Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Performing In Situ Closed-Cell Gas Reactions in the Transmission Electron Microscope

Gas reactions studied by in situ electron microscopy can be used to capture the real-time morphological and microchemical transformations of materials at length scales down to the atomic level. In situ closed-cell gas reaction (CCGR) studies performed using (scanning) transmission electron microscopy (STEM) can separate and identify localized dynamic reactions, which are extremely challenging to capture using other characterization techniques. For these experiments, we used a CCGR holder that utilizes microelectromechanical systems (MEMS)-based heating microchips (hereafter referred to as "E-chips"). The experimental protocol described here details the method for performing in situ gas reactions in dry and wet gases in an aberration-corrected STEM. This method finds relevance in many different materials systems, such as catalysis and high-temperature oxidation of structural materials at atmospheric pressure and in the presence of various gases with or without water vapor. Here, several sample preparation methods are described for various material form factors. During the reaction, mass spectra obtained with a residual gas analyzer (RGA) system with and without water vapor further validates gas exposure conditions during reactions. Integrating an RGA with an in situ CCGR-STEM system can, therefore, provide critical insight to correlate gas composition with the dynamic surface evolution of materials during reactions. In situ/operando studies using this approach allow for detailed investigation of the fundamental reaction mechanisms and kinetics that occur at specific environmental conditions (time, temperature, gas, pressure), in real-time, and at high spatial resolution.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High framerate and high dynamic range electron microscopy

Methods and systems for acquiring transmission electron microscope video data on a rolling-shutter detector at an enhanced frame rate and without temporal distortions are described. Also described are methods to enhance the dynamic range of image and diffraction data acquired using a transmission electron microscope. The disclosed methods and systems may also be applicable to photon detection and imaging systems.

Bloom, Ruth↗

Shear-Induced Gelation of Self-Yielding Active Networks

An enticing feature of active materials is the possibility of controlling macroscale rheological properties through the activity of the microscopic constituents. Using a unique combination of microscopy and rheology we study three dimensional microtubule-based active materials whose autonomous flows are powered by a continually rearranging connected network. We quantify the relationship between the microscopic dynamics and the bulk mechanical properties of these nonequilibrium networks. Experiments reveal a surprising nonmonotonic viscosity that strongly depends on the relative magnitude of the rate of internally generated activity and the externally applied shear. Here, a simple two-state mechanical model that accounts for both the solidlike and yielded fluidlike elements of the network accurately describes the rheological measurements.

36 MATERIALS SCIENCE↗

Wavelength-Dependent Differential Interference Contrast Microscopy: Selectively Imaging Nanoparticle Probes in Live Cells

Gold and silver nanoparticles display extraordinarily large apparent refractive indices near their plasmon resonance (PR) wavelengths. These nanoparticles show good contrast in a narrow spectral band but are poorly resolved at other wavelengths in differential interference contrast (DIC) microscopy. The wavelength dependence of DIC contrast of gold/silver nanoparticles is interpreted in terms of Mie's theory and DIC working principles. We further exploit this wavelength dependence by modifying a DIC microscope to enable simultaneous imaging at two wavelengths. We demonstrate that gold/silver nanoparticles immobilized on the same glass slides through hybridization can be differentiated and imaged separately. High-contrast, video-rate images of living cells can be recorded both with and without illuminating the gold nanoparticle probes, providing definitive probe identification. Dual-wavelength DIC microscopy thus presents a new approach to the simultaneous detection of multiple probes of interest for high-speed live-cell imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Air plasma effect on dental disinfection

A nonthermal low temperature air plasma jet is characterized and applied to study the plasma effects on oral pathogens and biofilms. Experiments were performed on samples of six defined microorganisms' cultures, including those of gram-positive bacteria and fungi, and on a cultivating biofilm sample of Streptococcus mutans UA159. The results show that the plasma jet creates a zone of microbial growth inhibition in each treated sample; the zone increases with the plasma treatment time and expands beyond the entire region directly exposed to the plasma jet. With 30s plasma treatment twice daily during 5 days of biofilm cultivation, its formation was inhibited. The viability of S. mutans cells in the treated biofilms dropped to below the measurable level and the killed bacterial cells concentrated to local regions as manifested by the fluorescence microscopy via the environmental scanning electron microscope. The emission spectroscopy of the jet indicates that its plasma effluent carries an abundance of reactive atomic oxygen, providing catalyst for the observed plasma effect.

60 APPLIED LIFE SCIENCES↗

U-10Mo Sample Preparation and Examination using Optical and Scanning Electron Microscopy

The purpose of this document is to provide guidelines to prepare specimens of uranium alloyed with 10 weight percent molybdenum (U-10Mo) for optical metallography and scanning electron microscopy. This document also provides instructions to set up an optical microscope and a scanning electron microscope to analyze U-10Mo specimens and to obtain the required information.

36 MATERIALS SCIENCE↗

U-10Mo Sample Preparation and Examination using Optical and Scanning Electron Microscopy

The purpose of this document is to provide guidelines to prepare specimens of uranium alloyed with 10 weight percent molybdenum (U-10Mo) for optical metallography and scanning electron microscopy. This document also provides instructions to set up an optical microscope and a scanning electron microscope to analyze U-10Mo specimens and to obtain the required information.

36 MATERIALS SCIENCE↗

Tribological Behavior of Electrochemically Etched AISI 316 Stainless Steel with a Textured Surface

In this work, AISI 316 stainless steel (316 SS) was electrochemically etched in four NaCl solutions (10, 15, 20, and 25 wt.%) to form textured surfaces. Surface morphologies, three-dimensional surface topographies, and surface profiles of the textured 316 SS samples were obtained by scanning electron microscopy (SEM) and laser scanning confocal microscope (LSCM). Sliding friction tests of the textured 316 SS samples were conducted in air and under grease lubrication. The results suggested that the variable degrees of microtextured surfaces after electrochemical etching in 10, 15, and 20 wt.% NaCl solutions. The 316 SS samples etched in 15 and 20 wt.% NaCl solutions showed more promising tribological performance than other samples, as reflected by their friction coefficients, mass loss per unit distance traveled (mg/m), and wear morphologies.

36 MATERIALS SCIENCE↗

Cryo diffraction microscopy: Ice conditions and finite supports

Using a signal-to-noise ratio estimation based on correlations between multiple simulated images, we compare the dose efficiency of two soft x-ray imaging systems: incoherent brightfield imaging using zone plate optics in a transmission x-ray microscope (TXM), and x-ray diffraction microscopy (XDM) where an image is reconstructed from the far-field coherent diffraction pattern. In XDM one must computationally phase weak diffraction signals; in TXM one suffers signal losses due to the finite numerical aperture and efficiency of the optics. In simulations with objects representing isolated cells such as yeast, we find that XDM has the potential for delivering equivalent resolution images using fewer photons. This can be an important advantage for studying radiation-sensitive biological and soft matter specimens.

36 MATERIALS SCIENCE↗

Electron knock-on damage in hexagonal boron nitride monolayers

We combine first-principles molecular-dynamics simulations with high-resolution transmission electron microscopy experiments to draw a detailed microscopic picture of irradiation effects in hexagonal boron nitride (h-BN) monolayers. We determine the displacement threshold energies for boron and nitrogen atoms in h-BN, which differ significantly from the tight-binding estimates found in the literature and remove ambiguity from the interpretation of the experimental results. We further develop a kinetic Monte Carlo model which allows to extend the simulations to macroscopic time scales and make a direct comparison between theory and experiments. Our results provide a comprehensive picture of the response of h-BN nanostructures to electron irradiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synthesis, characterization and properties of carbon nanotubes microspheres from pyrolysis of polypropylene and maleated polypropylene

Microspheres assembled from carbon nanotubes (MCNTs), with the diameters ranging from 5.5 to 7.5 {mu}m, were synthesized by means of pyrolysis of polypropylene and maleated polypropylene in an autoclave. The characterization of structure and morphology was carried out by X-ray diffractometer (XRD), field-emission scanning electron microscopy (FESEM), (high resolution) transmission electron microscope [(HR)TEM)], selected-area electron diffraction (SAED) and Raman spectrum. As a typical morphology, the possible growth process of MCNTs was also investigated and discussed. The results of nitrogen adsorption-desorption indicate that the Brunauer-Emett-Teller (BET) surface area (140.6 m{sup 2}/g) of the MCNTs obtained at 600 {sup o}C is about twice as that (74.5 m{sup 2}/g) of carbon nanotubes obtained at 700 {sup o}C. The results of catalytic experiment show that MCNTs based catalyst has higher catalytic activity than the carbon nanotubes based catalyst for the preparation of methanol and dimethoxy-ethane by oxidation of dimethyl ether.

36 MATERIALS SCIENCE↗

Optical modeling of Fresnel zoneplate microscopes

Defect free masks remain one of the most significant challenges facing the commercialization of extreme ultraviolet (EUV) lithography. Progress on this front requires high-performance wavelength-specific metrology of EUV masks, including high-resolution and aerial-image microscopy performed near the 13.5 nm wavelength. Arguably the most cost-effective and rapid path to proliferating this capability is through the development of Fresnel zoneplate-based microscopes. Given the relative obscurity of such systems, however, modeling tools are not necessarily optimized to deal with them and their imaging properties are poorly understood. Here we present a modeling methodology to analyze zoneplate microscopes based on commercially available optical modeling software and use the technique to investigate the imaging performance of an off-axis EUV microscope design. The modeling predicts that superior performance can be achieved by tilting the zoneplate, making it perpendicular to the chief ray at the center of the field, while designing the zoneplate to explicitly work in that tilted plane. Although the examples presented here are in the realm of EUV mask inspection, the methods described and analysis results are broadly applicable to zoneplate microscopes in general, including full-field soft-x-ray microscopes routinely used in the synchrotron community.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Intercalation of Nanopolyaniline with Nanobentonite and Manganese Oxide Nanoparticles as a Novel Nanocomposite to Remediate Cobalt/Zinc and Their Radioactive Nuclides {sup 60}Co/{sup 65}Zn

A novel nanocomposite based on the combination of nanobentonite with nanopolyaniline and nanomanganese oxide (N-Bent–NPANI–NMn{sub 3}O{sub 4}) was synthesized and investigated to extract Co/Zn ions from water using batch technique and {sup 60}Co/{sup 65}Zn radionuclides from radioactive wastewater using column techniques. Characterization was established by High resolution-transmission electron microscopy (HR-TEM), Scanning electron microscope, X-ray diffraction (XRD), thermal gravimetric analysis (TGA) and Fourier transform infrared spectrophotometer. The image of HR-TEM indicated that the produced nanocomposite was ranged from 59.07 to 83.38 nm. Solution pH, time of reaction, amount of solid and metal concentration, all of these parameters were inspected and optimized as fundamental factors during the extraction process. The obtained results implied that the ideal conditions for extraction were pH 6 and 7, reaction time 10 and 20 min, for Co and Zn ions, respectively. The highest removal capacities were found 255.28 and 202.22 mg g{sup −1} for Co and Zn, respectively by using 5 mg nanocomposite. Excellent recoveries were obtained as 94.0–94.5% and 92.0–93.0% for removal of Co–{sup 60}Co and of Zn–{sup 65}Zn ions, respectively from the examined samples. Graphical Abstract: .

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Structural Origin of Enhanced Luminescence Efficiency of Antimony Irradiated InAs Quantum Dots

We report that Sb irradiation combined with the presence of a GaAs intermediate layer previous to the deposition of a GaSb layer over InAs quantum dots grown by molecular beam epitaxy improves the crystalline quality of these nanostructures. Moreover, this approach to develop III-V-Sb nanostructures causes the formation of quantum dots buried by a confining GaSb layer and, in this way, achieving a type II band alignment. Both phenomena, studied by Conventional transmission electron microscopy (CTEM) and scanning-transmission electron microscope (STEM) techniques are keys to achieve the best room temperature photoluminescence results from InAs/GaAs (001) quantum dots. The Sb flux contributes to the preservation of the quantum dots size and at the same time reduces In diffusion from the wetting layer.

36 MATERIALS SCIENCE↗