Search NASA⌕ Search

SEARCH · Search NASA

Results for “NEUTRON SCIENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Results of the first implementation of RF phase signature matching at LANSCE

The LINAC at the Los Alamos Neutron Science Center (LANSCE) has been utilizing the Delta-t method to match the RF cavities to the design acceleration parameters since its commissioning in 1972. The differences in time-of-flight between two subsequent Beam Position and Phase Monitors (BPPMs) are measured with both accelerated and drifting beams, depending on the whether the module is set to on or off. The algorithm optimizes the module amplitude and phase via iterative measurements if the initial phase is in the vicinity of the design value. With an upgrade to a faster readout system, a scan over the whole RF cavity phase range requires relatively less time than the classical optimization procedure. The Phase Scan Signature Matching (PSSM) method provides a time-efficient method that ensures the phase selection lands on the bunching side and empowers future analyses to build module-specific models. The PSSM also utilizes a direct model to determine the correct amplitude to sub-percent level instead of using linearized matrices. Furthermore, lacking a reliable energy measurement method in the LINAC, we measure the beam phases at two downstream locations to increase the precision of energy measurements. In this letter, we also discuss the sensitivities of PSSM, error propagation, and the implementation results for the 2019 and 2020 beam cycles.

47 OTHER INSTRUMENTATION↗

Exploring cesium properties internal to the LANSCE H - ion source using resonant absorption spectroscopy

The Los Alamos Neutron Science Center (LANSCE) H - ion source has provided stable output for decades of LANL mission needs, but its maximum beam output has remained the same at ~15 mA. A roadblock to improving beam output has been a lack of thorough understanding of the internal mechanisms of LANSCE H - ion source. The LANSCE H - Ion Source Laser Diagnostic Stand (HLDS) was recently built and commissioned to explore these internal mechanisms using laser absorption techniques, to measure and diagnose dynamic H - and cesium densities. The cesium density probe is based on resonant absorption of a continuous wave diode laser tuned though the D 2 line of cesium (~852 nm). The diagnostic capabilities of HLDS will be reviewed, and measurements using the cesium laser diagnostic will be presented.

43 PARTICLE ACCELERATORS↗

Multi-beam operation of LANSCE accelerator facility

The Los Alamos Neutron Science Center (LANSCE) accelerator facility has been in operation for 50 years performing important scientific support for national security. The unique feature of the LANSCE accelerator facility is multi-beam operation, delivering beams to five experimental areas. The near-term plans are to replace obsolete and almost end-of-life systems of the LANSCE linear accelerator with a modern 100-MeV Front End with significant improvement in beam quality. This paper summarizes experimental results obtained during the operation of the LANSCE accelerator facility and considers plans to expand the performance of the accelerator for near- and long-term operations.

47 OTHER INSTRUMENTATION↗

The NIFFTE Project

The Neutron Induced Fission Fragment Tracking Experiment (NIFFTE) is a double-sided Time Projection Chamber (TPC) with micromegas readout designed to measure the energy-dependent neutron-induced fission cross sections of the major and minor actinides with unprecedented accuracy. The NIFFTE project addresses the challenge of minimizing major sources of systematic uncertainties from previous fission chamber measurements such as: target and beam non-uniformities, misidentification of alpha and light charged particles as fission fragments, and uncertainties inherent to the reference standards used. In-beam tests of the NIFFTE TPC at the Los Alamos Neutron Science Center (LANSCE) started in 2010 and have continued in 2011, 2012 and 2013. An overview of the NIFFTE TPC status and performance at LANSCE will be presented.

gaseous detectors↗

A TOPAS model for lens-based proton radiography

Abstract Objective. Proton Radiography can be used in conjunction with proton therapy for patient positioning, real-time estimates of stopping power, and adaptive therapy in regions with motion. The modeling capability shown here can be used to evaluate lens-based radiography as an instantaneous proton-based radiographic technique. The utilization of user-friendly Monte Carlo program TOPAS enables collaborators and other users to easily conduct medical- and therapy- based simulations of the Los Alamos Neutron Science Center (LANSCE). The resulting transport model is an open-source Monte Carlo package for simulations of proton and heavy ion therapy treatments and concurrent particle imaging. Approach. The four-quadrupole, magnetic lens system of the 800-MeV proton beamline at LANSCE is modeled in TOPAS. Several imaging and contrast objects were modelled to assess transmission at energies from 230–930 MeV and different levels of particle collimation. At different proton energies, the strength of the magnetic field was scaled according to βγ, the inverse product of particle relativistic velocity and particle momentum. Main results. Materials with high atomic number, Z, (gold, gallium, bone-equivalent) generated more contrast than materials with low-Z (water, lung-equivalent, adipose-equivalent). A 5-mrad collimator was beneficial for tissue-to-contrast agent contrast, while a 10-mrad collimator was best to distinguish between different high-Z materials. Assessment with a step-wedge phantom showed water-equivalent path length did not scale directly according to predicted values but could be mapped more accurately with calibration. Poor image quality was observed at low energies (230 MeV), but improved as proton energy increased, with sub-mm resolution at 630 MeV. Significance. Proton radiography becomes viable for shallow bone structures at 330 MeV, and for deeper structures at 630 MeV. Visibility improves with use of high-Z contrast agents. This modality may be particularly viable at carbon therapy centers with accelerators capable of delivering high energy protons and could be performed with carbon therapy.

60 APPLIED LIFE SCIENCES↗

High-gradient performance of a prototype accelerator cavity for a 3 GeV proton radiography booster

This paper reports the design, fabrication, and results of the high-gradient conditioning and testing for a two-cell, π -mode, standing wave normal-conducting prototype booster cavity for the proposed 3 GeV proton linac upgrade at Los Alamos Neutron Science Center. Increasing the energy of proton beam from the existing 800 MeV to 3 GeV will improve resolution of the proton radiography by up to 10 times. The proposed energy boost can be achieved with a compact normal-conducting high-gradient radio-frequency (rf) linac section. The C-band section of the booster linac was designed with optimized-shaped copper accelerator cavities with distributed rf coupling. A short two-cell test prototype structure was designed for the frequency of 5.712 GHz, fabricated, and tested at the C-band Engineering Research Test Facility in New Mexico (CERF-NM) at Los Alamos National Laboratory. The maximum klystron power coupled into the test structure was 8.3 MW with 1 μ s pulse length and 100 Hz repetition rate. The breakdown probabilities were recorded as functions of the accelerating gradient and peak surface fields. Operation of the test cavity at accelerating gradients of up to 100 MV / m was demonstrated. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Nonstatistical fluctuations in the 35 Cl(n,p) 35 S reaction cross section at fast-neutron energies from 0.6 to 6 MeV

The lack of experimental data on the 35 Cl(n,p) 35 S reaction above 100 keV has led to nuclear data evaluations that are relatively unconstrained at fast neutron energies. As a result, efforts to explore, develop, and potentially certify next generation reactor designs that incorporate chloride salts as a coolant material have been hindered. Here, we report partial cross section data for the 35 Cl(n,p) 35 S and 35 Cl(n,α) 32 P reactions at incident neutron energies between 0.6 MeV and 6 MeV. The measurement was performed using the pulsed beam of neutrons at the unmoderated WNR spallation neutron source at the Los Alamos Neutron Science Center, with the outgoing charged particles detected by the LENZ experimental setup, consisting of annular silicon detectors. Nonstatistical fluctuations in the 35 Cl(n,p 0 ) cross section were observed up to around 3 MeV, and the magnitude of the cross section was systematically lower than all available data evaluations at energies above 1 MeV. Modifications to the ENDF/B-VIII.0 data evaluation are suggested to better reproduce the energy averaged experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constraining the calculation of U 234 , 236 , 238 ( n , γ ) cross sections with measurements of the γ -ray spectra at the DANCE facility

The cross section for neutron capture in the continuum region has been difficult to calculate accurately. Previous results for 238 U show that including an M 1 scissors-mode contribution to the photon strength function resulted in very good agreement between calculation and measurement. Our paper extends that analysis to 234 , 236 U by using γ -ray spectra measured with the Detector for Advanced Neutron Capture Experiments (DANCE) at the Los Alamos Neutron Science Center to constrain the photon strength function used to calculate the capture cross section. Calculations using a strong scissors-mode contribution reproduced the measured γ -ray spectra and were in excellent agreement with the reported cross sections for all three isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the 65 Cu(η, γ) cross section using the Detector for Advanced Neutron Capture Experiments at LANL

Improving our understanding of the origin of the elements in the observable universe as well as the nature of the environments responsible for their production has been of paramount importance to the nuclear physics community. More than half of the isotopes of these elements are created via neutron-capture processes, and thus accurate measurements of the salient underlying nuclear physics, such as neutron-capture cross sections, masses, and β-decay half-lives are crucial. Of particular signifcance to the synthesis of isotopes in the mass range of A ≈ 60 to A ≈ 90, via the weak s process, are the neutron-capture cross sections of 63,65 Cu, where large discrepancies between measurements exist. Recent measurements have addressed these discrepancies for 63 Cu [Weigand et al., Phys. Rev. C 95, 015808 (2017)], but questions still remain for 65 Cu. Here, we report a new measurement of the 65Cu(n, γ ) cross section performed using the Detector for Advanced Neutron Capture Experiments located at the Los Alamos Neutron Science Center of Los Alamos National Laboratory. The Maxwellian-averaged cross section (MACS) for 65 Cu(η, γ) at $kT$ = 30 keV deduced from this work is (37.0 ± 0.3 stat. ± 3.3 sys. ) mb. The impact on weak s-process nucleosynthesis of new MACS values, calculated over the range of kT = 5 to 100 keV, for 65 Cu, combined with the updated MACS for 63 Cu [Weigand et al., Phys. Rev. C 95, 015808 (2017)] and 63 Ni [Weigand et al., Phys. Rev. C 92, 045810 (2015)], were investigated. Findings of this investigation show an increase of predicted nucleosynthesis yields of elements of Zn to Zr by as much as 20%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Model-independent particle accelerator tuning

We present a new model-independent dynamic feedback technique, rotation rate tuning, for automatically and simultaneously tuning coupled components of uncertain, complex systems. The main advantages of the method are: 1) It has the ability to handle unknown, time-varying systems, 2) It gives known bounds on parameter update rates, 3) We give an analytic proof of its convergence and its stability, and 4) It has a simple digital implementation through a control system such as the Experimental Physics and Industrial Control System (EPICS). Because this technique is model independent it may be useful as a real-time, in-hardware, feedback-based optimization scheme for uncertain and time-varying systems. In particular, it is robust enough to handle uncertainty due to coupling, thermal cycling, misalignments, and manufacturing imperfections. As a result, it may be used as a fine-tuning supplement for existing accelerator tuning/control schemes. We present multi-particle simulation results demonstrating the scheme’s ability to simultaneously adaptively adjust the set points of twenty two quadrupole magnets and two RF buncher cavities in the Los Alamos Neutron Science Center Linear Accelerator’s transport region, while the beam properties and RF phase shift are continuously varying. The tuning is based only on beam current readings, without knowledge of particle dynamics. We also present an outline of how to implement this general scheme in software for optimization, and in hardware for feedback-based control/tuning, for a wide range of systems.

42 ENGINEERING↗

Latent diffusion can map beam loss to two-dimensional phase-space projections

Beam loss monitors (BLMs) and beam current monitors (BCMs) are ubiquitous at particle accelerators around the world. These simple devices provide noninvasive high-level beam measurements but give no insight into the detailed 6D (𝑥,𝑦,𝑧,𝑝 𝑥 ,𝑝 𝑦 ,𝑝 𝑧 ) beam phase-space distributions or dynamics. We show that generative conditional latent diffusion models can learn intricate patterns to solve the extreme inverse problem of mapping waveforms of tens of BLMs or BCMs along an accelerator to detailed 2D projections of a charged particle beam’s 6D phase-space density. This transformational method can be used at any particle accelerator to transform simple noninvasive devices into detailed beam phase-space diagnostics. We demonstrate this concept via multiparticle simulations of the high-intensity beam in the kilometer-long Los Alamos Neutron Science Center linear proton accelerator.

43 PARTICLE ACCELERATORS↗

Experimental Safe Extremum Seeking for Accelerators

Here, we demonstrate the recent designs of safe extremum seeking (Safe ES) on the 1-km-long charged particle accelerator at the Los Alamos Neutron Science Center (LANSCE). Safe ES is a modification of extremum seeking (ES) which, in addition to minimizing an analytically unknown cost, also employs a safety filter based on an analytically unknown control barrier function (CBF) safety metric. Tuning is necessitated by accelerators being large complex systems, with many drifting parameters due to thermal effects and degradation. At the same time, safe operation (the maintenance of state constraints) is crucial, as damage brings astronomical costs, both financially and in operation downtime. Our measured (but analytically unknown) safety metric is the beam current. We perform multivariable Safe ES on three accelerator applications, in which we adapt 4, 6, and 3 magnet strength parameters, respectively. Two of the three applications are for validated simulation models of beamlines at LANSCE: the first for the proton radiography (pRad) beamline of 800-MeV protons for spot size tuning; the second on a high-performance code, HPSim, for tuning the low-energy beam transport (LEBT) region that contains a beam of 750-keV protons. The third is an experimental tuning of the steering magnets in the LEBT at LANSCE.

43 PARTICLE ACCELERATORS↗

Analysis of Radiation Effects in Silicon using Kinetic Monte Carlo Methods

The transient degradation of semiconductor device performance under irradiation has long been an issue of concern. Neutron irradiation can instigate the formation of quasi-stable defect structures, thereby introducing new energy levels into the bandgap that alter carrier lifetimes and give rise to such phenomena as gain degradation in bipolar junction transistors. Normally, the initial defect formation phase is followed by a recovery phase in which defect-defect or defect-dopant interactions modify the characteristics of the damaged structure. A kinetic Monte Carlo (KMC) code has been developed to model both thermal and carrier injection annealing of initial defect structures in semiconductor materials. The code is employed to investigate annealing in electron-irradiated, p-type silicon as well as the recovery of base current in silicon transistors bombarded with neutrons at the Los Alamos Neutron Science Center (LANSCE) “Blue Room” facility. Our results reveal that KMC calculations agree well with these experiments once adjustments are made, within the appropriate uncertainty bounds, to some of the sensitive defect parameters.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A compact furnace to support in situ neutron imaging of hydrogen dynamics in yttrium hydride moderators

A compact, nuclear microreactor that utilizes low-enriched uranium fuel is a promising solution to meet U.S. energy demands in nonconventional nuclear markets such as remote and decentralized energy grids. Yttrium hydride (YHx) is a potential moderator material for a microreactor design that reduces the amount of required fuel and provides superior retention of hydrogen at high reactor operating temperatures. Hydrogen diffusion properties in YHx are highly sought after for computer model validation and reactor prototyping. To characterize hydrogen diffusion, a compact dual-zone furnace was developed at Los Alamos National Laboratory and analyzed via neutron imaging at the Los Alamos Neutron Science Center (LANSCE). The goal of these measurements is to assess hydrogen diffusion in YHx samples as a function of applied temperature gradients. Included herein is recent progress in technique and furnace developments as well as initial results from concentration- and temperature-gradient measurements at LANSCE.

Torres, James↗

TPC measurement support

A new instrument for high precision fission cross sections, the Time Projection Chamber (TPC), is being developed by the NIFFTE (Neutron Induced Fission Fragment Tracking Experiment) collaboration which consists of six universities and three national laboratories. The measurements with the TPC will be carried out at the Los Alamos Neutron Science Center (LANSCE), and one of the roles of the LANL collaborators is to support the TPC measurement program. That support for FY12 is outlined in this report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MPACT LSDS Progress Report: LANL and LANL-Funded Activities in Support of Spent Fuel Measurements Using a Lead Slowing Down Spectrometer in FY 2012

During FY 2012, Lead Slowing Down Spectrometer (LSDS) measurement campaigns took place at the Los Alamos Neutron Science Center, and the Rensselaer Polytechnic Institute. At Los Alamos, we measured the response of a thorium fission chamber to a 25 gram plutonium sample, and evaluated the performance of a 4 He-filled proportional counter. At RPI, the effort lead by Professor Danon, performed an assay of fuel pins, and used a fission chamber with plutonium to evaluate the impact of room return.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A high resolutuion ionization chamber for the SPIDER fission fragment detector

An ionization chamber for measuring the energy loss and kinetic energy of fragments produced through neutron-induced fission at the Los Alamos Neutron Science Center (LANSCE) has been designed as a component of the the new SPIDER detector. Design criteria included energy resolutions of <1% for high energy resolution and increased charge resolution. The ionization chamber will be combined with a high resolution time-of-flight detector to achieve fragment yield measurements with mass and nuclear charge resolutions of 1 amu and Z=1. The present status of the ionization chamber will be presented.

Instrumentation Related to Nuclear Science & Techn↗

SWEIS Yearbook 2011: Comparison of 2011 Data to Projections of the Site-Wide Environmental Impact Statement for Continued Operation of the Los Alamos National Laboratory

Los Alamos National Laboratory (LANL) operations data for CY 2011 mostly fell within the 2008 SWEIS projections. Operation levels for four LANL facilities exceeded the 2008 SWEIS capability projections – Los Alamos Neutron Science Center (LANSCE), Solid Radioactive and Chemical Waste (SRCW), Materials Science Laboratory (MSL) and Radiochemistry Facilities. However, none of these capability increases caused exceedances in waste generation, radioactive air emissions, or NPDES discharge. Several facilities exceeded the SWEIS levels for waste generation quantities; however, all were one-time, non-routine events that do not reflect the day-to-day operations of the Laboratory. In addition, total site-wide waste generation quantities were below SWEIS projections for all waste types, reflecting the overall levels of operations at both the Key and Non-Key Facilities. Although gas and electricity consumption have remained within the 2008 SWEIS limits for utilities, water consumption exceeded the 2008 SWEIS projections by 10 million gallons in CY 2011.

Energy Conservation, Consumption, & Utilization(32↗