Search NASA⌕ Search

SEARCH · Search NASA

Results for “MicroED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Monitoring micro-crack healing in an engineered cementitious composite using the environmental scanning electron microscope

Environmental Scanning Electron Microscopy (ESEM) is used to study the origin of micro-crack healing in an Engineered Cementitious Composite (ECC). ESEM images were acquired from ECC specimens cut from pre-cracked, dog-bone samples which then subjected to submerged curing followed by exposure to the natural environment. The mineralogical and chemical compositions of the healing products were determined using the EDX facility in the ESEM. It is shown that the precipitation of calcium carbonate is the main contributor to micro-crack healing at the crack mouth. The healing products initially appeared in an angular rhombohedral morphology which then underwent a discernable transformation in size, shape and surface texture, from relatively flat and smooth to irregular and rough, resembling the texture of the original surface areas surrounding the micro-cracks. It is also shown that exposure to the natural environment, involving intermittent wetting/drying cycles, promotes additional crystal growth, which indicates enhanced self-healing capability in this environment. - Highlights: •ESEM with EDX used to characterize the origin of micro-crack healing in an ECC •Evolution of healing precipitates studied at three specific locations over four weeks •Specimens exposed to laboratory environment, followed by the natural environment •Calcium carbonate is the main contributor to crack healing at the crack mouth. •Outdoor exposure involving intermittent rain promotes additional crystal growth.

36 MATERIALS SCIENCE↗

Effect of Nb micro-alloying on microstructure and properties of thermo-mechanically processed high carbon pearlitic steel

Highlights: • Effect of Nb micro-alloying on high carbon steels has been established. • Fine and degenerated pearlite with fine PAGS is achieved due to Nb micro-alloying. • AFM study indicates true interlamellar spacing which conforms well to TEM study. • Hardness and yield strength have been obviously improved with the addition of Nb. - Abstract: Two C-Mn-Si steels with and without Nb micro-alloying are selected in the present study. Both these high carbon steels have been thermo-mechanically processed using Gleeble 3800 simulator. Optical microscope (OM), scanning electron microscope (SEM), transmission electron microscope (TEM), atomic force microscope (AFM) were utilised for microstructural characterisation. The austenitising temperature was varied from 1150 °C to 1200 °C followed by hot compression and subjected to free cooling to evaluate the influence of austenite grain size on transformed microstructure and mechanical properties. It is evident that higher austenite grain size is obtained for both types of steels subjected to higher austenitising temperature. The refinement of pearlite interlamellar spacing (<0.20 μm) with degenerated morphology as well as finer prior austenite grain size (<40 μm) is found to be more prominent for Nb micro-alloyed sample. The average hardness values of both the steels are higher for the specimens, treated at a higher austenitising temperature which is attributed to finer interlamellar spacing. Finally, the correlation between the evolving microstructure and resulting mechanical properties (hardness and yield strength) has been made.

36 MATERIALS SCIENCE↗

Synthesis and upconversion emission of rare earth-doped olive-like YF{sub 3} micro-particles

The olive-like YF{sub 3} micro-particles were fabricated via a two-step route. The precursor NH{sub 4}Y{sub 3}F{sub 10} nano-cages sized 8 nm with hollow interiors were first synthesized in a solid reaction at room temperature. In the course of subsequent hydrothermal treating, the unstable NH{sub 4}Y{sub 3}F{sub 10} nano-cages were decomposed, resulted in the formation of Y(OH){sub 1.63}F{sub 1.37} micro-tubes. Prolonging the hydrothermal reaction induced the further decomposition of Y(OH){sub 1.63}F{sub 1.37} to produce YF{sub 3} nano-crystals, which then aggregated together forming the final olive-like YF{sub 3} micro-particles. For the Er{sup 3+}/Yb{sup 3+} co-doped olive-like YF{sub 3} micro-particles, intense visible upconversion emissions were measured under 976 nm excitation owing to the partition of rare earth ions in the lattice, indicating this material a promising luminescent host.

36 MATERIALS SCIENCE↗

Angioarchitectural Changes in Subacute Cerebral Venous Thrombosis. A Synchrotron-based Micro- and Nano-CT Study

It is well known that recanalization of thrombosed cerebral sinuses occurs early but without marked influence on the long-term outcome and on final venous infarct volume on magnetic resonance imaging. To better understand the possible microvascular mechanisms behind these clinical observations, we evaluated the sequels of subacute superior sagittal sinus (SSS) thrombosis in rats using micro- and nano-CT imaging of the same specimen to provide large volume and high resolution CT image data respectively. SSS thrombosis was induced in 11 animals which were euthanized after 6 h (n = 4) or 6 weeks (n = 7). Eight sham-operated rats served as controls. After infusion of contrast into the vasculature of the brains, these were isolated and scanned using micro-, nano-, and synchrotron-based micro-CT ((8 {mu}m{sup 3}), (900 nm){sup 3}, and (1.9 {mu}m{sup 3}) voxel sizes). The cross-sectional area of the superior sagittal sinus, microvessels and cortical veins were quantified. Tissue sections were stained against VEGF antigen. Immunohistochemistry was confirmed using quantitative rtPCR. SSS thrombosis led to a congestion of the bridging veins after 6 h. After 6 weeks, a network of small vessels surrounding the occluded SSS was present with concurrent return towards the diameter of the draining bridging veins of controls. This microvascular network connected to cortical veins as demonstrated by nano- and synchrotron-based micro-CT. Also the volume fraction and number of cortical veins increased significantly. Immunohistochemistry in the region of the microsvascular network demonstrated a strong immunoreactivity against VEGF, confirmed by rtPCR. The sequel of subacute SSS thrombosis induced a network of microvessels ('venogenesis') draining the bridging veins. Also the volume fraction of cortical veins increased significantly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scalable and Direct Growth of Graphene Micro Ribbons on Dielectric Substrates

Here we report on a scalable and direct growth of graphene micro ribbons on SiO2 dielectric substrates using a low temperature chemical vapor deposition. Due to the fast annealing at low temperature and dewetting of Ni, continuous few-layer graphene micro ribbons grow directly on bare dielectric substrates through Ni assisted catalytic decomposition of hydrocarbon precursors. These high quality graphene micro ribbons exhibit low sheet resistance of ,700 V 22100 V, high on/off current ratio of ,3, and high carrier mobility of ,655 cm2 V21 s21 at room temperature, all of which have shown significant improvement over other lithography patterned CVD graphene micro ribbons. This direct approach can in principle form graphene ribbons of any arbitrary sizes and geometries. It allows for a feasible methodology towards better integration with semiconductor materials for interconnect electronics and scalable production for graphene based electronic and optoelectronic applications where the electrical gating is the key enabling factor.

SYNTHESIS OF GRAPHENE↗

Laboratory-based characterization of plutonium in soil particles using micro-XRF and 3D confocal XRF

The investigation of plutonium (Pu) in a soil matrix is of interest in safeguards, nuclear forensics, and environmental remediation activities. The elemental composition of two plutonium contaminated soil particles was characterized nondestructively using a pair of micro X-ray fluorescence spectrometry (micro-XRF) techniques including high resolution X-ray (hiRX) and 3D confocal XRF. The three dimensional elemental imaging capability of confocal XRF permitted the identification two distinct Pu particles within the samples: one external to the Ferich soil matrix and another co-located with Cu within the soil matrix. The size and morphology of the particles was assessed with X-ray transmission microscopy and micro X-ray computed tomography (micro-CT) providing complementary morphological information. Limits of detection for a 30 μm Pu particle are <10 ng for each of the XRF techniques. Ultimately, this study highlights the capability for lab-based, nondestructive, spatially resolved characterization of heterogeneous matrices on the micrometer scale with nanogram sensitivity.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Safely probing the chemistry of Chernobyl nuclear fuel using micro-focus X-ray analysis

Detailed chemical analysis of the solidified molten fuel still residing in the stricken Chernobyl reactor unit 4 are inferred using multi-modal micro-focus X-ray analysis of a low-radioactivity proxy. A fascinating mixture of molten UO 2 , nuclear fuel cladding, concrete, stainless steel and other nuclear reactor components, these materials behaved like lava, solidifying to form a complex, highly radioactive glass-ceramic. Using element-specific chemical probes (micro-X-ray fluorescence and X-ray absorption spectroscopy), coupled with micro-diffraction analysis, the crystalline phase assemblage of simulants of these heterogeneous materials was established, which included “chernobylite” and a range of compositions in the (U 1-x Zr x )O 2 solid solution. Novel insight to nuclear accident fuel chemistry was obtained by establishing the oxidation state and local coordination of uranium not only in these crystalline phases, but uniquely in the amorphous fraction of the material, which varied depending on the history of the nuclear lava as it flowed through the reactor. This study demonstrates that micro-focus X-ray analysis of very small fractions of material can yield rich chemical information, which can be applied to nuclear-melt down materials to aid decommissioning and nuclear fuel management at nuclear accident sites.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal Stress Behavior of Micro- and Nano-Size Aluminum Films

In-situ observation of thermal stresses in thin films deposited on silicon substrate was made by X-ray and synchrotron radiation. Specimens prepared in this experiment were micro- and nano-size thin aluminum films with and without passivation film. The thickness of the film was 1 micrometer for micro-size films and 10, 20 and 50 nanometer for nano-size films. The stress measurement in micro-size films was made by X-ray radiation whereas the measurement of nano-size films was made by synchrotron radiation. Residual stress measurement revealed tensile stresses in all as-deposited films. Thermal stresses were measured in a series of heating- and cooling-stage. Thermal stress behavior of micro-size films revealed hysteresis loop during a heating and cooling process. The width of a hysteresis loop was larger in passivated film that unpassivated film. No hysteresis loops were observed in nano-size films with SiO{sub 2} passivation. Strengthning mechanism in thin films was discussed on a passivation film and a film thickness.

36 MATERIALS SCIENCE↗

Efficiency of Micro-fine Cement Grouting in Liquefiable Sand

In the presence of strong ground motion, liquefaction hazards are likely to occur in saturated cohesion-less soils. The risk of liquefaction and subsequent deformation can be reduced by various ground improvement methods including the cement grouting technique. The grouting method was proposed for non-disruptive mitigation of liquefaction risk at developed sites susceptible to liquefaction. In this research, a large-scale experiment was developed for assessment of micro-fine cement grouting effect on strength behavior and liquefaction potential of loose sand. Loose sand samples treated with micro-fine grout in multidirectional experimental model, were tested under cyclic and monotonic triaxial loading to investigate the influence of micro-fine grout on the deformation properties and pore pressure response. The behavior of pure sand was compared with the behavior of sand grouted with a micro-fine cement grout. The test results were shown that cement grouting with low concentrations significantly decreased the liquefaction potential of loose sand and related ground deformation.

58 GEOSCIENCES↗

Evaluation of Biomaterials Using Micro-Computerized Tomography

Micro-computed tomography or Micro-CT is a high resolution, non-invasive, x-ray scanning technique that allows precise three-dimensional imaging and quantification of micro-architectural and structural parameters of objects. Tomographic reconstruction is based on a cone-beam convolution-back-projection algorithm. Micro-architectural and structural parameters such as porosity, surface area to volume ratio, interconnectivity, pore size, wall thickness, anisotropy and cross-section area of biomaterials and bio-specimens such as trabecular bone, polymer scaffold, bio-ceramics and dental restorative were evaluated through imaging and computer aided manipulation of the object scan data sets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of transient electron energy in a micro dielectric barrier discharge for a high performance plasma display panel

We present here analysis of electron energy of a micro dielectric barrier discharge (micro-DBD) for alternating-current plasma display panel (ac-PDP) with Ne/Xe gas mixture by using the optical emission spectroscopy (OES). The OES method is quite useful to evaluate a variety of electron energy in a high pressure DBD ignited in a PDP small cell. Experiment shows that the ratio of Ne emission intensity (I{sub Ne}) relative to Xe emission intensity (I{sub Xe}) drastically decreases with time. This temporal profile is well consistent with dynamic behavior of electron temperature in a micro-DBD, calculated in one-dimensional fluid model. I{sub Ne}/I{sub Xe} also decreases with an increase in Xe gas pressure and a decrease in applied voltage especially in the initial stage of discharge, and these reflect the basic features of electron temperature in a micro-DBD. The influences of plasma parameters such as electron temperature on luminous efficacy are also theoretically analyzed using one-dimensional fluid model. The low electron temperature, which is attained at high Xe gas pressure, realizes the efficient Xe excitation for vacuum ultraviolet radiation. The high Xe-pressure condition also induces the rapid growth of discharge and consequent high plasma density, resulting in high electron heating efficiency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Study of Local Micro-forming for Bi-HTS

The Bi-HTS (BSCCO high temperature superconductor) tape now has become the product in an industrial way, which has been available to apply in electric and electron fields. The main way to manufacture Bi-HTS tape is to use the technique of oxide powder in silver tube (OPIT), which involves the multi-step drawing and rolling with plastic deformation, which obviously belongs to a type of the micro-forming in macro-scale processing. There are two main characteristics founded: (a) contact and friction between silver and BSCCO surfaces, (b) interface between two materials. A series of micro-tensile experiments of silver foil with thicknesses of 0.03, 0.06 and 0.1 mm are designed to investigate the behaviors of silver with various scale of sizes. And the surface topography measurements have been carried out to analyze the changes in surface topography. Based upon experiments, some topics are researched which are referred to inhomogeneous, local effect, size effect, grain and micro-structure affecting, surface roughness, long-distance sausage phenomenon. Further the local breakdown of silver by Bi-HTS powder during process is analyzed through failure criterion. The results of this work will bring out an important exploration value to the theory and computation of micro-forming.

36 MATERIALS SCIENCE↗

An Investigation of Machining Characteristics in Micro-scale Milling Process

In this paper, an analytical solution of micro-scale milling process is presented in order to suggest available machining conditions. The size effect should be considered to determine cutting characteristics in micro-scale cutting. The feed per tooth is the most dominant cutting parameter related to the size effect in micro-scale milling process. In order to determine the feed per tooth at which chips can be formed, the finite element method is used. The finite element method is employed by utilizing the Johnson-Cook (JC) model as a constitutive model of work material flow stress. Machining experiments are performed to validate the simulation results by using a micro-machining stage. The validation is conducted by observing cutting force signals from a cutting tool and the conditions of the machined surface of the workpiece.

36 MATERIALS SCIENCE↗

Image reconstruction from sparse data ion synchrotron-radiation-based micro-tomography.

Synchrotron-radiation-based microcomputed-tomography (SR-{micro}CT) is a powerful tool for yielding 3D structural information of high spatial and contrast resolution about a specimen preserved in its natural state. A large number of projection views are required currently for yielding SR-{micro}CT images by use of existing algorithms without significant artifacts. When a wet biological specimen is imaged, synchrotron x-ray radiation from a large number of projection views can result in significant structural deformation within the specimen. A possible approach to reducing imaging time and specimen deformation is to decrease the number of projection views. In the work, using reconstruction algorithms developed recently for medical computed tomography (CT), we investigate and demonstrate image reconstruction from sparse-view data acquired in SR-{micro}CT. Numerical results of our study suggest that images of practical value can be obtained from data acquired at a number of projection views significantly lower than those used currently in a typical SR-{micro}CT imaging experiment.

99 GENERAL AND MISCELLANEOUS↗

Effects of Process Parameters on Ultrasonic Micro-Hole Drilling in Glass and Ruby

Brittle materials such as ceramics, glasses and oxide single crystals find increasing applications in advanced micro-engineering products. Machining small features in such materials represents a manufacturing challenge. Ultrasonic drilling constitutes a promising technique for realizing simple micro-holes of high diameter-to-depth ratio. The process involves impacting abrasive particles in suspension in a liquid slurry between tool and work piece. Among the process performance criteria, the drilling time (productivity) is one of the most important quantities to evaluate the suitability of the process for industrial applications.This paper summarizes recent results pertaining to the ultrasonic micro-drilling process obtained with a semi-industrial 3-axis machine. The workpiece is vibrated at 40 kHz frequency with an amplitude of several micrometers. A voice-coil actuator and a control loop based on the drilling force impose the tool feed. In addition, the tool is rotated at a prescribed speed to improve the drilling speed as well as the hole geometry. Typically, a WC wire serves as tool to bore 200 {mu}m diameter micro-holes of 300 to 1,000 {mu}m depth in glass and ruby. The abrasive slurry contains B4C particles of 1 {mu}m to 5 {mu}m diameter in various concentrations.This paper discusses, on the basis of the experimental results, the influence of several parameters on the drilling time. First, the results show that the control strategy based on the drilling force allows to reach higher feed rates (avoiding tool breakage). Typically, a 8 um/s feed rate is achieved with glass and 0.9 {mu}m/s with ruby. Tool rotation, even for values as low as 50 rpm, increases productivity and improves holes geometry. Drilling with 1 {mu}m and 5 {mu}m B4C particles yields similar productivity results. Our future research will focus on using the presented results to develop a model that can serve to optimize the process for different applications.

36 MATERIALS SCIENCE↗

Experimental Investigation of the Reflection Mode Micro Laser Propulsion under Highly Frequent and Multi Pulse Laser

Micro laser propulsion used for some space tasks of micro-satellites are preferred to providing small thrust and high specific impulse while keeping power consumption low. Most previous work on micro laser propulsion are about transmission mode (T-mode) using a CW laser. In this article, a pulsed fiber laser is used to study the micro laser propulsion performance under reflection mode. Multi pulse (ranged from 100 to 2000) tests are conducted on a double base propellant with the vacuum less than 10 Pa. The laser frequency is 20 kHz and two kinds of instantaneous power density 4.77x10{sup 6} W/cm{sup 2} and 2.39x10{sup 7} W/cm{sup 2} are used. It is found that the momentum coupling coefficient C{sub m} and the mean thrust F increases with the increasing pulse numbers, which is different to the previous work. By adjusting the irradiation time T, it is easy to get a large mean thrust, up to mN. When the energy density is the same, C{sub m}, I{sub sp}, F and {eta} increase with the increasing power density. Also I{sub sp} and {eta} are very low, laser ablation is insufficiently under the current condition. 3D Morphology of the ablation hole is obtained by confocal microscope for the first time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental study of micro electrical discharge machining discharges

Micro electrical discharge machining ({mu}EDM) is an atmospheric-pressure plasma-assisted technology that uses point-to-plane discharges in liquid dielectrics to remove microscopic quantities of electrically conductive materials. In this work, an innovative {mu}EDM prototype machine was specifically designed and fabricated to produce and control single spark discharges, thus, resolving the typical limitations of (multi-discharge) commercial machines. The work analyses the type of discharge and the micro-plasma electron-density values obtained for 0.5-38 {mu}m gap sizes, 3-10 000 {mu}s pulse durations, 75-250 V low breakdown voltages, and 1-20 A discharge currents, using different combinations of metallic electrodes in oil and in water. Results allow fitting, for micro-scale and low voltages, an empirical law between the maximum gap-size for breakdown, the breakdown voltage, and the effective stress-time. The electron density n{sub e} is obtained by optical emission spectroscopy diagnostics of the H{sub {alpha}}-line Stark broadening (yielding n{sub e}{approx}10{sup 16}-10{sup 17} cm{sup -3}, i.e., ionization degrees of {approx}2 Multiplication-Sign 10{sup -5}-10{sup -4}) and by a semi-empirical resistive plasma model. The model uses the experimental values of several electrical and geometrical quantities, and of the gas pressure estimated as {approx}60 bar-2 kbar from measurements of the plasma mechanical action, obtained using a force sensor. The quantitative information of this phenomenological study can assist the optimization of this micro-fabrication technique.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detection of electromagnetic pulses produced by hypervelocity micro particle impact plasmas

Hypervelocity micro particles (mass < 1 ng), including meteoroids and space debris, routinely impact spacecraft and produce plasmas that are initially dense (∼10{sup 28} m{sup −3}), but rapidly expand into the surrounding vacuum. We report the detection of radio frequency (RF) emission associated with electromagnetic pulses (EMPs) from hypervelocity impacts of micro particles in ground-based experiments using micro particles that are 15 orders of magnitude less massive than previously observed. The EMP production is a stochastic process that is influenced by plasma turbulence such that the EMP detection rate that is strongly dependent on impact speed and on the electrical charge conditions at the impact surface. In particular, impacts of the fastest micro particles occurring under spacecraft charging conditions representative of high geomagnetic activity are the most likely to produce RF emission. This new phenomenon may provide a source for unexplained RF measurements on spacecraft charged to high potentials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗