An efficient Bayesian data-worth analysis using a multilevel Monte Carlo method

Improving the understanding of subsurface systems and thus reducing prediction uncertainty requires collection of data. As the collection of subsurface data is costly, it is important that the data collection scheme is cost-effective. Design of a cost-effective data collection scheme, i.e., data-worth analysis, requires quantifying model parameter, prediction, and both current and potential data uncertainties. Assessment of these uncertainties in large-scale stochastic subsurface hydrological model simulations using standard Monte Carlo (MC) sampling or surrogate modeling is extremely computationally intensive, sometimes even infeasible. In this paper, we propose an efficient Bayesian data-worth analysis using a multilevel Monte Carlo (MLMC) method. Compared to the standard MC that requires a significantly large number of high-fidelity model executions to achieve a prescribed accuracy in estimating expectations, the MLMC can substantially reduce computational costs using multifidelity approximations. Since the Bayesian data-worth analysis involves a great deal of expectation estimation, the cost saving of the MLMC in the assessment can be outstanding. While the proposed MLMC-based data-worth analysis is broadly applicable, we use it for a highly heterogeneous two-phase subsurface flow simulation to select an optimal candidate data set that gives the largest uncertainty reduction in predicting mass flow rates at four production wells. Finally, the choices made by the MLMC estimation are validated by the actual measurements of the potential data, and consistent with the standard MC estimation. But compared to the standard MC, the MLMC greatly reduces the computational costs.

97 MATHEMATICS AND COMPUTING↗

Elucidating dynamic metabolic physiology through network integration of quantitative time-course metabolomics

In this study, the increasing availability of metabolomics data necessitates novel methods for deeper data analysis and interpretation. We present a flux balance analysis method that allows for the computation of dynamic intracellular metabolic changes at the cellular scale through integration of time-course absolute quantitative metabolomics. This approach, termed “unsteady-state flux balance analysis” (uFBA), is applied to four cellular systems: three dynamic and one steady-state as a negative control. uFBA and FBA predictions are contrasted, and uFBA is found to be more accurate in predicting dynamic metabolic flux states for red blood cells, platelets, and Saccharomyces cerevisiae . Notably, only uFBA predicts that stored red blood cells metabolize TCA intermediates to regenerate important cofactors, such as ATP, NADH, and NADPH. These pathway usage predictions were subsequently validated through 13 C isotopic labeling and metabolic flux analysis in stored red blood cells. Utilizing time-course metabolomics data, uFBA provides an accurate method to predict metabolic physiology at the cellular scale for dynamic systems.

60 APPLIED LIFE SCIENCES↗

Modeling the Swift BAT Trigger Algorithm with Machine Learning

To draw inferences about gamma-ray burst (GRB) source populations based on Swift observations, it is essential to understand the detection efficiency of the Swift burst alert telescope (BAT). This study considers the problem of modeling the Swift BAT triggering algorithm for long GRBs, a computationally expensive procedure, and models it using machine learning algorithms. A large sample of simulated GRBs from Lien et al. (2014) is used to train various models: random forests, boosted decision trees (with AdaBoost), support vector machines, and artificial neural networks. The best models have accuracies of approximately greater than 97% (approximately less than 3% error), which is a significant improvement on a cut in GRB flux which has an accuracy of 89:6% (10:4% error). These models are then used to measure the detection efficiency of Swift as a function of redshift z, which is used to perform Bayesian parameter estimation on the GRB rate distribution. We find a local GRB rate density of eta(sub 0) approximately 0.48(+0.41/-0.23) Gpc(exp -3) yr(exp -1) with power-law indices of eta(sub 1) approximately 1.7(+0.6/-0.5) and eta(sub 2) approximately -5.9(+5.7/-0.1) for GRBs above and below a break point of z(sub 1) approximately 6.8(+2.8/-3.2). This methodology is able to improve upon earlier studies by more accurately modeling Swift detection and using this for fully Bayesian model fitting. The code used in this is analysis is publicly available online.

gamma rays: general↗

Global variation of the para hydrogen fraction in Jupiter's atmosphere and implications for dynamics on the outer planets

A detailed analysis of the Voyager infrared spectrometer measurements on Jupiter's atmosphere is presented, and possible implications of para hydrogen disequilibrium for the energetics and dynamics of that atmosphere are examined. The method of data analysis is described, and results for the large scale latitude variation of the para hydrogen fraction are presented. The Jovian results show pronounced latitude variation, and are compared with other parameters including wind fields, thermal structure, and various indicators of atmospheric clouds. The problem of equilibration rate is reexamined, and it is concluded that on Jupiter the equilibration time is longer than the radiative time constant at the level of emission to space, but that this inequality reverses at greater depths. A model for the interaction of fluid motions with the ortho-para conversion process is presented, and a consistent mixing length theory for the reacting ortho-para mixture is developed. Several implications of the Jovian data for atmospheric energetics and stability on the outer planets are presented.

Conrath, B. J.↗

Development and applications of single particle orientation and rotational tracking in dynamic systems

The goal of this study is to help with future data analysis and experiment designs in rotational dynamics research using DIC-based SPORT technique. Most of the current studies using DIC-based SPORT techniques are technical demonstrations. Understanding the mechanisms behind the observed rotational behaviors of the imaging probes should be the focus of the future SPORT studies. More efforts are still needed in the development of new imaging probes, particle tracking methods, instrumentations, and advanced data analysis methods to further extend the potential of DIC-based SPORT technique.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Delving into the depths of NGC 3783 with XRISM II. Cross-calibration of X-ray instruments used in the large, multi-mission observational campaign

Context. Accurate X-ray spectroscopic measurements are fundamental for deriving basic physical parameters of the most abundant baryon components in the Universe. The plethora of X-ray observatories currently operational enables a panchromatic view of the high-energy emission of celestial sources. However, uncertainties in the energy-dependent calibration of the instrument transfer functions (e.g. the effective area, energy redistribution, or gain) can limit - and historically, did limit - the accuracy of X-ray spectroscopic measurements. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign.

Active Galactic Nuclei, individual: NGC 3783↗

A Search for Kilonovae in the Dark Energy Survey

The coalescence of a binary neutron star pair is expected to produce gravitational waves (GW) and electromagnetic radiation, both of which may be detectable with currently available instruments. We describe a search for a predicted r-process optical transient from these mergers, dubbed the “kilonova” (KN), using griz broadband data from the Dark Energy Survey Supernova Program (DES-SN). Some models predict KNe to be redder, shorter-lived, and dimmer than supernovae (SNe), but the event rate of KNe is poorly constrained. We simulate KN and SN light curves with the Monte-Carlo simulation code SNANA to optimize selection requirements, determine search efficiency, and predict SN backgrounds. Our analysis of the first two seasons of DES-SN data results in 0 events, and is consistent with our prediction of 1.1 ± 0.2 background events based on simulations of SNe. From our prediction, there is a 33% chance of finding 0 events in the data. Assuming no underlying galaxy flux, our search sets 90% upper limits on the KN volumetric rate of 1.0 ×10{sup 7} Gpc{sup −3} yr{sup −1} for the dimmest KN model we consider (peak i-band absolute magnitude M{sub i}=−11.4 mag) and 2.4 ×10{sup 4} Gpc{sup −3} yr{sup −1} for the brightest (M{sub i}=−16.2 mag). Accounting for anomalous subtraction artifacts on bright galaxies, these limits are ∼3 times higher. This analysis is the first untriggered optical KN search and informs selection requirements and strategies for future KN searches. Our upper limits on the KN rate are consistent with those measured by GW and gamma-ray burst searches.

79 ASTRONOMY AND ASTROPHYSICS↗

Combined use of computational chemistry and chemoinformatics methods for chemical discovery

Data analysis on numerical data by the computational chemistry calculations is carried out to obtain knowledge information of molecules. A molecular database is developed to systematically store chemical, electronic-structure, and knowledge-based information. The database is used to find molecules related to a keyword of “cancer”. Then the electronic-structure calculations are performed to quantitatively evaluate quantum chemical similarity of the molecules. Among the 377 compounds registered in the database, 24 molecules are found to be “cancer”-related. This set of molecules includes both carcinogens and anticancer drugs. The quantum chemical similarity analysis, which is carried out by using numerical results of the density-functional theory calculations, shows that, when some energy spectra are referred to, carcinogens are reasonably distinguished from the anticancer drugs. Therefore these spectral properties are considered of as important measures for classification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of beating parameters in human induced pluripotent stem cells enables quantitative in vitro screening for cardiotoxicity

Human induced pluripotent stem cell (iPSC)-derived cardiomyocytes show promise for screening during early drug development. Here, we tested a hypothesis that in vitro assessment of multiple cardiomyocyte physiological parameters enables predictive and mechanistically-interpretable evaluation of cardiotoxicity in a high-throughput format. Human iPSC-derived cardiomyocytes were exposed for 30 min or 24 h to 131 drugs, positive (107) and negative (24) for in vivo cardiotoxicity, in up to 6 concentrations (3 nM to 30 uM) in 384-well plates. Fast kinetic imaging was used to monitor changes in cardiomyocyte function using intracellular Ca{sup 2+} flux readouts synchronous with beating, and cell viability. A number of physiological parameters of cardiomyocyte beating, such as beat rate, peak shape (amplitude, width, raise, decay, etc.) and regularity were collected using automated data analysis. Concentration–response profiles were evaluated using logistic modeling to derive a benchmark concentration (BMC) point-of-departure value, based on one standard deviation departure from the estimated baseline in vehicle (0.3% dimethyl sulfoxide)-treated cells. BMC values were used for cardiotoxicity classification and ranking of compounds. Beat rate and several peak shape parameters were found to be good predictors, while cell viability had poor classification accuracy. In addition, we applied the Toxicological Prioritization Index (ToxPi) approach to integrate and display data across many collected parameters, to derive “cardiosafety” ranking of tested compounds. Multi-parameter screening of beating profiles allows for cardiotoxicity risk assessment and identification of specific patterns defining mechanism-specific effects. These data and analysis methods may be used widely for compound screening and early safety evaluation in drug development. - Highlights: • Induced pluripotent stem cell-derived cardiomyocytes are promising in vitro models. • We tested if evaluation of cardiotoxicity is possible in a high-throughput format. • The assay shows benefits of automated data integration across multiple parameters. • Quantitative assessment of concentration–response is possible using iPSCs. • Multi-parametric screening allows for cardiotoxicity risk assessment.

60 APPLIED LIFE SCIENCES↗

Implications of z ~ 6 Quasar Proximity Zones for the Epoch of Reionization and Quasar Lifetimes

In this paper, we study quasar proximity zones in the redshift range $5.77\leqslant z\leqslant 6.54$ by homogeneously analyzing 34 medium-resolution spectra, encompassing both archival and newly obtained data, and exploiting recently updated systemic redshift and magnitude measurements. Whereas previous studies found strong evolution of proximity zone sizes with redshift and argued that this provides evidence for a rapidly evolving intergalactic medium (IGM) neutral fraction during reionization, we measure a much shallower trend $\propto {(1+z)}^{-1.44}$. We compare our measured proximity zone sizes to predictions from hydrodynamical simulations post-processed with one-dimensional radiative transfer and find good agreement between observations and theory, irrespective of the ionization state of the ambient IGM. This insensitivity to IGM ionization state has been previously noted, and results from the fact that the definition of proximity zone size as the first drop of the smoothed quasar spectrum below the 10% flux transmission level probes locations where the ionizing radiation from the quasar is an order of magnitude larger than the expected ultraviolet ionizing background that sets the neutral fraction of the IGM. Our analysis also uncovered three objects with exceptionally small proximity zones (two have ${R}_{p}\lt 1$ proper Mpc), which constitute outliers from the observed distribution and are challenging to explain with our radiative transfer simulations. Finally, we consider various explanations for their origin, such as strong absorption line systems associated with the quasar or patchy reionization, but find that the most compelling scenario is that these quasars have been shining for ≲10 5 years.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of point spread function higher moments error on weak gravitational lensing – II. A comprehensive study

ABSTRACT Weak lensing is one of the most powerful probes for dark matter and dark energy science, although it faces increasing challenges in controlling systematic uncertainties as the statistical errors become smaller. The point spread function (PSF) needs to be precisely modeled to avoid systematic error on the weak lensing measurements. The weak lensing biases induced by errors in the PSF model second moments, i.e. its size and shape, are well-studied. However, Zhang et al. showed that errors in the higher moments of the PSF may also be a significant source of systematics for upcoming weak lensing surveys. Therefore, this work comprehensively investigate the modelling quality of PSF moments from the 3rd to 6th order, and propagate the PSFEx higher moments modelling error in the HSC survey data set to the weak lensing shear–shear correlation functions and their cosmological analyses. The overall multiplicative shear bias associated with errors in PSF higher moments can cause an ∼0.1σ shift on the cosmological parameters for LSST Y10, while the associated additive biases can induce 1σ uncertainties in cosmology parameter inference for LSST Y10, if not accounted. We compare the PSFEx model with PSF in Full FOV, and find similar performance in modelling the PSF higher moments. We conclude that PSF higher moment errors of the future PSF models should be reduced from those in current methods, otherwise needed to be explicitly modeled in the weak lensing analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Photometric redshift estimation with convolutional neural networks and galaxy images: Case study of resolving biases in data-driven methods

Deep-learning models have been increasingly exploited in astrophysical studies, but these data-driven algorithms are prone to producing biased outputs that are detrimental for subsequent analyses. In this work, we investigate two main forms of biases: class-dependent residuals, and mode collapse. We do this in a case study, in which we estimate photometric redshift as a classification problem using convolutional neural networks (CNNs) trained with galaxy images and associated spectroscopic redshifts. We focus on point estimates and propose a set of consecutive steps for resolving the two biases based on CNN models, involving representation learning with multichannel outputs, balancing the training data, and leveraging soft labels. The residuals can be viewed as a function of spectroscopic redshift or photometric redshift, and the biases with respect to these two definitions are incompatible and should be treated individually. We suggest that a prerequisite for resolving biases in photometric space is resolving biases in spectroscopic space. Experiments show that our methods can better control biases than benchmark methods, and they are robust in various implementing and training conditions with high-quality data. Our methods hold promises for future cosmological surveys that require a good constraint of biases, and they may be applied to regression problems and other studies that make use of data-driven models. Nonetheless, the bias-variance tradeoff and the requirement of sufficient statistics suggest that we need better methods and optimized data usage strategies.

79 ASTRONOMY AND ASTROPHYSICS↗

The GLAS physical inversion method for analysis of TIROS N data

The Goddard Laboratory for Atmospheric Sciences approach to temperature sounding from satellite observations is fundamentally different from that of NESS in that heavy reliance is placed on the ability to model accurately the instrumental response to atmospheric and surface conditions, while no use is made of statistical relationships between satellite observations and atmospheric temperature profiles. The method involves starting with a guess set of atmospheric and surface conditions from which expected brightness temperatures for the satellite observations are computed. Then, iterative relaxation of atmospheric and surface conditions is performed according to the difference between observed and computed brightness temperatures until sufficient agreement is reached. In the absence of sufficient agreement, no retrieval is produced for that location.

Susskind, J.↗

Efficient analysis routines for single and double peaked Type 2 AGN spectra

Driven by the imminent need to rapidly process and classify millions of AGN spectra drawn from next generation astronomical facilities, we present a spectral fitting routine for Type 2 AGN spectra optimized for high volume processing, using the quasar spectral fitting library (qsfit). We analyse an optically selected sample of 813 luminous Type 2 AGN spectra at z < 0.83 from the Sloan Digital Sky Survey (SDSS) to qualify its performance. We report a median narrow line H α/H β Balmer decrement of 4.5 ± 0.8, alluding to the presence of dust in the narrow line region (NLR). We publish a specialized QSFIT fitting routine for high signal-to-noise ratio spectra and general fitting routine for double peaked Type 2 AGN spectra applied on a subsample of 45 spectra from our parent sample. We report a median red and blue peak velocity separation of 390 ± 60 kms −1 . No trend is found for red or blue peaks to exhibit systematically different luminosity or ionization properties. Emission line diagnostics show that the double peaks in all sources are illuminated by an AGN-powered ionizing continuum. Finally, we examine the morphology of host galaxies of our double peaked sample. We find double peaked Type 2 AGN reside in merging systems at a comparable frequency to single peaked AGN. This suggests that the double peaked AGN phenomenon is likely to have a bi-conical outflow origin in the majority of cases. We publicly release the code used for spectral analysis and produced catalogues used in this work.

79 ASTRONOMY AND ASTROPHYSICS↗

MALDI Orbitrap Mass Spectrometry Profiling of Dysregulated Sulfoglycosphingolipids in Renal Cell Carcinoma Tissues

Matrix-assisted laser desorption/ionization coupled with Orbitrap mass spectrometry (MALDI-Orbitrap-MS) is used for the clinical study of patients with renal cell carcinoma (RCC), as the most common type of kidney cancer. Significant changes in sulfoglycosphingolipid abundances between tumor and autologous normal kidney tissues are observed. First, sulfoglycosphingolipid species in studied RCC samples are identified using high mass accuracy full scan and tandem mass spectra. Subsequently, optimization, method validation, and statistical evaluation of MALDI-MS data for 158 tissues of 80 patients are discussed. More than 120 sulfoglycosphingolipids containing one to five hexosyl units are identified in human RCC samples based on the systematic study of their fragmentation behavior. Many of them are recorded here for the first time. Multivariate data analysis (MDA) methods, i.e., unsupervised principal component analysis (PCA) and supervised orthogonal partial least square discriminant analysis (OPLS-DA), are used for the visualization of differences between normal and tumor samples to reveal the most up- and downregulated lipids in tumor tissues. Obtained results are closely correlated with MALDI mass spectrometry imaging (MSI) and histologic staining. Important steps of the present MALDI-Orbitrap-MS approach are also discussed, such as the selection of best matrix, correct normalization, validation for semiquantitative study, and problems with possible isobaric interferences on closed masses in full scan mass spectra. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive microrheology of normal and cancer cells after ML7 treatment by atomic force microscopy

Mechanical properties of living cancer and normal thyroidal cells were investigated by atomic force microscopy (AFM). Cell mechanics was compared before and after treatment with ML7, which is known to reduce myosin activity and induce softening of cell structures. We recorded force curves with extended dwell time of 6 seconds in contact at maximum forces from 500 pN to 1 nN. Data were analyzed within different frameworks: Hertz fit was applied in order to evaluate differences in Young’s moduli among cell types and conditions, while the fluctuations of the cantilever in contact with cells were analyzed with both conventional algorithms (probability density function and power spectral density) and multifractal detrended fluctuation analysis (MF-DFA). We found that cancer cells were softer than normal cells and ML7 had a substantial softening effect on normal cells, but only a marginal one on cancer cells. Moreover, we observed that all recorded signals for normal and cancer cells were monofractal with small differences between their scaling parameters. Finally, the applicability of wavelet-based methods of data analysis for the discrimination of different cell types is discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prognostics and Health Management in Nuclear Power Plants: An Updated Method-Centric Review With Special Focus on Data-Driven Methods

In a carbon-constrained world, future uses of nuclear power technologies can contribute to climate change mitigation as the installed electricity generating capacity and range of applications could be much greater and more diverse than with the current plants. To preserve the nuclear industry competitiveness in the global energy market, prognostics and health management (PHM) of plant assets is expected to be important for supporting and sustaining improvements in the economics associated with operating nuclear power plants (NPPs) while maintaining their high availability. Of interest are long-term operation of the legacy fleet to 80 years through subsequent license renewals and economic operation of new builds of either light water reactors or advanced reactor designs. Recent advances in data-driven analysis methods—largely represented by those in artificial intelligence and machine learning—have enhanced applications ranging from robust anomaly detection to automated control and autonomous operation of complex systems. The NPP equipment PHM is one area where the application of these algorithmic advances can significantly improve the ability to perform asset management. This paper provides an updated method-centric review of the full PHM suite in NPPs focusing on data-driven methods and advances since the last major survey article was published in 2015. The main approaches and the state of practice are described, including those for the tasks of data acquisition, condition monitoring, diagnostics, prognostics, and planning and decision-making. Research advances in non-nuclear power applications are also included to assess findings that may be applicable to the nuclear industry, along with the opportunities and challenges when adapting these developments to NPPs. Finally, this paper identifies key research needs in regard to data availability and quality, verification and validation, and uncertainty quantification.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Results of the asteroid-meteoroid particle experiment on Pioneer 11

The Asteroid-Meteoroid Detector, an electro-optical instrument that detects and measures particles in space by sensing the sunlight reflected from them, is part of the payload of both the Pioneer 10 and 11 spacecraft. The Pioneer 11 instrument is essentially identical to that on Pioneer 10, with some minor modifications. Reduction of the Pioneer 11 data was complicated by the failure of one of the four sensor channels at about 1.1 AU from the sun. Detailed analysis yielded 51 events between 1.0 and 3.5 AU, which were used to determine the particle concentration distribution in that region of space. Weighted curve-fitting of the results shows agreement with the concentrations derived from Pioneer 10 to within about a factor of two. As with the Pioneer 10 results, the exponent of the size dependency varies from about -1.7 for 100-micron radius particles to about -3.2 for 10-cm bodies. The instrument, its operation, and the method of data analysis are reviewed.

Soberman, R. K.↗