At least 397 records · Page 22

Uncertainties in secondary angular distributions and their impact on shielding, criticality and kinetics analysis - 25556

The availability of the covariance data improved over the last decades. Use of covariance matrices of different origin (such as JEFF, JENDL, ENDF, TENDL, SCALE, etc.) and types (files MF31, MF33, MF34, MF35) in sensitivity and uncertainty analysis of vast list of cases ranging from fission to fusion and from criticality, kinetics and shielding to adjustment applications was already studied in the past. The present work focuses on the status and the availability of the covariance of the angular distributions of scattered neutrons (secondary angular distributions - SAD covariances). SAD uncertainties are usually neglected in classical uncertainty propagation codes, even though the methods and codes for calculating the sensitivities are available for decades and excellent agreement was demonstrated between different deterministic and Monte Carlo codes. Of particular concern is still the availability, quality and completeness of covariance matrices. Indeed, in most evaluations the SAD covariances are limited to P1 term, if available at all. Furthermore, some differences were observed between different evaluations, e.g. in the case of iron. (author)

61 RADIATION PROTECTION AND DOSIMETRY↗

Validation of the TOPAS Monte Carlo toolkit for HDR brachytherapy simulations

The goal of this work is to validate the user-friendly Geant4-based Monte Carlo toolkit TOol for PArticle Simulation (TOPAS) for brachytherapy applications. Brachytherapy simulations performed with TOPAS were systematically compared with published TG-186 reference data. The photon emission energy spectrum, the air-kerma strength, and the dose-rate constant of the model-based dose calculation algorithm (MBDCA)-WG generic Ir-192 source were extracted. For dose calculations, a track-length estimator was implemented. Additionally, the four Joint AAPM/ESTRO/ABG MBDCA-WG test cases were evaluated through histograms of the local and global dose difference volumes. A prostate, a palliative lung, and a breast case were simulated. For each case, the dose ratio map, the histogram of the global dose difference volume, and cumulative dose-volume histograms were calculated. The air-kerma strength was (9.772 ± 0.001) × 10 -8 U Bq -1 (within 0.3% of the reference value). The dose-rate constant was 1.1107 ± 0.0005 cGy h -1 U -1 (within 0.01% of the reference value). For all cases, at least 96.9% of voxels had a local dose difference within [-1%, 1%] and at least 99.9% of voxels had a global dose difference within [-0.1%, 0.1%]. The implemented track-length estimator scorer was more efficient than the default analog dose scorer by a factor of 237. For all clinical cases, at least 97.5% of voxels had a global dose difference within [-1%, 1%]. Dose-volume histograms were consistent with the reference data. TOPAS was validated for high-dose-rate brachytherapy simulations following the TG-186 recommended approach for MBDCAs. Built on top of Geant4, TOPAS provides broad access to a state-of-the-art Monte Carlo code for brachytherapy simulations.

59 BASIC BIOLOGICAL SCIENCES↗

An enhanced HOWFARLESS option for DOSXYZnrc simulations of slab geometries

The Monte Carlo code DOSXYZnrc is a valuable instrument for calculating absorbed dose within a three-dimensional Cartesian geometry. DOSXYZnrc includes several variance reduction techniques used to increase the efficiency of the Monte Carlo calculation. One such technique is HOWFARLESS which is used to increase the efficiency of beam commissioning calculations in homogeneous phantoms. The authors present an enhanced version of HOWFARLESS which extends the application to include phantoms inhomogeneous in one dimension. When the enhanced HOWFARLESS was used, efficiency increases as high as 14 times were observed without any loss in dose accuracy. The efficiency gains of an enhanced HOWFARLESS simulation was found to be dependent on both slab geometry and slab density. As the number of two-dimensional voxel layers per slab increases, so does the efficiency gain. Also, as the mass density of a slab is decreased, the efficiency gains increase.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-BRB-02: Towards Quantitative Clinical Decision On Deep Inspiration Breath Hold (DIBH) Or Prone for Left-Sided Breast Irradiation

Purpose: To develop quantitative clinical guidelines between supine Deep Inspiratory Breath Hold (DIBH) and prone free breathing treatments for breast patients, we applied 3D deformable phantoms to perform Monte Carlo simulation to predict corresponding Dose to the Organs at Risk (OARs). Methods: The RPI-adult female phantom (two selected cup sizes: A and D) was used to represent the female patient, and it was simulated using the MCNP6 Monte Carlo code. Doses to OARs were investigated for supine DIBH and prone treatments, considering two breast sizes. The fluence maps of the 6-MV opposed tangential fields were exported. In the Monte Carlo simulation, the fluence maps allow each simulated photon particle to be weighed in the final dose calculation. The relative error of all dose calculations was kept below 5% by simulating 3*10{sup 7} photons for each projection. Results: In terms of dosimetric accuracy, the RPI Adult Female phantom with cup size D in DIBH positioning matched with a DIBH treatment plan of the patient. Based on the simulation results, for cup size D phantom, prone positioning reduced the cardiac dose and the dose to other OARs, while cup size A phantom benefits more from DIBH positioning. Comparing simulation results for cup size A and D phantom, dose to OARs was generally higher for the large breast size due to increased scattering arising from a larger portion of the body in the primary beam. The lower dose that was registered for the heart in the large breast phantom in prone positioning was due to the increase of the distance between the heart and the primary beam when the breast was pendulous. Conclusion: Our 3D deformable phantom appears an excellent tool to predict dose to the OARs for the supine DIBH and prone positions, which might help quantitative clinical decisions. Further investigation will be conducted. National Institutes of Health R01EB015478.

60 APPLIED LIFE SCIENCES↗

Uncertainty Analyses for Localized Tallies in Monte Carlo Eigenvalue Calculations

It is well known that statistical estimates obtained from Monte Carlo criticality simulations can be adversely affected by cycle-to-cycle correlations in the fission source. In addition, there are several other more fundamental issues that may lead to errors in Monte Carlo results. These factors can have a significant impact on the calculated eigenvalue, localized tally means and their associated standard deviations. In fact, modern Monte Carlo computational tools may generate standard deviation estimates that are a factor of five or more lower than the true standard deviation for a particular tally due to the inter-cycle correlations in the fission source. The magnitude of this under-prediction can climb as high as one hundred when combined with an ill-converged fission source or poor sampling techniques. Since Monte Carlo methods are widely used in reactor analysis (as a benchmarking tool) and criticality safety applications, an in-depth understanding of the effects of these issues must be developed in order to support the practical use of Monte Carlo software packages. A rigorous statistical analysis of localized tally results in eigenvalue calculations is presented using the SCALE/KENO-VI and MCNP Monte Carlo codes. The purpose of this analysis is to investigate the under-prediction in the uncertainty and its sensitivity to problem characteristics and calculational parameters, and to provide a comparative study between the two codes with respect to this under-prediction. It is shown herein that adequate source convergence along with proper specification of Monte Carlo parameters can reduce the magnitude of under-prediction in the uncertainty to reasonable levels; below a factor of 2 when inter-cycle correlations in the fission source are not a significant factor. In addition, through the use of a modified sampling procedure, the effects of inter-cycle correlations on both the mean value and standard deviation estimates can be isolated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of the single-event method for low-energy electron transport via stopping power calculations with $\mathrm{MCNP}$

Monte Carlo simulations of low-energy ( <50 keV) electron transport in matter are essential for a broad range of application fields. Several Monte Carlo codes have developed specialized treatments for this case, but a comprehensive validation of low-energy electron transport for general-purpose simulations remains lacking in the literature. One approach to accomplish this validation is calculation of stopping power using low-energy electron transport physics, as stopping power is a fundamental radiation transport quantity which must be simulated accurately for nearly any application. Here in this work, we use the Monte Carlo N-Particle (MCNP) radiation transport code with the single-event method for electron transport to calculate stopping powers of low-energy electrons (50 eV to 30 keV) in 41 elemental solids, 14 compound solids, and five rare gas solids, comparing simulation results to published semi-empirical stopping power calculations from optical measurements. In general, the simulations give good agreement (typically within ±10%) with semi-empirical stopping power values at higher energies: 300 eV and above for most elemental solids, 1 keV and above for compound solids, and 400 eV and above for rare gas solids. Agreement between MCNP and semi-empirical values is worse below these energies. The most significant source of error is the EPRDATA14 cross section data, which does not account for changes in electronic structure due to solid-state bonding, particularly in compound materials. The simplistic model of atomic excitation used to generate the EPRDATA14 cross sections is another key source of error. Additionally, the breakdown of the continuous slowing-down approximation introduces significant uncertainty at low energies, although this is a limitation of the calculation method and not of the simulation procedure. Accounting for these and other uncertainty sources, the single event method in MCNP is robust and able to give good accuracy for a variety of low-energy electron transport problems through diverse kinds of materials.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Personalized Assessment of kV Cone Beam Computed Tomography Doses in Image-guided Radiotherapy of Pediatric Cancer Patients

Purpose: To develop a quantitative method for the estimation of kV cone beam computed tomography (kVCBCT) doses in pediatric patients undergoing image-guided radiotherapy. Methods and Materials: Forty-two children were retrospectively analyzed in subgroups of different scanned regions: one group in the head-and-neck and the other group in the pelvis. Critical structures in planning CT images were delineated on an Eclipse treatment planning system before being converted into CT phantoms for Monte Carlo simulations. A benchmarked EGS4 Monte Carlo code was used to calculate three-dimensional dose distributions of kVCBCT scans with full-fan high-quality head or half-fan pelvis protocols predefined by the manufacturer. Based on planning CT images and structures exported in DICOM RT format, occipital-frontal circumferences (OFC) were calculated for head-and-neck patients using DICOMan software. Similarly, hip circumferences (HIP) were acquired for the pelvic group. Correlations between mean organ doses and age, weight, OFC, and HIP values were analyzed with SigmaPlot software suite, where regression performances were analyzed with relative dose differences (RDD) and coefficients of determination (R{sup 2}). Results: kVCBCT-contributed mean doses to all critical structures decreased monotonically with studied parameters, with a steeper decrease in the pelvis than in the head. Empirical functions have been developed for a dose estimation of the major organs at risk in the head and pelvis, respectively. If evaluated with physical parameters other than age, a mean RDD of up to 7.9% was observed for all the structures in our population of 42 patients. Conclusions: kVCBCT doses are highly correlated with patient size. According to this study, weight can be used as a primary index for dose assessment in both head and pelvis scans, while OFC and HIP may serve as secondary indices for dose estimation in corresponding regions. With the proposed empirical functions, it is possible to perform an individualized quantitative dose assessment of kVCBCT scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-19A-03: Monte Carlo Investigation of the Mobetron to Perform Modulated Electron Beam Therapy

Purpose: Modulated electron radiotherapy (MERT) has been proposed as a mean of delivering conformal dose to shallow tumors while sparing distal structures and surrounding tissues. In intraoperative radiotherapy (IORT) utilizing Mobetron, an applicator is placed as closely as possible to the suspected cancerous tissues to be treated. In this study we investigate the characteristics of Mobetron electron beams collimated by an in-house prospective electron multileaf collimator (eMLC) and its feasibility for MERT. Methods: IntraOp Mobetron™ dedicated to perform radiotherapy during surgery was used in the study. It provides several energies (6, 9 and 12 MeV). Dosimetry measurements were performed to obtain percentage depth dose curves (PDD) and profiles for a 10-cm diameter applicator using the PTW MP3/XS 3D-scanning system and the semiflex ion chamber. MCBEAM/MCSIM Monte Carlo codes were used for the treatment head simulation and phantom dose calculation. The design of an electron beam collimation by an eMLC attached to the Mobetron head was also investigated using Monte Carlo simulations. Isodose distributions resulting from eMLC collimated beams were compared to that collimated using cutouts. The design for our Mobetron eMLC is based on our previous experiences with eMLCs designed for clinical linear accelerators. For Mobetron the eMLC is attached to the end of a spacer-mounted rectangular applicator at 50 cm SSD. Steel will be used as the leaf material because other materials would be toxic and will not be suitable for intraoperative applications. Results: Good agreement (within 2%) was achieved between measured and calculated PDD curves and profiles for all available energies. Dose distributiosn provided by the eMLC showed reasonable agreement (∼3%/1mm) with those obtained by conventional cutouts. Conclusion: Monte Carlo simulations are capable of modeling Mobetron electron beams with a reliable accuracy. An eMLC attached to the Mobteron treatment head will allow better treatment options with those machines.

60 APPLIED LIFE SCIENCES↗

Development of 3D full-core ERANOS-2.2/MCNPX-2.7.0 models and neutronic analysis of the BFS-2 zero-power facility

The present paper is addressing the development and validation against experimental data of 3D full-core models of the BFS-2 zero-power fast-reactor using both the deterministic system code ERANOS-2.2 and the stochastic code MCNPX-2.7.0. The model configuration of BFS considered for analysis is the BFS-62-3A benchmark. To extend the - deterministic/stochastic - code-to-code comparison, neutronic parameters, i.e. reactivity, neutron spectrum and reaction rates, were also simulated at the cell level with the Monte Carlo code SERPENT-1.1.7 with two modern data libraries, ENDF-B/VII and JEFF-3.1.1. The BFS-2 critical zero-power facility at the Inst. of Physics and Power Engineering (IPPE) was designed for simulations of the core and shielding of sodium-cooled, fast reactors, for neutron data validation and comparison with experimental results. At the BFS-2 facility, the BFS-62-3A critical benchmark experiment was set-up as a mock-up of the BN-600 reactor, with hybrid MOX fuel and stainless steel reflectors. A UO{sub 2} blanket and a large non-homogeneous stainless-steel reflector surround the core. The lattice is hexagonal of pitch 5.1 cm and metallic dowels are used to keep in central position cylindrical rods made of different types of material (fissile, fertile, blanket, plenum, shielding and absorber). A typical subassembly is formed in piling up various pellets of about 1 cm in height and 4.6 cm in diameter, conferring large heterogeneity in the axial direction. The full-core model development was a complex task due to the large number of subassemblies and the axial subassembly heterogeneity. In ERANOS-2.2, it was necessary to homogenize axially per region the pellets used to form the subassembly. The self-shielded macroscopic cross-sections were calculated using the cell code ECCO in association with JEFF-3.1 and ENDF/B-VI.8 data libraries. The core calculations were performed with broad cross-sections data in 33 neutron energy groups with the solver AVNM in the diffusion approximation, mostly. In MCNPX-2.7.0, a step-by-step approach was used, starting with a model in which the fissile rods were simulated on a homogeneous level, to finally integrate the actual heterogeneous description of the subassemblies. The code-to-code cell analysis performed between ECCO, SERPENT and MCNPX with different modern nuclear data library revealed that the results for the infinite multiplication factor between Monte Carlo and deterministic analysis are in good agreement ({Delta}p < 100 pcm). The differences between the results were observed to be larger for the neutron data libraries, with reactivity differences up to 350 pcm. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High conversion Th-U{sup 233} fuel assembly for current generation of PWRs

This paper presents a preliminary design of a high conversion Th-U{sup 233} fuel assembly applicable for current generation of Pressurized Water Reactor (PWRs). The considered fuel assembly has a typical 17 x 17 PWR lattice. However in order to increase the conversion of Th{sup 232} to U{sup 233}, the assembly was subdivided into the two regions called seed and blanket. The central seed region has a higher than blanket U{sup 233} content and acts as a neutron source for the peripheral blanket region. The latest acts as a U{sup 233} breeder. While the seed fuel pins have a standard dimensions the blanket fuel radius was increased in order to reduce the moderation and to facilitate the resonance neutron absorption in blanket Th{sup 232}. The U{sup 233} content in the seed and blanket regions was optimized to achieve maximal initial to discharged fissile inventory ratio (FIR) taking into account the target fuel cycle length of 12 months with 3-batch reloading scheme. In this study the neutronic calculations were performed on the fuel assembly level using Helios deterministic lattice transport code. The fuel cycle length and the core k{sub eff} were estimated by applying the Non Linear Reactivity Model. The applicability of the HELIOS code for the analysis of the Th-based high conversion designs was confirmed with the help of continuous-energy Monte-Carlo code SERPENT. The results of optimization studies show that for the heterogeneous seed and blanket (SB) fuel assembly the FIR of about 0.95 can be achieved. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Full 3D visualization tool-kit for Monte Carlo and deterministic transport codes

We propose a package of tools capable of translating the geometric inputs and outputs of many Monte Carlo and deterministic radiation transport codes into open source file formats. These tools are aimed at bridging the gap between trusted, widely-used radiation analysis codes and very powerful, more recent and commonly used visualization software, thus supporting the design process and helping with shielding optimization. Three main lines of development were followed: mesh-based analysis of Monte Carlo codes, mesh-based analysis of deterministic codes and Monte Carlo surface meshing. The developed kit is considered a powerful and cost-effective tool in the computer-aided design for radiation transport code users of the nuclear world, and in particular in the fields of core design and radiation analysis. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

On Monte Carlo modeling of megavoltage photon beams: A revisited study on the sensitivity of beam parameters

Purpose: To commission Monte Carlo beam models for five Varian megavoltage photon beams (4, 6, 10, 15, and 18 MV). The goal is to closely match measured dose distributions in water for a wide range of field sizes (from 2x2 to 35x35 cm{sup 2}). The second objective is to reinvestigate the sensitivity of the calculated dose distributions to variations in the primary electron beam parameters. Methods: The GEPTS Monte Carlo code is used for photon beam simulations and dose calculations. The linear accelerator geometric models are based on (i) manufacturer specifications, (ii) corrections made by Chibani and Ma [''On the discrepancies between Monte Carlo dose calculations and measurements for the 18 MV Varian photon beam,'' Med. Phys. 34, 1206-1216 (2007)], and (iii) more recent drawings. Measurements were performed using pinpoint and Farmer ionization chambers, depending on the field size. Phase space calculations for small fields were performed with and without angle-based photon splitting. In addition to the three commonly used primary electron beam parameters (E{sub AV} is the mean energy, FWHM is the energy spectrum broadening, and R is the beam radius), the angular divergence ({theta}) of primary electrons is also considered. Results: The calculated and measured dose distributions agreed to within 1% local difference at any depth beyond 1 cm for different energies and for field sizes varying from 2x2 to 35x35 cm{sup 2}. In the penumbra regions, the distance to agreement is better than 0.5 mm, except for 15 MV (0.4-1 mm). The measured and calculated output factors agreed to within 1.2%. The 6, 10, and 18 MV beam models use {theta}=0 deg., while the 4 and 15 MV beam models require {theta}=0.5 deg. and 0.6 deg., respectively. The parameter sensitivity study shows that varying the beam parameters around the solution can lead to 5% differences with measurements for small (e.g., 2x2 cm{sup 2}) and large (e.g., 35x35 cm{sup 2}) fields, while a perfect agreement is maintained for the 10x10 cm{sup 2} field. The influence of R on the central-axis depth dose and the strong influence of {theta} on the lateral dose profiles are demonstrated. Conclusions: Dose distributions for very small and very large fields were proved to be more sensitive to variations in E{sub AV}, R, and {theta} in comparison with the 10x10 cm{sup 2} field. Monte Carlo beam models need to be validated for a wide range of field sizes including small field sizes (e.g., 2x2 cm{sup 2}).

43 PARTICLE ACCELERATORS↗

Parallel Performance of the Time Dependent Transport Code TDKENO with Applications to TREAT Simulations

Renewed interest in high fidelity simulation of excursion events has prompted the improvement of codes that solve the time-dependent Boltzmann transport equation. Often these codes make approximations to the transport equation in order to achieve results in a reasonable amount of time. One method, the improved quasi-static (IQS), makes few approximations compared to adiabatic, diffusion, and point kinetics. This is the methodology employed by the code TDKENO. One downside to this approach is a portion of the calculation (flux shape) is done with a Monte Carlo code and must be called upon several times. To minimize run time the flux shape calculation is solved with a modified version of KENO-VI from Scale 6.2. This version of KENO runs in parallel across hundreds of nodes, thus improving performance. The parallel capabilities of KENO allows TDKENO to simulate complex transient experiments with a large number of histories. These improvements are applied to the simulation of TREAT calibration experiments. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Convective Heating of the LIFE Engine Target During Injection

Target survival in the hostile, high temperature xenon environment of the proposed Laser Inertial Fusion Energy (LIFE) engine is critical. This work focuses on the flow properties and convective heat load imposed upon the surface of the indirect drive target while traveling through the xenon gas. While this rarefied flow is traditionally characterized as being within the continuum regime, it is approaching transition where conventional CFD codes reach their bounds of operation. Thus ANSYS, specifically the Navier-Stokes module CFX, will be used in parallel with direct simulation Monte Carlo code DS2V and analytically and empirically derived expressions for heat transfer to the hohlraum for validation. Comparison of the viscous and thermal boundary layers of ANSYS and DS2V were shown to be nearly identical, with the surface heat flux varying less than 8% on average. From the results herein, external baffles have been shown to reduce this heat transfer to the sensitive laser entrance hole (LEH) windows and optimize target survival independent of other reactor parameters.

42 ENGINEERING↗

Flattening of fuel importance for heterogeneous system to estimate maximal multiplication factor - 14595

In order to quantify risks of re-criticality incidents associated with loss of coolant accidents (LOCA), the maximum reactivity insertion by relocation of damaged fuel should be quantified. As the first step for the quantification, an automated search scheme is studied for an optimal geometry of damaged fuel in the coolant channel where the neutron multiplication factor k{sub eff} takes a maximal value. The scheme is based on the flattening of the fuel importance. The importance can be recognized as the substitution reactivity from fuel to water in heterogeneous systems. The flattening is achieved by substitution of water and the fuel so as to raise the k{sub eff} referring the local substitution reactivities. To calculate the reactivities efficiently, the first order perturbation scheme is adopted. In the scheme, the adjoint flux is calculated with the PARTISN code. The multi group constants used for the calculation and the perturbed reaction rates are estimated with the continuous energy Monte Carlo code MCNP-5. The proposed methods are tested for a quarter pin cell model that is constructed using Cartesian mesh. From a random distribution of a given amount of fragmented fuel, an optimal geometry is found where the fragmented fuels are aggregated. The multiplication factor in the geometry is greater than that in the original random distribution by 1.4%Δk/k. That indicates the significance of this study. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Monte Carlo Criticality Methods and Analysis Capabilities in SCALE

This paper describes the Monte Carlo codes KENO V.a and KENO-VI in SCALE that are primarily used to calculate multiplication factors and flux distributions of fissile systems. Both codes allow explicit geometric representation of the target systems and are used internationally for safety analyses involving fissile materials. KENO V.a has limiting geometric rules such as no intersections and no rotations. These limitations make KENO V.a execute very efficiently and run very fast. On the other hand, KENO-VI allows very complex geometric modeling. Both KENO codes can utilize either continuous-energy or multigroup cross-section data and have been thoroughly verified and validated with ENDF libraries through ENDF/B-VII.0, which has been first distributed with SCALE 6. Development of the Monte Carlo solution technique and solution methodology as applied in both KENO codes is explained in this paper. Available options and proper application of the options and techniques are also discussed. Finally, performance of the codes is demonstrated using published benchmark problems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Scrape-off layer plasma and neutral characteristics and their interactions with walls for FNSF

Simulations of the heat flux on plasma facing components from exhausting core plasma are reported for two possible Fusion Nuclear Science Facility (FNSF) divertor configurations. One configuration utilizes divertor plates strongly inclined with respect to the poloidal magnetic flux surfaces like that planned for ITER and results in a partially detached divertor-plasma. The second configuration has divertor plates orthogonal to the flux surfaces, which leads to a fully detached divertor-plasma if the width of the divertor region is sufficient. Both configurations use scrape-off layer impurity seeding to yield an acceptable peak heat flux of ~10 MW/m 2 or smaller on the divertor plates and chamber walls. The roles of recycled hydrogenic atoms and molecules are investigated and distribution of sputtering tungsten throughout the edge region modeled. Furthermore, the simulations are performed with the UEDGE 2D transport code to model both plasma and neutral components with supplementary neutral modeling performed with the DEGAS 2 Monte Carlo code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of nuclear data processing code FRENDY version 2

Nuclear data processing is an important interface between an evaluated nuclear data library and neutronics calculation codes. JAEA has been developed the new nuclear data processing code FRENDY from 2013. FRENDY version 1 generates the ACE files used for the continuous-energy Monte Carlo codes including PHITS, Solomon, Serpent,and MCNP and it was released as the open-source software under the 2-clause BSD license in 2019.After we released FRENDY version 1, many functions, e.g., the multi-group neutron cross-section library generation, the statistical uncertainty quantification of the probability tables for unresolved resonance cross-section, the 'perturbation' of the ACE file for uncertainty quantification, and the modification of the ENDF-6 formatted nuclear data file, have been developed. We released FRENDY version 2 including these functions. The present paper gives an overview of FRENDY and presents features of new functions implemented in FRENDY version 2. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗