offered for emerging solar cells, including area measurement; spectral irradiance translation to standard test conditions; and steady-state electrical performance. The necessity of reporting steady-state efficiency is justified with a statistical performance comparison between conventional and steady-state I–V scans over hundreds of cells the group has received globally for efficiency certifications. The procedures described here do not require specialized measurement instrumentation; what matters most are changes to the measurement protocols. These described changes aim to enable better comparisons between reported efficiencies.

14 SOLAR ENERGY↗

Solar Resource Measurements in Canyon, Texas - Equipment Only Loan: Cooperative Research and Development Final Report, CRADA Number CRD-07-233

Site-specific, long-term, continuous, and high-resolution measurements of solar irradiance are important for developing renewable resource data. These data are used for several research and development activities consistent with the NREL mission: establish a national 30-year climatological database of measured solar irradiances; provide high-quality ground-truth data for satellite remote sensing validation; support development of radiative transfer models for estimating solar irradiance from available meteorological observations; and provide solar resource information needed for technology deployment and operations. Data acquired under this agreement will be available to the public through NREL's Measurement & Instrumentation Data Center (MIDC) or the Renewable Resource Data Center (RReDC). The MIDC offers a variety of standard data display, access, and analysis tools designed to address the needs of a wide user audience (e.g., industry, academia, and government interests).

14 SOLAR ENERGY↗

Human System Simulation in Support of Human Performance Technical Basis at NPPs

This paper focuses on strategies and progress toward establishing the Idaho National Laboratory’s (INL’s) Human Systems Simulator Laboratory at the Center for Advanced Energy Studies (CAES), a consortium of Idaho State Universities. The INL is one of the National Laboratories of the US Department of Energy. One of the first planned applications for the Human Systems Simulator Laboratory is implementation of a dynamic nuclear power plant simulation (NPP) where studies of operator workload, situation awareness, performance and preference will be carried out in simulated control rooms including nuclear power plant control rooms. Simulation offers a means by which to review operational concepts, improve design practices and provide a technical basis for licensing decisions. In preparation for the next generation power plant and current government and industry efforts in support of light water reactor sustainability, human operators will be attached to a suite of physiological measurement instruments and, in combination with traditional Human Factors Measurement techniques, carry out control room tasks in simulated advanced digital and hybrid analog/digital control rooms. The current focus of the Human Systems Simulator Laboratory is building core competence in quantitative and qualitative measurements of situation awareness and workload. Of particular interest is whether introduction of digital systems including automated procedures has the potential to reduce workload and enhance safety while improving situation awareness or whether workload is merely shifted and situation awareness is modified in yet to be determined ways. Data analysis is carried out by engineers and scientists and includes measures of the physical and neurological correlates of human performance. The current approach supports a user-centered design philosophy (see ISO 13407 “Human Centered Design Process for Interactive Systems, 1999) wherein the context for task performance along with the requirements of the end-user are taken into account during the design process and the validity of design is determined through testing of real end users

22 GENERAL STUDIES OF NUCLEAR REACTORS↗